Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA003197Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK FORMER AFT OF INTERCOSTAL BELOW SPLICE STRAP AT STA XFS 410.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR UPS00833859Longeron · corrodedINSPECTION TYPE:C1, STA 1705 LONG 30L IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED LONGERON IAW DWG 5649329, AND SRM 51-1-20D.SDR UPS00833858Shear Tie · corrodedINSPECTION TYPE:C1, STA 1760 LONG 28L - 28R 8 SHEAR TIES ARE CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED SHEAR TIES IAW 5612148, AND SRM 51-1-21.SDR UPS00833853Finger Doubler · crackedINSPECTION TYPE:C1, STA 1690 - 1890 FINGER DOUBLERS IS CRACKED AT LONG 28R. REMOVED, FABRICATED, AND REPLACED DOUBLERS IAW DWG 5649328, AND SRM 51-1-21.SDR UPS00833820Circuit Breaker · damagedINSPECTION TYPE:A CK EMERGENCY EXIT LIGHTING CIRCUIT BREAKER (5A) DAMAGED. REPLACED C/B B1-115 - REF WDM 33-50-01, PG 1,SH 1, SYS OPS CK NORMAL IAW M/M 33-50-01.SDR UPS00834221Doubler · crackedINSPECTION TYPE:C1, LEFT WING L/E LOWER INTERNAL DOUBLER IS CRACKED AT XFS 335.25. REMOVED, FABRICATED, AND REPLACED DOUBLER IAW DWG 5769589, AND SRM 51-1-20D, 51-1-21.SDR UPS00833849Rib · crackedINSPECTION TYPE:C1, LEFT WING L/E LOWER RIB IS CRACKED AT XFS 310.25. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR RRXA003202Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE UPPER STR SPLICE END BETWEEN STA XRS 408 AND 393, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003201Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT REAR SPAR ATTACH T FITTING AT STA XRS 446, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003200Stringer Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LWR STR CLIP BETWEEN STRINGERS 62 & 63 ON THE LT UPPER WING NR 1 ALT THRU ACCESS HOLE 505A AND THRU MID SPAR ACCESS HOLE 560A AT STA XW 485, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003199Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED CLIP ON THE RT CENTER WING THRU ACCESS 516 AND I/B AT STA XCW -23 BETWEEN STRINGERS 53 & 54, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003210Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT AT STA 447 BETWEEN L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003209Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE ATTACH ANGLE REAR SPAR UPPER CENTER WING IN CABIN Z-21 AT STA 857 +25 TO -45 LWR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003198Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE LT CENTER WING THRU ACCESS HOLE 516 AND THRU MID SPAR ACCESS HOLE 560E O/B BETWEEN STA''S XCW 69.5 TO XCW 46 STR 76, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003835Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO TOP T/E I/B FORMER AT STA. XFS 523, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 53-SDR RRXA003826Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO BOTTOM T/E FORMER AT STA. XFS188.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4, 51SDR RRXA003757Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE L/H LOWER CLIP ON THE L/H CENTER WING THRU ACCESS HOLE 516 THRU MID SPAR ACCESS HOLE 560E BETWEEN STA XCW 46 BETWEEN STR 73 & 74, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM . /////CORRECTIVE ACTION///// SDR RRXA003756Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LWR CLIP L/H CENTER WING THRU ACCESS HOLE 516 THRU MID SPAR ACCESS HOLE 560E AT STA XCW +46 BETWEEN STR 72-73, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREASDR RRXA003755Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON NR 76 LT CENTER WING THRU ACCESS HOLE 516 & THRU MID SPAR ACCESS HOLE 560E O/B BETWEEN XCW 69.5 TO XCW 46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8SDR RRXA003750Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE #76 STRINGER L/H CENTER WING THROUGH ACCESS HOLE 516 AND THROUGH MID SPAR ACCESS HOLE 560E O/B BETWEEN STA XCW 69.5 TO XCW 46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVSDR RRXA001058Floor Panel · crackedMAIN CARGO DECK FLOOR CRACKED AT POSITION NR 7. CUT, FITTED AND INSTALLED NEW FLOOR PANE IAW DC-8 M/M CHAPTER 51-1-21.SDR RRXA003204Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BOTTOM T/E FORMER AT STA XFS 145, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003203Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BOTTOM T/E FORMER AT STA XFS 151.