What was found
FTW - FOUND CABIN SUBFLOOR CORRODED FS 1173-1213 RBL 54. SUBFLOOR STATION 1183 TO 1188 IS OUT OF LIMITS. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND CABIN SUBFLOOR CORRODED FS 1173-1213 RBL 54. SUBFLOOR STATION 1183 TO 1188 IS OUT OF LIMITS. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)