Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS98826718Bracket · crackedINSPECTION TYPE:C, RT LEADING EDGE BETWEEN NR 3 AND NR 4 ENG OUTBOARD SLOT ATTACH BRACKET TO STUB WING RIB IS CRACKED. REMOVED, FABRICATED AND REPLACED IAW DWG 5769857 AND SRM 51-1-21.SDR UPS98826714Fitting · crackedINSPECTION TYPE:C, STA 440-460 STR 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-3-0.SDR UPS98826713Fitting · crackedINSPECTION TYPE:C, STA 440-460 STR 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-3-0.SDR UPS98826610Fire Loops · malfunctionedAT FL 330 OBSERVED THE MASTER WARNING LIGHT ON. NO OTHER INDICATIONS ABNORMAL. CHECKED SHORT CIRCUT NR 4 DID NOT TEST IN EITHER POSITION THE WARNING LIGHT CAME ON AGAIN, CHOOSE TO SHUT DOWN NR 4. UNABLE TO DETERMINE IF FIRE EXISTS. AFTER SHUT DOWN NR 4 MANSDR UPS98826821Fitting · crackedINSPECTION TYPE-C, RT UPPER CABIN WING BOX AREA AT FS 702.8 RBL 25 FLOORBEAM SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826816Support · corrodedINSPECTION TYPE-C, C PIT FLOOR TRACK SUPPORT HAS CORROSION UNDER NUT PLATES FROM FS 980 TO 1200 LONG 33L. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT TRACK SUPPORT IAW SRM 51-1-21 AND DWG 5751516.SDR UPS98826814Frame · corrodedINSPECTION TYPE-C, FRAME HAS HEAVY CORROSION UNDER NUT PLATE AT FS 1060 LONG 36. REPAIRED IAW DHC SK-802-676.SDR UPS98826712Fitting · crackedINSPECTION TYPE:C, LONGERON SPLICE FITTING BETWEEN STA 1040-1060 LONG 31R IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-3-0.SDR RRXA99465Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LAVATORY AREA UNDER FLOOR AREA AT STA 26 TO 40 X24R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ANGLES IAW DAC DWG 5888479 AND DC8 SRMSDR UPS98826817Fitting · corrodedINSPECTION TYPE-C, RMLG W/W O/B FWD CORNER AT FS 880, FWD LWR SIDE OF FITTING HAS HEAVY CORROSION LONGERON 24. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826722Cargo Track · corrodedINSPECTION TYPE:C, STA 980-1070 AT STR 33R, THE CARGO TRACK HAS HEAVY CORROSION. REMOVED, FABRICATED AND REPLACED TRACK IAW DWG 5759229 AND SRM 51-3-0.SDR UPS98826717Rib · crackedINSPECTION TYPE:C, THE RIGHT OUTBOARD SLOT OUTBOARD UPPER CLOSURE RIB IS CRACKED. REMOVED AND REPLACED CLOSURE RIB IAW DWG 5769857 AND SRM 51-1-20D.SDR UPS98826644Rib · crackedINSPECTION TYPE:C, LT WING L/E RIB CRACKED ON UPPER ARM BY AFT FASTENER STA XFS 585.000, REPAIRED IAW SRM 57-2-0.SDR UPS98826643Clip · crackedINSPECTION TYPE:C, LT WING L/E UPPER RIB ATTACH CLIP CRACKED AT STA XOLDI 6.225. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT CLIP IAW SRM 51-1-20D AND DWG 5769857.SDR UPS98826640Rib · crackedINSPECTION TYPE:C, LT WING L/E RIB UPPER ARM CRACKED BY AFT FASTENER AT STA XFS 622.500, REPAIRED IAW SRM 57-2-0.SDR UPS98826613Splice · crackedINSPECTION TYPE:C SPLICE FITTING FROM F/S 600-620 LONG 31L CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS98826591Skin · damagedINSPECTION TYPE-N/A, SKIN AND RIVETS ERODED JUST AFT OF RADOME AT 12 O'CLOCK POSITION. FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 53-2-1 AND ALODINED PER SRM.SDR UPS98826739Skin · corrodedINSPECTION TYPE:C, LT WING L/E LWR SURFACE HAS HEAVY CORROSION 3 INCHES AFT OF L/E AT STA XFS710.000. REPAIRED AREA IAW SRM ADDENDUM DC8-5720-4087-A.SDR RRXA99462Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO END FITTING ON LONG 1 AT STA 70 TO 80. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-21. (CORROSION DAMAGE RECOSDR RRXA99452Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO PANEL P AT STA 436, X-51, Z-.125. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER, FILLER AND L ANGLE IAW DC8 SRM 53-2-3 FIGSDR UPS98826785Frame · corrodedINSPECTION TYPE-C, FRAME LWR FLANGE AT STA 1600, HAS CORROSION AT LONGERON 34L TO 34R. REPAIRED AREA IAW DWG 2641520 AND SRM 53-2-0 FIG 2.SDR UPS98826720Frame · corrodedINSPECTION TYPE:C, FRAME AT LWR FLANGE AT STA 1580 HAS HEAVY CORROSION BETWEEN LONG 35L - 35R. REPAIRED AREA BY REPLACEMENT AND SPLICING IAW SRM 53-2-0 FIG 2.SDR UPS98826719Frame · crackedINSPECTION TYPE:C, STA 660 AT STR 22R, THE FRAME HAS A 3 INCH CRACK. REMOVED, FABRICATED AND REPLACED FRAME CAP IAW DWG 3646688 AND SRM 51-1-20D.SDR UPS98826642Shear Tie · crackedINSPECTION TYPE:C, F/S 640 BETWEEN STR 26R-27R - SHEAR TIE IS CRACKED. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SHEAR TIE IAW SRM 53-2-0.SDR UPS98826641Shear Tie · crackedINSPECTION TYPE:C, F/S 640 BETWEEN STR 26L-27L - SHEAR TIE HAS 3 CRACK. REMOVED AND REPLACED SHEAR TIE IAW SRM 53-2-0 FIG 2B.SDR RRXA99493Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FORWARD PIT FRAME AT STA 220 BL 34R TO 33R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FRAME SPLICE IAW DC8 SRM 53-2-0 FIG 2, 51-1-20DSDR RRXA99444Floor · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN CENTER WING FLOOR PANEL NR 12 PARTS RACK AT STA 870 TO 1000 X45R LONG 21. