What was found
DURING A MAINTENACE VISIT, FOUND CORROSION DAMAGE TO LONGERON 34R AT STA 190 TO 310, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR 9754913. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).