SDR SIMA20181215006Door Sill · corrodedSERVICE DOOR CUTOUT FLOOR CENTER SILL CORRODED. C/A-REPAIRED SERVICE DOOR CUTOUT LOWER CENTER SILL IAW SRM 51-40-02, AND 51-20-03.SDR SIMA20181215004Door Sill · corrodedBAGGAGE DOOR SILL CORRODED. C/A-INSTALLED SERVICABLE CARGO DOOR SILL IAW SRM 52-40-02.SDR SIMA20181214001Flashlight · inoperativeCABIN AFT EMER FLASHLIGHT RED CHARGING LIGHT INOP. REMOVED AND REPLACED FLASHLIGHT AND HOLDER ASSY IAW AMM 33-50-16 NO FIX.SDR SIMA20181214002Battery · dischargedLT AND RT EXTERNAL OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED #4 EMERGENCY BATTERY IAW AMM 33-50-04 AND ETN-EM-33-020R1 OPC GOOD.SDR SIMA20181213001Ecu · failedSUPPLEMENTAL FLAP FAIL EICAS MESSAGE. FLAPS FAILED AT 0 DEGREES ON APPROACH. C/A-CMC FAULT MSG RH FLAP SENSOR FAIL HAD TO RESTORE FCU TO RESET FLAPS IAW FIM 27-51-00-810-817-A STEP 1 ITEM 2. RESTORED FCU BACK TO ORIGINAL CONDITION FOR MEL 27-09. REMOVED AND RESDR SIMA2018121412008Flashlight · inoperativeAFT CABIN FLASHLIGHT NOT WORKING-C/A-REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW EMB 140 AMM 3--50-16 OPC CHECK GOOD NO DEFECTS NOTED AT THIS TIME.SDR SIMA2018121211007Lamp · inoperativeSERVICE DOOR HINGE COVER EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR HINGE COVER EMERGENCY LIGHT LAMP IAW EMB 140 AMM 33-50-09. OPC GOODSDR SIMA20181209010Crossbeam · corrodedISLE CROSS BEAM AT FRAME 25 CORRODED. C/A-COMPLETE: REMOVED AND REPLACED ISLE CROSS BEAM AT FRAME 25 IAW SRM 53-21-10 FIG-1, 10, 10A, 10B, 10C, 10D. ETN-EM-53-139. SEE WIPS AND TASK FOR DETAILS.SDR SIMA20181209009Wire Harness · damagedWIRE BUNDLE BELOW CARGO FLOOR ON LT SIDE BETWEEN FRAMES 65 AND 66 HAS BURN MARKS (TAGGED). C/A-COMPLETE: REPAIRED WIRE BUNDLE BETWEEN FR 65 66 LT IAW SWPM 20-21-00.SDR SIMA20181209008Support Bracket · not reportedTRANSFERRED FROM LOG PAGE 4411161 ITEM 1 "TDMI 831T5346 - REF LOG PAGE 4064237 ITEM 2 - ONETIME REPAIR - POSITION LT WING - WING TO FUSELAGE FAIRING SUPPORT L/H UPPER OVERWING MOUNT BRACKET (PN: 145-72167-001) CRACKED AT RIVET FR-49, MUST BE REPAIRED IAW SRM 5SDR SIMA20181209005Light · damagedRT FLOOR EXTRUSIONS NR 1 AND 2 ARE DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED RT ISLE EXTRUSIONS NR 1, 2 IAW AMM 33-50-12.SDR SIMA20181209006Wire · out of positionEMERGENCY LIGHT STRIP WIRING ROUTED INCORRECTLY AT FLOOR PANEL 231GF. (TAGGED) C/A-COMPLETE:REPAIRED AND REROUTED EMERGENCY LIGHT STRIP WIRING AT 231GF IAW SWPM 20-21-00. SEE BOW310654 FOR OCK.SDR SIMA20181209007Light · dimPAX DOOR EMERGENCY LIGHT DIM. C/A-COMPLETE:REMOVED AND REPLACED PAX DOOR EMERGENCY LIGHT ASSY. IAW AMM 33-50-10.SDR SIMA20181209004Light · damagedEMERGENCY LIGHT EXTRUSIONS ARE DAMAGED NR 1, 2 ,3 AND 8. C/A-COMPLETE:REMOVED AND REPLACED LT ISLE EXTRUSIONS NR 1, 2 ,3 AND 8. IAW AMM 33-50-12.SDR SIMA2018121008003Lamp · inoperativeEXTERNAL EMERGENCY LIGHT ON PAX DOOR INOP-C/A-REMOVED AND REPLACED LAMP FOR EXTERNAL EMERGENCY LIGHT ON PAX DOOR IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA201812107003Thermostat · failedBLEED # 2 OVERTEMP MESSAGE ON EICAS-ON CLIMB OUT 8000 FT.