Douglas DC-9-31

Service difficulty reports · 7,433

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC931'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR Y2PA20121010049Socket · damagedROW 13 WHITE EMERGENCY LIGHT IN FLOOR LIGHTS FOUND TO BE INOPERATIVE DURING INSPECTION. MX REPLACED THE LAMP HOLDER ASSY (SOCKET) IAW AMM 33-52-01 AT ROW 13. OPS CHECKED GOOD IAW INSTALLATION MANUAL.Oct 10, 2012 · N231US · Doug DC931 · Emergency LightingSDR Y2PA20121010048Socket · damagedLAST RED EMERGENCY LIGHT IN AISLE FLOOR FOUND TO BE INOPERATIVE DURING INSPECTION. MX R & R THE LAST RED EMERGENCY LIGHT LAMP HOLDER ASSEMBLY ON AISLE FLOOR IAW AMM 33-21-27. OPS CHECKED GOOD WITH NO DEFECTS NOTED.Oct 10, 2012 · N231US · Doug DC931 · Emergency LightingSDR Y2PA20121010047Battery Pack · dischargedEMERGENCY LIGHTS FROM EXIT ROW FORWARD FOUND TO BE INOPERATIVE IN FLOOR DURING INSPECTION. REPLACED THE AFT BATTERY PACK I/A/W DC-9 MM 33-52-01. OPS CHECK WAS GOOD IAW LIGHTING SYSTEMS INSTALLATION MANUAL. ACFT RETURNED TO SERVICE.Oct 10, 2012 · N231US · Doug DC931 · Emergency LightingSDR Y2PA20121010046Battery Pack · dischargedEMERGENCY LIGHTS FROM EXIT ROW FORWARD FOUND TO BE INOPERATIVE IN FLOOR DURING INSPECTION. REPLACED FORWARD BATTERY PACK I/A/W DC-9 MM 33-52-01. OPS CHECK WAS GOOD IAW LIGHTING SYSTEMS INSTALLATION MANUAL. ACFT RETURNED TO SERVICE.Oct 10, 2012 · N231US · Doug DC931 · Emergency LightingSDR Y2PA20120523027Pan · corrodedFORWARD LOWER CARGO DOOR LOWER PAN CORRODED. MX REMOVED CORRODED PAN AND PERFORMED SPLICE. REPAIR IAW SRM 53-05, FIG 44 AND EA 96-51-02 R1.May 22, 2012 · N231US · Doug DC931 · Fuselage Miscellaneous StructureSDR Y2PA2011093000026Wire · brokenPASSENGER CABIN EMERGENCY FLOOR ESCAPE PATH LIGHTING FOUND TO BE INOPERATIVE WHILE PERFORMING A SERVICE CHECK. MX FOUND A SHORT IN THE EMERGENCY EXIT FLOOD LIGHT. A WIRE HAD BROKEN AWAY FROM THE LIGHT SOCKET AND GROUNDED. WIRE WAS REPAIRED AND THE SYS OPS CSep 30, 2011 · N231US · Doug DC931 · Light System WiringSDR Y2PA2011011000001Wire · damagedCABIN OVERHEAD EMERGENCY LIGHTS FOUND INOPERATIVE DURING PERFORMANCE OF AN A-CHECK. MX REPLACED BATTERY PACKS WITH SERVICEABLE. AFTER REPLACEMENT OF BATTERY PACKS, MX FOUND LAST ROW OF EMERGENCY LIGHT REMAINED INOPERATIVE. MX FOUND A PINCHED & FRAYED WIRE Jan 8, 2011 · N231US · Doug DC931 · Light System WiringSDR Y2PA2010112900032Battery Pack · dischargedRT AFT NACELLE LIGHT DOES NOT ILLUMINATE WITH EMERGENCY LIGHT SWITCH. FOUND DURING SERVICE CHECK. MX REPLACED THE EMERGENCY POWER SUPPLY IAW MM33-53-00. ACFT RETURNED TO SERVICE.Nov 25, 2010 · N231US · Doug DC931 · Emergency LightingSDR DALA1017379949Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND FUNCTIONALLY CHECKED IT.Jul 23, 2010 · N8928E · Doug DC931 · Emergency LightingSDR DALA1017369949Fuse · blownDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 8-10 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE FUSE IN THE POWER SUPPLY. OPERATIONAL CHECK WAS GOOD.Jul 23, 2010 · N8928E · Doug DC931 · Emergency LightingSDR DALA1015629949Battery Pack · dischargedDURING LINE CHECK MAINTENANCE FOUND EMERGENCY LIGHTS AT ROW 8 THRU 