Douglas DC-8-62

Service difficulty reports · 2,778

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC862'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA000823Seat Track · damagedDURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE MAIN CABIN UPPER CARGO COMPT SEAT TRACK C4-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. DISCREPANT HOLES WITHIN ALLOWABLE LIMITS IAW DC-8 SApr 4, 2000 · N994CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000822Seat Track · wornDURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C1-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED TRACK FROM 60-12809 AND INSTALLED IAW DC-8 SRApr 4, 2000 · N994CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000821Seat Track · misdrilledDURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C2-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED TRACK FROM 60-12809 AND INSTALLED IAW DC-8 SApr 4, 2000 · N994CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002247Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE FRAME AT STA 1480 RT AT L2R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21 AND 51-1-4.Apr 3, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002326Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL AND MISSING FASTENERS AT FS 1300 TO 1320 AND L4R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21Apr 1, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002405Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002372Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 28.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002371Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM AT STA 270 - 225 RT AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA02256Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE LONGITUDINAL FLOORBEAM AT RBL 28 1/2 10 BETWEEN STA 270 - 225 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002313Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERIOR WEB ON THE R-1 DOOR AT STA 395 RT AND L18R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 52-2-0, 51-1-Mar 31, 2000 · N995CF · Doug DC862 · Passenger/Crew DoorsSDR RRXA000831Skin · damagedDURING A MAINTENANCE VISIT, FOUND TWO SCREWS NOT INSTALLED IN RT WING L/E BETWEEN STA XFS 26.250 AND 63.750 (EO), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, INSTALLED FASTENERS IAW DC-8 SRM 51-1-20C AND EO NR 9Mar 31, 2000 · N994CF · Doug DC862 · Leading Edge DevicesSDR RRXA002329Attach Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED FLOORBEAM ATTACH FITTING AT FS 798 AND XCW 23 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0 AND 51-1-20D.Mar 30, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002230Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1060 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED L ANGLE IAW EO NR 00-047 WITH APPROVEDMar 30, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002319Panel · crackedDURING A MAINTENANCE VISIT FOUND MULTIPLE DRILLED HOLES AND CRACKS TO THE L2 CUSP PANEL AT STA 1480 TO 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DC-8 SRMar 29, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA000940Web · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE WEB AT THE WHEEL WELL IB SIDE AT STA 900 Z = -60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED DOUBLER FROM 2024-T3Mar 29, 2000 · N994CF · Doug DC862 · Fuselage Miscellaneous StructureSDR IXXA0000013Uplock · malfunctionedHIK - FLT JZ43 - EN ROUTE TO KWA, THE LANDING GEAR FAILED THE GEAR UPLATCH CHECK, ACCOMPANIED BY GEAR AND DOOR WARNING LIGHTS ILLUMINATING. THE FLIGHT CREW CYCLED THE GEAR BUT THE WARNING INDICATION REMAINED THE SAME. THE FLIGHT RETURNED TO HIK FOR AN UNEVENMar 29, 2000 · N8974U · Doug DC862 · Landing Gear Position and WarningSDR RRXA001724Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001718Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001715Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001712Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001695Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001689Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES DRILLED IN FLOOR PANEL C2-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001684Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001683Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001682Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001681Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001680Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001675Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 81Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001663Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C29-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001647Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 81Mar 28, 2000 · N994CF · Doug DC862 · Main Rotor BrakeSDR RRXA001646Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001645Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND A LARGE HOLE 9 INCHES FROM EDGE, 5 INCHES FROM OUTBOARD EDGE C12-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR PER E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001644Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-0Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001643Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001640Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001639Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C14-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001638Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001637Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000934Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C6-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000931Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C1-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000929Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C15-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000917Web · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE WEB IN THE LT WHEEL WELL IB SIDE STA 900 Z = -60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA000894Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C9 TO R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000841Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C15-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000837Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C12-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 811Mar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA000829Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8, FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DMar 28, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR ABXA000179Sensor · malfunctionedAFTER GEAR WAS RETRACTED AFTER T/O, THE NOT LATCHED LIGHT STAYED ON. GEAR HANDLE SELECTED TO UPLATCH CHECK POSITION GEAR STAYED UP AND NOT LATCHED LIGHTS STAYED ON. CHECKED LANDING GEAR DOOR AND GEAR LATCHING SELECTOR AND RIGHT GEAR DOOR NOT LATCHED LIGHT CAMar 28, 2000 · N804AX · Doug DC862 · Landing Gear Position and WarningSDR RRXA002267Attach Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE RT TANK EXTERIOR TO FLOORBEAM ATTACH FITTING AT FS 760=XCW 46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 5Mar 27, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA001723Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES ON FLOOR PANEL C12-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor PanelSDR RRXA001719Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES THROUGHOUT FLOOR PANEL C12-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-Mar 27, 2000 · N994CF · Doug DC862 · Fuselage Floor Panel
Back to Douglas DC-8-62