Embraer EMB-120ER
Service difficulty reports · 8,287
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB120ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB120ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201230455Window · lack of lubeUNABLE TO OPEN FIRST OFFICER'S DIRECT VISION WINDOW. (FLT 5487) LUBRICATED FIRST OFFICER'S DIRECT VISION WINDOW.SDR GLBA2012041901Door · out of rigCABIN DOOR HARD TO OPEN FROM INSIDE. RIGGED MAIN DOOR AND REPLACED BUSHINGS, OPS CHECKED GOOD.SDR SWIA201230451Lens · missingEMERGENCY EXIT SIGN LENS COVER AT SEAT 6A IS MISSING. (FLT 6414) REPLACED EMERGENCY EXIT SIGN ASSEMBLY AT SEAT 6A.SDR SWIA201230449Handle · dirtyMAIN CABIN DOOR DIFFICULT TO OPERATE. (FLT 5511) CLEANED AND LUBED MAIN CABIN DOOR OUTER AND INNER HANDLES, AND LUBED BOTH FWD AND AFT HINGE ARMS.SDR SWIA201230433Wire · unsecureOVERHEAD EMERGENCY EXIT SIGN AT ROW 9 IS OUT. (FLT 5432) RE-SECURED WIRING ON EMERGENCY EXIT SIGN.SDR SWIA201230408Light · inoperativeFLOOR EMERGENCY LIGHT AT 3A IS OUT. (FLT 5529) RELAMPED EMERGENCY LIGHT.SDR SWIA201230406Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 7 IS OUT. (FLT 6446) RELAMPED EMERGENCY LIGHT.SDR SWIA201230337Stringer · corrodedAFT END OF STRINGER 20L LEFT CENTER FUSELAGE HAS CORROSION. REPAIRED AFT END OF STRINGER 20L LEFT CENTER FUSELAGE IN REFERENCE TO SRM.SDR SWIA201230336Frame · crackedCORROSION AND CRACK COMING FROM RIVET HOLE AT FRAME 23 FORWARD FUSELAGE RIGHT LOWER SIDE. REPAIRED DAMAGE AT FRAME 23 FORWARD FUSELAGE RIGHT LOWER SIDE.SDR SWIA201230747Skin · corrodedCORROSION FOUND AT FRAME 37 AND STRINGER 21R AND TITANIUM STRAP IS LIFTED. (C-CHECK) REPAIRED AREA OF CORROSION ON FUSELAGE SKIN AT FRAME 37 AND STRINGER 21R IN REFERENCE TO ETD.SDR SWIA201230400Acm · defectiveLEFT PACK BLOWS SMOKE IN THE COCKPIT. (SERVICE) REPLACED LEFT ACM. PN OFF 2204540-2, SN OFF 124-107SDR SWIA201230308Lamp · burned outFLT 5614, NR 1 OVERHEAD EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT.SDR SWIA201230358Fixture · failedEMERGENCY EXIT ROW SIGN AT 9C IS INOPERATIVE. (FLT 7777) REPLACED EMERGENCY LIGHT FIXTURE. PN: 10-1110-5, SN OFF: NSNSDR SWIA201230352Lamp · burned outFLT 5574, OVERHEAD EMERGENCY LIGHT AT ROW 9 IS OUT. RELAMPED EMERGENCY LIGHT.SDR SWIA201230415Light · inoperativeFLOOR ESCAPE PATH WHITE FLOOR EMERGENCY LIGHT AT 9A IS OUT. (FLT 5432) RELAMPED EMERGENCY LIGHT.SDR SWIA201230545Floor Support · corrodedCORROSION ON LEFT OMEGA BEAM NEAR PASSENGER DOOR ENTRANCE. (C-CHECK) REPLACED LEFT OMEGA BEAM IN REFERENCE TO EMB 120 SRM.SDR SWIA201230255Floor Support · corrodedFORWARD FUSELAGE LEFT OMEGA BEAM AT FUSE FRAME 14 HAS CORROSION BETWEEN STATION 4410.5 AND 4825.5. (SERVICE) REPLACED FORWARD FUSELAGE LEFT OMEGA FLOORBEAM IN REFERENCE TO 120 SRM.SDR SWIA201230254Buttstrap · corrodedHEAVY CORROSION