Embraer EMB-135KL
Service difficulty reports · 5,598
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB135KL' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB135KL' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA2019112019004Control Handle · lack of lubePARKING BRAKE HARD TO RELEASE-C/A-LUBRICATED EMERGENCY PARKING BRAKE CONTROL IAW ENVOY WIC 32-600-12. OPC GOOD AT THIS TIME. NO DEFECTS NOTED.SDR SIMA2019112019002Battery Pack · inoperativePER PS-1 INSPECTION, FOUND RH AND LH OVER THE WING EMERGENCY LIGHTS INOP-C/A-REMOVED AND REPLACED #4 EMERGENCY LIGHT BATTERY AND CHARGER IAW EMB AMM 33-50-04. OPC BAD. BATTERY CHARGER ASSY P/N 11-0049 S/N 25338; LIGHT EMERGENCY L/H P/N 30-2510-3SDR SIMA201911198003Light · inoperativeGALLEY DOOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED GALLEY DOOR EMERGENCY LIGHT IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD END.SDR SIMA201911187004Bearing · lack of lubeMAIN DOOR WONT CLOSE-C/A-LUBRICATED MAIN DOOR ROLLER BEARINGS IAW EMB 140 AMM 53-21-02. NO FURTHER DEFECTS NOTED AT THIS TIME. OPC OF DOORGOOD.SDR SIMA201911186003Door · lack of lubeMAIN PAX FOOR GETS JAMMED AFTER CLOSING MAKING IT VERY DIFFICULT TO OPEN IT-C/A-LUBRICATED MAIN DOOR IAW EMB 140 AMM 52-11-00. NO FURTHER DEFECTS NOTED. OPC GOOD.SDR SIMA201911186001Light · inoperativeL/H OVERWING EMERGENCY LIGHT INOP-C/A-RAR LEFT OVERWING EMERGENCY LIGHT ASSY OPC GOOD AMM 33-50-01SDR SIMA201911185003Bulb · inoperativeSERVICE DOOR HINGE COVER EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR HINGE COVER EMERGENCY LIGHT BULB IAW EMB 140 AMM 33-50-10 2. K (1) (2) (3) AND 3. J (1) (2) (3). OPS CHECK GOOD.SDR SIMA201911185002Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM TASK 33-50-07-000-801-A AND 33-50-07-400-801-A OPC GOOD.SDR SIMA201911154002Flashlight · missingON POST FLIGHT REAR F/A FLASH LIGHT MISSING-C/A-INSTALLED NEW FLASH LIGHT AT REAR CABIN IN REF TO E140 AMM 33-50-16. OPC GOODSDR SIMA201911154001Roller · lack of lubeMAIN CABIN DOOR VERY DIFFICULT TO OPEN. FA WAS UNABLE TO OPEN. FO OPENED DOOR-C/A-LUBRICATED MAIN CABIN DOOR ROLLERS IAW EMB 140 AMM 53-21-02-600-801-A STEP 2J3SDR SIMA201911213011Pump · failedLO HYD 1 LO QTY DURING FLT IT DROPPED TO BOTTOM OF LEVEL AND GND OPS REPORT LEAKING FROMUNDER # 1 ENGINE FLUID-C/A-FOUND E1 LOWER COWLING WITH HYD FLUID COMING FROM EDAP REMOVED AND REPLACED E1 EDHP PER EMB AMM 29-10-*03 OPC AND LEAK CK GOOD SVCED HYD # 1 PER SDR SIMA201911143007Light · inoperativeOVERHEAD COCKPIT EMER LIGHT INOP-C/A-REMOVED AND REPLACED OVERHEAD COCKPIT EMER LIGHT IAW AMM 33-50-05. OPS CHECK GOODSDR SIMA201911143003Door · bindingMAIN CABIN DOOR VERY DIFFICULT FOR FA TO OPEN & CLOSE.