Douglas DC-9-32

Service difficulty reports · 12,755

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC932'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR L1GA200000188Floorboard · crackedCORNER OF FLOOR PANEL CRACKED APPROX 1.5 INCH AT FS 579 TO 613 BL 24R TO 44R. INSTALLED REPAIR DOUBLER.Aug 1, 2000 · N33506 · Doug DC932 · Fuselage Floor PanelSDR L1GA200000187Web · crackedCRACKS 1 EA 3 INCH, 1 EA 4 INCHES, 1 EA 3.5 INCHES AT CUSP WEB LONGERON 18 RT FS 698 TO FS 617. REMOVED AND REPLACED CUSP WEB.Aug 1, 2000 · N33506 · Doug DC932 · Fuselage Miscellaneous StructureSDR L1GA200000186Frame · gougedA .375 X 1 INCH AREA GOUGED AT FS 756 AT LONGERON 18/FRAME. BLENDED GOUGE WITHIN LIMITS.Aug 1, 2000 · N33506 · Doug DC932 · Fuselage Main, FrameSDR L1GA200000185Rod End · corrodedROD END CORRODED 2 INCH SECTION ON LT MLG FLYING DOOR. REMOVED AND REPLACED ROD END.Aug 1, 2000 · N33506 · Doug DC932 · Landing Gear Door Retract SectionSDR L1GA200000184Web · crackedA 1 INCH CRACK FS 207 AT LONGERON 15 LEFT. INSTALLED DOUBLER REPAIR.Aug 1, 2000 · N33506 · Doug DC932 · Fuselage Miscellaneous StructureSDR L1GA200000183Attach Angle · crackedRIGHT HAND PYLON AFT BULKHEAD ATTACH ANGLE O/B END CRACKED. FABRICATED NEW REPAIR, TREATED AND PRIMED AND INSTALLED REPAIR.Aug 1, 2000 · N33506 · Doug DC932 · Nacelle/Pylon StructureSDR L1GA200000182Bracket · corrodedCORRODED BRACKET 1 X 1 INCH, 6 INCH DIAMETER SKIN. REMOVED AND REPLACED BRACKET AND REMOVED CORROSION FROM SKIN, REMOVAL WITHIN LIMITS.Aug 1, 2000 · N33506 · Doug DC932 · Fuselage Miscellaneous StructureSDR CA000830010Tire · blown(CAN) AIRCRAFT REJECTED TAKEOFF DUE TO LT ENGINE POWER LOSS (125-130 KNOTS). NR 2 MAIN TIRE BLOWN, TIRE SEPARATION, DEBRIS OF TIRE FLEW INTO LT ENGINE CAUSING DAMAGE, THE DEBRIS ALSO DAMAGED THE LT INBOARD FLAP. REPLACED ALL FOUR MAIN TIRE AND FOUR MAIN BRAKESJul 31, 2000 · Doug DC932 · TireSDR TWAA0012107Longeron · crackedFOUND A .5 INCH CRACK ON THE I/B FLANGE OF LONGERON 2R, STA 680. SPLICED LONGERON PER SRM 53-02, FIG 18. CHECK-C 7-20-99 STL.Jul 31, 2000 · N929L · Doug DC932 · Fuselage Main, Longeron/StringerSDR TWAA0012106Longeron · crackedFOUND A .5 INCH CRACK IN I/B AND O/B FLANGE OF LONGERON 2R AT STA 756. SPLICED NEW LONGERON SECTION PER SRM 53-02, FIG 18. CHECK-C 7-20-99 STL.Jul 31, 2000 · N929L · Doug DC932 · Fuselage Main, Longeron/StringerSDR AT0000411Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND RIGHT WINDOW BELT AT BS 237 - 313 TO HAVE LIGHTNING STRIKES BEYOND LIMITS. REMOVED AND REPLACED WINDOW BELT PANEL.Jul 28, 2000 · N845AT · Doug DC932 · Fuselage Main, Plate/SkinSDR AT0000419Floor Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT AT BS 160 - 200 CORRODED. REMOVED CORROSION (FOUND OUT OF LIMITS), REPLACED FLOOR SUPPORT IAW DC9 SRM 51-10-04 AND 51-30-05.Jul 27, 2000 · N845AT · Doug DC932 · Fuselage Miscellaneous StructureSDR AT0000410Floor Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT