SDR SIMA20160514003Smoke Warning · false activationIN CRUISE FLIGHT AT 320 THE BAGGAGE SMOKE WARNING MSG APPEARED MOMENTARILY & THE BAGGAGE EXTINGUISHER LIGHT ILLUMINATED & STAYED ON REST OF FLIGHT. PERFORMED SEVERAL TEST OF BAGGAGE SMOKE DETECTION SYS IAW AMM 26-15-00. OPERATIONS CHECKED GOOD. PERFORMED A SDR SIMA20160511001Case · chafedRIGHT OVERWING PANEL EMER LIGHT ASSEMBLY INTERIOR CASE IS CHAFED. R & R RT OVERWING PANEL EMER LIGHT ASSEMBLY IAW AMM 33-50-10.SDR SIMA20160510004Unknown · malfunctionedAFTER TAKEOFF IN WX, BOTH RADARS WOULD NOT DISPLAY PROPERLY. PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM IAW AMM 34-42-00. NO DEFECTS FOUND. OPERATIONS CHECKED GOOD. PERFORMED OVERWEIGHT LANDING INSPECTION IAW WC 05-200-01. NO DEFECTS NOTED. ACFT SDR SIMA20160510001Flashlight · brokenFIRST OFFICER EMER FLASHLIGHT CRADLE IS BROKEN. R & R FIRST OFFICERS EMER FLASHLIGHT CRADLE. CHECKED OK IAW AMM 33-50-16.SDR SIMA20160506004Wire · brokenLT EMERGENCY LIGHT STRIP NR 1 IS BROKEN. REPAIRED BROKEN WIRE ON LT EMERGENCY LIGHT STRIP NR 1 IAW SWPM 20-21-00. BOW218817 FOR OPC.SDR SIMA20160506005Light · brokenLT EMERGENCY LIGHT STRIP NR 2 AND NR 7 ARE BROKEN. R&R LT EMERGENCY LIGHT STRIP NR 2 AND NR7 IAW AMM 33-50-12. BOW218817 FOR OPC.SDR SIMA20160503001Frame · crackedFRAME 23 CRACKED BETWEEN STRINGERS 15R - 16R. REPAIRED FRAME 23 IAW EM-53MR-1808.SDR SIMA20160427001Hydraulic Line · not reportedDURING FLIGHTS NOTICED HYD 1 LO QTY, AFTER LG EXTENSION, 3 DOWN, GOT ENG 1 HYD PUMP FAIL. COMPLIED WITH CHECKLIST. TRANSFERRED TO NRWC 809-DFW-02349. R & R LT MLG ACTUATOR EXT HOSE AMM 32-33-08. SEE ITEM 3 FOR GEAR EXTENSION & RETRACTION & LEAK CHECK. REFSDR SIMA20160425003Frame · corrodedFRAME 65 IS CORRODED UNDER FWD LOWER CARGO DOOR GUIDE PLATE. REPAIRED FRAME 65 UNDER FWD LOWER CARGO DOOR GUIDE PLATE IAW SRM 53-31-04 ITEM 4E FIG 212.SDR SIMA20160422003Connector · missingFLOOR EMER LIGHT STRIP WIRE AT FRAME 57 IS MISSING CONNECTOR. REPLACED MISSING CONNECTOR AT FLOOR EMER LIGHT STRIP WIRE AT FRAME 57 IAW SWPM 20-00-03 & 20-21-00.SDR SIMA20160421004Hinge Fitting · corrodedLEFT ELEVATOR SERVO TAB INBD HINGE FITTING CORRODED AT BONDING WIRE ATTACHMENT. R & R LT ELEVATOR SERVO TAB INBD HINGE FITTING IAW AMM 55-22-01, SRM 51-20-03 & CPM 51-21-04. SN 2149. SEE BOW 216840 FOR INSTALLATION OF BOLT WITH BONDING JUMPER.SDR SIMA20160418005Skin · crackedRIGHT AFT FUSELAGE FRAME 75 FASTENER AT STRINGER 2 AREA SKIN CRACKED. PERFORMED CUT OUT AS REQUIRED TO REMOVE DAMAGE FROM FUSELAGE EXTERNAL SKIN AT FRAME 75, STRINGER 2R AREA, FABRICATED & INSTALLED FILLER, DOUBLER, SHIM & DRAG ANGLE REINFORCEMENT IAW ERS-EM-SDR SIMA20160418002Repair · corrodedFRAME 68 SHEAR CLIP PREVIOUS REPAIR CORRODED AT LOWER