-C/A-PERFORMED GVI OF DOOR AND SEALS. PERFORMED OPS CK OF OPEN & CLOSE FUNCTION OF DOOR IAW EMB 145MM 52-10-01. OPS CK GOOD.SDR SIMA201911143008Pump · failedLO HYD 1 LO QTY DURING FLT IT DROPPED TO BOTTOM OF LEVEL AND GND OPS REPORT LEAKING FROMUNDER # 1 ENGINE FLUID-C/A-FOUND E1 LOWER COWLING WITH HYD FLUID COMING FROM EDAP REMOVED AND REPLACED E1 EDHP PER EMB AMM 29-10-*03 OPC AND LEAK CK GOOD SVCED HYD # 1 PER SDR SIMA201911143004Lamp · inoperativeR/H WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED R/H WING EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA201911132001Handset · odorUPON LANDING FA REPORTED A BURNING SMELL IN GALLEY AREA-C/A-PERFORMED FIM TASK 21-20-00-810-801-A- FOUND FWD FA HAND MIC TO HAVE AN ELECTRICAL BURNT SMELL.CHECKED GENERAL CONDITION OF PLUG NO DEFECTS NOTED REMOVED AND REPLACED FWD FA HAND MIC IAW AMM 23-31-03SDR SIMA201911132002Regulator Valve · failedDURING CLIMB OUT PERFORMED ICE TEST. WE SAW WG A/ICE FAIL, STAB A/ICE FAIL, BLD 1 VLV FAIL, AND BLD 1 VLV CLOSED MESSAGES ON EICAS. "TRANSFERRED TO NRWC 808-DFW-03494"-C/A-REMOVED AND REPLACED ENGINE #1 BLEED VALVE IAW AMM 36-11-05.PERFORMED OPC IAW AMM 36-11-SDR SIMA201911131004Anti-Ice System · malfunctionedWING A/I FAIL WHILE IN ICING CONDITIONS IN FLIGHT-C/A-PERFORMED A/ICE SYST OPC IAW AMM 30-00-00,FOUND NO LEAKS IN LINES AND CMC FLAGS NO A/ICE SYST.MSGS.OPC GOOD AMM 30-00-00,NO OTHER FAULTS NOTED.SDR SIMA201911121003Flashlight · unknownAFT FA FLASH LIGHT INOP-C/A-FLT CREW PLACARD AFT FA FLASH LIGHT IAW MEL 2553 AUTH # 110372-C MOC # 624980. OPS CHECKED AFT FA FLASHLIGHT. OPS CHECKED GOOD. IAW CMM 25-60-14 MEL RESTOREDSDR SIMA201911121002Bulb · inoperativeBOTH LH AND RH EXTERNAL AFT EMERGENCY LIGHTS INOP-C/A-RAR BOTH LH AND RH EXTERNAL AFT EMERGENCY LIGHTS BULBS IAW EMB AMM 33--50-10-000-801-A AND 33-50-10-400-801-A NO FIX FURTHER T/S PER WM 33-50-50 RAR #4 EMERGENCY BATTERY AND CHARGER IAW W/C 33-700-19 SDR SIMA201911110007Light · inoperativeCOCKPIT EMERGENCY LIGHT INOP-C/A-RAR COCKPIT EMERGENCY LIGHT IAW AMM TASK 33-50-05-000-801-A AND 33-50-05-400-801-A. OPC GOOD. END.SDR SIMA201911110002Lamp · inoperativeSERVICE-DOOR EMERGENCY LIGHT INOP-C/A-SERVICE-DOOR EMERGENCY LIGHT LAMP RAR IAW EMB140 AMM 33-50-09. OPC GOOD.SDR SIMA2019111109004Warning Message · false activationAFTER TAKE OFF "BAGGAGE DOOR" LIGHT ILLUMINATED RETURNED TO DFW "BAGGAGE DOOR LIGHT" TURNED OFF AFTER LANDING-C/A-DEFFERED BAGGAGE DOOR INDICATION PER MEL 52-5. CLEANED BAGGAGE DOOR WARNING MICROSWITCHES AND PERFORMED OPS TEST IAW EMB 140 AMM 52-76-01. OPS TESDR SIMA2019111109001Flashlight · missingMEL 2553 - AUTH# 11-252-CREF ORG LG PG 4500501/1 PAX STOLE AFT CABIN FLASHLIGHT-C/A-INSTALLED NEW FLASHLIGHT IAW EMB140 AMM 33-50-16. OPS CHECK GOOD. MEL RESTOREDSDR SIMA2019111109003Seal · leakingFA REPORTED MAIN DOOR WAS SQUILING, BEGAN AROUND FL20 DURING PRESSURIZATION/LEAK CHECK OF AIRCRAFT FOUND SERVICE DOOR HAS A LEAK ON BOTTOM FORWARD CORNER-C/A-REPAIRED SERVICE DOOR FRAME SEAL AT FWD LOWER CORNER IAW EMB 140 AMM 53-21-11 SEE NRWC 831-DFW-03891 ISDR SIMA2019111108003Acm · odorMEL 21-30 AUTH 110241D-C ON TAXI OUT, BOTH PACKS RUNNING, CABIN AND COCKPIT FILLED WITH STRONG SMELL OF SMOKE. TURNED OFF PACK #1 AND SMELL WENT AWAY.REF LOG PAGE 4599679 ITEM 2. PACK 1 ACM REQ REPLACEMENT AND PERFORM ETN-EM-21-062.