SDR RRXA001771Skin · tornDURING A MAINTENANCE VISIT, FOUND A TEAR 8 INCHES AFT OF AILERON LE ON LT OB AILERON UPPER SURFACE OB EDGE SKIN AT STA XA 747, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLEDMar 25, 2000 · N961R · Doug DC873F · AileronsSDR DHL2000804138Structure · crackedRT MLG SHOCK STRUT CENTRAL DOOR STRUCTURE CRACKED. REMOVED DAMAGED DOOR PER SRM 51-1-21. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW DOOR PER SRM 51-1-21.Mar 25, 2000 · N804DH · Doug DC873F · Landing Gear DoorsSDR UPS00832213Bulkhead · corrodedINSPECTION TYPE: C123, RT MLG WHEEL WELL, RT O/B PRESSURE DECK STIFFNER HAS CORROSION AT STA 880. CORROSION BEYOND LIMITS IAW DC8 SRM 53-2-0. FABRICATED & INSTALLED HAT CHANNEL, SPLICE ANGLES & STRAPS IAW REO-G07259, DC8 SRM 51-1-20D & DC8 SRM 51-1-21A.Mar 25, 2000 · N804UP · Doug DC873F · Fuselage Main, BulkheadSDR RRXA002136Frame · misdrilledDURING A MAINTENANCE VISIT FOUND DOUBLE-DRILLED HOLES IN FRAME AT STA 300 AND L2L - L4L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20DMar 24, 2000 · N961R · Doug DC873F · Fuselage Main, FrameSDR RRXA001993Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN FLOORBEAM SUPPORT AT STA 780 TRACK NR 2 MAIN CABIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 51-1-20D.Mar 24, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA001858Support Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN FLOORBEAM SUPPORT TRACK NR 2 MAIN CABIN AT STA 780, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM 51Mar 24, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous StructureSDR UPS00832148Battery Pack · dischargedEMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACK. OPS CK OKMar 24, 2000 · N811UP · Doug DC873F · Emergency LightingSDR RRXA003405Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR BOARD AT STA'S 55 TO 100 AND X60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-7-3 AND DWG 5759394.Mar 23, 2000 · N831AL · Doug DC873F · Fuselage Floor PanelSDR RRXA001942Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT LWR CARGO BILGE STA 1260 TO 1280 AND L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AMar 23, 2000 · N961R · Doug DC873F · Fuselage Main, StructureSDR RRXA001941Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER CARGO COMPT FRAME ATTACH FITTING AT STA 1420 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM Mar 23, 2000 · N961R · Doug DC873F · Fuselage Main, Attach FittingsSDR RRXA001928Skin · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE LEFT I/B FLAP I/B OF STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1 AND 51-1-4.Mar 23, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001807Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT LWR CARGO BILGE AT STA 1260 TO 1280 AND LONGERON L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. CORROSION REMOVAL BEYOND ALLOWABLE LIMIMar 23, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA001806Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER CARGO COMPT FRAME ATTACH FITTING AT STA 1420 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM Mar 23, 2000 · N961R · Doug DC873F · Fuselage Main, Attach FittingsSDR RRXA001793Skin · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE LT I/B FLAP I/B OF STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 57-2-1, 51-1-4 AND 57-2-0.Mar 23, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA002072Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT CENTER L/E UPPER RIB AT STA XFS 497.491, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20DMar 22, 2000 · N961R · Doug DC873F · Wing, Rib/BulkheadSDR RRXA002071Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CENTER L/E UPPER RIB AT STA XFS 461.372, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20DMar 22, 2000 · N961R · Doug DC873F · Wing, Rib/BulkheadSDR RRXA001937Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND A CREASE TO THE LEFT O/B FLAP SCISSOR T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND 57-2-0.Mar 22, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001931Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE UPPER RIB AT LT CENTER L/E AT STA XFS 297.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND 57-Mar 22, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001920Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON 24 SUPPORT FITTING AT STA 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND EO NMar 22, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA001802Skin · crackedDURING A MAINTENANCE VISIT FOUND CREASED AND CRACKED LT O/B FLAP SCISSOR TRAILING EDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SKIN IAW DC-8 SRM 57-2-0 AND 51-1-21.Mar 22, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001796Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED UPPER RIB ON THE LT CENTER L/E AT STA XFS 297.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 57-2-0Mar 22, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001784Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON 24 SUPPORT FITTING AT STA 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. CORROSION REMOVAL BEYOND ALLOWABLE LIMITS, RETURNED TO SEMar 22, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous StructureSDR UPS00832270Skin · crackedINSPECTION TYPE:C1 LEFT WING L/E UPPER SKIN IS CRACKED AT XFS 572.5. REPAIRED IAW SRM 57-2-1 FIG 38.Mar 22, 2000 · N812UP · Doug DC873F · Wing, Plate/SkinSDR RRXA10873Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING AT FS 1230 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D & 53-1-0.Mar 21, 2000 · N602AL · Doug DC873F · Fuselage Main, Attach FittingsSDR RRXA001940Skin · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE SKIN AT LT I/B FLAP O/B OF I/B ROLLER TRACK CUTOUT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 5Mar 21, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001936Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK EXTENDING BEYOND STOP DRILL AT LT WING CENTER L/E LWR RIB AT STA XFS 304.000 PANEL 523, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED RMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001935Rib · misrepairedDURING A MAINTENANCE VISIT FOUND AN IMPROPER REPAIR LT WING CENTER L/E LWR RIB AT STA XFS 310.