Douglas DC-8-73F

Service difficulty reports · 15,471

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC873F'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA000339Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON LWR SURFACE OF PRESSURE WEB BELOW COCKPIT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DER APPROVED EO 00--1Feb 7, 2000 · N792FT · Doug DC873F · Fuselage Main, Plate/SkinSDR RRXA000338Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON FLOORBEAM STA 67, 40 INCHES RT OF CENTER FLIGHT COMPARTMENT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR CHANNEL AND SHIMS IAW DER Feb 7, 2000 · N792FT · Doug DC873F · Fuselage Main, Floor BeamSDR RRXA000337Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION BELOW COCKPIT FLOOR STA -12 L21L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND SPLICE DOUBLER IAW DER APPROVED EO 00-016 ANFeb 7, 2000 · N792FT · Doug DC873F · Fuselage Main, Plate/SkinSDR RRAX000362Skin · lightning strikeDURING A MAINTENANCE VISIT FOUND RIGHT WING TIP UPPER SKIN LIGHTNING STRIKE. BLEND OUT EXCEEDED LIMITS IAW DC-8 SRM. INSTALLED FILLER AND BONDED AREA WITH DEVCON IAW EO 00-016. SANDED AND CONTOURED AREA IAW DC-8 SRM 51-1-19 AND EO 00-016.Feb 7, 2000 · N792FT · Doug DC873F · Wing, Plate/SkinSDR RRAX000360Duct · damagedAIRCRAFT HEAT DUCT, RT SIDE STA 260 - 280 HAS HOLE.Feb 7, 2000 · N792FT · Doug DC873F · Air Distribution SystemSDR RRXA000639Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO LONGERON 13L AT STA 784, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG 3779970.Feb 6, 2000 · N831AL · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA003389Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN SEAT TRACK AT STA 55 TO 200 AND RBL-X-63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3, FIGFeb 5, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002966Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SIDEWALL TUNNEL AT STA 1100 AND L24L - L26L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORROSIFeb 5, 2000 · N792FT · Doug DC873F · Fuselage Main, StructureSDR RRXA002963Bracket · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BRACKET BETWEEN STA 1260 - 1280 AND L25R - L26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORFeb 5, 2000 · N792FT · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA002962Bracket · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BRACKET BETWEEN STA 1240 - 1260 AND L25R - L26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORFeb 5, 2000 · N792FT · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA000633Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO LONGERON 9R END FITTING AT STA 900, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR 3779659.Feb 5, 2000 · N831AL · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA000605Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 350 BETWEEN LONGERONS 31L TO 32L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW PART AND INSTALLED IAW DC-8 SRM 51-1-20D.Feb 5, 2000 · N831AL · Doug DC873F · Fuselage Main, Plate/SkinSDR RRXA000601Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN SEAT TRACK AT STA 55 TO 200 AND AT RBL 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-3. (CORROSFeb 5, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000559Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN SEAT TRACK AT STA 400 AND LONGERON RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED SEAT TRACK IAW DC-8 SRM 53-2-3 FIG A8. (CORROSIOFeb 5, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000540Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO MAIN CABIN SEAT TRACK AT FS 739 - FS 990. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE CABIN SEAT TRACK, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED, FABRICATED AND INSTALLED SEAT TRACK FROM STFeb 5, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000345Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION AT STA 480 LONG 27R UNDER SKIN. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED FINGER DOUBLER IAW DER APPROVED EO 00-016. CORROSION DAMAGE RECORDED IN EWA CORFeb 5, 2000 · N792FT · Doug DC873F · Fuselage Main, Plate/SkinSDR RRXA000332Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO HORIZONTAL STABILIZER SKIN OUTBOARD L/E INBOARD AT STA XFS 210.000. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA DER Feb 5, 2000 · N792FT · Doug DC873F · Horizontal Stabilizer, Plate/SkinSDR DHL200080328CPanel · crackedAT C-CHECK, RIGHT WING L/E INTERNAL PART ACCESS PANEL 518A CRACKED .25 INCH AT XFS 720. FABRICATED AND INSTALLED DOUBLER PER SRM 57-2-0.Feb 4, 2000 · N803DH · Doug DC873F · Wing, Plate/SkinSDR RRXA002968Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT SIDEWALL AT STA 1140 AND L24L-L25L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DAMAGFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA002960Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24 & X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORRFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002947Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 740 - 760 AND X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002943Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002942Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002941Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002940Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002939Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002938Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 1680 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002937Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICE ON THE FLOOR PLANK BETWEEN STA 580 - 720 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002936Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB BETWEEN STA 580 - 720 AT AT X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DAMAGFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Miscellaneous StructureSDR RRXA002935Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720 AND AT X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002931Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDEFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002930Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIOFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002929Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDED IN EFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002928Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002927Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002926Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002925Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002923Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORDED IN EFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002922Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN Feb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002921Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN Feb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002920Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FLOOR PLANK AT STA 800 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORFeb 4, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA000508Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK BETWEEN STA 300 TO 320 AND BL 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION IAW DAC DWG 67Feb 4, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR RRXA000353Skin · gougedDURING A MAINTENANCE VISIT FOUND LT INBOARD FLAP WEDGE HAS 4 GOUGES. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED EXTERNAL DOUBLERS AND INSTALLED IAW DC-8 SRM 51-1-8 AND 51-1-21 AND DER APPROVED EO 0Feb 4, 2000 · N792FT · Doug DC873F · Trailing Edge FlapsSDR DHL200080379CSkin · dentedAT C-CHECK, LT ELEVATOR LOWER SKIN SHOWS SEVERAL DENT DAMAGES I/B SECTION AROUND XE 28.843 TO XE 94.5. CUT OUT DAMAGED AREA, FABRICATED REPAIR SKIN SEGMENT, INTERNAL DOUBLER SPLICE, FINGER DOUBLER AND INSTALLED IAW EO NR DHL012501. N/R 3055Feb 4, 2000 · N803DH · Doug DC873F · Elevator, Plate/SkinSDR DHL200080330CElevator · crackedAT C-CHECK, RIGHT ELEVATOR L/E FILLET CRACKED .5 INCH. FABRICATED REPAIR AND INSTALLED PER SRM 51-1-21. N/R 3021Feb 4, 2000 · N803DH · Doug DC873F · Elevator, Plate/SkinSDR DHL200080329CSkin · crackedAT C-CHECK, RIGHT WING L/E INTERNAL PART .25 INCH AT XFS 726. FABRICATED DOUBLER PER SRM 57-2-0. N/R 1230Feb 4, 2000 · N803DH · Doug DC873F · Wing, Plate/SkinSDR RRXA002946Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-8. (CORROSION DFeb 3, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002945Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DFeb 3, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA002944Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSIONFeb 3, 2000 · N792FT · Doug DC873F · Fuselage Floor PanelSDR RRXA000635Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO A FITTING AT STA 822 AND LBL 24 AND WL -4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND REPLACED IAW SRM 51-1-20D AND DAC DWG NR 3755222 .Feb 3, 2000 · N831AL · Doug DC873F · Fuselage Miscellaneous Structure
Back to Douglas DC-8-73F