Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS98826826Fitting · crackedINSPECTION TYPE:C, FITTING AT STA 1180, LONG 33R IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4758514 AND SRM 51-3-0.SDR UPS98826825Fitting · crackedINSPECTION TYPE:C, FITTING AT STA 1180, LONG 35R IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3758496 AND SRM 51-3-0.SDR UPS98826824Fitting · crackedINSPECTION TYPE:C, FITTING AT STA 1180, LONG 35L IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4758514 AND SRM 51-3-0.SDR RRXA98141Channel · chafingDURING A MAINTENANCE VISIT, FOUND CHAFFING ON UPPER FLANGE CHANNEL ON NR 3 SPOILER RIGHT WING, MATERIAL LOSS WAS THROUGH THE ENTIRE FLANGE THICKNESS. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED SPLICE REPAIR IAW FAA APPROVED DER TIMCO ENGINEERING SKETCHSDR RRXA98139Frame · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FRAME AT STA 70 AT LONGERON 27 RIGHT. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SPLICE REPAIR IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04747.SDR UPS98826804Cargo Track · corrodedINSPECTION TYPE-C, STA 360 TO 440 ABOVE STR 33R, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 52955978 AND SRM 51-3-0.SDR UPS98826803Fitting · corrodedINSPECTION TYPE-C, STA 320 BETWEEN STR 35L TO 36, THE BACK-UP FITTING HAS HEAVY CORROSION. REMOVED AND REPLACED FITTING IAW SRM 53-2-0 FIG 2D.SDR RRXA98140Longeron · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON 3 RIGHT AT STA 12, ALSO CORROSION DAMAGE TO LONGERON 10 RIGHT AT STA 23. REMOVED DAMAGED SECTIONS FROM LONGERONS 3 RIGHT AND 10 RIGHT, TREATED AREAS IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SDR RRXA98145Striker · out of adjustRIGHT MAIN GEAR DOOR WARNING LIGHT ALTERNATE AND RED DOORS NOT LATCHED LIGHT ON WITH GEAR UP CYCLED GEAR NO HELP. ADJ ALTERNATE LIGHT STRIKER PLATE RIGHT SIDE. ADJ ADJUSTABLE LINK TO MAINTAIN MIN OF 0.010 W/GEAR DOWN AND DOORS OPEN BETWEEN LINK OPS CK OK.SDR RRXA98138Frame · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FRAME AT STA 260 BETWEEN LONGERONS 25 LEFT AND 26 LEFT. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SPLICE REPAIR IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REOSDR RRXA98136Floorbeam · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 920 AND RBL 64. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04740.SDR RRXA98135Frame · misdrilledDURING A MAINTENANCE VISIT, FOUND TOOL DAMAGE TO FRAME, INNER FLANGE AT STA 600 AND LONGERON 9 LEFT. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04739.SDR RRXA98134Floorbeam · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 1730 AND LBL 32. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04737.SDR RRXA98133Floorbeam · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBEAM 2 EACH LOCATIONS, STA 1700 AT BL 0 AND LBL 34. REMOVED DAMAGED SECTIONS, TREATED AREAS IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED 2 EACH DOUBLER REPAIRS AT BL 0, AND LBL 34, IAW FAA APPROVED SDR RRXA98132Frame · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FRAME WEB AT STA 1610 AND LONGERON 20 LEFT. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04735.SDR UPS98826808Longeron · corrodedINSPECTION TYPE-C, FS 280 TO 300 LONGERON 29L CORRODED. REPAIRED IAW SRM 53-2-2 AND 53-4-1.SDR UPS98826818Fitting · crackedINSPECTION TYPE-C, FRAME FITTING JUST UNDER LT CUSP CRACKED AT FS 1280. REMOVED AND REPLACED FITTING IAW SRM 51-1-21.SDR UPS98826807Stringer · corrodedINSPECTION TYPE-C, FS 280 TO 300 STR 28L CORRODED BEYOND LIMITS. REPAIRED IAW SRM 53-2-2 AND 53-4-1.SDR UPS98826806Longeron · corrodedINSPECTION TYPE-C, LONGERON 31L AND FINGER DOUBLER HAVE CORROSION BTWN STA 1160 TO 1220. REMOVED CORROSION FROM DOUBLER AND REPAIRED LONGERON 31L IAW 8110- 3 APPROVED DHC SK 874-770.SDR UPS98826802Cargo Track · corrodedINSPECTION TYPE-C, STA 1240 TO 1260 ABOVE STR 33L, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223 AND SRM 51-3-0.SDR UPS98826801Cargo Track · corrodedINSPECTION TYPE-C, STA 1140 ABOVE STR 33R, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223 AND SRM 51-3-0.SDR UPS98826800Cargo Track · corrodedINSPECTION TYPE-C, STA 1140, ABOVE STR 33L, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223.SDR UPS98826796Splice · crackedINSPECTION TYPE-C, FS 1040 TO 1060 STR 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-3-0.SDR UPS98826754Rib · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS397.750, THE