Boeing MD-90-30
Service difficulty reports · 6,066
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ORJA99117Terminal · brokenIN SJC, OVERHEAD CEILING EMERGENCY LIGHTS OUT FROM ROWS 7 TO AFT CABIN. FOUND BROKEN TERMINAL AT 33-550 NR 11. REPAIRED AND SECURED, OPS CHECK GOOD. (M)SDR DLM90990538Engine · failedLEFT ENGINE FAILURE WHEN T/O POWER APPLIED. REPLACED ENGINE.SDR ORJA99113Battery Pack · dischargedSJC - OVERWING EMERGENCY LIGHT STAY ILLUMINATED. REMOVED AND REPLACED BATTERY PACKS AT ROW 22 AND 19. OPS CHECK EMERGENCY LIGHTS OPS CHECK OK. (M)SDR ORJA99111Battery Pack · dischargedSJC - EMERGENCY EXIT LIGHTS OVERWING EXITS ARE FLASHING INTERMITTENTLY. REMOVED AND REPLACED E-PATH LIGHT BATTERY PACK AT 27, OPS CHECK OK. (M)SDR ORJA99103Line · damagedSJC - ON ARRIVAL INTO SJC, LOST OIL QUANTITY AND PRESSURE IN LEFT ENGINE. FLIGHT CREW FOLLOWED THEIR PROCEDURES IN THE QRH AND SHUT DOWN THE NR 1 ENGINE. EMERGENCY WAS DECLARED WITH ATC. FOUND DAMAGED OIL LINE. REMOVED AND REPLACED OIL PRESSURE SCAVAGE LINSDR DLM90990439Light · brokenEMERGENCY FLOOR LIGHT BY SEAT 1C IS BROKEN AND FLOOR LIGHT TRACK IS CRACKED. REPLACED LIGHT ASSY AND WIRING, OPS CKD NORMAL.SDR ORJA9989Controller · malfunctionedAT SNA - TAIL TEMP FAULT LIGHT ILLUMINATED ON RUNWAY BEFORE TAKEOFF SNA. INTERGRATED PNEUMATIC OVERHEAT DETECTION CONTROLLER, FAULTS CLEARED. (M)SDR ORJA9947Wire · disconnectedIN SJC, OVERHEAD EMERGENCY LIGHTS INOPERATIVE AT STATION 1240. REMOVED CEILING PANEL AND FOUND LOOSE WIRES, RECONNECTED. OPS CHECK NORMAL. (M)SDR ORJA9921Battery Pack · dischargedIN SJC, EMERGENCY FLOOR LIGHTS INOPERATIVE FOR ROWS 6-20. REMOVED AND REPLACED BATTERY PACK AT ROW 5, OPS CHECK GOOD. (M)SDR ORJA98332Transducer · failedSJC - AUTO SPOILER FAIL AND ANTI-SKID FAULT MESSAGE ANNUNCIATED SHORTLY AFTER TAKEOFF ROLL STARTED. BIT CHECKED ANTI-SKID CONTROL BOX, FOUND NR 2 MAIN ANTI-SKID WHEEL SPEED TRANSDUCER HAD FAILED. REMOVED AND REPLACED NR 2 MAIN WHEEL SPEED TRANSDUCER PER MM 3SDR DLM90982612Skin · gougedFUSELAGE SKIN FS 297-313 L-23R, DENT/GOUGE REPAIR. THE FUSELAGE SKIN AT LONGERON 23R WAS GOUGED AND DENTED BETWEEN FS 297 AND 313. THE DAMAGED AREA OF SKIN WAS CUTOUT WITH A 28 LONG BY 2 WIDE CUTOUT. THE DAMAGE WAS REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLESDR DLM90982594Angle · crackedFUSELAGE ATTACH FITTING, VERTICAL STAB TO FUSE ANGLE, REPAIR FOR CRACK. THE VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE WAS FOUND WITH A .75 CRACK BETWEEN FASTENERS AT FS 940 ON THE LT SIDE OF THE FUSELAGE. THE CRACKED AREA WAS ROUTED OUT OF THE ANGLE ASDR ORJA98314Eec · malfunctionedIN SJC - AT 40-50 KNOTS ON TAKEOFF ROLL AUTO THROTTLES ON, ENGINES SPOOLING UP AT 1.35 EPR ON LEFT AND RIGHT. RIGHT ENGINE THEN STARTED TO SPOOL DOWN (ROLL BACK). TAKEOFF WAS DISCONTINUED. REMOVED AND REPLACED NR 2 ENGINE EEC IAW MM 73. PERFORMED OPERATIONSDR ORJA98308Controller · malfunctionedIN RNO - AFTER TAKEOFF, ROLL 