Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20131012004Fitting · crackedLT LAVATORY, STATION 1338 & LONGERON 14 LT, LONGERON END FITTING CRACKED. INSTALLED NEW STRINGER END CAP FITTING AT STATION 1338 & LONGERON 14 LT IAW AARD 51-00-05-1.SDR WX0A2013101401721Frame · corrodedE & E BAY FRAME, BS 180 CORRODED BETWEEN LONGERONS 29L TO 29R. REMOVED DAMAGED SECTION OF FRAME. FABRICATED REPAIR, LOCATED, DRILLED AND INSTALLED IAW SRM 53-03, FIG 2A.SDR AALA20131011009Strap · damagedSCREW GOUGE IN WEB STRAP AT STATION 429 & LONGERON 28 RT. INSTALLED NEW STRAP IAW SRM 51-01-00.SDR AALA20131011008Stringer · crackedAFT CARGO STRINGER TIE CRACKED BETWEEN STATIONS 1193 TO 1212 & LONGERON 29 LT. INSTALLED LONGERON SPLICE IAW AARD 51-10-00-5.SDR AALA20131011007Stringer · crackedAFT CARGO STRINGER TIE CRACKED, BETWEEN STATIONS 1193 TO 1212 & LONGERON 28 LT. INSTALLED LONGERON SPLICE IAW AARD 51-10-00-5.SDR AALA20131011006Skin · damagedSMALL PUNCTURE ON UPPER RT LE SIDE OF RUDDER. ACCOMPLISHED REPAIR IAW SRM 51-70-01A, WET LAYUP.SDR AALA20131011005Support Bracket · crackedAFT ENTRY RT JAMB SUPPORT BRACKET CRACKED 5 INCHES ABOVE WL FWD OF AFT PRESSURE BULKHEAD. INSTALLED NEW SERVICEABLE SUPPORT BRACKET WEB IAW AARD 53-00-05-1.SDR AALA20131011004Angle · corrodedCORROSION ON CUSP ANGLE FROM STATIONS 830-840. INSTALLED CUSP ANGLE FILLER & DOUBLER IAW AARD 53-20-00-16.SDR AALA20131011003Membrane · corrodedCORROSION ON SUBFLOOR DOUBLER FROM STATIONS 200 TO 204 RT. INSTALLED SUBFLOOR DOUBLER FROM STATIONS 200 TO 207 RT.SDR WX0A2013101400723Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYSTEM OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR WX0A2013101400722Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20131010008Seat Track · corrodedSEVERAL AREAS OF CORROSION ON SEAT TRACK 6 FROM STATIONS 200 TO 385. REPLACED NR 6 SEAT TRACK FROM STATIONS 200 TO 455 IAW SRM 53-05-00 FIGURE 4.SDR AALA20131010007Cusp Web · corrodedINTERGRANULAR CORROSION FROM STATIONS 1185 TO 1186 ON RT CUSP. INSTALLED REPAIR DOUBLER IAW AARD 53-20-00-16.SDR AALA20131010006Cusp Web · corrodedINTERGRANULAR CORROSION FROM STATIONS 1165 TO 1166 ON RT CUSP. INSTALLED CUSP DOUBLER IAW AARD 53-20-00-16 & SRM 51-30-05.SDR YYFA20131009001Button · inoperativeAFT L2 INTERPHONE, CREW TO CREW BUTTON DOES NOT WORK, ON DONG OR LIGHT.SDR AALA20131015008Membrane · corrodedCORROSION ON SUBFLOOR BELOW G-1 GALLEY DRAIN PAN BETWEEN STATIONS 148 TO 160 AND RBL 50. CUT OUT CORROSION & INSTALLED DOUBLER IAW AARD 53-20-00-16.SDR AALA20131015007Fitting · corrodedG-1 GALLEY