SDR RRXA003304Link · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY IN THE LEFT O/B FLAP MID SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003303Link · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY TO THE LEFT O/B FLAP LWR SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003302Structure · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED CORNER AT RIVET HOLE TO THE RT MAIN GEAR DOOR FWD LWR END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003301Panel · delaminatedDURING A MAINTENANCE VISIT FOUND A DELAMINATED AND DETERIORATED PANEL 632 TOP AND O/B SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003300Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE BETWEEN STA 1080 - 1100 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR IXXA0000035Harness · misriggedENROUTE FROM DFW TO TOL, THE GEAR DOOR NOT LATCH WARNING LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. THE GEAR WAS CYCLED BUT THE WARNING INDICATION REMAINED THE SAME. THE FLIGHT RETURNED TO DFW FOR AN UNEVENTFUL LANDING. MAINTENANCE PERFORMED A GEAR SWINSDR RRXA003212Skin · dentedDURING A MAINTENANCE VISIT FOUND SEVERAL DING AREAS ON THE LEFT I/B FLAP BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003176Structure · wornDURING A MAINTENANCE VISIT FOUND A WORN EDGE ON THE AFT NR 2 ENGINE LT PYLON SKIRT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003175Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME LOWER CHORD IN -A- PIT AT STA 160 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003174Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME IN -A- PIT AT STA 180 AND L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003173Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND POPPED RIVETS AT BEAM LOWER CHORD/WEB AT STA 702 LBL 45 TO 52.5 & LBL 55.5 TO 61 Z AXIS -7 FWD AND AFT SIDE OF BEAM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003177Mount · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED FWD MOUNT ON THE NR 3 ENGINE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR IXXA0000034Uplock Target · looseEN ROUTE FROM TOL TO DFW, AFTER GEAR RETRACTION THE GEAR DOOR WARNING LIGHT REMAINED ILLUMINATED. THE FLIGHT CREW CYCLED THE LANDING GEAR, THE WARNING INDICATION REMAINED THE SAME. THE FLIGHT CONTINUED TO DFW FOLLOWING COMPANY PROCEDURES FOR AN UNEVENFUL LANSDR RRXA003180Bracket · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RIGHT I/B LWR SCISSOR PANEL SUPPORT BRACKET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003179Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN WEB WHERE WEDGE ATTACH POINT IS ON THE RIGHT I/B FLAP AT STA XW 75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003178Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION EXFOLIATION TO THE FLOORBEAM AT STA 702 AND X+50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR IXXA0000033Rod · out of adjEN ROUTE FROM TOL TO DFW, THE LANDING GEAR DOOR NOT LATCH LIGHT ILLUMINATED AFTER THE LANDING GEAR WAS RETRACTED. THE FLIGHT CREW CYCLED THE LANDING GEAR AND PERFORMED AN UNSUCCESSFUL UPLATCH CHECK. THE LANDING GEAR HANDLE WAS PLACED IN THE UP POSITION AND TSDR RRXA003099Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT WING O/B FLAP I/B FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003098Link · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE SUPPORT AFT LINK ON THE LEFT I/B FLAP SUPPORT AT STA 98 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003097Support Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED SUPPORT ON O/B AND I/B SIDES OF THE LEFT I/B FLAPS AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003096Stiffener · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED LEFT DUMP CHUTE UPPER SURFACE I/B SKIN STIFFENER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003095Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT O/B FLAP WELL I/B OF O/B ACTUATOR FRAME FOR SPOILER ATTACHMENT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003094Skin · puncturedDURING A MAINTENANCE VISIT FOUND A PUNCTURE TO THE LEFT WING CONTROL TAB ON I/B AILERON T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003093Link · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE LEFT I/B FLAP SUPPORT AFT LINK AT STA 98 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003092Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENTED I/B FLAP FAIRING AFT END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003091Skin · dentedDURING A MAINTENANCE VISIT FOUND SEVERAL DENTS IN A LARGE AREA O/B OF I/B SLOT DOOR AT STA XFS 250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003090Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED AND GOUGED HOLES ON THE FE''S LT SEAT TRACK LOCK HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003089Threshold · crackedDURING A MAINTENANCE VISIT FOUND GOUGED, CRACKED AND DOUBLER LOOSE ON THE D-PIT THRESHOLD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003088Threshold · gougedDURING A MAINTENANCE VISIT FOUND GOUGED, CRACKED AND SEPARATING SKIN ON THE B-PIT THRESHOLD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003087Seat Track · wornDURING A MAINTENANCE VISIT FOUND A WORN SEAT TRACK AT STA 1400 AND X+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003086Seat Track · wornDURING A MAINTENANCE VISIT FOUND A WORN FLOOR TRACK AT STA 1065 AND X=-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003085Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TAIL SECTION THROUGH DOOR NR 62 LT TAIL CONE AT BRACE AND SKIN ATTACHMENT AT STA 1930, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003108Skin · crackedDURING A MAINTENANCE VISIT FOUND A TORN, BENT AND CRACKED LOWER DOUBLER ON THE C-PIT DOOR DOUBLER AT STA 1160 - 1220 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003107Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK NEXT TO THE FUSELAGE ON THE RIGHT I/B FLAP WEB I/B, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003106Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FRAME AT ''D'' PIT AT STA 1400 AND L29R TO L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003105Panel · delaminatedDURING A MAINTENANCE VISIT FOUND A DELAMINATED PANEL BETWEEN MAIN GEAR DOORS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003104Skin · bulgedDURING A MAINTENANCE VISIT FOUND A LARGE BULGE TO THE I/B FLAP T/E AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003103Skin · gougedDURING A MAINTENANCE VISIT FOUND A LARGE GOUGE TO THE SKIN ON THE I/B FLAP P/B AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003102Access Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND DEFORMED ON THE I/B AILERON BOTTOM SIDE ACCESS PANEL FOR CONTROL TAB/POWER PACK TIE-IN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003101Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1390 LEFT AND X+45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003100Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1392 LEFT X+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003120Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1580 CENTER LINE AND X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003119Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A GOUGED AND WORN CARGO TRACK AT STA 1600 AND X+44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003118Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A GOUGED AND WORN CARGO TRACK AT STA 1680 LT AND X+22, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003117Skin · chafedDURING A MAINTENANCE VISIT FOUND A GOUGE AROUND SCREW HOLE ON L/E BOTTOM SIDE AT STA XFS 472, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003116Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON THE CORNER OF THE I/B AILERON I/B TAB T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003115Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1208 CENTER LINE AT X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003114Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1130 CENTER LINE AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003113Cargo Track · wornDURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1130 LEFT AND X+45, DAMAGE EXCEEDED LIMIITATIONS IAW DC-8 SRM.SDR RRXA003112Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CIRCUMFERENTIAL FRAME AND FITTING AT STA 1440 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
Back to Douglas DC-8-63F