CARGO DOOR CUT OUT. REPAIRED FRAME 68 SHEAR CLIP AT PREVIOUS REPAIR IAW SRM 53-31-04.SDR SIMA20160418003Repair · corrodedFRAME 65 SHEAR CLIP PREVIOUS REPAIR CORRODED AT LOWER CARGO DOOR CUT OUT. REPAIRED FRAME 65 SHEAR CLIP AT PREVIOUS REPAIR IAW SRM 53-31-04.SDR SIMA20160416001Inverter · inoperativeEMERGENCY LIGHTS IN ROW 7 - 10 & LOWER EMER LIGHTS ON EMER EXIT DOORS INOPERATIVE. TROUBLE SHOT IAW FIM 33-50-00 FOUND INVERTER 5 TO BE INOPERATIVE. R & R INVERTER 5 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20160402001Lever · defectiveON ROLL OUT AT 80KTS, RECEIVED ADVISORY CARGO DOOR OPEN. TAKEOFF ABORTED. RETURNED TO GATE. GND PERSONNEL REVISED DOOR. DOOR INDICATION ON MFD FLICKERING GREEN TO RED & EICAS MSG KEPT DISPLAYING. VERIFIED BAG DOOR CLOSES & LATCHES FLUSH AS REQUIRED IAW MESDR SIMA20160331010Skin · crackedLEFT UPPER FUSELAGE SKIN CRACKED IN 2 PLACES. CRACK 1 IS JUST AFT OF FRAME 75 & ABOVE STRINGER 2L. CRACK IS APPROX 3/8" LONG. CRACK 2 IS AT THE FIRST FASTENER AFT OF FRAME 75 ON STRINGER 2L, CRACK IS APPROX 1/4". FABRICATED & INSTALLED REPAIR PARTS FOR LT SDR SIMA20160331009Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED AT FIRST FASTENER, BELOW STRINGER 2R. CRACK IS APPROX 3/8" LONG. PERFORMED REPAIR OF RT UPPER FUSELAGE SKIN CRACKS IAW ERS-EM-53MR-2072.SDR SIMA20160329002Wire · brokenEMERGENCY LIGHT STRIP WIRE BROKEN UNDER FLOOR PANEL 251GF. REPAIRED EMER LIGHT STRIP WIRE UNDER FLOOR PANEL 251GF IAW SWPM 20-21-00 & 20-50-01. SEE NRTC BOW 216053 FOR OPERATIONS CHECK. SEE TASK & WIP ENTRIES FOR DETAILS.SDR SIMA20160328009Skin · crackedAFT FUSELAGE RT SIDE FRAME 75 HAS POSSIBLE CRACK AT ONE FASTENER. COMPLIED WITH ERS-EM-53MR-2059 RT RFI SKIN CRACKED AT FRAME 75, BETWEEN STRINGER 2R - 3R REPAIR.SDR SIMA20160328011Support · crackedRIGHT OMEGA BEAM INBD & OTBD SUPPORTS ARE CRACKED AT FRAME 47. REMOVED CRACKED RT OMEGA BEAM INBD & OTBD SUPPORTS AT FRAME 45 - 52 & INSTALLED SERVICEABLE RT OMEGA BEAM INBD & OTBD SUPPORTS IAW SRM 51-40-02 & 53-23-02.SDR SIMA20160328010Support · crackedLEFT OMEGA BEAM OTBD SUPPORT IS CRACKED AT FRAME 47. REMOVED CRACKED LT OMEGA BEAM OTBD SUPPORT, BETWEEN FRAME 45 - 50 & INSTALLED LT OMEGA BEAM OTBD SUPPORT IAW SRM 51-40-02.SDR SIMA20160328008Contactor · defectiveFLASHLIGHT AT THE LAVATORY IS NOT SHOWING IT IS CHARGING, THE LED DOES NOT COME ON. R & R CONTACTORS TO WIRES W775-0005-24RD SP3557 & W775-0006-24BK SP3558 FOR FLASHLIGHT AT THE LAVATORY IAW SWPM 20-50-01 & 20-00-03. SYS CHECKED GOOD IAW AMM 33-50-16 STEP 3 SDR SIMA20160328006Case · chafedRIGHT OVERWING PANEL EMER LIGHT ASSEMBLY INTERIOR CASE IS CHAFED. R & R RT OVERWING PANEL EMER LIGHT ASSEMBLY INTERIOR CASE IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20160328005Power