SDR RRXA000339Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON LWR SURFACE OF PRESSURE WEB BELOW COCKPIT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DER APPROVED EO 00--1SDR RRXA000338Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON FLOORBEAM STA 67, 40 INCHES RT OF CENTER FLIGHT COMPARTMENT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR CHANNEL AND SHIMS IAW DER SDR RRXA000337Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION BELOW COCKPIT FLOOR STA -12 L21L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND SPLICE DOUBLER IAW DER APPROVED EO 00-016 ANSDR RRAX000362Skin · lightning strikeDURING A MAINTENANCE VISIT FOUND RIGHT WING TIP UPPER SKIN LIGHTNING STRIKE. BLEND OUT EXCEEDED LIMITS IAW DC-8 SRM. INSTALLED FILLER AND BONDED AREA WITH DEVCON IAW EO 00-016. SANDED AND CONTOURED AREA IAW DC-8 SRM 51-1-19 AND EO 00-016.SDR RRAX000360Duct · damagedAIRCRAFT HEAT DUCT, RT SIDE STA 260 - 280 HAS HOLE.SDR RRXA000639Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO LONGERON 13L AT STA 784, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG 3779970.SDR RRXA003389Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN SEAT TRACK AT STA 55 TO 200 AND RBL-X-63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3, FIGSDR RRXA002966Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SIDEWALL TUNNEL AT STA 1100 AND L24L - L26L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORROSISDR RRXA002963Bracket · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BRACKET BETWEEN STA 1260 - 1280 AND L25R - L26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORSDR RRXA002962Bracket · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BRACKET BETWEEN STA 1240 - 1260 AND L25R - L26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORSDR RRXA000633Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO LONGERON 9R END FITTING AT STA 900, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR 3779659.SDR RRXA000605Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 350 BETWEEN LONGERONS 31L TO 32L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA000601Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN SEAT TRACK AT STA 55 TO 200 AND AT RBL 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-3. (CORROSSDR RRXA000559Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN SEAT TRACK AT STA 400 AND LONGERON RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED SEAT TRACK IAW DC-8 SRM 53-2-3 FIG A8. (CORROSIOSDR RRXA000540Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO MAIN CABIN SEAT TRACK AT FS 739 - FS 990. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE CABIN SEAT TRACK, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED, FABRICATED AND INSTALLED SEAT TRACK FROM STSDR RRXA000345Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION AT STA 480 LONG 27R UNDER SKIN. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED FINGER DOUBLER IAW DER APPROVED EO 00-016. CORROSION DAMAGE RECORDED IN EWA CORSDR RRXA000332Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO HORIZONTAL STABILIZER SKIN OUTBOARD L/E INBOARD AT STA XFS 210.000. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER SDR DHL200080328CPanel · crackedAT C-CHECK, RIGHT WING L/E INTERNAL PART ACCESS PANEL 518A CRACKED .25 INCH AT XFS 720. FABRICATED AND INSTALLED DOUBLER PER SRM 57-2-0.SDR RRXA002968Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT SIDEWALL AT STA 1140 AND L24L-L25L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DAMAGSDR RRXA002960Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24 & X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORRSDR RRXA002947Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 740 - 760 AND X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIONSDR RRXA002943Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONSDR RRXA002942Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DSDR RRXA002941Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RESDR RRXA002940Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RESDR RRXA002939Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRSDR RRXA002938Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 1680 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RESDR RRXA002937Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICE ON THE FLOOR PLANK BETWEEN STA 580 - 720 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRSDR RRXA002936Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB BETWEEN STA 580 - 720 AT AT X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DAMAGSDR RRXA002935Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720 AND AT X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSSDR RRXA002931Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDESDR RRXA002930Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIOSDR RRXA002929Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDED IN ESDR RRXA002928Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DSDR RRXA002927Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DSDR RRXA002926Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DSDR RRXA002925Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONSDR RRXA002923Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORDED IN ESDR RRXA002922Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN SDR RRXA002921Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN SDR RRXA002920Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FLOOR PLANK AT STA 800 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORSDR RRXA000508Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK BETWEEN STA 300 TO 320 AND BL 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION IAW DAC DWG 67SDR RRXA000353Skin · gougedDURING A MAINTENANCE VISIT FOUND LT INBOARD FLAP WEDGE HAS 4 GOUGES. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED EXTERNAL DOUBLERS AND INSTALLED IAW DC-8 SRM 51-1-8 AND 51-1-21 AND DER APPROVED EO 0SDR DHL200080379CSkin · dentedAT C-CHECK, LT ELEVATOR LOWER SKIN SHOWS SEVERAL DENT DAMAGES I/B SECTION AROUND XE 28.843 TO XE 94.5. CUT OUT DAMAGED AREA, FABRICATED REPAIR SKIN SEGMENT, INTERNAL DOUBLER SPLICE, FINGER DOUBLER AND INSTALLED IAW EO NR DHL012501. N/R 3055SDR DHL200080330CElevator · crackedAT C-CHECK, RIGHT ELEVATOR L/E FILLET CRACKED .5 INCH. FABRICATED REPAIR AND INSTALLED PER SRM 51-1-21. N/R 3021SDR DHL200080329CSkin · crackedAT C-CHECK, RIGHT WING L/E INTERNAL PART .25 INCH AT XFS 726. FABRICATED DOUBLER PER SRM 57-2-0. N/R 1230SDR RRXA002946Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-8. (CORROSION DSDR RRXA002945Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DSDR RRXA002944Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSIONSDR RRXA000635Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO A FITTING AT STA 822 AND LBL 24 AND WL -4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND REPLACED IAW SRM 51-1-20D AND DAC DWG NR 3755222 .
Back to Douglas DC-8-73F