Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20130914011Cusp Web · corrodedFOUND CORROSION ON RT HAND CUSP SHEET FROM STATIONS 218 TO 237. INSTALLED SERVICEABLE CUSP SHEET IAW AARD 51-00-05-1.SDR AALA20130910016Cusp Web · puncturedPUNCTURE IN THE LT HAND CUSP AT STATION 230 UNDER THE OTBD LEG OF THE NR 1 SEAT TRACK. INSTALLED DOUBLER IAW SRM 51-30 & AARD 53-20-00-16.SDR AALA20130910003Clamp · looseORD CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. EMERGENCY DECLARED FLIGHT RETURNED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND LT HAND PACK HEAT EXCHANGER OUTLET DUCT CLAMP LOOSE. ADJUSTED BOOT & TIGHTENED CLSDR WX0A2013091271695Battery · dischargedFWD DEFIBULATOR BATTERY LOW. R & R DEFIBILLATOR BATTERY IAW AMM 25-60-01, SELF TEST GOOD, OK FOR SERVICE.SDR WX0A2013091271694Battery · dischargedFWD AED BATTERY CHARGE LOW. R & R FWD CABIN AED ASSY. REF AMM 25-60-00.SDR WX0A2013091271693Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYSTEM OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20130909007Longeron · crackedOVERWING LONGERON 20 LT IS CRACKED AT THE AFT OTBD SIDE OF THE WW ABOVE THE FLAP BUS CABLES. INSTALLED DOUBLER REPAIR IAW AARD 53-10-00-18.SDR AALA20130909004Shear Tie · corrodedCORROSION ON SHEAR TIE AT STATION 1231 & LONGERONS 30 TO 29 RT. REPLACED SHEAR TIE IAW AARD 51-00-05-1.SDR AALA20130908006Cusp Web · puncturedRT CUSP HAS SMALL PUNCTURE UNDER NR 6 SEAT TRACK AT STATION 515. INSTALLED DOUBLER REPAIR IAW AARD 53-20-00-16.SDR AALA20130908004Seat Track · corrodedSEAT TRACK NR 1 CORRODED FROM STATIONS 1174 TO 1309. REMOVED & INSTALLED NEW SERVICEABLE SEAT TRACK FROM STATIONS 1174 TO 1309 IAW AMM 53-40-01.SDR AALA20130908003Seat Track · corrodedMULTIPLE AREAS OF CORROSION ON NR 6 SEAT TRACK FORM STATIONS 207 TO 589. REPLACED SEAT TRACK IAW MM 53-40-01-2.SDR AALA20130908002Tie Down · corrodedGALLEY NR 4 GALLEY TIE DOWN IN SEAT TRACK NR 1 AT STATION 1174 CORRODED. REMOVED & INSTALLED NEW SERVICEABLE NR 4 GALLEY TIE DOWN IN SEAT TRACK NR 1 AT STATION 1174 IAW AMM 53-40-01.SDR AALA20130908001Seat Track · corrodedCORROSION ON NR 6 SEAT TRACK FROM STATIONS 598 TO 788. REPLACED SEAT TRACK IAW AARD 51-00-05-1.SDR AALA20130907022Seat Track · corrodedCORROSION ON NR 2 SEAT TRACK FROM STATIONS 1200 TO 1202. INSTALLED SPLICE REPAIR IAW SRM 53-05-00 FIGURE 4F & SRM 51-30-05.SDR AALA20130907021Seat Track · corrodedCORROSION ON NR 4 SEAT TRACK FROM STATIONS 263 TO 266. INSTALLED PLUG REPAIR IAW AARD 53-20-00-10.SDR AALA20130907020Seat Track · corrodedCORROSION ON NR 4 SEAT TRACK FROM STATIONS 283 TO 287. INSTALLED PLUG REPAIR IAW AARD 53-20-00-10.SDR AALA20130907019Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED AT STATION 787 & BL 0. INSTALLED SERVICEABLE INTERCOSTAL IAW AARD 51-00-05-1.SDR AALA20130907018Seat Track · corrodedCORROSION ON NR 5 SEAT TRACK FROM STATIONS 203 TO 246. INSTALLED NEW SECTION OF SEAT TRACK IAW SRM 53-05-00 FIGURE 4F.SDR AALA20130907017Seat Track · corrodedCORROSION ON NR 1 SEAT TRACK FROM STATIONS 484 TO 486. INSTALLED REPAIR PLUG IAW AARD 53-20-00-10.SDR AALA20130907016Seat Track · corrodedCORROSION ON NR 1 SEAT TRACK AT STATIONS 469 TO 472. INSTALLED REPAIR PLUG IAW AARD 53-20-00-10.SDR AALA20130907015Cargo Track · corrodedCORROSION ON RT TIE DOWN TRACK IN AFT CARGO FROM STATIONS 1231 TO 1250. INSTALLED DOUBLER STRAP IAW AARD 53-20-00-13.SDR AALA20130907014Seat Track · corrodedCORROSION ON NR 6 SEAT TRACK FROM STATIONS 266 TO 796. ACCOMPLISHED SPLICE REPAIR IAW AARD 53-20-00-01 & AMM 53-40-01-201.SDR AALA20130907013Seat Track · corrodedCORROSION ON NR 6 SEAT TRACK AT STATION 1122. ACCOMPLISHED PLUG REPAIR IAW SRM 53-05-00 FIGURE 4A.SDR