Supply · inoperativeRIGHT OVERWING PANEL EMER LIGHT INOPERATIVE. R & R NR 4 EMER SYS POWER SUPPLY IAW WC 33-700-19. FUNCTIONAL CHECKED GOOD. EMER LIGHTING BATTERY PN 2013-1A.SDR SIMA20160328004Wire · brokenNUMBER 2 LT FLOOR EMER LIGHT STRIP WIRE BROKEN. R & R NR 2 LT FLOOR EMER LIGHT STRIP IAW AMM 33-50-12. SEE BOW 216337 FOR INSTALLATION OF PROXIMITY LIGHTS.SDR SIMA20160328003Strip · crackedNUMBER 8 LT FLOOR SIDEWALL STRIP CRACKED. R & R NR 8 LT FLOOR SIDEWALL STRIP IAW AMM 33-50-12. SEE BOW 216337 FOR INSTALLATION OF PROXIMITY LIGHTS.SDR SIMA20160323002Connector · brokenFLOOR PROXIMITY STRIP LIGHT AT FLOORBOARD 251JF HAS A BROKEN CONNECTOR. REPAIRED FLOOR PROXIMITY STRIP LIGHT IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.SDR SIMA20160312003Battery · dischargedPER PS 1 INSPECTION FOUND EXTERNAL EMER LIGHT INOPERATIVE. REPLACE BATTERY & CHARGER IAW 33-50-04. BATTERY CHARGER ASSEMBLY PN 11-0049 & SN 15742.SDR SIMA20160312001Electronic Unit · failedDURING CLIMB OUT LG FAILED TO RETRACT, WE RUN AOM 1 PROCEDURE & RETRACTED LG. MOC ADVISED US TO RETURN. LG WORKED OK FOR THE REST OF THE FLIGHT. LG & LEVER DISAGREE MSG WAS PRESENTED DURING FAILED RETRACTION. MSG DISAPPEARED AFTER WE CYCLED GEAR. REPLACEDSDR SIMA20160210007Pump · failedHYD LO QTY ADVISORY NR 1 HYD SYS IS IN AMBER, NO RECOVERY & CONTINUED TO DROP. NO INDICATION OF HYD LEAK ON POST FLIGHT. R & R NR 1 EDP IAW AMM CH 29-10-03. OPERATIONS & LEAK CHECKED GOOD.SDR SIMA20160226003Inverter · inoperativeSECOND & THIRD EMER FLOOR STRIP LIGHTING INOPERATIVE. R & R NR 3 EMER LIGHT INVERTER IAW 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20160221002Controller · failedAUTO PRESSURIZATION CONTROLLER FAILED, HAD TO MANUALLY CONTROL THE PRESSURIZATION. R & R AUTO PRESSURIZATION DIGITAL CONTROLLER IAW AMM 21-31-01. OPERATIONS CHECKED GOOD.SDR SIMA20160211003Smoke Detector · failedBAGGAGE COMPARTMENT SMOKE DETECTOR FAILS FIRE TEST. R & R BAGGAGE COMPARTMENT FWD SMOKE DETECTOR IAW AMM 26-15-01. OPERATIONAL CHECKED GOOD.SDR SIMA20160204003Light · inoperativeOVERHEAD EMER LIGHT IN COCKPIT INOPERATIVE. R & R BULB IN OVERHEAD EMER LIGHT IN COCKPIT IAW AMM 33-50-05. OPERATIONS CHECKED GOOD.SDR SIMA20160203003Holder · brokenFIRST OFFICERS FLASHLIGHT HOLDER BROKEN. DEFERRED IAW MEL 25-53. R & R FIRST OFFICERS FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONAL CHECK GOOD & MEL RESTORED.SDR SIMA20160125003Light · inoperativeSERVICE DOOR CEILING EMER LIGHT INOPERATIVE. REMOVED & INSTALLED SERVICEABLE SERVICE DOOR CEILING EMER LIGHT LAMP IAW AMM 33-50-09. OPERATIONAL CHECKED GOOD.SDR SIMA20160125001Ahrs · failedIC-600 1 FAILED INFLIGHT. NO IC-600 BUS FAIL EICAS MSG, BUT CAPTAIN'S PFD & MFD HAD RED X'S. SELECTED