Douglas DC-8-73

Service difficulty reports · 821

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC873'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DHL200080746CAttach Fitting · crackedAT C-CK; MAIN CARGO COMPARTMENT BEAM ATTACHING FITTING CRACKED (4 INCHES) AT STA 822.00 L-21R. REMOVED CRACKED FITTING IAW SRM 51-1-20D, PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW FITTING IAW SRM 51-1-20D, PG 9. REF: N/R Oct 25, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080748CFitting · crackedAT C CK; MAIN CARGO COMPARTMENT BEAM ATTACHING FITTING CRACKED (3 INCHES) AT STA 702.000 L-21R. REMOVED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 9. REF: N/R 1797.Oct 24, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080744CSkin · dentedAT C-CK; LT ELEVATOR T/E LWR SURFACE 1 INCH DENT STA XE 288,386 (INNER AREA). REMOVED T/E IAW SRM 51-1-21 PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED T/E IAW SRM 51-1-21, PG 1. REF: N/R 0719.Oct 21, 2000 · N807DH · Doug DC873 · Elevator StructureSDR DHL200080753CCargo Track · wornAT C-CK; MAIN CARGO COMPT NR 1 FLOOR TRACK LUGS WORN AT STA 520. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 17 & 19. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW PLUG IAW SRM 53-2-3, PG 17 & 19. REF: N/R 1840.Oct 19, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080742CRib · crackedAT C CK; RT HORIZONTAL STAB L/E INNER RIB CRACKED .5 INCH AT STA XFS 132.500. STOP DRILLED IAW SRM 55-2-3, FIG 4A, CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED REINFORCING ANGLE IAW SRM 55-2-3, FIG 4A. REF: N/R 1389.Oct 18, 2000 · N807DH · Doug DC873 · Horizontal Stabilizer, Spar/RibSDR DHL200080752CFitting · crackedAT C CK; AFT CARGO COMPT LONGERON 31L SPLICE FITTING CRACKED 3 INCHES STA 1040 - 1060. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 21. REF: N/R 1400.Oct 17, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080758CSkin · dentedAT C-CK; LEFT I/B FLAP LWR SURFACE SKIN DENTED AT STA XW 56.5 TO XW 91.0. REMOVED TRAILING EDGE INBOARD FLAP IAW DC-8 OM 27-22, PG 2. REPAIRED FLAP IAW EO 2000545, (EO DHL-010161 & EO 2280), INSTALLED INBOARD T/E FLAP IAW DC-8 OM 27-2-7, PG 7. REF: N/R 1717Oct 16, 2000 · N807DH · Doug DC873 · Trailing Edge FlapsSDR DHL200080757CFitting · crackedAT C CK; REAR PRESSURE BULKHEAD T-FITTING RT CRACKED 8 INCHES (STOP DRILLED). REMOVED SPLICE ANGLE IAW SRM 51-1-20D, PG 9. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED SPLICE ANGLE IAW SRM 51-1-20D, PG 9. REF: N/R 1703.Oct 16, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080745CSeat Track · wornAT C-CK; FLIGHT COMPT LT/RT SEAT TRACKS SHOW WEAR AND ELONGATED HOLES (CAPTAIN). REMOVED DAMAGED SEAT TRACKS, IAW SRM 51-3-0, PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED STRAP, INSTALLED TRACKS AND STRAPS IAW SRM 53-2-3, PG 49-5Oct 15, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080751CAngle · crackedAT C CK; LT WING T/E REINFORCING L ANGLE CRACKED 3 INCHES AT STA 409.000. REMOVED ANGLE IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED ANGLE IAW SRM 51-1-21 PG 1. REF: N/R 1582.Oct 14, 2000 · N807DH · Doug DC873 · Wing Miscellaneous StructureSDR DHL200080741CFrame · crackedAT C-CK; MAIN CARGO COMPT FRAME CRACKED .5 INCH AT STA 1580 L-21R. REMOVED FRAME DAMAGED AREA IAW SRM 53-2-0, PG 5-6, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED SHIM IAW SRM 53-2-0, PG 5-6. REF: N/R 1949.Oct 14, 2000 · N807DH · Doug DC873 · Fuselage Main, FrameSDR DHL200080740CCargo Track · wornAT C-CK; MAIN CARGO COMPT NR 7 FLOOR TRACK LUGS WORN AT STA 160. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 17-19, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED TRACK PLUG IAW SRM 53-2-3, PG 17-19. REF: N/R 1826.Oct 14, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080725CSkin · dentedAT C-CK; NOSE LANDING GEAR AFT DOOR SHOWS IMPROPER PATCH. ALSO BROKEN AND DENTED ON EXTERNAL SKIN LT. REMOVED DAMAGED AREA IAW SRM 52-2-3 FIG 10B, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER AND FILLER IAW SRM 5Oct 14, 2000 · N807DH · Doug DC873 · Landing Gear DoorsSDR DHL200080750CFitting · crackedAT C CK; WING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 5 FITTING CRACKED .5 INCH AT STA 680.000 BL24R. REMOVED CRACKED FITTING IAW SRM 51-1-20D, PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW FITTING IAW SRM 51-1-2Oct 12, 2000 · N807DH · Doug DC873 · Wing Miscellaneous StructureSDR DHL200080739CSkin · dentedAT C-CK; RIGHT I/B FLAP T/E SKIN DENTED AND DEFORMED STA XW 10-XW 96. REMOVED DAMAGED T/E, FABRICATED AND INSTALLED T/E IAW SRM 57-2-1, FIG 2. REF: N/R 0943.Oct 12, 2000 · N807DH · Doug DC873 · Trailing Edge FlapsSDR DHL200080738CSupport Bracket · crackedAT C-CK; RT FLAP FAIRING SUPPORT UPPER PART SHOWS 1 INCH CRACK AT STA 339. PERFORMED STOP DRILL IAW SRM 57-2-0 FIG 2, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 57-2-0, FIG 2. REF: N/R 0169.Oct 12, 2000 · N807DH · Doug DC873 · Trailing Edge FlapsSDR DHL200080737CSkin · deformedAT C-CK; RT WING T/E SKIN INTERNAL FLAP DEFORMED BETWEEN XW 104.000 TO 120.000. REMOVED FLAP T/E SKIN IAW SRM 51-1-21A, PG 4, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED NEW T/E SKIN IAW SRM 51-1-21A, PG 3. REF: N/R 130Oct 12, 2000 · N807DH · Doug DC873 · Trailing Edge FlapsSDR DHL200080733CFitting · crackedAT C-CK; WING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 4 FITTING CRACKED 1 INCH AT STA 680.000 BL -0. REMOVED CRACKED FITTING, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW FITTING IAW SRM 51-1-20D, PG 9. REF: N/R 1611.Oct 12, 2000 · N807DH · Doug DC873 · Wing, Center BoxSDR DHL200080731CFitting · crackedAT C-CK; WING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 5 FITTING CRACKED 1 INCH AT STA 759.000 BL 24R. REMOVED CRACKED FITTING, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW FITTING IAW SRM 51-1-20D, PG 9. REF: N/R 1620.Oct 12, 2000 · N807DH · Doug DC873 · Wing, Center BoxSDR DHL200080730CFitting · crackedAT C-CK; WING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 3 FITTING CRACKED 2 INCHES AT STA 781.500 BL 24L. REMOVED CRACKED FITTING, CLEANED, TREATED AND PRIMED AREA IAW 51-1-8B, PG 1-2, INSTALLED NEW FITTING IAW SRM 51-1-20D, PG 9. REF: N/R 1619.Oct 12, 2000 · N807DH · Doug DC873 · Wing, Center BoxSDR DHL200080703CFitting · crackedWING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 5 FITTING CRACKED 1 INCH AT STA 717.750 BL 24R. REMOVED CRACKED FITTING AT STA 717.750 BL 24R, CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING PER SRM 51-1-20 PAGE 9.Oct 12, 2000 · N807DH · Doug DC873 · Wing, Center BoxSDR DHL200080743CFitting · crackedAT C-CK; WING CENTER SECTION AREA UNDER CABIN FLOOR BELOW TRACK NR 5 FITTING CRACKED 1 INCH AT STA 742.250 BL 24R. REMOVED CRACKED FITTING IAW SRM 51-1-20D, PG 21, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW FITTING IAW SRM 51-1-20Oct 11, 2000 · N807DH · Doug DC873 · Wing, Center BoxSDR DHL200080736CFitting · crackedAT C-CK; VERTICAL STAB INTERNAL FITTING CRACKED 2 INCHES AT STA ZR320.23G. REMOVED CRACKED FITTING IAW SRM 51-1-21, PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-21, PG 1. REF: N/R 0792.Oct 11, 2000 · N807DH · Doug DC873 · Vertical StabilizerSDR DHL200080734CFloor Support · damagedAT C-CK; FLIGHT COMPT AFT AREA INTERIOR-FLOOR SUPPORT ANGLE BROKEN 6 INCHES AT STA 35.000 LBL 47. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0, FIG 1F. REF: N/R 1407.Oct 11, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080732CFloor Support · damagedAT C-CK; FLIGHT COMPT SUB-FLOOR AREA INTERIOR PANEL NR 608 SUPPORT PLATE BROKEN 2 INCHES. REMOVED BROKEN PLATE, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED PLATE IAW SRM 51-1-21A, PG 3. REF: N/R 1412.Oct 11, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080735CFloor Support · damagedAT C-CK; FLIGHT COMPT SUB-FLOOR AREA INTERIOR PANEL NR 609 SUPPORT PLATE BROKEN 4 INCHES. REMOVED BROKEN PLATE IAW SRM 51-1-21A, PG 4, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED PLATE IAW SRM 51-1-21A, PG 3. REF: N/R 1Oct 10, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080701CFloor Support · deterioratedAT C-CK; MAIN CARGO COMPARTMENT-D8 FLOOR LOWER ANGLE DETERIORATED AT STA 1700.000. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1F. REF: N/R 1869.Oct 10, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080727CStructure · crackedAT C-CK; AFT CARGO COMPARTMENT-FWD CARGO DOOR RT LOWER FILLET SHOWS CRACK 1 - .5 INCH. REMOVED DAMAGED FILLET IAW SRM 51-1-21 PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED NEW FILLET IAW SRM 51-1-21, PG 1. REF: N/R Oct 8, 2000 · N807DH · Doug DC873 · Cargo/Baggage DoorsSDR DHL200080726CIntercostal · corrodedAT C-CK; FLIGHT COMPT FWD AREA INTERIOR-INTERCOSTAL ANGLE SHOWS CORROSION AT STA 117 LBL 38. REMOVED CORRODED ANGLE IAW SRM 53-2-0 FIG 3, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED NEW ANGLE IAW SRM 53-2-0, FIG 3. REF:Oct 8, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080729CFloor Panel · crackedAT C-CK; MAIN CARGO COMPT- NR 6F FLOOR PANEL LWR ANGLE 3 INCH CRACK AT STA 1380. PERFORMED STOP DRILL IAW SRM 53-2-0, FIG 1B, CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED REINFORCING ANGLE IAW SRM 53-2-0, FIG 1B. REF: N/R 174Oct 6, 2000 · N807DH · Doug DC873 · Fuselage Floor PanelSDR DHL200080728CFloor Panel · crackedAT C-CK; MAIN CARGO COMPT -NR 6F FLOOR PANEL LWR ANGLE 3 INCH CRACK AT STA 1500. PERFORMED STOP DRILL IAW SRM 53-2-0 FIG 1B, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED REINFORCING ANGLE IAW SRM 53-2-0, FIG 1B. REF: N/ROct 5, 2000 · N807DH · Doug DC873 · Fuselage Floor PanelSDR DHL200080702CFloor Panel · crackedMAIN CARGO COMPARTMENT, 2E FLOOR SKIN SHOWS CRACK 1 INCH AT STA 320.000. STOP DRILLED IAW SRM 53-2-3 PAGE 39/40. FABRICATED DOUBLER IAW SRM 53-2-3 PAGE 39/40. CLEANED TREATED AND PRIMED AREA, INSTALLED DOUBLER PER SRM 53-2-3 PAGE 39/40.Oct 4, 2000 · N807DH · Doug DC873 · Fuselage Floor PanelSDR DHL200080713CCargo Track · wornMAIN CARGO COMPARTMENT NR 4 TRACK LUGS WORN AT STATION 418.000. CUT NR 4 TRACK PLUG, FABRICATED NEW PLUG, CLEANED, PRIMED AND TREATED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080712CCargo Track · wornMAIN CARGO COMPARTMENT NR2 TRACK LUGS WORN AT STATION 418.00. CUT WORN NR 2 PLUG, CONDITIONED TRACK AND FABRICATED NEW PLUG, CLEANED, PRIMED AND TREATED AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080711CCargo Track · wornMAIN CARGO COMPARTMENT NR 5 TRACK LUGS WORN BETWEEN STA 200.00 AND STA 220.00. CUT NR 5 TRACK PLUG, FABRICATED NEW PLUG, CLEANED, PRIMED AND TREATED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080710CCargo Track · wornMAIN CARGO COMPARTMENT NR 4 TRACK LUGS WORN BETWEEN STATION 320.00 AND STATION 340.00. CUT DAMAGED AREA, FABRICATED SPLICE WITH ALCLAD 7075T6 0.100 IAW SRM 53-2-3. FABRICATED TRACK PLUG, CLEANED TREATED AND PRIMED AREA AND INSTALLED NEW SPLICE AND TRACK IAW Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080709CCargo Track · wornMAIN CARGO COMPARTMENT NR 5 TRACK