ON BUTT STRAP BETWEEN STATIONS 4214.0 AND 4992.0 AT PASSENGER DOOR ENTRY WAY FORWARD FUSELAGE. (SERVICE) REPLACED TWO LEFT CENTER FORWARD BUTT STRAPS BETWEEN FRAMES 13A AND 21, LEFT CENTER T-PROFILE FLOOR SUPPORT IN REFERENCE TO 120 SRM.SDR GLBA201203281Fan · smokeA/C PACKS SMOKE ON GROUND. MX REPLACED THE LT GROUND COOLING FAN, OPS CHECKED GOOD REF MM 21-51-03.SDR SWIA201230548Buttstrap · corrodedSURFACE CORROSION ON LEFT CABIN BUTT STRAP NEAR PASSENGER DOOR ENTRANCE. (C-CHECK) REPLACED AFFECTED BUTT STRAP IN REFERENCE TO EMB 120 SRM.SDR SWIA201230231Light · inoperativeFLOOR EMERGENCY LIGHT AT ROW 10 IS OUT. (FLT 6232) RELAMPED EMERGENCY LIGHT.SDR SWIA201230175Roller · failedFLAP DISAGREEMENT. (FLT 7777) REPLACED OUTBOARD FLAP TRACK ROLLER.SDR GN0A201204010324Fuel Filter · dirtyON TAKEOFF FROM ATLANTIC CITY (ACY), CREW RECEIVED AN AURAL WARNING CHIME ALONG WITH WARNING LIGHT ON THE MULTIPLE ALARM PANEL FUEL AND THE RIGHT ENGINE FUEL FILTER LIGHT ILLUMINATION. THE TAKEOFF WAS ABORTED AND THE AIRCRAFT RETURNED TO THE GATE WITHOUT FURTSDR SWIA201230151Light · inoperativeEMERGENCY LIGHT BELOW FLIGHT ATTENDANT JUMPSEAT IS OUT. (FLT 7765) RELAMPED EMERGENCY LIGHT.SDR SWIA201230377Light · inoperativeLOWER OUTER TAIL NAV LIGHT IS OUT. (FLT 5450) RELAMPED NAV LIGHT.SDR SWIA201230142Wire · damagedONE FORWARD DOOR RED EMERGENCY FLOOR LIGHTING IS OUT. (FLT 6506) REPAIRED DAMAGED WIRING.SDR SWIA201230149Wire · brokenEXIT SIGN ON BIN DOOR AT ROW 9 IS OUT. (SERVICE) REPAIRED BROKEN WIRE.SDR 3MNB20121212001Oil System · low pressureEXPERIENCED AN IN-FLIGHT SHUTDOWN OF THE LT ENGINE DUE TO LOW OIL PRESSURE. SHUTDOWN ENGINE & LANDED. ENGINE NEEDED 8 QUARTS OF OIL TO REFILL RESERVOIR.SDR SWIA201230177Wire · brokenTHE CABIN FLOOR EMERGENCY LIGHTS BETWEEN ROW 3 AND 6 DO NOT ILLUMINATE. (FLT 5478) REPAIRED BROKEN WIRE BELOW FLOOR AT ROW 5.SDR GLBA2012031401Spar Cap · damagedMAJOR REPAIR - DURING A SCHEDULED ROUTINE INSPECTED, FOUND THE RT WING MAIN WING LWR SPAR CAP BETWEEN RIBS 17 & 18 IS NOT CRACKED BUT FOUND THAT THE MINIMUM INTER-RIVET PITCH IS 12-15MM WHILE PERFORMING SB 120-57-0036 AND PT I/FCD 120-57-036. REPAIRED IAW EOSDR SWIA201230439Skin · corrodedCORROSION AT LEFT SIDE LOWER FUSELAGE SKIN BETWEEN FRAMES 19 AND 20 EXTERIOR. (C-CHECK) REPAIRED BY INSTALLING REINFORCING AND FILLER SECTIONS IN REFERENCE TO EMB 120 SRM.SDR SWIA201230440Buttstrap · corrodedCORROSION ON CABIN CENTER BUTT STRAP NEAR LAV AREA. (C-CHECK) REPLACED CENTER BUTT STRAP NEAR LAV AREA IN REFERENCE TO EMB 120 SRM.SDR SWIA201230438Stringer · crackedLEFT WING, LOWER STRINGER 10 CRACKED NEAR FORWARD ENGINE FIRE BOTTLE BAY ACCESS CUTOUT AREA. (C-CHECK) REPLACED DAMAGED INBOARD LOWER SECTION OF LEFT WING STRINGER 10 IN REFERENCE TO 120 SRM.SDR SWIA201230032Sign · looseEXIT SIGN AT SEAT 5A COMING