SG ON REVERSIONARY PANEL & BOTH PFD & MFD WENT BLANK. AHRS 1 FAILED INFLIGHT. SPS ADVANCED CAUTION MSG INFLIGHT. AUTO PILOT FAILED INFLIGHT. YAW DAMPENESDR SIMA20160120002Display · failedSTRONG ELEC ODOR IN COCKPIT. REPLACED CAPTAINS MFD IAW AMM 34-22-01. OPERATIONS CHECKED GOOD.SDR SIMA20160118003Light · inoperativeLEFT OVERWING EMER LIGHT INOPERATIVE. R & R LT OVERWING EMER LIGHT LAMP IAW AMM 33-50-07. OPERATIONS CHECKED GOOD.SDR SIMA20160108005Battery · discharged1ST CEILING LIGHT IN CABIN INOPERATIVE. R & R NR 1 BATTERY POWER SUPPLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20160105005Switch · failedON CLIMBING, ENTERING ICE CONDITION, GOT 4 OPEN BUT GOT BLD 1 VLV FAIL & BLD CLOSED WHEN ICING TURNED OFF. FAIL MSG ADV CLEARED ON DESCENT, IN ICING GOT BLD1 FAIL BUT NO BLD CLOSED ADVS ON THE GND, WE DESELECTED BLD 1 CLOSED BUT GOT NO CLOSED MSG OR FAIL. R SDR SIMA20160105002Inverter · inoperativeAFT 3 EMER FLOOR PROXIMITY LIGHTS INOPERATIVE. R & R NR 6 EMER LIGHT INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20151230001Holder · brokenCAPTAINS FLASHLIGHT HOLDER BROKEN. R & R CAPTAINS FLASHLIGHT ASSEMBLY IAW AMM 33-50-16.SDR SIMA20151229002Filter · dirtyBLEED 1 OVERTEMP INFLIGHT. VISUALLY INSPECTED FAN AIR VLV LINES, NO DAMAGE FOUND. FOUND CLEAN FAN AIR VLV FILTER IAW AMM 36-11-03. PERFORMED OPERATIONS CHECK IAW AMM 36-00-00, DID NOT FIX REF ITEM 3. R & R FAN AIR VLV IAW AMM 36-11-03. OPERATIONS CHECKED SDR SIMA20151228001Fire Loop · chafedMOMENTARY APU FIRE INDICATION. PERFORMED GVI AROUND APU, NO DEFECTS FOUND. DEFERRED APU, M PROCEDURES COMPLIED WITH IAW 49-1. FOUND APU FIRELOOP CHAFFING AGAINST HOT SPOT ON ENGINE. REMOVED AND REPLACED APU FIRELOOP IAW AMM 26-12-01. OPS CXK GOOD. MEL 49SDR SIMA20151221001Flashlight Assy · brokenWHILE TROUBLESHOOTING FLASHLIGHT PIREP, FOUND CAPTAIN'S FLASHLIGHT CRADLE BROKEN. R & R HOLDER IAW AMM 33-50-16.SDR SIMA20151221002Lamp · inoperativeCAPTAINS FLASHLIGHT WILL NOT CHARGE. TRIED 2 DIFFERENT HOLDERS. FOUND FLASHLIGHT BULB ASSEMBLY DAMAGED. R & R LAMP ASSEMBLY IAW CMM 25-60-02. OPERATIONS CHECKED GOOD.SDR SIMA20151220001Spoiler Sys · malfunctionedON DECENT WHILE USING SPOILERS TO ASSIST THE DECENT, ONCE THE SPOILERS HANDLE WAS RETURNED TO STOWED POSITION, EICAS MSG SPOILER FAIL WITH SPOILERS INDICATION ON OPEN. FOLLOWED EPC EMERGENCY PROCEDURES. PERFORMED SPOILER & SPEED BRAKE SYS. OPERATIONS GOOD &SDR SIMA20151215001Hydraulic Line · damagedRAMP PERSONNEL INDICATE SUSPICIOUS ODOR IN THE CARGO COMPARTMENT. TRANSFERRED TO NRWC 833-DFW-02181. PERFORMED PERMANENT REPAIR TO RUDDER PRESS LINE AT LAVATORY & CARGO BULKHEAD IAW AMM 20-10-03. SEE NRWC 833-DFW-02181 FOR MORE INFO. CONFIRMED DAMAGED RUDD
Back to Embraer EMB-135KL