6 FT PNEU SYSTEM FAULT REJECTED TAKEOFF RETURN TO GATE. RAN BIT TEST ON PNEU SYSTEM CONTROLLER, NO FAULTS NOTED SYSTEM FAULT CLEARED MESSAGE CLEARED. (M)SDR DLM90982422Skin · puncturedTHE FUSELAGE SKIN WAS PUNCTURED BY A JETWAY JUST BELOW THE LONGERON 18L CUSP LINE AT FS 230. THE DAMAGED SKIN WAS TRIMMED AWAY AND REPAIRED WITH AN EXTERNAL REPAIR DOUBLER PER THE GUIDELINES OF THE MD-90 SRM 53-30-01, FIG 3. THE REPAIR AND INSPECTION REQUIRESDR DLM90981980Slide · deployedR1 DOOR SLIDE ACCIDENTLY DROPPED OUT OF DOOR CRADLE AND DEPLOYED. REPLACED DOOR SLIDE PER M/M.SDR DLM90981962Air Distribution · odorELECTRICAL FUMES SMELLED IN COCKPIT AND AFT CABIN DURING DESCENT. NO SMOKE WAS SEEN. THE SMELL CAME AND WENT TWICE. NOT DETECTABLE AFTER LANDING. INSPECTED CABIN LIGHTING, OPERATED APU AND PACKS AND BOTH ENGINES. GALLEY POWER, VIDEO, ENTERTAINMENT SYSTEMSDR ORJA98216Control Unit · failedAT RENO, ANTI-SKID FAULT. REMOVED AND REPLACED BRAKE CONTROL UNIT IAW MM 32-00. MAINTENANCE TAXI TEST FOUND NO FAULTS OR DISCREPANCIES. SYSTEM OPS CHECK NORMAL AND OK FOR SERICE. REF ORJA98215. (M)SDR DLM90981816Pos Transmitter · inoperativeAT CRUISE, ELEVATOR SPLIT LIGHT ILLUM ON OAP/ DFGC IN NR 1 WAS ON AND LEVEL AT CRUISE, NO PITCH INPUT FOR 5 MINS. FOUND RT ELEVATOR POS TRANSMITTER INOP. REPLACED TRANSMITTER, CK GOOD PER M/M.SDR DLM90981689Fire Loop · failedAFTER TAKEOFF, RIGHT ENGINE FIRE LIGHT FLICKERS. ON SHORT, FINAL FIRE WARNING 4 TIMES UNTIL LANDING. REPLACED ELEMENT.SDR DLM90981662Bulb · failedLEFT OVERWING EMERGENCY EVACUATION LIGHT FAILED TO TEST ON LAYOVER CHECK. RELAMPED, TESTS GOOD.SDR DLM90981659Skin · dentedTHE FUSLEAGE SKIN AT FS 1353 WAS DENTED AND CREASED BETWEEN STRINGERS 28L AND 28R. STRINGER 29L WAS ALSO DENTED. THE SKIN DAMAGE WAS REMOVED WITH A 18.75 X 20.75 CUTOUT AND A 4 INCH SECTION OF THE DAMAGED STRINGER WAS REMOVED. THE SKIN WAS REPAIRED WITH AN SDR DLM90981631Tire · failedNR 3 MAIN TIRE LOST TREAD DURING T/O ROLL, LEFT GEAR EXTENDED. RETURNED FOR UNEVENTFUL LANDING. RECAP SEPARATED FROM TIRE CAUSING EXTENSIVE DAMAGE TO RT I/B FLAP AND NR 2 ENGINE.SDR DLM90981581Cables · locked upON FINAL IN LANDING CONFIGURATION CONTROL COLUMN LOCKED APPROX 6 INCHES FWD OF NEUTRAL AIRSPEED 145 TO 150 KNOTS COLUMN WAS FORCEFULLY PUSHED FORWARD. RELEASE OCCURRED, BUT LOCKED ON A SECOND TRY COULD NOT DUPLICATE ON THE GROUND. REMARKS- AS OF 2130E/30 ITESDR ORJA98139Bracket · damagedMAINTENANCE DISCOVERED ON NR 1 ENGINE AT NR'S 2, 16, AND 20 POSITIONS, THE FUEL NOZZLE BRACKETS WERE LOOSE DUE TO ELONGATIONS OF THE BOLT HOLES. MAINTENANCE REPLACED THE BRACKETS. AIRCRAFT RETURNED TO SERVICE. NOTE: FUEL NOZZLES HAVE NEVER BEEN REPLACED. SDR ORJA98138Brackets · damagedMAINTENANCE DISCOVERED ON NR 1 ENGINE, AT NR'S 2, 16, AND 20 POSITIONS. THE FUEL NOZZLE BRACKETS WERE LOOSE DUE TO ELONGATIONS OF THE BOLT HOLES. MAINTENANCE REPLACED THE BRACKETS. AIRCRAFT RETURNED TO SERVICE. NOTE: FUEL NOZZLES