10 INOP. MAINTENANCE REPLACED BATTERY PACK PER IAW AMM 33-53-00. OPERATIONAL CHECK OF LIGHTS NOW CHECK GOOD.Jul 2, 2010 · N8928E · Doug DC931 · Emergency LightingSDR DALA1015249997Battery Pack · dischargedDURING LINE CHECK MAINTENANCE FOUND EMERGENCY LIGHTS AT ROW 18 THRU 21 INOP. MAINTENANCE REPLACED BATTERY PACK PER IAW AMM 33-53-00. OPERATIONAL CHECK OF LIGHTS NOW CHECK GOOD.Jul 1, 2010 · N8933E · Doug DC931 · Emergency LightingSDR DALA1013589936Skin · crackedDURING LINE CHECK FOUND CRACK IN FORWARD ENTRY DOOR INNER SKIN AT FASTENER HOLE. R & R LOWER AFT DOOR INNER SKIN IAW SRM.Jun 17, 2010 · N1799U · Doug DC931 · Passenger/Crew DoorsSDR DALA1013349995Lamp · inoperativeDURING LINE CHECK MX FOUND EMERGENCY LIGHTS IN CAT WALK AFT 2 LAMPS INOP. FOUND LIGHTS ASSY CIRCUIT BAD. R & R AFT AND MIDDLE LIGHT ASSEMBLIES IAW WDM 33-51-03 AND AMM 33-53-00. OPS CHECK OF LIGHTS NOW ALL CHECK GOOD.Jun 12, 2010 · N8978E · Doug DC931 · Emergency LightingSDR DALA1012689935Wire · brokenDURING LINE CHECK, MX FOUND EMERGENCY PATH LIGHT AT ROW 14 INOP. MX DISCOVERED THAT A WIRE WAS BROKEN AT CONNECTOR OF LIGHT. MX REPLACED WIRE HARNESS FROM UNDER SEAT REF AMM 33-53-00. OPS CHECK OF LIGHT NOW CHECKS GOOD. (2010-00439)Jun 8, 2010 · N1332U · Doug DC931 · Light System WiringSDR DALA1012679989Power Supply · inoperativeDURING LINE CHECK, FOUND CAT WALK AND AFT TAIL CONE RELEASE HANDLE EMERGENCY LIGHT INOP. MX REPLACED POWER SUPPLY PACK IAW WD 33-51-01. OPS CHECK OF LIGHTS NOW CHECK GOOD.Jun 6, 2010 · N8945E · Doug DC931 · Emergency LightingSDR DALA1010879989Battery Pack · dischargedON FLIGHT CHECK MX FOUND EMERGENCY LIGHTS IN THE AFT 4 ROWS IN COACH INOP. MX R & R BATTERY PACK FOR EMERGENCY LIGHT. OPS CHECK OF LIGHTS NOW CHECK GOOD.May 21, 2010 · N8945E · Doug DC931 · Emergency LightingSDR DALA101037Power Supply · inoperativeDURING LINE CHECK MX, FOUND L1 DOOR EMERGENCY LIGHT INOP. MX REPLACED L1 DOOR EMERGENCY POWER SUPPLY IAW AMM 33-53-00. OPS CHECK OF LIGHTS WAS GOOD.May 19, 2010 · N8932E · Doug DC931 · Emergency LightingSDR DALA101036Battery Pack · dischargedDURING LINE CHECK MX, FOUND AFT TAIL COMPARTMENT EMERGENCY LIGHTS INOP. MX REPLACED AFT TAIL COMPARTMENT BATTERY PACK IAW WDM 33-51-01. OPERATION OF LIGHTS NOW CHECKS GOOD.May 19, 2010 · N8932E · Doug DC931 · Emergency LightingSDR DALA108749995Fuse · failedDURING MX CHECK FOUND LAST 4 SEAT EMERGENCY TRACK LIGHTS INOP. MX FOUND FUSE BLOWN IN BATTERY PACK. REPLACED FUSE AND OPS CHECK OF LIGHTS IS NOW GOOD IAW AMM 33-51-04.Apr 25, 2010 · N8978E · Doug DC931 · Emergency LightingSDR DALA108769974Battery Pack · malfunctionedDURING MX CHECK FOUND FWD OVERWING EMERGENCY EXIT LIGHTS WERE DIM. BATTERY PACK WAS REPLACED IAW AMDS 33-53-00. OPS CHECK OF LIGHTS IS NOW GOOD.Apr 23, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA108759974Battery Pack · dischargedDURING MAINTENANCE CHECK FOUND FWD OVERWING EMERGENCY EXIT LIGHTS WERE DIM. BATTERY PACK WAS REPLACED PER IAW AMDS 33-53-00. OPERATIONAL CHECK OF LIGHTS IS NOW GOOD.Apr 23, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA108109995Battery Pack · inoperativeDURING LAYOVER CHECK MX FOUND AFT EMERGENCY