AALA20130907012Seat Track · corrodedCORROSION ON NR 6 SEAT TRACK AT STATION 1091. ACCOMPLISHED PLUG REPAIR IAW SRM 53-05-00 FIGURE 4.SDR AALA20130907011Pan · crackedRT WINDOW RING PAN CRACKED AT UPPER TAB, STATION 1097. INSTALLED REPAIR ANGLE IAW AARD 53-10-00-25.SDR AALA20130907010Pan · crackedRT WINDOW RING PAN CRACKED AT UPPER TAB, STATION 1059. INSTALLED REPAIR ANGLE IAW AARD 53-10-00-25.SDR AALA20130907009Pan · crackedRT WINDOW RING PAN CRACKED AT UPPER TAB, STATION 1040. INSTALLED REPAIR ANGLE IAW AARD 53-10-00-25.SDR AALA20130907008Pan · crackedRT WINDOW RING PAN CRACKED AT UPPER TAB, STATION 1021. INSTALLED ANGLE DOUBLER IAW AARD 53-10-00-25.SDR AALA20130907007Pan · crackedRT WINDOW RING PAN CRACKED AT UPPER TAB, STATION 846. INSTALLED ANGLE DOUBLER IAW AARD 53-10-00-25.SDR AALA20130907006Pan · crackedLT WINDOW RING PAN CRACKED AT UPPER AFT TAB, STATION 1089. INSTALLED ANGLE DOUBLER IAW AARD 53-10-00-25.SDR AALA20130907005Pan · crackedLT WINDOW RINGPAN CRACKED AT UPPER AFT TAB, STATION 1060. INSTALLED ANGLE DOUBLER IAW AARD 53-10-00-25.SDR AALA20130907004Pan · crackedCRACK ON WINDOW PAN, LT SIDE AT STATION 332 UPPER FWD CORNER. INSTALLED ANGLE DOUBLER IAW AARD 53-10-00-25.SDR YYFA20130907001Latch · out of adjustAT 800AGL MID CARGO DOOR LIGHT CAME ON. ADJUSTED MID CARGO DOOR LATCH IAW AMM AND LIGHT EXTINGUSHED.SDR WX0A2013091271691Flashlight · inoperativeFWD GALLEY REMOVABLE FLASHLIGHT INOPERATIVE. R & R FWD GALLEY FLASHLIGHT REPLACED IAW AMM 33-53-00. OPS CHECKED GOOD.SDR WX0A2013091271690Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED ACCOMPLISHED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20130906022Seat Track · corrodedNR 6 SEAT TRACK AT STATION 1185 CORRODED. INSTALLED SEAT TRACK PLUG IAW AARD 53-20-00-10.SDR YYFA20130906001Pa System · malfunctionedPA SYS MAKES STATIC SOUND.SDR WX0A2013091271689Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20130905028Cusp Web · crackedLT CUSP CRACKED AT STATION 830. INSTALLED REPAIR DOUBLER IAW SRM 53-20-00 FIGURE 16.SDR AALA20130905007Skin · damagedVERTICAL STABILIZER AT STATION ZFS 52.267 HAS MULTIPLE HOLES THAT WERE FOUND TO BE DISTRESSED ON THE UPPER & LOWER LE. DOUBLERS WERE INSTALLED ON THE UPPER & LOWER LE IAW SRM 55-03-00.SDR WX0A2013091071688Seat Track · corrodedSEAT TRACK HAS CORROSION AT LBL 44 BETWEEN FS 1136 AND 1139. REPAIRED SEAT TRACK IAW SRM 53-05.SDR WX0A201309107187Pan · corrodedFLOOR PAN CORRODED BETWEEN BS 148.55 AND 160.00. REPAIRED AREA IAW SRM 53-01.SDR AALA20130904026Cusp Web · crackedLT CUSP IS CRACKED & PUNCTURED AT STATION 288. INSTALLED DOUBLER IAW AARD 53-20-00-16.SDR YYFA20130927001Engine · bird ingestionBIRD STRIKE ON NR 1 ENG. REMOVED NR 1 ENG INTERNAL DAMAGE.SDR AALA20130912006Slide · damagedDURING PREFLIGHT, FOUND GIRT BAR AT SERVICE DOOR OUT & PINS EXPOSED. FOUND ALL PINS PULLED OUT OF SLIDE & GIRT BAR HANGERS BENT DOWN. REPAIRED HANGERS & REPLACED SLIDE ASSEMBLY.SDR WX0A2013091271692Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACKS AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20130905009Pan · crackedCABIN CRACK IN LT TOP FWD CORNER OF WINDOW PAN STATION 946. ACCOMPLISHED NESTED ANGLE REPAIR IAW AARD 53-10-00-25.SDR AALA20130903008Frame · crackedFS FRAME CRACKED AT FWD SIDE OF STATION 1322 & LONGERON 17 RT. ACCOMPLISHED NESTED ANGLE REPAIR IAW SRM 53-03-00 FIGURE 51.SDR AALA20130903007Frame · crackedFS FRAME FWD SIDE IS CRACKED AT STATION 1322 & LONGERON 17 LT. ACCOMPLISHED NESTED ANGLE REPAIR IAW SRM 53-03-00 FIGURE 51.SDR AALA20130903006Cusp Web · corrodedCORROSION ON LT CUSP FROM STATIONS 256 TO 259. INSTALLED DOUBLER IAW SRM 53-05-00 FIGURE 131A-21.
Back to Douglas DC-9-83