SDR RRXA000515Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 31 LEFT SPLICE FITTING BETWEEN STA 440 TO STA 450. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE FITTING IAW DAC SDR RRXA000513Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 340 AND BL 0. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER APPROVED ENGINEERING SKETCH SK 831-97SDR RRXA000512Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 879 AND BL 48 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER APPROVED ENGINEERING SKETCH SKSDR RRXA000511Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LEFT WING LEADING EDGE SKIN AT XFS 854. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1 FIGURE 38. CORROSIOSDR RRXA000510Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 33 RIGHT BETWEEN STA 55 TO STA 70. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW LONGERON SECTION IAW DAC DWG 3642838. SDR DHL2000803132Channel · crackedAT C-CHECK, LEFT WING ACCESS PANEL 505C DOME NUT CHANNEL CRACKED (2) PLACES. REMOVED CRACKED CHANNEL AND FASTENERS IAW SRM 51-1-21A PAGE 4. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8 PAGE 11 & 12. FABRICATED PLATE IAW DC-8 MM 57-33-07 PAGE 201 AND 202 SDR DHL2000803131Channel · crackedAT C-CHECK, DOME NUT CHANNEL CRACKED ON RT PANEL 506B. REMOVED FASTENERS FROM DAMAGED AREA, CLEANED, TREATED AND PRIMED IAW SRM 51-1-8 PAGE 11 & 12. FABRICATED DOUBLER IAW DC8 MM 57-23 07 PAGE 201 & 202 AND APPLICAPILITY OF S/B 57-65 PAGE 1 TO 5. INSTALLED SDR RRXA003393Strap · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE GILLINER SUPPORT STRAP AT STA 1080 X+41 TO X-41 Z-10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21A ASDR RRXA002191Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT WELDS TO THE CUSP PANEL FRAME AT STA 1540 TO 1580 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACKS AND INSTALLED REPAIR IAW EO NR 00-016 WITHSDR RRXA000606Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LEFT WING L/E SKIN AT STA 6.225 X LDI AND XW 408, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED AND INSTALLED IAW DC-8 SRM 51-1-21 AND DAC DWG NRSDR RRXA000517Stiffener · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM STIFFENER AT STA 120 AND BL 46 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW STIFFENER IAW DAC DWG 5755674. CORSDR RRXA000505Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 34 LEFT AT STA 55. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW LONGERON IAW DAC DWG 4615293. CORROSION DAMAGE RECORDESDR RRXA000504Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 34 RIGHT AT STA 55. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW LONGERON IAW DAC DWG 4615293. CORROSION DAMAGE RECORDSDR DHL2000806001Autopilot · failedAUTOPILOT WILL NOT TRACK, ROLLS 30 DEGREE BANK TURNS. DEFERRED PER MEL 22-1.SDR RRXA003798Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO NR 4 PYLON I/B FWD ATTACH ANGLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51-3-0 & 51-1-7 & 51-1-20D.SDR RRXA000528Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM FITTING AT STA 1660 AND BL 63 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-1-0. CORROSSDR DHL200080389CFloorboard · deterioratedAT C-CHECK, FWD LOWER CARGO NR 3 FLOOR DETERIORATED FROM FS 260 TO 280. REMOVED FLOOR PANEL AND FASTENERS IAW SRM 51-3-0 PAGE 1, 2, 3. FABRICATED FLOOR PANEL IAW SRM 53-11-3 PAGE 4C. CLEANED, TREATED AND PRIMED IAW SRM 51-1-21 PAGE 11 & 12. INSTALLED FLOORSDR DHL200080393CFloor Support · crackedAT C-CHECK, FWD LOWER CARGO FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 270 NEAR L-33 LT. REMOVED FLOOR SUPPORT ANGLE AND PERFORMED ANTI-CORROSIVE TREATMENT TO AFFECTED AREA IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 53-2-0 PAGE 2E-2F. TREATED AND PRISDR DHL200080393Floor Support · crackedFWD LOWER CARGO FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 270 NEAR L-33 LT. REMOVED FLOOR SUPPORT ANGLE AND PERFORMED ANTI-CORROSIVE TREATMENT TO AFFECTED AREA IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 53-2-0 PAGE 2E-2F. TREATED AND PRIMED DOUBLER SDR DHL200080389Floorboard · deterioratedFWD LOWER CARGO NR 3 FLOOR DETERIORATED FROM FS 260 TO 280. REMOVED FLOOR PANEL AND FASTENERS IAW SRM 51-3-0 PAGE 1, 2, 3. FABRICATED FLOOR PANEL IAW SRM 53-11-3 PAGE 4C. CLEANED, TREATED AND PRIMED IAW SRM 51-1-21 PAGE 11 & 12. INSTALLED FLOOR PANELS WITHSDR RRXA003792Web · damagedDURING A MAINTENANCE VISIT FOUND BROKEN OUT DAMAGE TO MAIN CARGO DOOR WEB FRAME AT STA. 160, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 & E.O. 00-016 WITH APSDR RRXA000662Rib · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK AT FASTENER ON THE LT O/B LEADING EDGE UPPER RIB AT STA XFS 572.