-C/A-FOUND BLD 2 OVTEMP MESSAGE ON EICAS AND PRECOOLER 2 TEMPCTL SYS FAIL ON CMC. T/S PER FIM TASK 36-11-00-810-804-A AND FOUND RH FAN AIR CONTROL THERMOSTAT OPC BAD. REMOVED AND REPLACED RH FAN AIR CONSDR SIMA20181207001Flashlight Assy · shortedFWD FA FLASHLIGHT HOLDER INOP/SHORTED-C/A-DEFERRED FWD FA FLASHLIGHT HOLDER. MEL# 25-53 AUTH# 120247-C. PERFORMED OPC IAW AMM 33-51-01 WITH OTHER FLASHLIGHTS ONBOARD. OPC GOOD. SUSPECTED POSSIBLE INTERMITTENCY WITH FLASHLIGHT HOLDER. RAR FLASHLIGHT AND HOLDER SDR SIMA201812076001Sensor · failedDURNING ICE TEST PNEUMATIC WING A/ICE FAIL CAUTION MESSAGE IN FLIGHT ALL FOUR ANTI ICE LIGHTS WERE ILLUMANATED OPEN NON ICING CONDITION AND ICE DETECTOR OVERRIDE TO ALL. DURING ICE TEST PNEUMATIC BLD 2 LOW TEMP CAUTION MESSAGE IN FLIGHT LEFT TEMP WAS AT TOP OFSDR SIMA201812054002Inverter · inoperativeEMERGENCY LIGHT OVER SERVICE DOOR INOP-C/A-FOUND EMERGENCY LIGHT INVERTER #2 BAD. RAR #2 EMERGENCY LIGHT INVERTER OPS CHECK GOOD IAW EMB AMM 33-50-12SDR SIMA201812054001Seal · fodVERY LOUD SQUEALING AND WOOSHING NOISE COMING FROM MAIN CABIN DOOR AFTER TAKE OFF-C/A-FOUND OBJECT ON DOOR SEAL AND STICKER. REMOVED FROM MAIN CABIN DOOR SEAL AND PERFORMED PRESSURIZATION CHECK IAW 21-31-00. OPS CHECK GOOD NO SQUEELING SOUND NOTED.SDR SIMA201812073008Skin · dentedTRANSFERRED FROM AML 4424546 ITEM 3, FOUND LARGE DENT WITH GAUGE BETWEEN STGR 12R & 14R AND BETWEEN FR 22A & 23. W=4.875IN, L=9.125IN, DEPTH=0.218IN. THIS IS A MAJOR REPAIR-C/A-REPAIRED DENT IAW ERS-EM-53MR-3545SDR SIMA201812073007Stringer · crackedSTR 13R IS CRACKED BETWEEN FR 22A-23.-C/A-REMOVED AND REPLACED STR 13R BETWEEN FR 22A-23 IAW SRM 51-40-02SDR SIMA20181203006Proximity Sensor · failedSPOILER FAIL MSG ON EICAS AND OPN INDICATION WHILE AT GATE AFTER STARTUP. REMOVED AND REPLACED OB RT SIDE PROXIMITY SWITCH IAW AMM 27-63-04. OPC GOOD IAW AMM 27-63-01. NO MESSAGES NOTED.SDR SIMA201812043003Anti-Ice Valve · failedPERFORMING IN AIR ICE TEST, RCVD E2 A/I FAIL. PER QRH CANNOT ENTER ICING CONDITION RTB-LGA-C/A-REMOVED AND REPLACED ENGINE A/I VALVE IAW EMB 140 AMM 30-21-01. OPC DONE IAW EMB 140 AMM 30-00-00 ICE AND RAIN PROTECTION ADJ/TEST. NO DEFECTS NOTED.SDR SIMA201812043002Lamp · inoperativeAFT LH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED AFT LH OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA201812052002Proximity Sensor · shortedNOISE IN FRONT OF NOSE WHEEL COMPARTMENT DUE TO SUSPECTED LACK OF DOOR CLOSURE-C/A-UNABLE FAULT DUE TO INTERNALLY SHORTED NLG DOOR PROX SWITCH. REMOVED AND REPLACED NLG DOOR PROX SWITCH IAW AMM CH32-63-03.SDR SIMA201812031001Uplock · faultedLOUD THUMPING NOISE COMING FROM NOSE SECTION OF AIRCRAFT UNDERNIETH