HAVE NEVER BEEN REPLACED.SDR ORJA98131Bracket · damagedMAINTENANCE DISCOVERED ON NR 2 ENGINE, NR 9 FUEL NOZZLE BRACKET LOOSE DUE TO ELONGATED BOLT HOLES. REMOVED AND REPLACED NR 9 FUEL NOZZLE BRACKETS. AIRCRAFT RETURNED TO SERVICE. NOTE: FUEL NOZZLES HAVE NEVER BEEN REPLACED. (X)SDR DLM90981367Generator · failedAT ALT C/P LIGHTS FLICKERED SEVERAL TIMES THEN GOT RT GEN OFF MSG ON OAP. ALSO, RT AC BUS OFF MSG. REPLACED RT GENERATOR CONVERTER CKS OK.SDR ORJA98140Bracket · damagedSJC - MAINTENANCE DISCOVERED NR 2 ENGINE AFT COWL LATCH DOOR HAS EVIDENCE OF HEAT DAMAGE. NR 2 ENG UPPER AND LOWER C-DUCTS HAVE DELAMINATION AND ARE DISBONDED BEYOND LIMITS. ACFT FERRIED TO RENO FOR REPAIR. UPON FURTHER INVESTIGATION, MAINT DISCOVERED THE FSDR ORJA98137Gasket · damagedSJC - MAINTENANCE DISCOVERED ON THE NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS WERE DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIRS. MAINT DISCOVERED THAT 2 EACH GASKETS (FUEL NOZZLE BRACKET GASKET) WERE DEFECTIVE AT THE NR 17 ANDSDR ORJA98136Bracket · damagedSJC - MAINTENANCE DISCOVERED ON NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. MAINTENANCE DISCOVERED THE FOLLOWING FUEL NOZZLE BRACKETS LOOSE DUE TO ELONGATION OF THE BOLT HOLES IN THE SDR ORJA98135Bracket · damagedSJC - MAINTENANCE DISCOVERED ON NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. MAINT DISCOVERED THE FOLLOWING FUEL NOZZLE BRACKETS LOOSE DUE TO ELONGATION OF THE BOLT HOLES IN THE BRACKESDR ORJA98134Bracket · damagedSJC - MAINTENANCE DISCOVERED ON NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. MAINT DISCOVERED THE FOLLOWING FUEL NOZZLE BRACKETS LOOSE DUE TO ELONGATION OF THE BOLT HOLES IN THE BRACKESDR ORJA98133Bracket · damagedSJC - MAINTENANCE DISCOVERED ON NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. MAINT DISCOVERED THE FOLLOWING FUEL NOZZLE BRACKETS LOOSE DUE TO ELONGATION OF THE BOLT HOLES IN THE BRACKESDR ORJA98132Bracket · damagedSJC - MAINTENANCE DISCOVERED ON NR 1 ENGINE, THE UPPER AND LOWER C-DUCTS DELAMINATED AND DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. UPON FURTHER INVESTIGATION, MAINT DISCOVERED THE FOLLOWING FUEL NOZZLE BRACKETS LOOSE DUE TO ELONGATION OF SDR ORJA98130Bracket · damagedSJC MAINTENANCE DISCOVERED NR 2 ENGINE AFT COWL LATCH DOOR HAS EVIDENCE OF HEAT DAMAGE. NR 2 ENGINE UPPER AND LOWER C-DUCTS HAVE DELAMINATION AND ARE DISBONDED BEYOND LIMITS. AIRCRAFT FERRIED TO RENO FOR REPAIR. MAINT DISCOVERED THE FOLLOWING FUEL NOZZLE BSDR ORJA98129Bracket · damagedSJC - MAINTENANCE DISCOVERED NR 2 ENGINE AFT COWL LATCH DOOR HAS EVIDENCE OF HEAT DAMAGE. NR 2 ENGINE UPPER AND LOWER C-DUCTS HAVE DELAMINATION AND ARE DISBONDED BEYOND LIMITS. AIRCRAFT 901RA WAS FERRIED TO RENO FOR REPAIR. UPON FURTHER INVESTIGATION, MAINTSDR ORJA98128Bracket · damagedSJC - MX DISCOVERED NR 2 ENG AFT COWL LATCH DOOR HAS EVIDENCE OF HEAT DAMAGE. NR 2 ENG UPPER AND LOWER C-DUCTS HAVE DELAMINATION