LOOSE. (FLT 5553) REPLACED EMERGENCY EXIT SIGN AT SEAT 5A.SDR SWIA201229983Selector · failedGEAR WOULD NOT EXTEND. GEAR CAME DOWN USING ELECTRIC OVERRIDE PROCEDURE. (FLT 5304) REPLACED GEAR SELECTOR HANDLE. P/N 120-38594-001 S/N OFF 120148SDR SWIA201229978Sign · unsecureEXIT SIGN AT 6A FELL OFF OVER PASSENGER SEAT. (FLT 6262) RE-SECURED EXIT SIGN OVER PASSENGER SEAT 6A.SDR SWIA201230107Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 9 IS OUT. (C-CHECK) RELAMPED EMERGENCY LIGHT.SDR SWIA201229967Sign · brokenEXIT SIGN AT 6A BROKEN. (FLT 5470) REPLACED EXIT SIGN ASSEMBLY AT 6A.SDR SWIA201229984Altimeter · failedON TAKEOFF CAPTAINS ALTIMETER WAS STUCK TILL 4500 FT THEN WOULD MOVE IN SEGMENTS OF 50 TO 100 FEET EVERY SECOND. (FLT 7760) REPLACED CAPTAIN'S ALTIMETER IN REFERENCE TO AMM. P/N: 1190AMI S/N OFF: AG299SDR SWIA201229912Control Handle · failedLANDING GEAR WILL NOT EXTEND WHEN GEAR HANDLE IS SELECTED DOWN. MUST BE HELD DOWN UNTIL GEAR IS EXTENDED. (FLT 6389) REPLACED LANDING GEAR HANDLE. PN OFF: 120-38594-501 SN OFF: 120294.SDR GLBA2012030201Skin · crackedMAJOR REPAIR - DURING A SCHEDULED ROUTINE INSPECTION, FOUND A CRACK IN THE RT OTBD LWR WING SKIN, FROM OB CORNER OF THE INBD FUEL PANEL ACCESS OPENING, RADIATES AFT & OTBD TO WS 4113.5, 2.1" IN LENGTH. REPAIRED IAW EO 12-120-57-005.SDR SWIA201230547Structure · corrodedCORROSION UNDER FRAME 36 JUST OUTBOARD OF STRINGER 21L AFT LOWER FUSELAGE. (C-CHECK) REPAIRED DAMAGED AREA AT FRAME 36 JUST AFT OF LOWER FUSELAGE.SDR SWIA201230546Structure · corrodedCORROSION FOUND UNDER FRAME 38 JUST OUTBOARD OF STRINGER 21R AFT LOWER FUSELAGE. (C-CHECK) REPAIRED DAMAGED AREA AT FRAME 38 JUST OUTBOARD OF STRINGER 21R.SDR SWIA201229858Switch · failedMAIN CABIN DOOR DOES NOT OPEN USING HYDRAULICS. (FLT 6220) REPLACED FORWARD DOOR CONTROL MICROSWITCH.SDR SWIA201229891Pin · backed outFIRST FOUR FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. (FLT 6359) FOUND FORWARD FLOOR EMERGENCY LIGHT CONNECTOR PIN OUT. PUSHED PIN IN PLACE.SDR SWIA201229835Duct · blownRIGHT ENGINE OVERWING BLEED DUCT BLOWN OUT. (FLT 5638) REPLACED RIGHT BLEED DUCT AT RIGHT WING TO FUSELAGE SIDE PANEL.SDR SWIA201229838Stringer · corrodedFUSELAGE STRINGERS 21L AND 21R CORRODED. (SERVICE) REPLACED STRINGERS 21L AND 21R IN REFERENCE TO EMB SRM.SDR SWIA201229824Control Module · failedUSED DOWNLOCK RELEASE TO GET GEAR TO RETRACT. (FLT 6263) REPLACED LANDING GEAR CONTROL MODULE PER AMM. PN 120-38594-501 SN OFF: 366605SDR SWIA201229754Fixture · defectiveDETECTED ODOR OF ELECTRICAL BURNING BETWEEN ROW 6 AND 9. (FLT 5479) REPLACED LOWER ASSEMBLY LIGHT FIXTURE AT 7A.SDR SWIA201229837Skin · corrodedCORROSION ON BOTTOM CENTER FORWARD FUSELAGE SKIN. (SERVICE) REPLACED BOTTOM CENTER FORWARD FUSELAGE SKIN IN REFERENCE TO EMB SRM.
Back to Embraer EMB-120ER