Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 20000518SH011Bearing · failedGEARBOX REMOVED FOR METAL IN CHIP COLLECTOR AND STRAINER. DISASSEMBLY, INSPECTION DISCLOSED BEARING (CAGE) FAILURE. MATERIAL FORWARDED TO IAE ENGINEERING FOR REVIEW. (X)Mar 8, 2000 · Doug MD9030 · Turbine Engine Accessory DriveSDR AALA006046Wire · disconnectedSNA-CCI - AFT EMERGENCY LIGHT ASSY INOPERATIVE. FOUND WIRES DISCONNECTED TO EMERGENCY LIGHT ASSY, REATTACHED WIRES. OPS CHECK GOOD. (M)Mar 7, 2000 · N901RA · Doug MD9030 · Light System WiringSDR AALA006044Wire · disconnectedSNA-CCI - EMERGENCY EXIT LIGHT AT AFT VENTRAL STAIR INOPERATIVE. FOUND WIRES DISCONNECTED, RECONNECTED WIRES OPS CHECK OK. (M)Mar 7, 2000 · N903RA · Doug MD9030 · Light System WiringSDR AALA006039Relay · failedSNA - AT 11,000 FEET ON CLIMB-OUT, LOST CAPTAINS INSTRUMENTS AND HAD OVERSPEED WARNING, RAPID CLICKING BEHIND CAPTS SEAT, F/O HAD ONLY AIRSPEED AND ALTITUDE INDICATION. EPR WAS ONLY ENG INDICATION, RETURNED TO VFR TO SNA. ON LANDING, NO AUTO SPOILER NO REVERMar 2, 2000 · N902RA · Doug MD9030 · AC Generator-AlternatorSDR AALA006038Socket · failedSNA - ROW 18 EMERGENCY FLOOR LIGHT INOPERATIVE. REQUIRES LAMP SOCKET P/N 08169-01 PARTS NIS SNA. DEFERRED PER MEL. ENTERED IN MICS DMI NR 21568. (M)Feb 24, 2000 · N904RA · Doug MD9030 · Emergency LightingSDR DLM90000316Filter · dirtyRIGHT GEN OIL FILTER MSG ILLUMINATED ON T/O ROLL. T/O WAS DISCONTINUED. FWD VSCF TO MAO AND PLACARD. VSCF GEN FILTER CHECKED PER MEL 24-12-02A ONCE EA FLT DAY.Feb 15, 2000 · N909DA · Doug MD9030 · AC Generator-AlternatorSDR AALA006006Warning Light · illuminatedSFO - DURING TAKEOFF AT 60 KNOTS, TAILCONE LIGHT ILLUMINATED AND CAPTAIN ABORTED TAKEOFF. RESET TAILCONE LOCK SWITCH PIN AND LANYARD AND CLEARED UNSAFE ANNUNCIATION. (M)Jan 7, 2000 · N901RA · Doug MD9030 · Aerodynamic FairingsSDR AALA006005Cord · misroutedRNO - FIRST OFFICER'S OXYGEN MASK UNUSABLE DUE TO MIC CORD BEING MISROUTED THROUGH CONNECTING HOSES. RE-ROUTED MIC CORD, OPS CHECK GOOD. (X)Jan 3, 2000 · N904RA · Doug MD9030 · Crew Oxygen SystemSDR AALA996058Blade · failedSFO - LEFT ENGINE EXPERIENCED OFF IDLE COMPRESSOR STALLS DESCENDING THROUGH 30,000 FEET. NO ABNORMAL INDICATING NOTED EXCEPT ENGINE WOULD NOT ACCELERATE AT LOWER ALTITUDE. ENGINE RESPONDED NORMALLY IN ALL RESPECTS. REMOVED AND REPLACED NR 1 ENGINE PER CARDSDec 28, 1999 · N904RA · Doug MD9030 · Turbine SectionSDR DLM90992757Panel · separatedON ARRIVAL