Douglas DC-8-62

Service difficulty reports · 2,778

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC862'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA001714Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001713Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C4-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001706Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001696Structure · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK BEHIND LT NOSE LANDING GEAR DOOR ON FUSELAGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED DOUBLER FROM 7075-T6 AND INSTALMar 27, 2000 · N994CF · Doug DC862 · Fuselage Main, StructureSDR RRXA001694Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001679Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 811Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001661Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C1-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY FILL WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001648Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C9-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001635Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001634Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000930Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C5-R13, DAMAGED EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000926Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. NR 99-236 WITH APPROVED 8110-3 DATE 3-6Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000845Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C8-R8), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED ALL DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 8110-3 DATED 3-Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000842Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C3-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000836Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C1-R7) 12 INCHES FROM EDGE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NRMar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001722Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL O1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001721Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGH FLOOR PANEL, LARGE HOLE WITH CRACK AT ABOUT CENTER OF FLOOR PANEL AND LARGE DENT WITH CRACK ABOUT 2 INCHES FROM EDGE C2-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATEDMar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001717Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001711Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C12-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 399-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001710Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001708Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C8-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001678Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL FLOOR PANEL DISCREPANT HOLES PER E.O. 99-236 WITH AMar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001677Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL FLOOR PANEL DISCREPANT HOLES PER E.O. 99-236 WITH APMar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001662Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C13-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IN FLOOR PLANKS PER WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000927Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBOARD C14-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED FLOOR PLANK, FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APMar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000843Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C9-R6), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, FILLED ALL DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 81Mar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000835Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C9-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES BY FILLET WELDING IAW EO NR 99-236 WITH APPROVED 8110-3 DATEMar 26, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001720Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS HOLES IN FLOOR PANEL C9-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001716Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT C1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY FILLET WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001709Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND WORN DRILLED HOLE AREA ON FLOOR PANEL ALSO NUMEROUS DRILLED HOLES ON FLOOR PANEL C12-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PMar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001707Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND DRILLED HOLES CLUSTERED TOGETHER C14-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001676Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 811Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001642Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANAT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001641Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001636Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DMar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000932Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000844Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C2-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, FILLED ALL DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 81Mar 25, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000915Frame · misdrilledDURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED AT STA 300 AND L2L TO L4L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM.Mar 21, 2000 · N994CF · Doug DC862 · Fuselage Main, FrameSDR RRXA000725Panel · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LT WING LWR WING PANEL AT STA XRS 351, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW WING T/E PANEL IAW DC-8 SRM 51-3-0 AND 51-1-21Mar 21, 2000 · N994CF · Doug DC862 · Wing, Plate/SkinSDR RRXA000994Stiffener · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE ON THE STIFFENER AROUND EXTERNAL POWER SOURCE WIRES AT STA 198 TO 204, RBL 69 TO 61, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SMar 17, 2000 · N994CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA000990Structure · damagedDURING A MAINTENANCE VISIT, FOUND ELONGATED SCREW HOLES LT WING IB LE LWR. SURFACE AT STA XFS 107 TO 113, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. SCREW HOLES ARE WITHIN ALLOWABLE CRITERION IAW E.OMar 17, 2000 · N994CF · Doug DC862 · Leading Edge DevicesSDR RRXA000877Skin · crackedDURING A MAINTENANCE VISIT FOUND AN ENLARGED AND ELONGATED SCREW HOLE ON THE LT WING O/B SLOT LE I/B END AT STA XS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.Mar 17, 2000 · N994CF · Doug DC862 · Leading Edge DevicesSDR RRXA000876Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK EMANATING FROM A SCREW HOLE LT WING CENTER LE AT O/B SLOT LE AT STA XS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.Mar 17, 2000 · N994CF · Doug DC862 · Leading Edge DevicesSDR RRXA000875Skin · damagedDURING A MAINTENANCE VISIT FOUND TEN ELONGATED SCREW HOLES IN THE UPPER AFT MOUNTING NR 1 STUB WING AT XS 520 TO XFS 566.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLER FMar 17, 2000 · N994CF · Doug DC862 · Wing, Plate/SkinSDR ABXA000154Cable · contaminatedON GEAR EXTENTION AT SAN, THE GEAR HANDLE WAS VERY HARD TO EXTEND PAST THE MIDPOINT. DID NOT GET THREE GREEN LIGHTS. RECYCLED GEAR, LIGHTS OK. PERFORMED GEAR SWING IAW DC9 MM 32-31-00. ALL GEAR DOORS FAIRED AND ALL GEAR INDICATION WAS NORMAL. SUSPECT ICE Mar 17, 2000 · N804AX · Doug DC862 · Landing Gear Retraction/Extension SystemSDR RRXA002387Attach Angle · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN ATTACH ANGLE AT STA 1568 AND L24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-4 AND 51-3-0.Mar 14, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002386Attach Angle · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN ATTACH ANGLE AT STA 1568 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-4 AND 51-3-0.Mar 14, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA001688Vane · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE RT WING OB FLAP VANE BETWEEN CENTER AND OB HINGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW RT WING OB FLAP VANE IAW DCMar 14, 2000 · N994CF · Doug DC862 · Trailing Edge FlapsSDR RRXA001669Longeron · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FUSELAGE AT STA 1500 TO 1520 AND LONGERON 24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED LONGERON AND INSTALLED PER E.O. 99-Mar 14, 2000 · N994CF · Doug DC862 · Fuselage Main, Longeron/StringerSDR RRXA000839Floor Support · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE CABIN SUB FLOOR STA 225 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SUB FLOOR IAW DC-8 SRM 53-2-0 AND EMar 14, 2000 · N994CF · Doug DC862 · Fuselage Miscellaneous Structure
Back to Douglas DC-8-62