-C/A-RAR LH ACM IAW EO-EM-SDR SIMA2019111108002Lamp · inoperativeEMERGENCY EXIT CEILING LIGHT AT ROW 6/7 IS INOP-C/A-RAR EMERGENCY EXIT CEILING LAMP AT ROW 6/7 IAW EMB 140 AMM 33-50-08. OPS CHECK GOOD.SDR SIMA20191108001A/C Pack · smokeON TAXI OUT BOTH PACKS RUNING CABIN AND COCKPIT FILLED WITH STRONG SMELL OF SMOKE TURNED OFF PACK 1 AND SMELL WENT AWAY-C/A-C/W EMB-140 FIM TASK 21-20-00-810-801-A AIR CONDITION ABNORMAL SMELL NO SMELLS NOTED. C/W ETN-EM-72-034 NO SMELLS NOTED . PERFORMED GVI SDR SIMA201911087001Flashlight · inoperativeAFT FA FLASHLIGHT INOP-C/A-FLIGHT CREW PLACARDED AFT FA FLASHLIGHT MEL 25-53 AUTH 110212-C MOC 056048. REMOVED AND REPLACED AFT FA FLASHLIGHT IAW AMM 33-50-16 OPC GOOD MEL ITEM RESTOREDSDR SIMA201911087003Connector · damagedDURING PS-1 CHECK INSPECTION FOUND EMERGENCY FLOOR PROXIMITY STRIP LIGHT INOP-C/A-REPAIRED ELECTRICAL CONNECTOR AT AFT EMERGENCY FLOOR LIGHT STRIP PER SWPM 20-50-00 OPS CHECK GOODSDR SIMA20191107002Anti-Ice Valve · failedWG A/ICE FAIL ON DESCENT IN ICING CONDITIONS, QRH COMPLIED WITH, MESSAGE WENT AWAY-C/A-REMOVED AND REPLACED WING A/ICE VALVE 2. IAW AMM 30-11-01. NO DEFECTS NOTED. HIGH PWR RUN REQ'D. PERFORMED HIGH POWER RUN FOR WING 2 ANT ICE VALVE OPC. GOOD IAW EMB 14SDR SIMA201911086002Relay · malfunctionedCLIMBING THROUGH FL 190 WHEN BEGAN TO ACCUMLATE ICE AND THE FOLLOWING MSG; ICE COND- A/I INOP, STAB A/ICE FAIL, BLD 1 VLV FAIL, BLD 1 VLV CLSD, WG A/ICE FAIL, AND SPB/ ICE SPEED.-C/A-OHM BLEED 1 PUSH BUTTON SWITCH,SWITCH IS GOOD. REMOVED AND REPLACED RELAY RO SDR SIMA20191105001Power Supply · failedEMERG LT COME OM WHEN YOU UNARM IT TO OFF-C/A-REMOVED AND REPLACED BATTERY POWER SUPPLY 4 IAW ERJ140 AMM 33-50-04. NO FURTHER DEFECTS NOTEDSDR SIMA20191105002Charger · failedBOTH OVERWING EXTERNAL AFT EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED BULBS IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A NO FIX, T/S PER WM 33-50-50 SLAVED IN INVERTER IAW EMB AMM 33-50-11-400-801-A NO FIX, T/S FURTHER RAR #4 EMERGENCT BATTERY AND SDR SIMA20191104003Light · inoperativeLH SIDE CENTER FAIRING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH CENTER FAIRING EMERGENCY LIGHT IAW AMM 33-50-10 OPS CHK GOODSDR SIMA20191103002Flashlight · inoperativeFA FWD FLASH LIGHT INOP-C/A-FLIGHT CREW PLACARDED PER MEL2553 AUTH110094C MOC 135181. REMOVED AND REPLACED F/A FORWARD FLASH LIGHT ASSEMBLY AS PER EMER.EQUIP.LIST[EEL].OPC. GOOD.MEL RESTORED.SDR SIMA20191101001Power Supply · failedEMERGENCY LIGHTING BATTERY ASSY/ BATTERY CHARGER REPLACEMENT REQUIRED FOR BATTERY POWER SUPPLY #3-C/A-REMOVED AND REPLACED BATTERY POWER SUPPLY #3 IAW ENVOY W/C 33-700-19. OPC GOOD IAW ENVOY W/C 33-700-17. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 83000SDR SIMA20191031005Warning System · false activationPACK 1 OVERHEAT IN CRUISE BURNING SMELL RIGHT BEFORE CATION MESSAGE-C/A-FOUND PACK 1 SWITCH IN MANUAL MODE AND IN FULL HOT POSITION. PERFORMED PACK DUCT INSP. IAW AMM 21-51-14. PERFORMED GVI ACM INLET IAW AMM 21-51-00 NO DEFECTS NOTED PERFORMED OPS CHECK IAW ASDR SIMA20191031006Charger · failedDURING OPS CHECK OF EMERGENCY LIGHTING SYSTEM FOUND LIGHTS ASSOCIATED WITH EMERGENCY BATTERY # 2 INOP-C/A-UPON INSPECTION FOUND # 2 EMERGENCY LIGHTING BATTERY NOT CONNECTED. REMOVED AND INSTALLED NEW BATTERY AND CHARGER IAW W/C 33-700-19. OPS CHECKS GOOD IAW SDR SIMA201910310003Bleed Valve · failedPACK VALVE AND BLD VALVE CLOSED INFLIGHT ON #2. PACK 2 VALVE C/B POPPED.