DFW FOUND NR 2 ENGINE C-DUCT ACCESS PANEL BLOWOUT DOOR MISSING. UPPER C-DUCT COWL DAMAGED BY DOOR. REPLACED UPPER REVERSER HALF AND RIGGED PER MM 78-32-00. REPLACED AND ADJUSTED BLOWOUT DOOR.Dec 14, 1999 · N911DA · Doug MD9030 · Nacelle/Pylon, Plate/SkinSDR AALA996045Engine · malfunctionedSNA - FLT 2827 - SJC-SNA - STARTING DESCENT FROM FL370, FELT SEVERAL JOLTS AS THE THROTTLES CAME BACK (COMPRESSOR STALLS). ALSO, FLIGHT ATTENDANTS REPORTED LOUD BANGS HEARD FROM THE RIGHT ENGINE. ALL ENGINE INSTRUMENTS INDICATED NORMAL. REMOVED ENGINE P/N V2Nov 30, 1999 · N904RA · Doug MD9030 · Engine (Turbine/Turboprop)SDR AALA996044Light · inoperativeRNO - ROW 28D EMERGENCY PATH LIGHT INOPERATIVE TRACK P/N 08163-0741-26. REPLACED LIGHT SOCKET. OPS CHECK GOOD. (M)Nov 24, 1999 · N905RA · Doug MD9030 · Emergency LightingSDR DLM90992583Light · inoperativeEMERGENCY TRACK LIGHTING AT SEATS 32-37 INOP. FOUND FAULTY WIRE SPLICES AT SEAT 33. INSTALLED PROPER SPLICE, OPS CK GOOD.Nov 22, 1999 · N905DA · Doug MD9030 · Emergency LightingSDR DLM90992474Power Supply · inopR1 DOOR OVERHEAD EMERGENCY EXIT LIGHT INOP. REPLACED POWER SUPPLY.Nov 9, 1999 · N909DA · Doug MD9030 · Emergency LightingSDR AALA6027Anti-Ice Valve · failedSJC - DURING CLIMB-OUT, AIR FOIL ANTI-ICE WAS TURNED ON. CABIN IMMEDIATLEY STARTED A CLIMB. FLOW LIGHT CAME ON, AND CABIN AIR BECAME HOT AND SMOKEY. LEVELLED AT 21,000 FEET AND SYSTEM RETURNED TO NORMAL. PERFORMED HIGH POWER ENGINE RUN. FOUND WING ANTI-ICEOct 27, 1999 · N902RA · Doug MD9030 · Airfoil Anti/De-ice SystemSDR AALA996030Lights · failedSNA - READING LIGHTS SEAT 9AC EXTREMELY HOT, AND SMOKE OBSERVED BY FLT ATTENDANT. REPLACED 9A AND 9C READING LIGHTS. OPS CHECK NORMAL. NO SMOKE NOTED. (M)Oct 21, 1999 · N903RA · Doug MD9030 · Passenger Compartment LightingSDR DLM90992290Wire · shortedPASSING 28,000 STATUS LT AND RT ENG SYSTEM FAIL MESSAGE CAME ON. ENG WENT INTO N1 DEFAULT MODE. EPR AND EPR LIMIT INDICATIONS WENT AWAY AND AUTO THROTTLES DISENGAGED. FOUND WIRE 4 INCH AFT OF DISCONNECT P1-8066 GOING TO P1-8078 T2 CHANNEL A SHORTED TO ENG Oct 18, 1999 · N903DA · Doug MD9030 · Instrument System WiringSDR AALA996024Battery Pack · dischargedSNA - MAIN ENTRANCE EMERGENCY EXIT SIGN LIGHT OUT, BATTERY CHARGER INOPERATIVE. REPLACED BATTERY PACK POWR SUPPLY. OPS CHECK NORMAL. (M)Oct 14, 1999 · N901RA · Doug MD9030 · Emergency LightingSDR AALA996025Charger · failedSNA - 1ST CLASS FLOOR E-LIGHTS INOPERATIVE. REMOVED AND