EXIT SIGN DIDN'T ILLUMINATE DURING LIGHT TEST. MX REPLACED EXIT SIGN BATTERY PACK IAW MM 33-53-00. SIGN NOW LIGHTS UP. OK FOR SERVICE.Apr 16, 2010 · N8978E · Doug DC931 · Emergency LightingSDR DALA106839974Fuse · failedDURING A POWER SURGE, THE F/A REPORTED THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN DID NOT ILLUMINATE AS DID THE COACH CLASS SECTION OF THE CABIN. MX CONFIRMED THAT THE 1ST CLASS EMERGENCY LIGHT WAS INOPERATIVE AND DISCOVERED AMar 30, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA106709935Wire · brokenDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MX FOUND A BROKEN WIRE AND REPAIRED IT. THE SYS RETURNED TO NORMAL OPERATION.Mar 29, 2010 · N1332U · Doug DC931 · Light System WiringSDR DALA106349974Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THE COCKPIT EMERGENCY LIGHTING WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHT RETURNED TO AN OPERATIONAL CONDITION.Mar 26, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA106339974Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE OVERHEAD EMERGENCY ESCAPE LIGHTING IN THE FWD HALF OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Mar 26, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA106329969Battery · dischargedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING AFT THROUGH ROW 9 OF THE CABIN WERE TOO DIM TO PROVIDE ESCAPE GUIDANCE. MX CHARGED THE BATTERIES FOR 3 HOURS AND THE LIGHTS RETURNED TO AN OPS AND BRIGHT CONDITION.Mar 26, 2010 · N9333 · Doug DC931 · Emergency LightingSDR DALA106169936Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 18-21 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Mar 21, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA106159936Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. *SUPPLEMENT DALA106159336Mar 21, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA106159336Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Mar 21, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA105939935Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROW 20 OF THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.Mar 17, 2010 · N1332U · Doug DC931 · Light System WiringSDR DALA105929945Battery · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-8 & 18-21 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE APPROPRIATE BATTERIES IN THE DIFFERENT APPLICABLE LOCATIONS. OPERATIONAL CHECK WAS GOOD.Mar 17, 2010 · N8925E · Doug DC931 · Emergency LightingSDR DALA105589995Wire · damagedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX FOUND A BAD SPLICE IN THE POWER SUPPLY WIRE AND REPAIRED IT. THEY ALSO REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONMar 15, 2010 · N8978E · Doug DC931 · Light System WiringSDR DALA105519996Web · crackedDURING LINE CHECK FOUND CRACK IN TAIL COMPARTMENT WEB STRUCTURE AT BS 1038 L11. REPAIRED IAW SRM 51-30-2.Mar 11, 2010 · N8932E · Doug DC931 · Fuselage Miscellaneous StructureSDR DALA103869995Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Feb 19, 2010 · N8978E · Doug DC931 · Emergency LightingSDR DALA10386995Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPS CONDITION.Feb 19, 