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003843Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO DE-ICER VENT HOLES AT STA. XFS204-310, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4,SDR RRXA003840Frame · tool damageDURING A MAINTENANCE VISIT FOUND DRILL DAMAGE TO LONGERON 20 AT STA. 1580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO 00-257 WITH APPROVED 8110-3 DATED 10/09/00.SDR RRXA003834Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO BOTTOM T/E FORMER AT STA. XFS250-310, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4, 51SDR RRXA003833Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO DE-ICER VENT HOLES AT STA. XFS404-410, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4,SDR RRXA003832Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK IN DE-ICER VENT HOLES AT STA. XFS297-304, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4, 57-2-1SDR RRXA003831Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LOWER FORMER AT STA. XFS466, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D, 51-1-4.SDR RRXA003830Frame · damagedDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO LOWER FRAME AT STA. XFS416, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-4.SDR RRXA003829Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LWR. SKIN OF DE-ICER VENT AT STA. XFS379-385, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51SDR RRXA003828Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED DAMAGE TO SCREW HOLE CORNER OF I/B END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-26, 51-1-4.SDR RRXA003827Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED DAMAGE TO SCREW HOLE LOWER I/B L/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-26, 51-1-21, 51-1-4.SDR RRXA003208Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE AT AFT END OF THE I/B SIDE CANOE FITTING AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003207Access Panel · misdrilledDURING A MAINTENANCE VISIT FOUND A DOUBLE DRILLED HOLE TO THE FUEL TANK PANEL LAND RT WING PANEL 514F, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003206Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER SURFACE LONGERON ON THE LEFT W/W LONGERON 24 AT STA 879-890, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003205Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER DOUBLER AT THE AFT LWR CARGO BILGE AT STA 1340 TO 1360 AND L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003138Splice · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ALONG RADIUS OF THE STRESS PANEL ATTACH POINT END SPLICE AT STA Y=780 AND X=-12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA003742Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ATTACH FITTING ABOVE LONGERON 24R AT STA 902, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PARTS AND INSTALLED IAW DC-8 SRM 51-1-20D ASDR RRXA003050Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE R/H W/W LONGERON VERTICAL FITTING AT STA 940 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARTSDR RRXA003049Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE R/H W/W LONGERON VERTICAL FITTING AT STA 920 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALSDR RRXA003048Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE R/H W/W LONGERON VERTICAL FITTING AT STA 879 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLSDR RRXA003047Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE R/H W/W LONGERON LWR FITTING AT STA 960 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLEDSDR RRXA003046Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" FRAME TO LONGERON FITTING UPPER SIDE AT STA 1168 AND L30L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SDR UPS00833787Light · inoperativeINSPECTION TYPE:N/A, EMERGENCY EXIT LIGHTS INOP. REPLACED BATTERY PACK PER MM 33-50-00, CKS NORMAL.SDR RRXA003758Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE VERTICAL FITTING R/H W/W LONGERON 24R AT STA 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND SDR RRXA003739Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ATTACH FITTING AT STA 902 AND L24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-20D AND DWG 26SDR UPS00833782Actuator · out of adjINSPECTION TYPE:N/A, PILOT REPORT-A/C REQUIRES EXCESSIVE RUDDER TRIM ON TAKEOFF AND LANDING DURING CALM WIND CONDITIONS. IN CRUISE FLIGHT AIRCRAFT REQUIRES 5 DEGREES RUDDER TRIM. ADJUSTED RUDDER POWER PACK IAW MM 27-21-02, SYS OPS CHECKS GOOD.SDR UPS00833785Light · inoperativeINSPECTION TYPE:N/A, FLIGHT DECK EMERGENCY LIGHT INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK IAW DC8 MM 33-5-00 1, OPS CHECKS GOOD.SDR RRXA003312Angle · corrodedDURING A MAINTENANCE VISIT FOUND A DENT TO THE DOOR JAMB FRAME IN C-CARGO COMPT AT STA 1169 AND LBL 14 WATERLINE -58, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-
Back to Douglas DC-8-71F