AT BS 200 LBL 44-0 CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW DC9 SRM 51-10-03, 51-10-02, 51-30-05, 53-01 FIG 1 AND 53-11-1 FIG 13.Jul 27, 2000 · N845AT · Doug DC932 · Fuselage Miscellaneous StructureSDR ABXA000396Frame · crackedFUSELAGE FRAME CRACKED BETWEEN FASTENERS ON FORWARD FLANGE AT STATION 598 BELOW LONGERON 11 LEFT. REPAIRED CRACK IAW ABX REA D953-38087MR.Jul 27, 2000 · N986AX · Doug DC932 · Fuselage Main, FrameSDR ABXA000395Structure · crackedFORWARD LOWER CARGO DOOR WAS CRACKED IN 2 PLACES AT NR 2 STOP. REPLACED FORWARD LOWER CARGO DOOR.Jul 27, 2000 · N986AX · Doug DC932 · Cargo/Baggage DoorsSDR AT0000364Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 200 RBL 0 - 22 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOORBEAM IAW DC9 SRM 51-10-04, 51-10-03, 53-11-01, AND 51-30.Jul 27, 2000 · N845AT · Doug DC932 · Fuselage Main, Floor BeamSDR AT0000363Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 200 RBL 22 - 44 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-04, 51-10-03, 53-11-01, AND 51-30-05.Jul 27, 2000 · N845AT · Doug DC932 · Fuselage Main, Floor BeamSDR L1GA200000180Sealant · missingFLT 19 RETURNED TO FIELD AFTER LOUD OUTSIDE NOISE WAS NOTICED DURING T/O. RESEALED GAP IN WINDSHIELD AT SPLICE FRAME AND RETORQUED SCREWS. RETURNED TO SERVICE.Jul 27, 2000 · N33506 · Doug DC932 · Flight Compartment WindowsSDR 0002799606Battery · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD SECTION OF OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.Jul 26, 2000 · N606NW · Doug DC932 · Emergency LightingSDR L1GA200000181Altimeter · stuckON FLIGHT 4, CAPT ALTIMETER STUCK AT 100 FT AND BOTH MODE C NOT ENCODING. R2 CAPT ADC, RETURNED TO SERVICE.Jul 26, 2000 · N14534 · Doug DC932 · Altimeter, Barometric/EncoderSDR AT0000418Seat Track · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND RIGHT INBOARD SEAT TRACK BS 200 - 220. REMOVED AND REPLACED SEAT TRACK IAW TIMCO SERVICE ORDER 151072-43279.Jul 25, 2000 · N845AT · Doug DC932 · Fuselage, Seat/Cargo Attach FittingsSDR AT0000413Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND HORIZONTAL STABILIZER CENTER BOX, AFT SECTION UPPER PANEL TO HAVE EXFOLIATION CORROSION. REMOVED AND REPLACED CENTER BOX AFT SECTION UPPER PANEL IAW TIMCO SERVICE ORDER 151072-42730.Jul 25, 2000 · N845AT · Doug DC932 · Horizontal Stabilizer, Plate/SkinSDR AT0000361Shutoff Valve · crackedRIGHT HYDRAULIC SYSTEM FAILED AND DURING TAXI, HYDRAULIC FUMES ENTERED THE CABIN. ALL PASSENGERS WERE EVACUATED VIA FORWARD STAIRS. FOUND RUDDER HYDRAULIC SHUTOFF VALVE CRACKED.Jul 25, 2000 · N835AT · Doug DC932 · Hydraulic System, MainSDR AT0000417Shear Tie · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK ON SHEAR TIE AT BS 980 LONGERON 29R. REMOVED AND REPLACED SHEAR TIE IAW SERVICE ORDER 151072-43225.Jul 24, 2000 · N845AT · Doug DC932 · Fuselage Main, StructureSDR ABXA000394Fitting · crackedENTRY DOOR HAS CRACKED BEAM END FITTING ABOVE BAYONET. REPLACED FITTING IAW DC9 SRM 51-30-1.Jul 24, 2000 · N986AX · Doug DC932 · Passenger/Crew DoorsSDR ABXA000393Intercostal · crackedINTERCOSTAL CRACKED INSIDE ENTRY DOOR FORWARD OF HANDLE. REPLACED INTERCOSTAL IAW DC9 SRM 51-30-2.Jul 24, 2000 · N986AX · Doug DC932 · Passenger/Crew DoorsSDR ABXA000392Pan · crackedENTRY DOOR INNER PAN TO SIDE STRUCTURE ATTACH FRAME CRACKED. REPAIRED IAW ABX REA D952-38104.Jul 24, 2000 · N986AX · Doug DC932 · Passenger/Crew DoorsSDR ABXA000391Structure · delaminatedLEFT FLYING DOOR (FORWARD HALF) HAD AREA OF DELAMINATION. REPLACED OUTBOARD LEFT MAIN LANDING GEAR DOOR.Jul 24, 2000 · N986AX · Doug DC932 · Landing Gear DoorsSDR MWEA00594Slide · detachedEWR - FLT 279 - FORWARD ENTRANCE DOOR ESCAPE SLIDE HOLDER WAS DETACHED AT BOTTOM. REINSTALLED RETAINING PIN IN CLIP. (M)Jul 23, 2000 · N212ME · Doug DC932 · Escape SlideSDR AT0000421Pan · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEFT AFT LAV VANITY FLOOR PAN CRACKED AND CORRODED. REMOVED DAMAGED AREA AND INSTALLED REPAIR IAW OHM 25-42-50.Jul 23, 2000 · N845AT · Doug DC932 · Fuselage Miscellaneous StructureSDR GTIA000263Slide · dislodgedUPON ARRIVAL OF A/C, FLIGHT ATTENDANT OPENED FORWARD L-1 DOOR AND ESCAPE SLIDE FELL TO GROUND. INSPECTED SLIDE PACK, NOTIFIED M/C AND INSPECTION. RE-INSTALLED SLIDE PACK ON L-1 DOOR IAW CH 25. (M)Jul 22, 2000 · N941ML · Doug DC932 · Escape SlideSDR L1GA200000179Pushrod · dirty921 GEAR UNSAFE LIGHT ON DEPARTURE FLT 1 DAT-LAX. RETURNED TO FIELD. GEAR DAMAGE INCURRED, REQ FERRY TO AAR OK CITY, R2 DOORS AND BYPASS VALVE AS PRECAUTION RET TO SERVICE.Jul 21, 2000 · N27509 · Doug DC932 · Landing Gear Retraction/Extension SystemSDR MWEA00588Flashlight · inoperativeMKE - FLT 107 - PORTABLE EMERGENCY FLASHLIGHT NEAR MAIN CABIN DOOR ILLUMINATES VERY DIM. REPLACED FLASHLIGHT WITH A SERVICEABLE UNIT. (M)Jul 20, 2000 · N301ME · Doug DC932 · Emergency EquipmentSDR AT0000415Pan · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FORWARD CARGO COMPARTMENT LOWER PAN CORRODED BEYOND LIMITS. REMOVED AND REPLACED LOWER PAN IAW TIMCO SERVICE ORDER 151072-43061.Jul 20, 2000 · N845AT · Doug DC932 · Fuselage Miscellaneous StructureSDR AT0000414Light · inoperativeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERIES AND POWER SUPPLY IAW DCP MM 33-50-0.Jul 20, 2000 · N845AT · Doug DC932 · Emergency LightingSDR AT0000409Floor Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT CORRODED BEYOND LIMITS AT BS 960 - 980 LONGERON 18R. REMOVED CORRODED SECTION AND SPLICED NEW EXTRUSION IAW DC9 SRM 53-01 FIG 1, 51-10-02, 51-10-03, AND 51-30-05.Jul 20, 2000 · N845AT · Doug DC932 · Fuselage Miscellaneous StructureSDR AT0000407Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 980 RBL 22 - 50 CORRODED BEYOND LIMITS. FABRICATED REPAIR ANGLE AND FILLER IAW DC9 SRM 53-05 FIG 204, 51-10-04, 51-10-03, 51-30-05, AND 51-30-02.Jul 