-C/A-REMOVED AND REPLACED #2 PACK VALVE IAW AMM 21-51-01. OPERATIONAL CHECK GOOD. #2 BLD VALVE OPS CHECK GOOD IAW AMM 36-11-05.SDR SIMA201910310004Light · inoperativeMAIN PAX DOOR UPPER EMERGENCY EXIT LIGHT INOP.-C/A-REMOVED AND REPLACED PAX DOOR EXIT MARKER IAW EMB 140 AMM 33-50-13. OPS CHECK GOOD IAW EMB 140 AMM 33-50-00.SDR SIMA2019103029002Connector · brokenEMERGENCY LIGHT 3RD FLOOR STRIP REMOVABLE SPLICE CONNECTION BROKEN-C/A-INSTALLED A NEW DISCONNECTABLE SPLICE AT EMERGENCY LIGHT 3RD STRIP IAW SWPM 20-21-00. OPT OF FLOOR PROXIMITY STRIP LIGHTS GOOD IAW AMM 33-50-00.SDR SIMA201910298003Acm · seizedSUPPLEMENTAL PACK 1 OVHT DISPLAYED ON EICAS. MESSAGE FOLLOWED AFTER STRANGE SMELL COMING IN COCKPIT WHILE PACKS ON.-C/A-DEFERRED #1 PACK,PERFORMED GVI OF #1 PACK AND CONFIRMED IS SEIZED UP (NOT COMING ON) CAUSING THE HOT AIR SMELL REPORTED BY CREW. PREVIOUS TRSDR SIMA201910298001Charger · failedBOTH OVERWING EMERGENCY LIGHTS INOP-C/A--REMOVED AND REPLACED BOTH OVERWING EMERGENCY LIGHTS IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. TROUBLESHOT, SUSPECTED EMERGENCY BATTERY. REMOVED AND REPLACED EPSU AT THE #3 AND #4 POSITION IAW 33-700SDR SIMA201910287002Fan · failedELECTRICAL SMELL IN FLIGHT DECK "TRANSFERRED TO NRWC 810-DFW-02773"-C/A-REMOVED AND REPLACED # 2 FWD ELECK COMPT COOLING FAN IAW AMM 21-26-02. OPCK GOOD. PERFORMED FIM TASK 21-20-00-810-801-A , TO COMPLETION. NO SMELL AT THIS TIME.SDR SIMA201910286002Brake · unknownPARKING BRAKE IS NOT WORKING PROPERLY. DIFFICULTY SETTING IT-C/A-PERFORMED OPC OF PARKING EMERGENCY BRAKE IAW EMB 140 AMM 32-44-00. OPC GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA201910285003Bulb · inoperativeL/H CENTER FAIRING EXT EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED L/H CENTER FAIRING EXT EMERGENCY LIGHT BULB IAW EMB I45 AMM 33-50-10 OPS CHECK GOOD NO FURTHER DEFECTS NOTEDSDR SIMA201910254002Charger · inoperativeFOUND FWD EMERGENCY BATT #2 LIGHTS INOP-C/A-REMOVED AND REPLACED #2 EMERGENCY LIGHT BATTERY AND CRADLE ASSY IAW WC 33-700-19 AND W/C 33-700-17 OPS CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 104519SDR SIMA201910254001Warning Message · false activationIN ICING CONDITIONS RECIEVED WING ANTI ICE FAIL FOLLOWED BY A/I INOP WEARNING. RAN QRH PROCEDURE WORKED FOR 1 MINUTE THEN FAILED AGAIN-C/A-CMC FAULT CODE 30-1PM83. TROUBLESHOOT IAW EMB 145 FIM 30-11-00-810-809A BLOCKS 1 AND 8. NO FAULTS OPS CHECKS GOOD.SDR SIMA201910243005Flashlight · inoperativeSUPPLEMENTAL AFT CABIN FLASH LIGHT INOP. CHARGING BASE NOT WORKING.-C/A-ITEM DEFERRED PER MEL 25-53 AUTH# 100787-C. REMOVED AND REPLACED AFT CABIN FLASH LIGHT PER EMER.EQUIPMENT LIST[ EEL] . MEL RESTORED.
Back to Embraer EMB-135KL