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLERS, STOP DRILLED TO THE CRACKS AND INSTASDR RRXA003391Bracket · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LOWER CLOSER WEB ATTACH ANGLE AT STA 418 ABOVE L21R Z+2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-20, SDR RRXA000642Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE ATTACH FITTING AT STA 1140 AND LONGERON 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR SDR RRXA000509Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 660 AND BL 40 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER ENGINEERING SKETCH SK 831-008. SDR RRXA000503Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 879 AND LONGER 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-0 FIGURE 8. CORROSION DAMAGE SDR RRXA000355Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT BETWEEN STA 1766 -1746 RT AND BETWEEN L28R TO L30R. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLES IAW SRM 51-1-21 AND DER APPROVED EO SDR RRXA000343Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION OF FLOORBEAM AT FS 1620 LONGERON 26L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC-8 SRM 51-1-21 AND DC-8 SRM 51-1-2SDR RRXA000335Longeron · corrodedDURING A MAINTENANCE VISIT FOUND LONGERON L26R CORRODED BETWEEN FS 1717 AND 1734. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAP DOUBLER IAW DER APPROVED EO NR 00-016 AND DAC SRM 51SDR RRXA003795Frame · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FWD LWR CARGO COMPT BILGE AT STA. 80 AND ABOVE 31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SDR RRXA000699Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SUPPORT FITTING BELOW CUSP. AT STA 924 AND RBL 65, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW SUPPORT FITTING AND INSTALLED IAW DC-8 SRM 51-1-20 ANDSDR RRXA000640Frame · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK AT THE LOWER L/E FORMER ANGLE LT HORIZONTAL STAB AT STA XFS 47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG 5SDR RRXA000602Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 980 TO 1000 AND LONGERON 35 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW SRM 51-1-21D AND DAC DWG NR 5SDR RRXA000506Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 1660 AND BL 44 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER APPROVED ENGINEERING SKETCH 83SDR RRXA000502Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BULKHEAD ATTACHMENT FITTING AT STA 8 AND LONGERON 33 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DAC DWG 461SDR RRXA000352Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORRSION AT FLOORBEAM UNDER SIDE ANGLE STA 1240. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SHIMS AND ANGLE IAW DC-8 SRM 51-1-21 AND DER APPROVED EO 0SDR RRXA000351Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION AT FLOORBEAM UNDER SIDE ANGLE STA 1280. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND SHIMS IAW DC-8 SRM 51-1-20A AND DER APPROVED SDR RRXA003789Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO CABIN R-1 THRESHOLD FWD I/B AT STA. 170, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. WELDED CRACK IAW MIL-STD 2219, NDT C/W IAW ASTM E 1417, NO FLAWS NOTED. INSTALSDR RRXA000360Duct · damagedAIRCRAFT HEAT DUCT, RT SIDE STA 260 - 280 HAS HOLE.SDR RRXA000349Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON LONGERON L31L STA 1500, DAMAGE EXCEEDED LIMITATIONS I.A.W DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA I.A.W. DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAP DOUBLER IAW SRM 51-1-21 AND DERSDR RRXA002933Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 1300 AND X-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-2. (CORROSION DAMAGE RECSDR RRXA00349Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON LONGERON L31L STA 1500. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAP DOUBLER IAW SRM 51-1-21 AND DER APPROVED EO 00-016. CORROSION DSDR RRXA000365Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CABIN STA 1180 L21 RT FWD SIDE FITTING CRACKED. REMOVED AND REPLACED FITTING IAW DC-8 SRM 51-3-0 AND 51-1-8.SDR RRXA000359Duct · crackedFOUND AIRCRAFT DUCT AT STA 460 - 480 CRACKED.SDR RRXA000356Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK IN FUSELAGE SKIN AT LONGERON 31 RT (2 INCH CRACK) STA 1690. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FINGER DOUBLER IAW SRM 51-1-8SDR RRXA000354Skin · dentedDURING A MAINTENANCE VISIT FOUND LT AILERON CONTROL TAB HAS DENT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED AERODYNAMIC FILLER AND BLENDED SMOOTH IAW DC-8 SRM 51-1-8 AND DER APPROVESDR RRXA000350Finger Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON FINGER DOUBLER IN LWR CARGO COMPARTMENT STA 1440 TO 1460 LONGERON 31L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FINGER DOUBLER IAW DER SDR RRXA000348Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION IN THE AFT LWR CARGO BILGE AREA CIRC FRAME LONGERON DOUBLER STA 1500 L31 AFT SIDE. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FINGER DOUBLERSDR RRXA000342Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION UNDER NUT PLATE UPER CARGO COMPARTMENT FS 717 XCW 32/5 LT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW DC-8 SRM 51-1-21 & DESDR RRXA000341Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, UPPER CARGO COMPARTMENT FS 725 - 742 XCW 24.5 RT TANK PLATE LID. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21 A
Back to Douglas DC-8-73F