REPLACED E-PACK CHARGING UNIT. OPS CHECK GOOD. (M)Oct 13, 1999 · N901RA · Doug MD9030 · Emergency LightingSDR DLM90992244Harness · damagedLEFT ENGINE FIRE WARNING ON T/O. FIRE BOTTLE DISCHARGED. A/C RETURNED TO BLOCKS, B-LOOP CORE HARNESS BAD, A-LOOP CHECKED GOOD.Oct 8, 1999 · N910DN · Doug MD9030 · Detection SystemSDR DLM90992189Valve · inopLT PACK FLOW OF ABOUT 20 PERCENT FLOW LIGHT ON FROM T/O TO 10,000. NO CHANGE IN FLOW PERCENT. RATE OF A/C CLIMBING SLOWED TO 1000 PPM, STILL HAD FLOW LITE. REPLACED LT PACK FLOW CONTROL VALVE. A/C PRESSURIZED GOOD.Oct 2, 1999 · N904DA · Doug MD9030 · Cabin Cooling SystemSDR AALA996017Power Supply · inoperativeEMERGENCY FLOOR TRACK LIGHTING INOPERATIVE IN FIRST CLASS. REPLACED B5-240 POWER SUPPLY, CHECK GOOD. (M)Sep 30, 1999 · N901RA · Doug MD9030 · Emergency LightingSDR DLM90992169Gcu · failedAT 31K FT APU GEN TRIPPED OFF LINE, RT ENG GEN ON MCO. A/C RETURNED. REPLACED APU GCU.Sep 28, 1999 · N911DA · Doug MD9030 · AC RegulatorSDR DLM90992157Flashlight · inopONE OF TWO EMERGENCY FLASHLIGHT AT FORWARD F/A STATION NOT BLINKING. REPLACED FLASHLIGHT ASSY AND BATTERY.Sep 27, 1999 · N909DA · Doug MD9030 · Emergency LightingSDR AALA996011Battery · dischargedSJC - EMERGENCY ESCAPE LIGHTS ROWS 28 AND AFT INOPERATIVE. REMOVED AND REPLACED AFT BATTERY PACK PER MM, OPS CHECK NORMAL. (M)Sep 21, 1999 · N905RA · Doug MD9030 · Emergency LightingSDR AALA996006Fail Light · illuminatedRNO - AUTO SLAT SPOILER FAIL LIGHT CAME ON DURING TAKEOFF ROLL AT 65 KNOTS. TRANSFERRED TO DMI NR 18690 PER MEL 27-62-01 OPTION 1 PULLED CB 37-243 MANUAL USE ONLY. (M)Sep 21, 1999 · N904RA · Doug MD9030 · Drag Control SystemSDR DLM90992104Brake · damagedWHEN REPLACING NR 3 MAIN TIRE FOUND BRAKE DAMAGED. REPLACED NR 3 MAIN BRAKE ASSY PER M/M. SEVERAL ROTOR TABS BROKEN AND ROTOR DISC DAMAGED.Sep 19, 1999 · N916DN · Doug MD9030 · Landing Gear Brake SystemSDR DLM90992000Compressor · stalledLT ENG COMPRESSOR STALLED ON TAKEOFF. REPLACING LT ENGINE.Sep 8, 1999 · N911DA · Doug MD9030 · Turbine Engine Compressor SectionSDR DLM90991990Power Supply · inopFIRST CLASS EMERGENCY FLOOR TRACK LIGHTING INOP. REPLACED POWER SUPPLY AND BATTERY.Sep 7, 1999 · N903DA · Doug MD9030 · Emergency LightingSDR DLM90991963Acm · seizedSTRONG UNIDENTIFIED ODOR IN COCKPIT AND CABIN RETURN TO DFW. FOUND LT ACM SEIZED, REPLACED ACM OPN NOW NORMAL.Sep 3, 1999 · N903DA · Doug MD9030 · Cabin Cooling SystemSDR DLM90991952Brake · draggingAFTER