Douglas DC-9-31
Service difficulty reports · 7,433
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC931' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC931' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWAA9911903Bulkhead · crackedDURING OP 16 MAINT CHECK, THE RT BULKHEAD WAS CRACKED 3 INCHES LONG, LOCATED 1 INCH ABOVE FLOOR AND 5 INCHES FROM SIDEWALL ON FWD SIDE, STA 965. REMOVED AND REPLACED BULKHEAD PER SPM 6-70-01.SDR TWAA9911902Bulkhead Angle · crackedDURING OP 16 MAINT CHECK, FOUND AFT PRESS BULKHEAD, FWD SIDE DIAGONAL BRACE ATTACH ANGLE ON PRESSURE BULKHEAD, STA 996 AT UPPER END, CRACKED BETWEEN LONGERON 3L AND 4L. REMOVED CRACKED ANGLE AND FABRICATED NEW ANGLE. PAINTED AND REINSTALLED IN ACCORDANCE WITSDR ABXA9900686Frame · crackedDURING C-CHECK, FOUND OUTBOARD END OF THE AFT PRESSURE BULKHEAD FRAME CRACKED AT LONGERON 15 LEFT. REPAIRED IAW DC9 SRM 51-30-5 AND 51-20-0.SDR 9903359973Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND AFT LOWER CEILING AND TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK B5-28 AT POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR TWAA9911905Longeron · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION IN CABIN AT LONGERON 18R, APPROX STA 946 ON WEB. REPLACED WEB PER SPM 6-70-01, ITEM 4 B-1.SDR TWAA9911904Longeron · corrodedDURING OP 16 MAINT CHECK, FOUND IN CABIN THERE WAS CORROSION ON LONGERON 18 WEB, STA 938R. REPLACED WEB PER SRM 6-70-01, ITEM 4 B-1.SDR GTIA9901086Slide · deployedL-1 DOOR SLIDE PACK FELL TO GROUND AND DEPLOYED. REPLACED L-1 DOOR SLIDE PACK IAW DC-9 MM 25-61-00. (M)SDR ABXA9900650Actuator · corrodedDURING C-CHECK, FOUND LEFT OUTBOARD SPOILER ACTUATOR VALVE BODY EXFOLIATED AND VALVE LINK MOUNT AREA CRACKED. REPLACED ACTUATOR IAW ABX EA 2760D019-001.SDR ABXA9900649Web · crackedDURING C-CHECK, FOUND CUSP WEB CRACKED FORWARD AND AFT OF FRAME AT STATION 598 RIGHT SIDE. REPLACED CUSP WEB IAW DC9 SRM 51-30-2 AND 51-30-1.SDR ABXA9900648Doubler · corrodedDURING C-CHECK, FOUND DOUBLER FORWARD AND AFT OF STATION 718 CORRODED. REPLACED DOUBLER IAW DC9 SRM 51-30-5.SDR USAADD99114Battery · dischargedIND - THE MAIN ENTRANCE DOOR SLIDE ACTIVATED EMERGENCY LIGHT WAS DIM. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY. (M)SDR GTIA9901081Battery Pack · dischargedMYR - FLT 619 - LEFT NACELLE EMERGENCY LIGHT WILL NOT ILLUMINATE. TRANSFERRED TO DEFERRED MAINTENANCE ITEM NR 320. REMOVED AND REPLACED LEFT EMERGENCY NACELLE BATTERY PACK IAW MM CHAPTER 33-53-0. OPERATION CHECKS GOOD. (M)SDR ABXA9900647Longeron · corrodedDURING C-CHECK, FOUND LONGERON 14 LEFT CORRODED AT STATION 1089. REPLACED LONGERON SECTION IAW DC9 SRM 51-30-2.SDR ABXA9900644Web · crackedDURING C-CHECK, FOUND CUSP WEB CRACKED FORWARD AND AFT OF FRAME AT STATION 598, LEFT SIDE. REPLACED CUSP WEB IAW DC9 SRM 51-30-1 AND 51-30-2.SDR USAAD99115Controller · failedPIT - ITH - FLT 1572 - AFTER TAKEOFF, THE AIRCRAFT WOULD NOT PRESSURIZE. THE AIRCRAFT RETURNED TO THE FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE PRESSURIZATION CONTROLLER. (M)SDR USAAD99113Power Supply · inoperativeIND - ONE SECTION OF THE CEILING EMERGENCY LIGHT WERE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY AND POWER SUPPLY. (M)SDR USAAD99112Battery · dischargedIND - THE MAIN ENTRANCE DOOR SLIDE ACTIVATED EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY. (M)SDR ABXA9900643Panel · corrodedDURING C-CHECK, FOUND CORROSION ON LEFT LOWER SLANT PANEL CAP. REPAIRED IAW ABX REA D953-32811MR.SDR 9904709957Frame · crackedDURING L CHECK AND WITH COMPLIANCE WITH SB DC9-53-280 REV 1. A CRACK WAS NOTED ON THE FUSELAGE SKIN AFT OF THE FORWARD PASSENGER DOOR AT DOORSTOP NR 6. REPAIRED PER EA 99-167024.SDR USAAD99111Ac Buss Control · failedPHL-ROC - FLT 275 - DURING CLIMB-OUT, THE CREW NOTICED NUMEROUS 'CLICKS' INDICATING RELAYS CYCLING. IMMEDIATELY THEREAFTER THE ANNUNCIATOR PANEL INDICATED NUMEROUS SYSTEM FAILURES FOLLOWED SHORTLY BY CABIN PRESSURE WARNING. THE AIRCRAFT RETURNED TO THE FIELDSDR TWAA9911211Support · corrodedDURING OP 16 MAINT CHECK, FOUND CENTER FLOOR SUPPORT BEAM AT STA 148 TO 218, WAS CORRODED. REPLACED PART PER SRM 6-70-01.SDR GTIA9901071Battery Pack · dischargedAFT FLIGHT ATTENDANT FORWARD JUMPSEAT LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT B5-27. FOUND POWER AND GROUND WIRE NOT HOOKED TO AFT EXIT LIGHTS, REINSTALLED. FOUND BAD CONNECTION ON AFT OVERHEAD AISLE LIGHTS, REPAIRED SAME LIGHTS. OPERATION SDR GTIA9901070Bulbs · misinstalledMYR - TWO EACH EMERGENCY LIGHTS INOPERATIVE AT OVERHEAD SERVICE ENTRANCE. FOUND INCORRECT BULBS INSTALLED. REPLACED WITH CORRECT ML43 BULBS. OPERATION CHECKED GOOD. (M)SDR GTIA9901069Connector · failedMYR - EMERGENCY FLOOR TRACK LIGHTING BETWEEN ROW 5 AND 15 INTERMITTENT. FOUND BAD CONNECTION AT ROW 15. REPAIRED AS NEEDED. OPERATION CHECKED GOOD. (M)SDR GTIA9901061Battery Pack · dischargedROWS 1 AND 2 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK B5-40 IAW 33-53-0. OPERATIONAL CHECKS GOOD. (M)SDR USAAD99110Actuator · failedROC-DCA - FLIGHT 887 - DURING LANDING GEAR EXTENSION, ON APPROACH, THE NOSE GEAR DID NOT EXTEND. THE LANDING GEAR WAS CYCLED BUT THE NOSE GEAR REMAINED RETRACTED. THE EMERGENCY GEAR EXTENSION LEVER WAS USED AND THE NOSE GEAR EXTENDED. THE AIRCRAFT LANDED WISDR 9903089979Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPAIRED SPLICE IN WIRING HARNESS TO POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR USAAD99109Battery · dischargedTHE CEILING EMERGENCY LIGHTS FOR ROWS 10-13 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES FOR THE ROW 10-13 CEILING EMERGENCY LIGHTS. (M)SDR USAAD99108Supply · failedTHE CEILING EMERGENCY LIGHTS FOR ROWS 1-3 ILLUMINATE WHEN ALL POWER IS TURNED OFF. MAINTENANCE REPLACED THE FORWARD CABIN EMERGENCY LIGHT POWER SUPPLY. (M)SDR TWAA9911205Longeron · crackedDURING OP 16 MAINT CHECK, FOUND LONGERON CRACKED AT UPPER TIE POINT, STA 965, LONGERON 16R. REPAIRED PER SRM 53-02, FIG 18 PAGE 52, DRAWING 5911427.SDR TWAA9911204Support · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR PANEL SUPPORT AT STA 180, BL 0 TO RBL 45 IN. REPLACED PART PER SPM 6-70-01.SDR GTIA9901091Light · inoperativeDTW - AFT OVERHEAD EMERGENCY LIGHT ASSEMBLY BROKEN. REPLACED BULB AND SOCKET TO AFT OVERHEAD EMERGENCY LIGHT ASSEMBLY. SYSTEM CHECKED GOOD ALL IAW DC9 MM SECTION 33-00-00. (M)SDR 9903049979Power Supply · inopDURING LINE MAINTENANCE INSPECTION, FOUND TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR TWAA9911110Jamb · crackedDURING OP 16 MAINT CHECK IN THE FWD CARGO DOOR OPENING, FOUND A CRACK IN SUBSURFACE OF FUSELAGE AT LOWER AFT DOOR JAM AREA. INSTALLED A TWO PIECE DOUBLER. CRACK CONTAINMENT AS PER SRM 53-05, FIG 105, SHEET 1,2,3 AND 4, VIEW 7011C, DRAWING NUMBER 5910142, SHESDR