Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0480109Frame · corrodedOKC - DURING HV6-CHECK, FOUND E/E COMPARTMENT FRAME CORRODED AT FS 200. REMOVED DAMAGED SECTION. INSTALLED SHIM, PLATE, AND ANGLE PER SRM 53-03. (M)SDR ASAA0480108Vane · chafedOKC - DURING HVC CHECK, FOUND LEFT WING OUTBOARD FLAP VANE INBOARD CAM AND VANE LEADING EDGE ARE CHAFED. REMOVED DAMAGED SECTION. INSTALLED FILLER AND DOUBLER PER SRM 51-70-2 AND 57-03. (M)SDR GTIA040203Floorboard · delaminatedFTW - FOUND MAIN CABIN F/B FS 256-312 CENTER IS DAMAGED AND DELAMINATED AT INSERTS. FABRICATED NEW FLOORBOARD. (M)SDR AALA20040270Battery · dischargedSEA - OVERHEAD EMERGENCY EXIT LIGHT IN AFT ENTRY AISLE INOPERATIVE. REPLACED BATTERY POWER SUPPLY AT B5-27 FOR OVERHEAD EMERGENCY EXIT LIGHTS IN AFT ENTRY AISLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040269Battery Pack · dischargedSTL - CEILING EMERGENCY LIGHTS AT ROWS 11 THROUGH 26 INOPERATIVE. REPLACED BATTERY PACKS AT B5-102 AND B5-104 FOR CEILING EMERGENCY LIGHTS AT ROWS 11 THROUGH 26. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0480094Floor Panel · damagedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS BROKEN INSERTS AND MISSING MATERIAL AT FS 465-541. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480093Insert · missingOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS NUMEROUS MISSING, BROKEN AND CORRODED INSERTS AT FS 200-256. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480092Insert · corrodedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS CORRODED INSERTS AT FS 180-200. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480091Floor Panel · tornOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS TORN EDGE AT FS 160-200. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480090Floor Panel · crushedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL CORNER IS CRUSHED AT FS 905-977. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480089Floor Support · crackedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL SIDE SUPPORT IS CRACKED AND DEFORMED AT FS 826-886. REPLACED SUPPORT PER SRM 51-10-4. (M)SDR ASAA0480095Floor Panel · damagedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS EDGE SEALANT MISSING AT FS 864-886. RESEALED EFFECTED AREAS. (M)SDR ASAA0480097Floor Panel · corrodedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS CORRODED INSERTS AT FS 160-200. REPLACED PANEL PER SRM 53-05. (M)SDR ASAA0480096Floor Panel · damagedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS EDGE SEALANT MISSING AT FS 826-864. RESEALED EFFECTED AREAS. (M)SDR GTIA040142Uplock Hook · lack of lubeAFTER DEPARTURE LEFT GEAR LIGHT REMAINED RED WITH DOOR LIGHT OUT, COMPLIED WITH QRH. CYCLED GEAR, LIGHT WENT OUT. PERFORMED OPS CHECK OF PSEU AND FOUND NORMAL. CHECKED UPLOCK SENSOR ON MLG AND CHECKED 'GAP' AND FOUND NORMAL. LUBED UPLOCK HOOK MECH. (M)SDR GTIA040159Terminal · defectiveNUMEROUS EMERGENCY LIGHTS OUT IN CABIN. FOUND DEFECTIVE GROUND TERMINAL AT EMERGENCY LIGHT ASSY. REPAIRED TERMINAL LUG.SDR ASAA0480087Floor Panel · gougedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL IS GOUGED ALONG EDGE AT FS 905-977. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480086Floor Panel · corrodedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL HAS CORRODED INSERTS AT FS 200-256. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480085Floor Panel · gougedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR PANEL IS GOUGED AT EDGE AT FS 808-826. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480084Intercostal · crackedOKC - DURING HV6 CHECK, FOUND CABIN FLOOR INTERCOSTAL CRACKED AND BENT AT FS 1045. REPLACED INTERCOSTAL PER SRM 51-30-2. (M)SDR ASAA0480088Intercostal · gougedOKC - DURING HV6 CHECK, FOUND AFT CARGO BAY DOOR BEAM INTERCOSTAL IS CORRODED AT FS 1193. REPLACED INTERCOSTAL PER SRM 51-10-4. (M)SDR ASAA0480083Intercostal · corrodedOKC - DURING HV6 CHECK, FOUND AFT CARGO BAY DOOR BEAM INTERCOSTAL IS CORRODED AT FS 1165. REPLACED INTERCOSTAL PER SRM 51-10-4. (M)SDR GTIA040206Shear Tie · crackedFTW - FOUND AFT PIT SHEAR TIE CRACKED AT FS 1136 LONGERON 27R. REMOVED CRACKED SHEAR TIE. INSTALLED NEW SHEAR TIE. (M)SDR ASAA0480080Power Supply · inoperativeSJD - PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE. RESEATED ASSOCIATED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)SDR ASAA0480081Module · inoperativePHX - PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS FIRST 7 INOPERATIVE IN FIRST CLASS CABIN. RECONNECTED CONNECTOR. LIGTHS THEN OPERATED PROPERLY. (M)SDR GTIA040139Slide · out of positionLAS - FLT 1874 - L1 DOOR SLIDE PACK FELL OFF. REINSTALLED L1 DOOR SLIDE PACK. (M)SDR ASAA0480079Module · disconnectedPHX - FOUND EMEREGNCY FLOOR TRACK LIGHTS INOPERATIVE IN FIRST CLASS CABIN. RECONNECTED CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)SDR GTIA040205Floorboard · delaminatedFTW - FOUND MAIN CABIN F/B FS 1078-1155 LBL 30 IS DELAMINATED AND DAMAGED. FABRICATED NEW FLOORBOARD. (M)SDR MEX2004068Gcu · failedFLT 909 - MTY-MEX - AIRCRAFT RETURNED TO PLATFORM AS A CONSEQUENCE OF RIGHT ENGINE GENERATOR FAIL. THE APU WAS DEFERRED PREVIOUSLY SO THE GCU AND BCU WERE REPLACED BUT FAIL CHANGE TO LT ENGINE INDICATION. APU TRIM WAS ACCOMPLISHED AND IT WAS OPERATIVE. THE SDR AALA20040254Controller · inoperativeORD - INFLIGHT T2373/19 UPON TAKEOFF FROM MDW THE AIRCRAFT WOULD NOT PRESSURIZE AND THE STANDBY LIGHT ILLUMINATED. LANDED AT ORD WITHOUT INCIDENT. REPLACED NR 1 CONTROLLER. BITE CHECKED BOTH NR 1 AND NR 2 CONTROLLERS AND NO FAULTS NOTED. SYSTEM GROUND CHESDR GTIA040269Skin · wrinkledFTW - FOUND FUSELAGE EXTERIOR STATION 37-58.7 SKIN WRINKLED FROM STRINGER 18L TO 24 INCHES BELOW STRINGER. CUTOUT DAMAGED AREA AT STATION 50.67.5 FROM STRINGER 18L AND 14.4 INCHES DOWN. CUT OUT AREA. FABRICATED ONE EACH 49 SPLICE DOUBLER. FABRICATED ONE EASDR GTIA040216Seat Track · corrodedFTW - FOUND MAIN CABIN SEAT TRACK LBL 24 INCHES STATION 1307 TO STATION 1130 HAS CORROSION. REMOVED SEAT TRACK SECTION STATION 1068-1307. FABRICATED NEW SEAT TRACK. FABRICATED NEW SEAT TRACK. FABRICATED SPLICE SECTION REPAIR STATION 1140 AND 1260. INSTALLSDR GTIA040233Seat Track · corrodedFTW - FOUND MAIN CABIN SEAT TRACK RBL 24 INCHES STATION 200 TO 256 HAS CORROSION. REMOVED SEAT TRACK STATION 200 TO 265. LOCATED AND DRILLED NEW SEAT TRACK. INSTALLED SEAT TRACK. (M)SDR GTIA040175Structure · corrodedFTW - FOUND CABIN SUBFLOOR CORRODED FS 1173-1213 RBL 54. SUBFLOOR STATION 1183 TO 1188 IS OUT OF LIMITS. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)SDR ASAA0480075Lanyard · disconnectedSEA - FOUND FORWARD PAX L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR GTIA040202Seat Track · corrodedFTW - FOUND MAIN CABIN SEAT TRACK LBL 38 STATION 1136 TO STATION 1097 HAS CORROSION. REMOVED OUT OF LIMITS SEAT TRACK, LBL 38 STATION 1136-1097. FABRICATED NEW TRACK. INSTALLED TRACK. (M)SDR GTIA040201Seat Track · corrodedFTW - FOUND MAIN CABIN SEAT TRACK RBL 44 INCEHS STATION 200 TO 256 HAS CORROSION. SEAT TRACK RBL 44 STATION 200-245 OUT OF LIMITS. FABRICATED NEW SEAT TRACK SECTION AND SPLICE. INSTALLED SECTION OF SEAT TRACK AND SPLICE. (M)SDR GTIA040138Downlock Sensor · faultyFLL - FLT 705 - AFTER LANDING GEAR RETRACTION LEFT MAIN RED UNSAFE LIGHT REMAINED ON FOR APPROX 2 MINUTES GEAR DOOR LIGHT WAS OUT. TROUBLESHOT LEFT MAIN GEAR INDICATION, RUNG OUT WIRES TO THE SENSOR. WIRES CHECKED OK ALSO RAN AST, ON PSEU AND MONITOR TEST OFSDR AALA20040248Wire · damagedEGRESS EMERGENCY LIGHT AT ROW 16 INOPERATIVE. SPLICED WIRES UNDER SEAT FOR EMERGENCY EGRESS LIGHT AT ROW 16. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR GTIA040176Web · corrodedFTW - FOUND CABIN STATION 522-560 STRINGER 18L FLOOR WEB CORRODED. FLOOR WEB AT STATION 527 IS OUT OF LIMITS. REMOVED DAMAGE AREA. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)SDR GTIA040136Uplock Sensor · looseRED LEFT GEAR UNSAFE LIGHT ON AFTER RETRACTION, FOLLOWED QRH PROCEDURES AND LIGHT WENT OUT. FOUND LEFT GEAR UPLOCK SENSOR LOOSE. TIGHTENED SENSOR AND INSPECTED BRACKET AND SENSOR, INSTALLATION FOUND TO BE NORMAL. ALSO, PERFORMED PROX TEST OF UPLOCK SENSOR, SDR ASAA0480074Intercostal · corrodedOKC - DURING HV1-CHECK, FOUND INTERCOSTAL CORRODED AT FS 1212-1231. REPLACED INTERCOSTAL PER SRM 51-30-5. (M)SDR ASAA0480073Release Mech · brokenDURING HV1 CHECK, FOUND TAILCONE RELEASE MECHANISM BROKEN. REPLACED MECHANISM PER MM 53-53-02. (M)SDR ASAA0480076Skin · gougedOKC - DURING HV1-CHECK, FOUND VERTICAL STABILIZER SKIN GOUGED JUST ABOVE HORIZONTAL STABILIZER RIGHT PIVOT POINT. REPLACED SKIN PER SRM 51-30-1 AND 51-30-2. (M)SDR ASAA0480077Splice Plate · bentOKC - DURING HV1 CHECK, FOUND RIGHT WING 0 TO 1 SLAT SPLICE PLATE UPPER END IS BENT. REPLACED SPLICE PLATE PER SRM 51-10-4 AND 57-50-13. (M)SDR AALA20040233Sign · unserviceableDFW - LEFT HAND EMERGENCY LIGHT EXIT MARKER AT FORWARD OVERWING EXIT UNREADABLE. REPLACED LEFT HAND EMERGENCY LIGHT EXIT MARKER AT FORWARD OVERWING EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040232Light · inoperativeDFW - FORWARD EMERGENCY LIGHT ARROW INOPERATIVE. REPLACED FORWARD EMERGENCY ARROW LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040241Sign · unserviceableDFW - EMERGENCY LIGHT EXIT MARKER AT RIGHT AFT OVERWING EXIT UNREADABLE. REPLACED EMERGENCY LIGHT EXIT MARKER AT RIGHT AFT OVERWING EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0480192Power Supply · not seatedSEA - DURING PREFLIGHT CHECK, FOUND COCKPIT OVERHEAD EMERGENCY FLOOD LIGHTS INOPERATIVE. RESEATED ASSOCIATED BATTERY PACK, POWER SUPPLY. LIGHTS THEN OPERATED NORMALLY. (M)SDR GTIA040198Nose Cowl · corrodedFTW - FOUND NR 1 ENGINE NOSE COWL LIPPING CORRODED AT 1:00 AND 5:00 O'CLOCK POSITION. FOUND CORROSION OUT OF LIMITS. REMOVED NOSE COWL. INSTALLED THE NR 1 ENGINE NOSE COWL. (M)
Back to Douglas DC-9-83