MAYBE IN THE NOSE CONE RADOM. GEAR WAS UP IN THE GEAR WELL."TRANSFERRED TO NRWC 856-LGA-03250"-C/A-SUSPECTED LH AND RH MLG UPLOCK BOXES TO BE FAULTY REMOVED AND REPLACED LH AND RH MLG UPLOCK BSDR SIMA201812031004Light · inoperativeEMERGENCY LIGHT ABOVE FA SEAT FOUND TO BE INOP DURING PS2 CHECK-C/A-REMOVED AND REPLACED PANEL SIGN ASSEMBLY OF FWD EXIT SIGN IAW EMB140 AMM 33-50-14. OPC FAIL. ITEM REQUIRES FURTHER T/S. REMOVED AND REPLACED INVERTER FROM FWD CABIN CLOSET IAW EMB140 AMM 33-5SDR SIMA201812030002Charger · inoperativeLAST 3 EMERGENCY LIGHT STRIPS INOP-C/A-REMOVED AND REPLACED #4 BATT AND CHARGER AND #6 INVERTER IAW EMB 140 AMM 33-50-11 AND W/C 33-700-19. OPS CHK GOOD. INVERTER P/N 7824-1 (6), EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 104958SDR SIMA201812149005A/C Pack · failedAFTER SELECTING PACK 1 ON WE NOTICED A BURNING SMELL AND THEN RECEIVED A PACK 1 OVHT MSG. AFTER RUNNING QRH CHECKLIST PACK 1 WAS BLOWING HOT AIR IN FULL FOLD SETTING IN BOTH MANUAL AND AUTO MODES-C/A-REMOVED AND REPLACED PACK 1 ACM IAW AMM 21-51-03. PERFORMED SDR SIMA201812039003Dau · malfunctionedABORTED TAKEOFF 90 KNOTS DUE TO MASTER WARNING," TAKE OFF TRIM". ALL TRIMS WERE INDICATING GREEN-C/A-REMOVED AND REPLACED DAU#2 IAW EMB 140 AMM 31-41-01. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA201812038006Wheel · out of limitsUPON PS-1 CHECK FOUND # 4 TIRE WORN OUT OF LIMIT-C/A-REMOVED AND REPLACED # 4 TIRE IAW ENVOY MAIN LANDING GEAR WHEEL ASSY REMOVAL AND INSTALLATION W/C 37-700-11. NO FURTHER DEFECTS NOTED.SDR SIMA201811298005Light · inoperativeLH OVERWING LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING LIGHT IAW EMB 140 AMM 33-50-10 OPS CK GOODSDR SIMA201811298003Connector · brokenLAST EMERGENCY FLOOR LIGHT STRIP IN CABIN HAS A BROKEN CONNECTOR-C/A-INSTALLED NEW CONNECTOR FOR EMERGENCY FLOOR LIGHT STRIP IAW EMB SWPM 20-50-00 OPC OF LIGHT STRIP GOODSDR SIMA201811298001Nipple · overheated"TRANSFERRED FROM AML PAGE 4343084 ITEM 1" AFTER APU START AND OPERATING PACK 2 FOR APPROX 3 MINUTES, SMELLED ELETRICAL HEAT/BURNING SMELL WHILE AT THE GATE. F/A REPORTED SMELL BY SEAT 3A FORWARD AND SMELL IN COCKPIT ALSO. NEGATIVE DE-ICE ON ORIGINATION FLIGHTSDR SIMA201811276008Flashlight Assy · brokenFWD FA FLASHLIGHT HOLDER BROKEN-C/A-CREW PLACARDED FWD FA FLASHLIGHT HOLDER MEL 25-53 AUTH# 110865 MOC # 730088. REMOVED AND REPLACED FLASHLIGHT ASSEMBLY AS PER AMM 35-50-16. OPS GOOD. NO FUTER DEFECTS NOTED. MEL RESTOREDSDR SIMA201811276005Display · malfunctionedISIS WENT DARK, THEN RE-APPEARED WITH WHITE "ATT" INSIDE RED BOX. NO ATTITUDE INFORMATION PRESENTED. OTHER INSTRUMENTATION MATCHED PRIMARY DISPLAYS QRH PROC APPLIED, NO EFFECT. EMERGENCY DECLARED.-C/A-ACCOMPLISHED FIM TASK 34-1-00-810-801-A STEPS 1 &3. DISCRESDR SIMA201811276007Warning Message · false activationICE CONDITION ANTI ICE INOP POSTED IN FLIGHT IN ICING CONDITIONS.