2010 · N8978E · Doug DC931 · Emergency LightingSDR DALA103719936Power Supply · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYS.Feb 14, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA103519974Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EXTERIOR EMERGENCY LIGHT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHT RETURNED TO AN OPERATIONAL CONDITION.Feb 11, 2010 · N9338 · Doug DC931 · Emergency LightingSDR DALA102449945Battery Pack · weakDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-7 AND THE RT OVERWING EMERGENCY EXIT SIGN WERE WEAK. MX REPLACED THE BATTERIES AND THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPS CHECK.Feb 1, 2010 · N8925E · Doug DC931 · Emergency LightingSDR DALA101719936Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Jan 26, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA100969996Connector · disconnectedDURING LINE CHECK, MX FOUND THAT THE RT AFT RED EMERGENCY PATHWAY LIGHTING WAS INOPERATIVE. MX FOUND A CONNECTOR IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYS.Jan 25, 2010 · N8932E · Doug DC931 · Light System WiringSDR DALA100349936Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE RT FWD OVERWING EMERGENCY EXIT SIGN WAS INOPERATIVE. MX REPLACED THE BATTERIES. OPS CHECK WAS GOOD.Jan 13, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA100269936Power Supply · inoperativeDURING LINE CHECK, MX FOUND THAT ALL OF THE EMERGENCY PATHWAY LIGHTS FOR THE CATWALK IN THE TAIL COMPARTMENT WERE INOPERATIVE. MX REPLACED THE EMERGENCY LIGHTS POWER SUPPLY AND OPS CHECKED THE SYS.Jan 9, 2010 · N1799U · Doug DC931 · Emergency LightingSDR DALA100239935Doubler · crackedDURING LINE CHECK FOUND FUSELAGE CRACK AT DOUBLER ABOVE LT PYLON T/E. REPAIRED IAW SRM 53-01-04.Jan 9, 2010 · N1332U · Doug DC931 · Fuselage Main, Plate/SkinSDR DALA100189933Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-7 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERIES IN THE POWER PACK. OPS CHECK WAS GOOD.Jan 5, 2010 · N1334U · Doug DC931 · Emergency LightingSDR DALA100179933Sign · inoperativeDURING LINE CHECK, MX FOUND THAT THE RT OVERWING EMERGENCY EXIT SIGN WAS INOPERATIVE. MX REPLACED THE BATTERIES. OPS CHECK WAS GOOD.Jan 5, 2010 · N1334U · Doug DC931 · Emergency LightingSDR DALA100059988Wire · looseDURING LINE CHECK FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 7-10 OF THE CABIN WERE INOPERATIVE. MX FOUND A LOOSE WIRE IN THE CONNECTOR, REPAIRED THE CONNECTOR PIN AND THE SYS RETURNED TO NORMAL OPERATION.Jan 2, 2010 · N8944E · Doug DC931 · Light System WiringSDR NWAA094569944Power Supply · inoperativeDURING LINE CHECK MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 18-21 OF THE CABIN AND THE CAT WALK LOCATION WERE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.Dec 29, 2009 · N1309T · Doug DC931 · Emergency LightingSDR NWAA094359957Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 11-13 AND 18-21 OF THE CABIN WERE TOO DIM TO PROVIDE ESCAPE GUIDANCE IF OBSCURED BY SMOKE OR DARKNESS. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIDec 16, 2009 · N915RW · Doug DC931 · Emergency Lighting
Back to Douglas DC-9-31