OTBD TIE DOWN FITTING AFT OF GALLEY DRAIN PAN CORRODED. INSTALLED NEW G-1 GALLEY TIE DOWN FITTING.SDR AALA20131015006Fitting · corrodedG-2 GALLEY INBD TIE DOWN FITTING CORRODED APPROXIMATE LOCATION STATION 210. NEW GALLEY TIE DOWN FITTING WAS INSTALLED IAW DRAWING 9936535 & IPC 53-40-00-08D.SDR YYFA20131008003Brake · overtempNR 3 BRAKE, HIGH TEMP AFTER GEAR RETRACTION. CREW ACCOMPLISHED QRH PROCEDURES. TEMP BELOW 250 DEGREES C FIRST 30 MINUTES. TEMP, BELOW 200 DEGREES C THE REST OF THE SECTOR. NR 3 MAIN TIRE BLEW ON LANDING AND NR 4 MAIN TIRE REQUIRES REPLACEMENT DUE TO NR 3SDR AALA20131008006Cusp Web · crackedCRACK IN RT CUSP AT STATION 259 UNDER NR 6 SEAT TRACK. INSTALLED DOUBLER IAW AARD 53-20-00-16.SDR AALA20131008003Cusp Web · corrodedRT CUSP CORRODED FROM STATIONS 503 TO 598. REPLACED RT CUSP SHEET IAW AARD 51-00-05-1.SDR YYFA201310080001Handset · malfunctionedRC P/A HAS FEEDBACK. L2 P/A HAS FEEDBACK. REMOVED HANDSET, SYS OPS CHECKED GOOD IAW 23-30-00.SDR AALA20131007005Longeron · crackedLONGERON 4L CRACKED AT STATION 207. INSTALLED LONGERON SPLICE REPAIR FROM STATION 168LH TO STATION 228LHSDR AALA20131006004Pan · crackedLT WINDOW PAN CRACKED AT TOP AFT CORNER BS 1079. INSTALLED DOUBLER IAW AARD 53-10-00-25.SDR AALA20131006003Pan · crackedLT WINDOW PAN CRACKED AT TOP AFT CORNER BS 1060. INSTALLED DOUBLER IAW AARD 53-10-00-25.SDR AALA20131006002Pan · crackedLT WINDOW PAN CRACKED AT TOP FWD CORNER, BS 1022. INSTALLED DOUBLER IAW AARD 51-10-00-25.SDR AALA20131005004Stop Fitting · crackedFOUND CRACKED DOOR STOP FITTING ON RT SIDE, WL+36 OF VAULT DOOR JAMB. REPLACED DOOR STOP FITTING.SDR AALA20131005002Pan · crackedWINDOW PAN IS CRACKED TOP AFT CORNER AT BS 1193. INSTALLED REPAIR DOUBLER IAW AARD 53-10-00-25.SDR AALA20131005001Pan · crackedRT WINDOW PAN CRACKED TOP AFT CORNER AT BS 1117. INSTALLED REPAIR DOUBLER IAW AARD 53-10-00-25.SDR WX0A20131007718Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20131004010Data Unit · failedSTL INFLIGHT DFW-MKE. CREW REPORTED DURING FUEL CHECK IN FLIGHT, FUEL QUANTITIES WERE ERRATIC. FLIGHT DIVERTED STL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. CHECKED AIRCRAFT FUELING PANEL & FOUND LT HAND, RT HAND & CENTER TANK FUEL VALUES WERSDR AALA20131004006Battery Pack · dischargedOVERHEAD EMERGENCY EXIT LIGHTS FROM ROWS 8 TO 11 REMAIN ON AFTER POWER HAS BEEN REMOVED. REPLACED BATTERY PACK ST ROW 8E/F BIN. OPERATIONS CHECKED NORMAL.SDR AALA20131004008Pan · crackedLT WINDOW PAN CRACKED TOP FORWARD AT BS 846. ACCOMPLISHED REPAIR IAW AARD 53-10-00-25.SDR AALA20131004005Pan · crackedRT WINDOW PAN IS CRACKED AT TOP AFT AT BS 1079. INSTALLED REPAIR DOUBLER.SDR WX0A20131004715Cusp Web · crackedAFT CABIN FLOOR CUSP IS CRACKED AT LT BETWEEN BS 1287 & 1309. CUT OUT DAMAGED WEB, FABRICATED FILLER & DOUBLER AND INSTALLED REPAIR PARTS IAW SRM 53-05, FIG 131A.SDR AALA20131003010Pan · crackedRT WINDOW PAN IS CRACKED AT LOWER FWD CORNER AT BS 1155. INSTALLED DOUBLER IAW AARD 53-10-00-25.SDR AALA20131003009Pan · crackedRT WINDOW PAN IS CRACKED AT LOWER FWD CORNER AT BS 1136. ACCOMPLISHED REPAIR IAW AARD 53-10-00-25.SDR AALA20131003008Pan · crackedRT WINDOW PAN IS CRACKED AT TOP AFT CORNER AT BS 1098. INSTALLED REPAIR ANGLE DOUBLER IAW AARD 53-10-00-25.SDR AALA20131003007Pan · crackedLT WINDOW PAN IS CRACKED AT TOP FWD AT BS 846. INSTALLED REPAIR ANGLE IAW AARD 53-10-00-25.SDR AALA20131003005Rib · crackedNR 5 SLAT, LT RIB NR 15 SHOWS CRACK INDICATION. INSTALLED NEW ATTACH FITTING IAW AARD 51-00-05.SDR AALA20131003004Rib · crackedLT NR 14 SLAT RIB SHOWS A CRACK INDICATION. INSTALLED NEW ATTACH FITTING IAW AARD 51-00-05-1 REPAIR 1.SDR YYFA20131003001Warning Light · illuminatedRT GENERATOR INOPERATIVE LIGHT CAME ON DURING FLT. COMPLETED QRH STARTED APU TO POWER RT BUSS.SDR AALA20131002008Skin · crackedFS SKIN ON RT SIDE CRACK EXTENDING FROM FASTENER HOLE TO BS 1380 JUST ABOVE LONGERON 14 RT. REMOVED DAMAGE & INSTALLED DOUBLER IAW SRM 53-01-00 FIGURE 4.SDR WX0A20131004716Battery · inoperativeAFT F/A FLASHLIGHT RED LIGHT DOES NOT BLINK. R & R FLASHLIGHT BATTERY IAW AMM 25-60-00, OPS CHECKED GOOD.SDR WX0A20131004714Cusp Web · crackedFWD CABIN FLOOR CUSP WEB IS CRACKED AT FS 229 TO 237 LBL 18. CUT OUT DAMAGED AREA, FABRICATED REPAIR DOUBLER & FILLER AND INSTALLED REPAIR PARTS IAW SRM 53-05, FIG 131 A-14.SDR WX0A20131004713Frame · chafedAPU COMPT FWD FRAME AT FS X=1350 IS CHAFED THRU AT RT CORNER AT THE APU ANGLE AT AIR INTAKE FLANGE. FABRICATED REPAIR ANGLE AND INSTALLED REPAIR IAW (STS) EA 05-2013-094.SDR WX0A20131004712Frame · chafedAPU FWD SHROUD IS CHAFING AT FWD LT CORNER OF THE APU ANGLE TO FUSELAGE SKIN AT AIR INTAKE FLANGE. FABRICATED NEW REPAIR ANGLE AND INSTALLED REPAIR IAW (STS) EA 05-2013-094.SDR AALA20130930001Battery Pack · inoperativeCABIN EMERGENCY BATTERY PACK INOPERATIVE. REPLACED BATTERY PACK FOR CABIN EMERGENCY LIGHTS. OPERATIONS CHECKED NORMAL.SDR WX0A201310021711Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR YYFA20130929001Slide · unwanted deployWHEN OPENING L2 DOOR TO CLEAN TRASH FROM GALLEY THE DOOR SLIDE WAS DEPLOYED. R & R L2 DOOR SLIDE IAW MM 25-62-00.
Back to Douglas DC-9-83