LUGS WORN AT STATION 594.000. CUT NR 5 TRACK PLUG, FABRICATED TRACK PLUG, CLEANED PRIMED AND TREATED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080708CCargo Track · wornMAIN CARGO COMPARTMENT NR 7 TRACK LUGS WORN AT STATION 230.00. CUT OUT DAMAGED AREA, FABRICATED NEW PLUG, CLEANED TREATED AND PRIMED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080707CPlate · brokenFLIGHT COMPT SUB FLOOR AREA INTERIOR PANEL NR 610 SUPPORT PLATE BROKEN 2 INCHES. REMOVED BROKEN PANEL IAW SRM 51-1-21A. FABRICATED PLATE IAW SRM 53-2-0. CLEANED PRIMED AND TREATED AREA IAW SRM 51-1-8B. INSTALLED NEW PLATE IAW SRM 51-1-21A.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage Miscellaneous StructureSDR DHL200080706CCargo Track · wornMAIN CARGO COMPARTMENT NR 7 TRACK LUGS WORN AT STATION 300.00. CUT DAMAGED AREA, FABRICATED NEW PLUG, CLEANED, PRIMED AND TREATED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080704CCargo Track · wornMAIN CARGO COMPARTMENT NR 7 TRACK LUGS WORN AT STATION 270.000. CUT DAMAGED AREA, FABRICATED NEW TRACK, CLEANED TREATED AND PRIMED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 29, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL200080705CCargo Track · wornMAIN CARGO COMPARTMENT FLOOR TRACK NR 1 LUGS WORN AT STA 210 TO 320. CUT OUT DAMAGED AREA, FABRICATED NEW TRACK PLUGS, CLEANED TREATED AND PRIMED AREA AND INSTALLED NEW PLUG IAW SRM 53-2-3.Sep 20, 2000 · N807DH · Doug DC873 · Fuselage, Seat/Cargo Attach FittingsSDR DHL2000807001Filter · dirtyABORTED TAKEOFF, NR 1 ENGINE WOULD NOT ACCELERATE PAST 89 PERCENT N1,TARGET T/O 93.4 PERCENT. DRAINED FUEL FILTERS AND CHECKED PDC LINE, SWITCHED PMC SWITCH ON/OFF. CHECKED T/O POWER ON NR 1 ENGINE OK PER M/M 73-21-10.Jun 8, 2000 · N807DH · Doug DC873 · Aircraft Fuel Filter/StrainerSDR RRXA991479Depressor · bentDURING A MAINTENANCE VISIT, FOUND AFT LOWER MAIN CARGO DOOR SEAL DEPRESSOR BENT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RETURNED TO ORIGINAL CONTOUR AND WELDED IAW COTNEY DRAWING NR J40-R01 WITH APPROVED 8110-Sep 27, 1999 · N105WP · Doug DC873 · Cargo/Baggage DoorsSDR DHL99807005Rt Unit · unservicableRADAR WAS SPOKING, DOES NOT GET GROUND RETURN. REMOVED AND REPLACED RADAR R/T.Jul 8, 1999 · N807DH · Doug DC873 · Weather Radar SystemSDR DHL99801002Duct · looseCOULD NOT MAINTAIN CABIN BELOW 10,000 FT THROUGH FL 280. HEARD LOUD BANG ON CLIMBOUT. FOUND DUCT LOOSE ON RIGHT AND LEFT WATER SEPARTOR. RESECURED PER MM 21-55-3.Jul 5, 1999 · N801DH · Doug DC873 · Cabin Pressure Control SystemSDR DHL99807004Vhf · failedUNABLE TO RECEIVE TRANSMISSIONS ON COMM NR 1 AS REPORTED BY ATC CENTER. RECEIVED TRANSMISSIONS INTERMITTENTLY. LOST VHF NR 2 AFTER 1+ 20 MINUTES OF FLIGHT. RESEATED NR 1 VHF R/T, RESEATED CAPTS FREQ SELECTOR PANEL, OPS CHECKED GOOD. RESEATED NR 2 VHF R/T,Jun 30, 1999 · N807DH · Doug DC873 · VHF Communications SystemSDR DHL99807003Connector · looseHYDRAULIC BRAKE PRESSURE INDICATOR SHOWED 200 PSI DURING FLIGHT. BRAKING WAS NORMAL UPON LANDING. FOUND INDICATOR NOT ATTACHED TO CONNECTOR.Jun 10, 1999 · N807DH · Doug DC873 · Landing Gear Brake SystemSDR RRXA99662Pressurization · malfunctionedUNABLE TO PRESSURIZE AIRCRAFT. AIRCRAFT FERRIED TO BIRMINGHAM FOR DOOR MAINTENANCE.Apr 17, 1999 · N105WP · Doug DC873 · Cabin Pressure Control SystemSDR RRXA991071Spar · misdrilledDURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED, WING, FWD LWR SPAR CAP AT PYLON NR 1, STA XW 467.0, ONE EACH HOLE DOUBLE DRILLED IN SPAR, INTERNAL DOUBLER, AND LOWER WING SKIN IN TEE DOUBLER OUT OF ROUND, PAST 3RD OVERSIZE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRFeb 15, 1999 · N105WP · Doug DC873 · Wing Spar
Back to Douglas DC-8-73