20, 2000 · N845AT · Doug DC932 · Fuselage Main, Floor BeamSDR AT0000406Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON UPPER CAP OF FLOORBEAM AT BS 996 BL 36R - 46R. REMOVED AND REPLACED UPPER CAP ON FLOORBEAM IAW DC9 SRM 51-10-04, 51-30-01, 51-30-02, AND 51-30-08.Jul 20, 2000 · N845AT · Doug DC932 · Fuselage Main, Floor BeamSDR MWEA00569Skin · corrodedRUDDER HAS LIGHT CORROSION ON INSIDE SURFACE OF SKIN. FABRICATED AND INSTALLED REPAIR DOUBLER.Jul 20, 2000 · N502ME · Doug DC932 · Rudder, Plate/SkinSDR MWEA00570Channel · corrodedFLOOR PANEL SUPPORT CHANNEL CORRODED ON TOP FLANGE AT STATION 160 TO STATION 200. FABRICATED AND INSTALLED FLOOR PANEL SUPPORT CHANNEL.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Miscellaneous StructureSDR MWEA00571Channel · corrodedFLOOR PANEL SUPPORT CHANNEL CORRODDED ON TOP FLANGE LOCATED AT STATION 160. REMOVED AND REPLACED SUPPORT CHANNEL.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Miscellaneous StructureSDR MWEA00572Threshold · chafedCHAFE MARK ON FORWARD ACCESSORY DOOR SILL. FABRICATED AND INSTALLED ANGLE REPAIR.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Miscellaneous StructureSDR MWEA00573Shear Tie · deterioratedFLOORBOARD C-8 HAS DETERIORATED EDGE DISTANCE BY SCREW HOLE LOCATED AT STATION 742. MAINTENANCE REPAIRED EDGE DISTANCE WITH FIBERGLASS REPAIR.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Main, StructureSDR MWEA00555Floorboard · damagedFLOORBOARD D-1 HAS EDGE LIP DAMAGE LOCATED AT STATION 237. FABRICATED AND INSTALLED DOUBLER.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Floor PanelSDR MWEA00560Longeron · crackedLONGERON 3, RIGHT HAND SIDE, HAS A CRACK AT STATION 756. FABRICATED AND INSTALLED LONGERON REPAIR.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Main, Longeron/StringerSDR MWEA00582Attach Angle · crackedSECONDARY ATTACH ANGLES CRACKED AT STATION 83 LEFT AND RIGHT SIDE. FABRICATED AND INSTALLED DOUBLERS AND FILLERS.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Main, Attach FittingsSDR MWEA00583Intercostal · crackedFLOORBOARD INTERCOSTAL CRACKED AT STATION 351, LEFT OF CENTER FLOORBOARD SUPPORT ANGLE. FABRICATED AND INSTALLED INTERCOSTAL REPAIR.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Miscellaneous StructureSDR MWEA00584Floorboard · gougedFLOORBOARD C-8 TOP SURFACE EDGE-LIP HAS 3 AREAS WITH GOUGE/MISDRILL DAMAGE AT STATION 746. REINFORCED FIBERGLASS REPAIR INSTALLED.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Floor PanelSDR MWEA00585Floorboard · puncturedFLOORBOARD C-3 HAS SURFACE PUNCTURE/IMPACT DAMAGE AT STATION 400 AND 410. REINFORCED FIBERGLASS REPAIR INSTALLED.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Floor PanelSDR MWEA00586Floorboard · chafedFLOORBOARD D-6 HAS SURFACE CHAFE DAMAGE AT STATION 737. REINFORCED FIBERGLASS REPAIR INSTALLED.Jul 20, 2000 · N502ME · Doug DC932 · Fuselage Floor Panel
Back to Douglas DC-9-32