-C/A-PERFORMED OPS CHECK OF ANTI ICE SYSTEM PER EMB 140 AMM 30-00-00. NO DEFECTS NOTED, NO CMC MSGS POSTED. A/C OKAY FOR SERVICE.SDR SIMA201811276006Acm · failedSMELL OF SOMETHING HEATED ODOR AT GATE PRIOR TO PUSH BACK REPEAT WRITE UP FROM PREVIOUS 2 DAYS-C/A-REMOVED AND REPLACED R/H AIR CYCLE MACHINE IAW AMM 21-51-03. OPS CHECK GOOD IAW AMM 21-51-00. REMOVED AND REPLACED GASPER FAN IAW AMM 21-23-03. OPS CHECK GOODSDR SIMA20181126003Power Supply · inoperativeCABIN EMERG LT IS ON-C/A-UPON THROUBLESHOOTING FOUND BATTERY POWER SUPPLY INOP, REMOVED AND REPLACED BATTERY POWER SUPPLY AND FOR PRECAUTIONARY PURPOSE RAR BATTERY PACK #4 IAW EMB 140 AMM 33-50-04. OPC GOOD NO DEFECTS NOTED AT THIS TIME. EMERGENCY LIGHTING BASDR SIMA20181126002Fan · failedELECTRICAL SMELL NOTED IN THE FRONT OF THE CABIN WHEN WE ARRIVED AT THE GATE-C/A-T/S FOUND RT RECIRCULATION FAN BURN. REMOVED AND REPLACED CABIN RECIRCULATION FAN OPS CK GOOD NO ELECTRICAL SMELL NOTED IAW AMM 21-24-01.SDR SIMA20181126001Flashlight Assy · brokenFWD FA FLASHLIGHT HOLDER BROKEN-C/A-REMOVED AND REPLACED FWD FA FLASHLIGHT ASSY IAW 33 50-16 POS GOOD.SDR SIMA2018112603003Charger · failedDURING PS-1 FOUND RH AND LH OVER WING EMERGENCY LIGHT INOP-C/A-RAR #4 BATTERY POWER SUPPLY IAW EMB 140 AMM 33-50-04. OPC CK GOOD ON BOTH SIDE NO DEFECTS NOTED AT THIS TIMESDR SIMA201811261003Light · inoperativeFOUND EMERGENCY FLOOR PROXIMITY STRIP AT 14A INOP-C/A-RAR FLOOR PROIMITY STRIP LIGHT AT 14A IAW EMB 140 AMM 33-50-12. OPC GOOD.SDR SIMA201811261002Anti-Ice Valve · failedANTI ICE FAIL AND WING ANTI ICE FAIL IN ICING CONDITIONS-C/A-REMOVED AND REPLACED WING 1 A/I VLV IND RELAY K0435 IAW EMB 140 AMM 20-13-02.NO DEFECTS NOTED,REF LOG PAGE 4400635 ITEM 1 FOR OPS CHECKSDR SIMA201811198001Roller · lack of lubeMAIN CABIN DOOR IS HARD TO CLOSE-C/A-PERFORMED THE LUBRICATION OF THE MAIN DOOR FRAME ROLLERS IAW EMB 140 AMM 53-21-02. OPC GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA201811197001Fire Detector · failedE1 FIRE DET FAIL ON EICAS IN CRUISE/DESCENT/LANDING & TAXI IN NO OTHER ADNORMALLITIES NOTED-C/A-REMOVED AND REPLACED LH ENGINE FIRE LOOP DETECTOR IAW EMB 140 AMM 26-11-01 OPS CHECKS GOODSDR SIMA2018112616003Warning Message · false activationMECH BLD 1 OVR TEMP. CAUTION MSG DECLARED EMERGENCY.FLT CXLD.-C/A-REF FIM 36-11-00 NO DISCREPANCIES NOTED AT THIS TIME. NO ASSOCIATED CMC OR EICAS MSGS. PERFORMED OPERATIONAL TEST IAW AMM 36-00-00-700-803-A OPS CHECK GOOD.SDR SIMA201811196002Controller · failedAUTOMATIC PRESSURIZATION SYSTEM FAILED AS WE BEGAN OUR CLIMB.-C/A-RAR CABIN PRESS. CONTROL SYSTEM DIGITAL CONTROLLER IAW AMM 21-31-01. PERFORMED PRESS. CONTROL SYSTEM FUNCTIONAL TEST IN AUTO MODE IAW AMM 21-31-00. OPERATIONAL CHECK GOOD NO FURTHER DEFECTS NOTESDR SIMA20181115001Mechanism · lack of lubeMAIN DOOR HARD TO OPEN. LUBE MAIN PAX DOOR LOCK MECH IAW AMM 52-18-06, OPS CHK GOOD.
Back to Embraer EMB-135KL