AND ARE DISBONDED BEYOND LIMITS. A/C WAS FERRIED TO RENO FOR REPAIR. UPON FURTHER INVESTIGATION, MX DISCOVERED THE FOLLOWING FUESDR ORJA98127Bracket · damagedSJC - MX DISCOVERED NR 2 ENG AFT COWL LATCH DOOR HAS EVIDENCE OF HEAT DAMAGE. NR 2 ENG UPPER AND LOWER C-DUCTS HAVE DELAMINATION AND ARE DISBONDED BEYOND LIMITS. AIRCRAFT WAS FERRIED TO RENO FOR REPAIR. UPON FURTHER INVESTIGATION, MAINTENANCE DISCOVERED THASDR DLM90981216Angle · crackedLT FUSELAGE TO VERTICAL STABILIZER ATTACH ANGLE WAS FOUND CRACKED AT FS 940. THE CRACK MEASURED APPROXIMATELY 1 INCH LENGTH AND EXTENDED FWD/AFT IN THE FLANGE COMMON TO THE FUSELAGE BODY. THE CRACK WAS REPAIRED BY THE INSTALLATION OF A REPAIR DOUBLER PER ER/SDR ORJA98107Light · inoperativeEMERGENCY FLOOR TRACK LIGHT AT ROW 2 IS INOPERABLE. REMOVED AND REPLACED 2 EMERGENCY PATH LIGHT ASSEMBLIES. OPS CHECK GOOD. (X)SDR ORJA9899Epr · malfunctionedGATE RETURN DUE TO NR 1 EPR ROLLBACK TO 1.3 EPR. ABORT AT 80 KNOTS. MAXIMUM BRAKE TEMPERATURE, 320 DEGREES. INTERROGATED MCDU, NOTED NO FAULTS. PERFORMED 2 FULL POWER RUN-UPS. OPS NORMAL. VISUALLY INSPECTED AIR INLET AND FAN AREA. CHECKS OK. (X)SDR ORJA98106Charger · inoperativeBURNED ELECTRICAL THROUGHOUT FORWARD PART OF CABIN AND COCKPIT. REMOVED AND REPLACED TWO A/C BATTERIES IAW MM 24. REMOVED AND REPLACED BATTERY CHARGER UNIT IAW MM 24. (M)SDR 98ZZZM539Battery Pack · dischargedBURNED ELECTRICAL THROUGHOUT FORWARD PART OF CABIN AND COCKPIT. REMOVED AND REPLACED TWO A/C BATTERIES IAW MM 24. REMOVED AND REPLACED BATTERY CHARGER UNIT IAW MM 24. (M)SDR DLM90980846Sensor · malfunctionedAT 31,000 FT GOT PYLON FLAP MESSAGE FOLLOWED BY ELEVATOR SPLIT MESSAGE THEN PYLON FLAP MESSAGE WENT OUT. AIRCRAFT RETURNED TO DFW. REPLACED ACU AND RT ELEV POS SENSOR .SDR DLM90980869Angle · crackedFUSELAGE/ATTACH FITTING, VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE: REPAIR FOR CRACK. THE VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE ON THE LT SIDE OF THE AIRCRAFT WAS FOUND WITH A .90 CRACK AT FS 937. THE CRACKED FLANGE WAS TRIMMED OUT AND A .080 THICKSDR DLM90980828Generator · failedON CLIMBOUT PASSING 10,000 FT, APU AC PWR FAULT MSG ILLUMINATED. APU ABNORMAL COMPLIED WITH, APU GEN OFF AND APU MASTER SWITCH OFF. RETURNED TO DFW. REPLACED APU GEN. NO LEAKS, FAULTS, OR MSGS. OPN TEST GOOD. NOTE: LT ENG GEN ALREADY ON MCO.SDR ORJA9874Circuit Breaker · trippedRETURN TO GATE FOR LEFT GENERATOR OFF AND LIGHT A/C POWER FAULT ANNUNCIATED. PULLED AND RESET CIRCUIT BREAKERS ON DC POWER ISOLATION UNIT. ENGINE RUN AND LEFT GENERATOR CAME ON-LINE AND OPS CHECK. (X)SDR DLM90980803Bearing · looseON DEPARTURE PUSHBACK, GROUND CREW HEARD LOUD NOISE FROM THE RIGHT MAIN GEAR. FOUND NR 4 MAIN WHEEL INNER BEARING RACE LOOSE IN WHEEL CASTING. REPLACED WHEEL ASSY.SDR ORJA9876Wire · failedEMERGENCY FLOOR TRACK LIGHTING ONE LAMP INOP AT ROW 8. FOUND BROKEN WIRE. RECONNECTED, OPS CHECK GOOD. (M)
Back to Boeing MD-90-30