LWR L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826753Strap · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS621.000, THE L/E RIB TIE STRAP IS CRACKED. REMOVED, FABRICATED AND REPLACED STRAP IAW DWG 5655441 AND SRM 51-1-21.SDR UPS98826730Rib · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS635.000, THE UPPER L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826728Rib · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS.666.250, THE UPPER L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826725Rib · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS.621.000, THE UPPER L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826724Rib · crackedINSPECTION TYPE:C, RT WING L/E AT STA XFS 616.250, THE LWR L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826723Fitting · crackedINSPECTION TYPE:C, STA 1260-1280, STR 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3754473 AND SRM 51-1-20.SDR RRXA98131Spacer · corrdedDURING MAINTENANCE VISIT, FOUND NR 1 PYLON, T/R SPACER (P/N 305-519-803), WORN AND CORRODED AROUND SHAFT AT ATTACH PONITS. FABRICATED AND INSTALLED NEW T/R SPACER, IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04727.SDR UPS98826820Fitting · crackedINSPECTION TYPE-C, LT WING NR 4 FLAP HINGE ACTUATOR MOUNT FITTING IS CRACKED. REMOVED AND REPLACED CANOE FITTING IAW MM 27-51-00.SDR UPS98826810Intercostal · crackedINSPECTION TYPE-C, INTERCOSTAL LWR ATTACH ANGLE JUST FWD OF FS 1160 ABOVE LONG 35R CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826805Cargo Track · corrodedINSPECTION TYPE-C, STA 470 TO 640 ABOVE STR 33L, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223 AND SRM 51-3-0.SDR UPS98826799Cargo Track · corrodedINSPECTION TYPE-C, STA 70 TO 260 ABOVE STR 33R, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223 AND SRM 51-3-0.SDR UPS98826798Cargo Track · corrodedINSPECTION TYPE-C,STA 70 TO 260 ABOVE STR 33L, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759223 AND SRM 51-3-0.SDR UPS98826755Skin · crackedINSPECTION TYPE:C, LT WING L/E LWR SKIN AT STA XFS598.000 IS CRACKED AT THE DRAIN HOLE AND 1 SCREW. STOP DRILLED CRACKS AND REPAIRED IAW SRM ADD DC8-5320-4087.SDR UPS98826752Fitting · crackedINSPECTION TYPE:C, STA 440-460, STR 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-1-20D.SDR UPS98826751Doubler · crackedINSPECTION TYPE:C, STA 426 AT LONGERON 34L, THE FINGER DOUBLER IS CRACKED. REPAIRED THE AREA IAW 8110-3 APPROVED DHC SK 874-569.SDR UPS98826750Fitting · crackedINSPECTION TYPE:C, STA 1040-1060, STR 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED SPLICE FITTING IAW DWG.3750257 QND SRM 51-3 -0.SDR UPS98826732Longeron · corrodedINSPECTION TYPE:C, LONGERON 29L AND 30L BETWEEN STA 280-340 EACH HAVE HEAVY CORROSION. REPAIRED AREAS IAW SRM 53-2-2 AND SRM 51-1-20D.SDR UPS98826731Rib · crackedINSPECTION TYPE:C, LT WING L/E AT STA XFS397.750, THE LWR L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS98826715Fitting · crackedINSPECTION TYPE:C, MAIN DECK FLOORBEAM SUPPORT FITTING AT STA 1200 AND STR 27R IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 9754024 AND SRM 51-1-20D.SDR RRXA99485Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FINGER DOUBLER WITH TWO SHEARED RIVETS AT STA 1342 BL 30R TO 31R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC8 SRM 53-2SDR RRXA98130Rib · crackedDURING A MAINTENANCE VISIT, FOUND WING, CENTER L/E RIB AT XRS=360.250 HAS 0.5 INCH CRACK.SDR UPS98826829Cargo Track · corrodedINSPECTION TYPE:C, STA 435 ABOVE STR 33L, CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5887623 AND SRM 51-3-0.SDR UPS98826819Fitting · crackedINSPECTION TYPE-C, THE RT WING FLAP HINGE SUPPORT FITTING AT STA XF 409.6673, INBOARD SIDE HAS A CRACK. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826815Clip · crackedINSPECTION TYPE-C, FS 1300 TO 1320 LONG 32R FWD INTERCOSTAL ATTACH CLIP HAS EXTREME CORROSION AND AFT ATTACH CLIP IS CRACKED. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT CLIPS IAW SRM 51-1-21 AND DWG 4758514-11 AND -12.SDR UPS98826811Fitting · corrodedINSPECTION TYPE-C, FS 300 AT STR 33R FRAME FITTING HAS HEAVY CORROSION. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826721Fitting · crackedINSPECTION TYPE:C, LONGERON TO INTERCOSTAL TIE FITTING AT STA 1180 AND LONG 35R IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3758497 AND SRM 51-1-20D.
Back to Douglas DC-8-73F