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAISDR RRXA99476Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING ON LONGERON 24R AT STA 1684 TO 1690, X-35 TO -36, Z-11 TO -11.5 BL 24R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. DRILLED AND INSTALLED NEW END FITTINSDR RRXA99453Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO PANEL P AT STA 420, X-55 TO -60, Z0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION AND SPLICE PLATES IAW DC8 SRM 53-2-3 FIG 9SDR RRXA99450Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO PANEL I AT STA 510 BL 21R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER, FILLER AND L ANGLE IAW DC8 SRM 53-2-3. (CORROSIOSDR RRXA99449Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO PANEL P AT STA 540 BL 21R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 AND 51-1-21. (CORROSIONSDR RRXA99442Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL NR 2 CENTER WING SECTION AT STA 925 TO 930 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR DHL98807003Engine · failedENG NR 2 ROLLED BACK TO IDLE THEN FAILED AT FL 330. DECENDED AND ATTEMPTED RESTART. RESTART SUCCESSFUL AND NO ABNORMALITIES FOR THE REST OF THE FLIGHT. VISUALLY INSPECTED INLET AND EXHAUST. PERFORMED N1 ROTOR CHECK, ENGINE CHECK, AND SPECIFIC GRAVITY FOR PSDR RRXA99470Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GILLINER ATTACH ANGLE OF RIGHT SIDE OF ACCESSORY COMPARTMENT DOOR HINGE AT STA 1540, X-8 TO -17, Z-7 TO -9. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATSDR RRXA99467Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AT STA 1730 BL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED GUSSET IAW DAC DWG 5755032, DC8 SRM 51-1-21, 51-1-20D, AND 51-1-21SDR RRXA99482Structure · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO TORQUE BOX AT STA 1220 TO 1230 BL 22L TO 23L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).SDR RRXA99473Cusp · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LEFT HAND CUSP LOWER FLANGE AT STA 1180 TO 1200 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SPLICE ANGLE AND DOUBLER IAW DC8 SRSDR RRXA99472Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LEFT SIDE FLOOR SUPPORT NUTPLATES AND SUPPORT AT STA 1760 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW COLLAR AND SUPPORT ANSDR RRXA99471Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BOTTOM OF FLOOR BOARD IN AFT ACCESSORY COMPARTMENT AT STA 1620 BL 21R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FSDR RRXA99469Bracket · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BOTTOM FLOOR SUPPORT BRACKET LEFT SIDE AT STA 1700, X+14, Z0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW BRACKET IAW DAC DWG 57550SDR RRXA99490Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR BOARD IN LEFT HAND TUNNEL AT STA 70 TO 80 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DAC DWG 5892154 AND DSDR RRXA99489Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR BOARD AT STA 330 TO 335 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-0. (CORROSION DAMAGE RECORDSDR RRXA99468Support · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBEAM SUPPORT BRACE AT AFT ACCESSORY COMPARTMENT LEFT SIDE AT STA 1710, X+30, Z-5. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SDR RRXA99454Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AT STA 361BL 9L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DAC DWG 55887371 AND 51-1-20D. (CORROSION DAMAGESDR RRXA99448Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 560 TO 580 BL 17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLES IAW DC8 SRM 53-2-0 AND 51-1-20D. (CORRSDR RRXA99447Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 620 TO 640 BL 17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR INTERCOSTAL IAW DAC DWG 9753291 AND DC8 SRM 51SDR RRXA99410Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON SUPPORT MOUNT FITTING AT STA 1400. REMOVED AND DID NOT REINSTALL IAW BOEING/DOUGLAS DIRECTIVE 367846. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).SDR RRAX98292Fitting · crackedDURING A MAINTENANCE VISIT FOUND INNER FRONT SPAR SPLICE FITTING (PN: 5615090) CRACKED. REMOVED FITTING, FABRICATED AND INSTALLED NEW FITTING BY MATERIAL SUBSTITUTION IAW FAA APPROVED TIMCO DER REO-04751.SDR RRXA99481Support · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO VERTICAL SUPPORT FOR GILL LINER SIDEWALL AROUND BACKSIDE OF NUT PLATE ON LOWER END AT STA 1480 BL 26L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANSDR RRXA99488Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBEAM ATTACH FITTING IN LOWER FWD CARGO PIT AT STA 460 BL 21R TO 22R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW D
Back to Douglas DC-8-73F