What was found
AT C-CK; FLIGHT COMPT AFT AREA INTERIOR-FLOOR SUPPORT ANGLE BROKEN 6 INCHES AT STA 35.000 LBL 47. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0, FIG 1F. REF: N/R 1407.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CK; FLIGHT COMPT AFT AREA INTERIOR-FLOOR SUPPORT ANGLE BROKEN 6 INCHES AT STA 35.000 LBL 47. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0, FIG 1F. REF: N/R 1407.