TAKEOFF, LEFT OUTBOARD BRAKE TEMP REACHED 700 DEG. EXTENDED GEAR AND BRAKE COOLED TO 400 DEG. THEN RETRACTED GEAR FOLLOWED POM PROCEDURES. REPLACED BOTH NR 1 AND NR 2 MAIN WHEEL ASSY PER M/M DUE TO NR 1 MAIN FLAT WHEN REACHING GATE. ALSO, CHANGED NRSep 2, 1999 · N907DA · Doug MD9030 · BrakeSDR AALA996004Cover · looseSNA - AFT SERVICE DOOR SLIDE COVER IS LOOSE. SERVICED SLIDE COVER CHECKS OK. (M)Sep 1, 1999 · N904RA · Doug MD9030 · Emergency EquipmentSDR DLM90991781Generator · failedRT GEN FAILED DURING INITIAL TAKEOFF ROLL AT 70KTS OAP MESSAGE RT ELEC SYSTEM FAIL. EPCU FAULTS CEU. REPLACED CEU RAN ENGINE. A/C POWER SYSTEM CHECK GOOD.Aug 9, 1999 · N905DA · Doug MD9030 · AC Generator-AlternatorSDR DLM90991709Wire · brokenEMERGENCY LIGHTING CEILING INOP. FOUND BROKEN WIRES IN CEILING REPAIRED WIRES. OPS NORMAL.Jul 29, 1999 · N902DA · Doug MD9030 · Light System WiringSDR DLM90991706Convertor · failedL AC PWR FAULT AND L GEN OFF MSG ON OAP. APU IS ON MCO/PLAC. PER EPCU BITE, REPLACED LEFT A/C CONVERTER. OPS CKS NORMAL.Jul 29, 1999 · N907DA · Doug MD9030 · AC Generation SystemSDR ORJA99241Cover · missingEMERGENCY LIGHT AND COVER MISSING. REPLACED EMERGENCY LIGHT AND COVER, ROW 23, PER MM 33-53-00. OPS CHECK GOOD. (M)Jul 26, 1999 · N905RA · Doug MD9030 · Emergency LightingSDR AALA996029Wire · brokenOKC - EMERGENCY FLOOR TRACK LIGHTING FAILED STEP B.1 WIRES BROKEN AT LIGHT ASSY ROW 1 FORWARD LIGHT. REPLACED BULB AND REPAIRED BROKEN WIRES IAW MD-90 MM 20-50-01. OPS CHECK GOOD IAW C-CHECK CARD NR 1C-114 STEP B.1. (M)Jul 17, 1999 · N901RA · Doug MD9030 · Light System WiringSDR AALA996028Wire · pinchedOKC - EMERGENCY FLOOR TRACK LIGHTING FAILED STEP H 1. REPAIRED PINCHED WIRE IN FLOOR TRACK SYSTEM. OPS CHECK NORMAL IAW MD-90 MM 20-10-03. OPS CHECK GOOD IAW C-CHECK CARD 1C-114 STEP H. 1. (M)Jul 17, 1999 · N901RA · Doug MD9030 · Light System WiringSDR DLM90991524Battery · dischargedFOUND EMERGENCY OVERHEAD LIGHTS OUT IN F/C. REPLACED BATTERY PACK. OPS NORMAL.Jul 6, 1999 · N916DN · Doug MD9030 · Emergency LightingSDR DLM90991506Bulb · failedON LANDING DFW PLACED GEAR HANDLE DOWN AND HAD NO GREEN LIGHT ON RIGHT MAIN. FOLLOWED CHECK LIST PER POM. FOUND BOTH BULBS INOP. RELAMPED SAME. SIMULATED GEAR SWING USING SLUGS, ALL CHECK NORMAL.Jul 3, 1999 · N908DA · Doug MD9030 · Landing Gear Position and WarningSDR DLM90991491Power Supply · inoperativeEMERGENCY LIGHTS CAME ON ROW 38 DURING T/O. REPLACED DEFECTIVE POWER SUPPLY.Jul 1, 