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 ANDMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001933Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT WING LWR L/E LWR RIB DOUBLER AT STA XFS 297.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-0 AMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001919Baffle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CENTER L/E LWR DE-ICE HOLES BETWEEN STA XFS 322.750 AND 316.500 INSIDE ACCESS PANEL 522A, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND Mar 21, 2000 · N961R · Doug DC873F · Airfoil Anti/De-ice SystemSDR RRXA001805Skin · gougedDURING A MAINTENANCE VISIT FOUND GOUGED SKIN ON THE LEFT I/B FLAP O/B OF I/B ROLLER TRACK CUTOUT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SKIN IAW DC-8 SRM 57-7-1, 51Mar 21, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001801Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK EXTENDING BEYOND STOP DRILL LT WING CENTER LEADING EDGE LOWER RIB AT STA XFS 304.000 PANEL 523, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACKMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001800Rib · misrepairedDURING A MAINTENANCE VISIT FOUND AN IMPROPER REPAIR TO THE LT WING CENTER LEADING EDGE LOWER RIB AT XFS 310.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001798Rib Doubler · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE DOUBLER REPAIR ON THE LT WING LOWER LEADING EDGE LOWER RIB AT STA XFS 297.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001783Baffle · crackedDURING A MAINTENANCE VISIT, FOUND CRACKED DE-ICE HOLES INSIDE ACCESS PANEL 522A AT THE LT WING CENTER LE AT STA XFS 322.750 AND 316.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, APPLMar 21, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA000604Longeron · corrodedDURING A MAINTENACE VISIT, FOUND CORROSION DAMAGE TO LONGERON 34R AT STA 190 TO 310, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR 9754913. (CORROSIOMar 21, 2000 · N831AL · Doug DC873F · Fuselage Main, Longeron/StringerSDR RRXA000603Longeron · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LONGERON AT 35R BETWEEN STA 190 TO 310, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG 9754913. Mar 21, 2000 · N831AL · Doug DC873F · Fuselage Main, Longeron/StringerSDR RRXA002155Door Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN CARGO DOOR LOWER AFT CORNER FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.Mar 20, 2000 · N2674U · Doug DC873F · Fuselage Main, StructureSDR RRXA002154Door Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN CARGO DOOR UPPER AFT CORNER FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.Mar 20, 2000 · N2674U · Doug DC873F · Fuselage Main, StructureSDR RRXA002150Skin · bulgedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE SKIN AT STR 28L AND BS 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8S RM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-1.Mar 20, 2000 · N2674U · Doug DC873F · Fuselage Main, Plate/SkinSDR RRXA002149Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LEFT WHEEL WELL PRESSURE FLOOR AT FS 857-879 AND LBL 58-65, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW XEA-X8-53-874.Mar 20, 2000 · N2674U · Doug DC873F · Fuselage Floor PanelSDR RRXA002104Seat Track · wornDURING A MAINTENANCE VISIT FOUND A WORN NR 6 TRACK AT STA 450-510 AND RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3.Mar 20, 2000 · N961R · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA001925Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RIB AT THE LT LEADING EDGE LWR RIB AT STA XFS 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Mar 20, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001909Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN UPPER WEB LEFT WING O/B LEADING EDGE I/B SECTION AT STA 610.000 ACCESS PANEL 519L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUMar 20, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001900Panel · chafedDURING A MAINTENANCE VISIT FOUND A CHAFED HINGE PANEL ON THE LT O/B FLAP LWR ICE BREAKER AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DC-8 SRM 51-3-0, 51-1-21 AMar 20, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001790Rib · crackedDURING A MAINTENANCE VISIT FOUND A PREVIOUS REPAIR ON RIB CRACKED AT LT LE LWR. RIB AT STA XFS 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. INSTALLED REPAIR DOUBLER IAW DC-8 SRM 57-2-0.Mar 20, 2000 · N961R · Doug DC873F · Leading Edge DevicesSDR RRXA001773Panel · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK IN UPPER WEB LT WING OB LE IB SECTION AT STA 610 ACCESS PANEL 519 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-Mar 20, 2000 · N961R · Doug DC873F · Wing, Plate/SkinSDR RRXA001764Panel · chafedDURING A MAINTENANCE VISIT, FOUND CHAFFED LWR ICE BREAKER HINGE PANEL ON LT OB FLAP AT STA 217, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DC-8 SRM 51-1-7, 51-1-21 ANMar 20, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR UPS00832128Fitting · crackedINSPECTION TYPE: C123, AFT CARGO BAY DOOR RAMP COVER GATE FWD STOP FITTING IS CRACKED. REMOVED & REPLACED STOP FITTING, PN NR 4754061-1 IAW DC8 SRM 51-1-21.Mar 20, 2000 · N804UP · Doug DC873F · Cargo/Baggage DoorsSDR RRXA003737Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM UPPER CHORD AT STA 1300 LT LBL 52 INCHES C-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SMar 19, 2000 · N961R · Doug DC873F · Fuselage Main, Floor BeamSDR RRXA001994Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TRACK SUPPORT FITTING AT STA 700 AND TRACK NR 5 MAIN CABIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 51-1-20D.Mar 19, 2000 · N961R · Doug DC873F · Fuselage Miscellaneous Structure
Back to Douglas DC-8-73F