Douglas DC-9-32
Service difficulty reports · 12,755
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA98428Splice · damagedCENTER WING TANK SPLICE FOR STRINGER NR 14 HAS TOOLING MARKS. MTC REMOVED DAMAGED PART FABRICATED AND INSTALLED REPLACEMENT PART USING APPROVED DATA.SDR CALA9800662Beam · crackedINSPECTION FOUND A 4 CRACK IN R-1 DOOR INTERIOR FORWARD NR 2 BEAM. THE CRACK WAS STOP DRILLED IAW SRM 52-05, FIGURE 25. A J-ANGLE, FITTING, AND SHIMS WERE FABRICATED AND INSTALLED IAW SRM 52-05, FIGURE 25 AND 51-10-3.SDR ABXA9800355Window · lack of lubeUNABLE TO OPEN CAPTAIN'S CLEARVIEW WINDOW (EMERG EXIT). WINDOW OPENED AFTER SEVERAL ATTEMPTS. WHEN RECLOSED, WINDOW WOULD NOT REOPEN. LUBRICATED TRACK AND ROLLERS, WINDOW OPS CHECKED GOOD.SDR 9806639919Fuse · blownDURING LINE CHECK, FOUND ESCAPE PATH LIGHTING AT SEAT ROWS 8 THRU 10 INOPERATIVE. MAINTENANCE REPLACED FUSE, OPERATIONAL CHECK NORMAL.SDR 9806589602Control Panel · inoperativeDURING CLIMBOUT, THE WEATHER RADAR WOULD NOT MAP IN ANY POSITION. FLIGHT RETURNED TO MEM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE RADAR CONTROL PANEL, OPERATIONAL CHECK NORMAL.SDR TWAA9807319Bulkhead Casting · crackedMCI - DURING OP 16 MAINTENANCE CHECK, FOUND CABIN FOOT CASTING AFT INBOARD SIDE OF 965 BULKHEAD, CRACKED. REMOVED AND REPLACED CASTING PER SRM 51-01 AND STANDARD PRACTICES. (M)SDR TWAA9807312Block · crackedMCI - DURING OP 16 MAINTENANCE CHECK, FOUND RT WING TE FLAP INSIDE FLAP OUTBOARD FLAP HINGE TO FORWARD MOUNT BOLT, RT AND LT SIDE MOUNT WEBS CRACKED OUT FROM BOLT HOLES. REPLACED MOUNT BLOCK PER STANDARD PRACTICES AND SRM 51-01. (M)SDR MWEA98406Splice · damagedCENTER WING TANK STRINGER 11 SPLICE HAS SEVERAL LOCATIONS OF DAMAGE. FABRICATED REPLACEMENT REPAIR SPLICE USING APPROVED DATA.SDR MWEA98405Splice · corrodedCENTER WING TANK STRINGER 14 SPLICE WAS FOUND CORRODED. REMOVED OLD PART FABRICATED AND INSTALLED REPLACEMENT PART USING APPROVED DATA.SDR MWEA98404Splice · corrodedCENTER WING TANK STRINGER SPLICE ON STRINGER 15 WAS FOUND CORRODED. REMOVED OLD PART FABRICATED AND INSTALLED REPLACEMENT PART USING APPROVED DATA.SDR MWEA98403Splice · corrodedSTRINGER 13 SPLICE IN CENTER WING TANK HAS CORROSION. REMOVED OLD PART FABRICATED AND INSTALLED REPLACEMENT PART USING APPROVED DATA.SDR MWEA98402Splice · damagedCENTER WING TANK STRINGER SPLICE NUMBER 13 HAS PREVIOUS BLEND OUT REPAIR THAT IS BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT SPLICE.SDR MWEA98401Clip · crackedLEFT WING FUEL TANK STRINGER 22 LEFT HAS A CRACKED CLIP AT XRS111. REMOVED OLD CLIP FABRICATED AND INSTALLED REPLACEMENT CLIP.SDR MWEA98400Clip · crackedLEFT WING FUEL TANK STRINGER 22 LEFT HAS A CRACKED CLIP A STATION XRS 111. REMOVED OLD CLIP FABRICATED AND INSTALLED REPLACEMENT CLIP.SDR MWEA98399Frame · corrodedCORROSION AND EXCESSIVE DRILL MARKS WERE FOUND ON FRAME AT FUSELAGE STATION 937. REMOVED CORROSION AND DAMAGED AREA FABRICATED AND INSTALLED REPAIR PARTS USING APPROVED DATA.SDR MWEA98398Rib · corrosionCORROSION WAS FOUND ALONG THE UPPER SURFACE OF THE LOWER CUP OF THE RIB AT WING STATION XRS 164 LEFT SIDE. CLEANED CORROSION AND INSTALLED STRAP REPAIR USING APPROVED DATA.SDR 9806489917Power Supply · inoperativeDURING LINE CHECK, FOUND CATWALK EMERGENCY EXIT LIGHTING INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR 9806469986Light · inoperativeDURING LINE CHECK, FOUND