Douglas DC-8-62F
Service difficulty reports · 1,163
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR COOSDR040006Skin · corrodedFUSELAGE FWD SECTION Y STA 498 AND Y STA 522 LONGERON 34 RT LEVEL SKIN CORRODED.SDR COOSDR040005Strut · corrodedRT MLG SHOCK STRUT RETRACT PIN BOSS, INNER SURFACE CORRODED.SDR COOSDR040004Skin · crackedFUSELAGE NOSE SECTION, Y STA 215 FWD PASSENGER ENTRANCE DOOR, HOLD OPEN PIN-CUTOUT SKIN CRACKED.SDR COOSDR040003Door Frame · crackedMAIN CARGO CABIN Y STA 480 AFT JAMB BETWEEN LONGERON 21 LT AND LONGERON 19 LT, FRAME WITH WEAR AND CRACKED.SDR IXXA060448SSkin · wornDURING ROUTINE C CHECK, FOUND RIGHT WING SKIN WORN AT STATION XOLDO67. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060407SSkin · corrodedDURING ROUTINE C CHECK, FOUND LEFT WING LEADING EDGE LOWER SKIN CORRODED BETWEEN STATION XFS710 AND XFS635. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060406SSkin · corrodedDURING ROUTINE C CHECK, FOUND LEFT WING LEADING EDGE SKIN CORRODED BETWEEN STATION XW257 AND XW223. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060405SSkin · corrodedDURING ROUTINE C CHECK, FOUND LEFT WING UPPER SKIN CORRODED BETWEEN STATION XW0 AND XRS74. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060404SSkin · corrodedDURING ROUTINE C CHECK, FOUND LEFT WING LEADING EDGE SKIN CORRODED BETWEEN STATION XW257 AND XW408. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060403SSkin · corrodedDURING ROUTINE C CHECK, FOUND LEFT WING LEADING EDGE SKIN CORRODED BETWEEN STATION XW454 AND XW485. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060346SSupport Fitting · crackedDURING ROUTINE C CHECK, FOUND AIR CONDITIONING FLOORBEAM SUPPORT FITTING CRACKED AT STATION Y267, -X45. REPLACED FITTING PER ALL APPLICABLE DATA.SDR IXXA060344SSupport Fitting · crackedDURING ROUTINE C CHECK, FOUND AIR CONDITIONING FLOORBEAM SUPPORT FITTING CRACKED AT STATION Y253, +X45. REPLACED FITTING PER ALL APPLICABLE DATA.SDR IXXA060277SAngle · corrodedDURING ROUTINE C CHECK, FOUND ANGLE CORRODED AT STATION Y110, +Z3, +X48. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060386SSkin · corrodedDURING ROUTINE C CHECK, FOUND RIGHT ELEVATOR LOWER SURFACE SKIN CORRODED AT STATION XE32.398. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060385SBushing · corrodedDURING ROUTINE C CHECK, FOUND LEFT HORIZONTAL STABILIZER ELEVATOR SUPPORT BUSHING CORRODED AT STATION XE 140. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060384SFitting · crackedDURING ROUTINE C CHECK, FOUND LEFT HORIZONTAL STABILIZER SUPPORT FITTING CRACKED AT STATION XFS72 BETWEEN STRINGER 2 AND FRONT SPAR. REPLACED PER ALL APPLICABLE DATA.SDR IXXA060382SSkin · corrodedDURING ROUTINE C CHECK FOUND LEFT ELEVATOR INTERNAL FINGER DOUBLER AND SKIN CORRODED AT STATION XE38. REPAIRED PER ALL APPROVED DATA.SDR IXXA060383SSkin · bulgedDURING ROUTINE C CHECK, FOUND LEFT ELEVATOR TRAILING EDGE UPPER AND LOWER SKIN BULGED FROM STATION XE263 TO XE280. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060402SFitting · crackedDURING ROUTINE C CHECK, FOUND LEFT WING RIGHT CENTER FUEL TANK FITTING PLATE CRACKED AT STATION XWC23 BETWEEN STRINGERS 1 AND 2. REPLACED PER ALL APPLICABLE DATA.SDR IXXA060380SSkin · crackedDURING ROUTINE C CHECK, FOUND LEFT ELEVATOR LOWER SKIN CRACKED AND CORRODED FROM STATION XE137 TO XE181. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060377SSkin · corrodedDURING ROUTINE C CHECK FOUND RIGHT ELEVATOR LOWER SURFACE SKIN CORRODED AT STATION XE246. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060275SFrame · corrodedDURING ROUTINE C CHECK, FOUND FRAME CORRODED AT STATION 188 BETWEEN LONGERONS 3 RIGHT AND 11 RIGHT, ALSO 3 LEFT AND 11 LEFT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060376SSupport Fitting · crackedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER SUPPORT FITTING CRACKED AT STATION XFS72 BETWEEN STRINGERS 6 AND 7. REPLACED PER ALL APPLICABLE DATA.SDR IXXA060375SFitting · corrodedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER FRONT SPAR SUPPORT FITTING CORRODED AT STATION XFS72. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060374SSpar · crackedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER LOWER REAR SPAR CRACKED AT STATION XE40. REPAIRED PER ALL APPLICABLE DATASDR IXXA060373SHousing · crackedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER LINKAGE HOUSING CRACKED AT STATION XRS218. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060372SSupport · crackedDURING ROUTINE C CHECK FOUND RIGHT HAND HORIZONTAL STABILIZER LOWER SPAR CAP SUPPORT CRACKED AT STATION XFS62. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060371SSupport · crackedDURING ROUTINE C CHECK FOUND RIGHT HAND HORIZONTAL STABILIZER LOWER SECTION SUPPORT CRACKED AT STATION XFS47. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060370SStringer · crackedDURING ROUTINE C CHECK FOUND RIGHT HAND HORIZONTAL STABILIZER LOWER STRINGER CRACKED AT STATION XFS47. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060369SStrap · crackedDURING ROUTINE C CHECK FOUND RIGHT HAND HORIZONTAL STABILIZER CLOSING SPAR STRAP SCRATCHED AND CRACKED BETWEEN STATION XRS176 TO XRS215. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060366SHousing · crackedDURING ROUTINE C CHECK FOUND LINKAGE HOUSING CRACKED ON LEFT HAND HORIZONTAL STABILIZER AT STATION XRS136. REPLACED PER ALL APPLICABLE DATA.SDR IXXA060323SAngle · corrodedDURING ROUTINE C CHECK, FOUND LEFT SIDE VERTICAL STABILIZER TO FUSELAGE SKIN ATTACH ANGLE CORRODED AT STATION Y1606. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060387SSpar Cap · corrodedDURING ROUTINE C CHECK, FOUND RIGHT ELEVATOR LOWER SPAR CAP CORRODED FROM STATION XE32 TO XE285. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060368SPanel · bulgedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER TRAILING EDGE LOWER PANEL BETWEEN STATION XE221 TO XE149 BULGED. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060367SDoubler · bulgedDURING ROUTINE C CHECK FOUND DOUBLER BULGING AND CRACKED ON LEFT HAND HORIZONTAL STABILIZER AT STATION XRS250. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060365SPanel · bulgedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER TRAILING EDGE UPPER PANEL BETWEEN STATION XE221 TO XE272 BULGED AND RIVET SHEARED. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060364SCap · crackedDURING ROUTINE C CHECK FOUND LEFT HAND HORIZONTAL STABILIZER STATION XRS54 TEE CAP CRACKED. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060358SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y600 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060357SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y380 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060343SLongeron Splice · corrodedDURING ROUTINE C CHECK, FOUND LONGERON 24 RIGHT SPLICE CORRODED AT STATION Y406. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060276SFloor Support · corrodedDURING ROUTINE C CHECK FOUND FLOOR SUPPORTS CORRODED FROM STATION YT200 TO Y240, Z=0 BETWEEN +X40 AND -X40. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060274SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y1280 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060273SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y1120 AT LONGERON 14 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060272SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y902 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060271SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y860 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060270SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y834 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060269SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y781 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060268SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y500 AT LONGERON 14 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060267SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y660 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060266SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y600 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA
Back to Douglas DC-8-62F