GTIA9901067Light · inoperableAFT CABIN DOOR EMERGENCY LIGHT (HAND HELD) INOPERATIVE. REMOVED AND REPLACED AFT CABIN DOOR EMERGENCY LIGHT ASSY IAW DC-9 MM 33-50-00. (X)SDR GTIA9901059Battery Pack · dischargedFORWARD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK B5-40 IAW MM CHAPTER 33-53-0. OPERATION CHECKS GOOD. (M)SDR GTIA9901033Battery Pack · dischargedMYR - FORWARD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT B5-40 IAW MM CHAPTER 33-53-0, OPERATIONAL CHECK GOOD. (X)SDR ABXA9900627Battery · depletedEMERGENCY LIGHTS WERE INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERIES.SDR TWAA9911109Angle · crackedDURING OP 16 MAINT CHECK AT STA 980, BETWEEN LONGERON 28L AND 27L, INTERCOSTAL ATTACH ANGLE WAS CRACKED. REPLACED CRACKED ANGLE WITH ANGLE OF SAME MATERIAL AS EXISTING, 7075-T6, PER SPM 6-70-01. REPLACED HI-LOCKS PER SRM 51-30-5, PAGE 12.SDR TWAA9911108Former · crackedDURING OP 16 MAINT CHECK, FOUND CRACK IN FORMER .5 INCHES IN LENGTH AT STA 965, LT FWD SIDE, AT JUNCTION OF LOWER LEG OF ENG MOUNT. INSTALLED CHORD ANGLE PART NR 9912243-9, AS PART OF MO 72J14 PHASE G, PER SPM 6-70-01.SDR TWAA9911107Angle · crackedDURING OP 16 MAINT CHECK, FOUND IN LT SIDE OF CABIN AT STA 965 FORMER TO LONGERON 17L HAD ATTACH ANGLE CRACKED. REPLACED ANGLE PART NR 2916078-501, PER SPM 6-70-01.SDR TWAA9911106Web · crackedDURING OP 16 MAINTENANCE, AFT PASSENGER DOOR WAS CRACKED AT PAN, FWD SIDE OF DOOR, ABOVE UPPER LATCH FITTING. REMOVED AND REPLACED WEB PER SRM 6-70-01, PAGE 2, ITEM 4A AND DRAWING NR 9915565.SDR TWAA9911105Angle · crackedDURING OP 16 MAINTENANCE CHECK, AFT CARGO AREA STATION 945, BETWEEN LEFT LONGERON NR 29 AND NR 30, FRAME ANGLE SPLICE WAS CRACKED AT A RIVET. REPLACED ANGLE WITH NEW PART PER SPM 6-70-01.SDR GTIA9901031Wire · looseISP - FLT 113 - EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE ROWS 5 TO 16. FOUND TRACK AT ROW 16 OFF AND WIRES PULLED FROM LIGHTS. RESET WIRES AND TRACKS BACK IN PLACE. OPERATIONAL CHECK GOOD. (X)SDR 9903079997Batteries · dischargedFORWARD CABIN EMERGENCY FLOOR LIGHTING INTERMITTENT. REPLACED BATTERIES IN PACK FOR ESCAPE PATH LIGHTING AT ROWS 1 THRU 4, OPERATIONAL CHECK NORMAL.SDR TWAA9911104Web · crackedDURING OP 16 MAINTENANCE CHECK, FOUND RT MLG WHEEL WELL CRACKED AT AFT INBD CORNER OF RT MLG WHEEL WELL, 30 INCHES FROM CABIN FLOOR. STOP DRILLED CRACK AND REPAIRED PER SRM 53-01 PAGE 10. INSTALLED FASTENERS PER SPM 6-30-07.SDR 9903069997Wire · damagedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD SERVICE DOOR AND FORWARD CABIN SEAT EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE FOUND WIRES BETWEEN ROWS 1 AND 2 PINCHED IN SEAT TRACK SHORTING OUT. REPAIRED WIRING AND REPLACED BATTERY POWER SUPPLY, OPERATIONASDR USAAD99106Battery · dischargedIND - THE FORWARD CABIN OVERHEAD EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE FORWARD CABIN OVERHEAD EMERGENCY LIGHT BATTERIES. (M)SDR TWAA9910911Frame · crackedDURING OP 16 MAINT CHECK, FOUND CRACK IN RADIUS OF FRAME 9911505-6 APPROXIMATELY .75 INCH IN LENGTH, FWD OF RT CENTER WINDSHIELD POST, STA 83.5 AT X=-10. REPAIRED FRAME PER SRM 53-05, FIG 34.SDR TWAA9910910Frame · crackedDURING OP 16 MAINT CHECK, FOUND CRACK IN FRAME NUMBER 9911505-5 ALONG RIVETS APPROXIMATELY 1.25 INCHES IN LENGTH, FWD OF LT CENTER WINDSHIELD POST, STA 83.5 AT X=+10. REPAIRED FRAME PER SRM 53-03, FIG 34.
Back to Douglas DC-9-31