1999 · N914DN · Doug MD9030 · Emergency LightingSDR ORJA99209Wire · brokenRNO - EMERGENCY PATH LIGHT AT ROW 33 IS INOPERATIVE. REPLACED BROKEN WIRE ON ROW 31 EMERGENCY EXIT LIGHT SYSTEM, OPS CHECK GOOD. (M)Jun 28, 1999 · N901RA · Doug MD9030 · Light System WiringSDR DLM90991460Slide · unserviceableL1 DOOR SLIDE REMOVED FOR DOOR MTC AND SLIDE COVER LATCH WOULD NOT RELEASE AND AFTER SLIDE COVER OPENED FOUND PIN PULLED OUT. REPLACED SLIDE PACK.Jun 28, 1999 · N902DA · Doug MD9030 · Escape SlideSDR ORJA99208Battery Pack · dischargedSJC - FORWARD ENTRY DOOR EXIT E-PATH LIGHTS BATTERY PACK B5-234 HAS BLOWN INTERNAL FUSE. REMOVED AND REPLACED FORWARD ENTRY E-PATH LIGHT BATTERY PACK, OPS CHECK GOOD. (M)Jun 26, 1999 · N903RA · Doug MD9030 · Emergency LightingSDR ORJA99219Battery Pack · dischargedSJC - FIRST CLASS CABIN EMERGENCY EXIT FLOOR LAMP INOPERATIVE. FOUND SHORT BULB AT 4DEF WHICH BLEW A FUSE AT BATTERY PACK B5-240. REMOVED AND REPLACED BULB AND BATTERY PACK IAW MM 33. E.PAN LIGHTNING OPS CHECK GOOD. (X)Jun 25, 1999 · N903RA · Doug MD9030 · Emergency LightingSDR DLM90991262Battery Pack · dischargedR1 DOOR EMERGENCY EXIT LIGHTS VERY DIM. REPLACED BATT PACK, OPS NOW OK.Jun 4, 1999 · N903DA · Doug MD9030 · Emergency LightingSDR DLM90991197Coalescer Bag · dirtyOILY SMELL FROM AIR CONDITION SYSTEM AFTER TAKEOFF. REMOVED ACCESS PANEL AND INSULATION BARRIER FOR H2O SEPARATOR BAGS. REPLACED H2O SEPARATOR BAGS, RUN LEAK CK AND OPERATIONAL NORMAL. REINSTALLED PANELS. CHECKED A/C AND APU FOR LEAKS, CHECKED OK. CLEANEDMay 27, 1999 · N908DA · Doug MD9030 · Humidity Control SystemSDR ORJA99171Battery Pack · dischargedSJC - FOUND EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK IW 33-5117. OPS CHECK GOOD. (M)May 10, 1999 · N901RA · Doug MD9030 · Emergency LightingSDR ORJA99159Valve · failedSJC - ABORTED TAKEOFF, ON TAKEOFF ROLL, LEFT PNEUMATIC SYSTEM FAULT ON EOAP THROUGH 80 KNOTS. REMOVED AND REPLACED LEFT PRESSURE REGULATING PILOT SHUTOFF VALVE IAW MM 36-12-03. OPS CHECK GOOD. (M)Apr 27, 1999 · N901RA · Doug MD9030 · Pneumatic Distribution SystemSDR DLM90991408Angle · crackedTHE LT VERTICAL STABILIZER-TO-FUSELAGE ATTACH ANGLE WAS FOUND WITH A 1.5 INCH LONG CRACK AT FS 1520. THE CRACK IS TYPICAL OF THAT FOUND IN MD-88 SRM 53-05, FIG 23. THE CRACKED HORIZONTAL FLANGE WAS CUTOUT AND REPAIRED WITH A STEEL ANGLE FABRICATED FROMMar 20, 1999 · N912DN · Doug MD9030 · Fuselage Miscellaneous Structure
Back to Boeing MD-90-30