ONE EMERGENCY LIGHT OUT AT TAIL CONE WALKWAY. MAINTENANCE REPLACED THE LIGHT ASSEMBLY MOUNT, OPERATIONAL CHECK NORMAL.SDR VJ9800172Skin · dentedDENT FUSELAGE AT LONG FS 522 2.50 BY 6 BY .0110. REPAIRED IAW EO 98-845, CUT OUT SKIN AT STA 522 L 29R 8.8 BY 5, FABRICATED DOUBLER REPAIR FROM 7075 T6 .063, DIMENSIONS 16.5 BY 10 AND FINGER DOUBLERS FROM 7075 T6 .025 DIMENSIONS 17.875 BY 8 BY 5 IAW EO 98-845SDR VJ9800117Skin · damagedDENT 2.5 X 6 X .0110 IN FUSELAGE AT FS 522, L29R. CUT OUT SKIN, FABRICATED DOUBLER, TREATED AND PRIMED DOUBLER REPAIR AND FINGER DOUBLERS FROM 7075T6 .025 MATERIAL IAW DC9 SRM 51-30-2, 51-30-5 AND EO 98-845.SDR VJ9800116Retract Mech · malfunctionedUPON RETRACTION OF LANDING GEAR AFTER TAKEOFF, EXPERIENCED AIRFRAME VIBRATION. AS PRECAUTIONARY MEASURE FLIGHT CREW ELECTED TO RETURN TO IAD. ON ARRIVAL AT GATE FOUND RT NOSE GEAR DOOR OPEN. INSPECTED NOSE WHEEL AREA AND FOUND NO DAMAGE. CLOSED AND SECUREDSDR GTIA9800047Battery Pack · dischargedCOCKPIT EMERGENCY LIGHT (BOTH BULBS) WILL NOT TEST WHEN CABIN EMERGENCY LIGHT SWITCH PULLED IN ON POSITION. RESET BATTERY PACKS OPERATIONAL GOOD AIW MM 33-50. (M)SDR MWEA98397Slide Cover · fell offTHE GALLEY SLIDE COVER FELL OFF. MTC REINSTALLED GALLEY SLIDE COVER.SDR ABXA9800327Latch · bentCOCKPIT DOOR WAS STUCK CLOSED. WOULD NOT OPEN. FOUND LATCH TO BE BINDING. REPAIRED AND REASSEMBLED HANDLE.SDR 9806369610Battery · dischargedDURING LINE CHECK, FOUND AFT EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR VJ9800132Bulkhead · crackedCRACK FOUND EMANATING APPROX .25 INCH BOTH SIDES OF FASTENER HOLE CANTED BULKHEAD AT FS 1074, L3. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW AEROCORP RES-1 04577 AND DC9 SRM 51-10-04, 51-10-03 AND MM 53-10-0, FIG 811.SDR 9806209614Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND CATWALK EMERGENCY PATH LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL.SDR 9806199921Prox Sensor · failedNOSE LANDING GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR RETRACTION. CREW VERIFIED VISUALLY THROUGH PEEP HOLE THAT GEAR WAS DOWN AND LOCKED. FLIGHT WAS RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED NOSE GEAR PROXIMITY SENSOR. OPERATIONAL CSDR VJ9800115Slide Cover · looseFORWARD ENTRY DOOR SLIDE COVER DISLODGED. RESEATED SLIDE IAW MM 25-60, PERFORMED REQUIRED INSPECTIONS.SDR TWAA9807306Horiz Stab · gougedMCI - DURING OP16 MAINTENANCE CHECK, FOUND ON LT HORIZ STAB TOP AFT 2 BARREL NUT HOLES GOUGED. REAMED HOLES AND INSTALLED BUSHING AND REDRILLED .562 IN PER ARA 15267. (M)SDR TWAA9805301Pump · failedSTL - FLT 599 - DURING CRUISE, THE LEFT HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED. THE SYSTEM PRESSURE FLUCTUATED BETWEEN 1800 - 2800 PSI REGARDLESS OF PUMP SELECTION, HI-LOW-OFF. REPLACED THE LEFT ENGINE DRIVEN HYDRAULIC PUMP MFG PN 314195. OP-15 11-15-97 MSDR 9806229942Battery · dischargedFLIGHT ATTENDANT REPORTED FORWARD FLASHLIGHT INDICATOR NOT FLASHING. REPLACED BATTERY. OPERATIONAL CHECK NORMAL.SDR 9806169924Line · leakingRIGHT HYDRAULIC SYSTEM QUANTITY AND PRESSURE DROPPED TO ZERO EN ROUTE. CREW DECLARED AN EMERGENCY AND CONTINUED TO DESTINATION. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND FLEX LINE LEAKING AT ELECTRIC PUMP OUTLET. REPLACED LINE, OPERATIONAL CHECK SDR 9806159619Connector · brokenDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD PASSENGER DOOR EMERGENCY EXIT SIGN INOPERATIVE. CONNECTOR AT LIGHT ASSEMBLY WAS FOUND TO BE DISCONNECTED. REPAIRED AND REASSEMBLED CONNECTOR, OPERATIONAL CHECK NORMAL.SDR 9806129986Actuator · bindingLOSS OF CABIN PRESSURIZATION OCCURRED DURING CRUISE FLIGHT AND COULD NOT BE CONTROLLED MANUALLY. CREW ACCOMPLISHED EMERGENCY DESCENT TO 10,000 FEET AND CONTINUED TO DESTINATION. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND OUTFLOW VALVE ACTUATOR BINDSDR 9806119609Prox Sensor · brokenDURING APPROACH, NOSE LANDING GEAR GREEN DOWNLOCK LIGHT DID NOT ILLUMINATE AFTER GEAR EXTENSION. EMERGENCY GEAR EXTENSION PROCEDURES WERE UTILIZED AND AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND NOSE GEAR PROXIMITY SENSOR BROKEN AT OVERCENTER LINK. SDR 9805969922Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR 9806099950Smoke Detector · activatedFORWARD LAVATORY SMOKE DETECTOR ACTIVATED ON APPROACH. FLIGHT CREW DECLARED AN EMERGENCY AND AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED WIRING AND ELECTRICAL SYSTEMS. ALL SYSTEMS CHECKED NORMAL. DISCREPANCY COULD NOT BE DUPLICATED.SDR VJ9800338Strap · corrodedCARGO TIE DOWN RING RETAINER STRAPS AFT PIT STA 908 AND 935 CORRODED BEYOND LIMITS IAW DC-9 SRM 53-01 FIG 1. REMOVED AND REPLACED STRAPS IAW MM 25-52-1.SDR VJ9800326Longeron · corrodedLEVEL 2 CORROSION BULGE STA 598 LONG 29RT. REMOVED AND REPLACED LONG 29 RT STA 579-578 IAW 51-30-1, 51-30-2, AND 51-10-3.SDR VJ9800325Doubler · corrodedCORROSION BULGE STA 598 LONG 30-29 RT. REMOVED, FABRICATED AND INSTALLED INNER DOUBLER STA 579-598 LONG 29 RT TO 29 LT IAW SRM 53-31-0 FIG 8, 51-30-1, 51-30-2 AND 51-10-3.SDR VJ9800324Seat Track · corrodedSEAT TRACK STA 201-237 BL 45 RT CORRODED BEYOND LIMITS. REMOVED SECTION OF TRACK AND REPLACED IAW SRM 53-05 FIG 10G.SDR VJ9800138Water Heater · corrodedTOP OF FRESH WATER TANK UNDER FORWARD LAV SINK CORRODED. REPLACED TANK IAW DC9 MM 38-11-4. LEAK AND OPS CHECKED GOOD IAW DC9 MM 38-11-4.SDR GTIA9800042Battery Pack · dischargedFOUND EMERGENCY LIGHT OVER OBSERVERS SEAT INOP. REMOVED AND REPLACED BATTERY PACK IAW MM 33-50, OPERATIONAL CHECK GOOD. (M)SDR 9805939925Battery Pack · dischargedAFT EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR TWAA9809305Fitting · corrodedMCI - DURING OP 16 MAINTENANCE CHECK, FOUND CORROSION ON NR 1 PYLON FRONT SPAR LOWER BEAVER TAIL FITTING. REMOVED CORROSION ON BEAVER TAIL FITTING PER SRM 54-04, FIG 13. ROTOPEENED REWORKED AREA PER SRM 5-04, FIG 13 AND PLATED PER SRM 54-04, PAGE 53, ITEM 4.SDR TWAA9806914Bulkhead Angle · crackedDURING OP 15 MAINTENANCE CHECK, FOUND FUSELAGE TO BULKHEAD ATTACH ANGLE CRACKED BETWEEN LONG 15L AND 16L. REPLACED ANGLE PER SRM 51-01, PAGE 1 ITEM C, AND TWA STD PRACTICE. (M)SDR TWAA9806913Rib · wornMCI - DURING OP 15 MAINTENANCE CHECK, FOUND HOLE WORN THROUGH FLAP RIBS AT RT WING INBOARD AND OUTBOARD FLEX JOINT BOTTOM SIDE. REPLACED END RIBS PER SRM 51-01 AND TWA STD PRACTICE. (M)SDR VJ980319Skin · corrodedIN AFT CARGO COMPARTMENT FOUND CORROSION ON SKIN PANEL ADJACENT TO STR 28L I/B SIDE AT STA 944. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS, MORE THAN 50 PERCENT MAT LOSS IAW SRM 53-01 FIG 1. FABBED DOUBLER, INSTALLED DOUBLER IAW SRM 53-04 FIG 38 (MAT 20SDR MWEA98386Slide Cover · fell offTHE PASSENGER ENTRANCE DOOR SLIDE COVER CAME OFF WHEN OPENED. MTC REINSTALLED PASSENGER DOOR SLIDE COVER.
Back to Douglas DC-9-32