What was found
UPON LANDING FA REPORTED A BURNING SMELL IN GALLEY AREA-C/A-PERFORMED FIM TASK 21-20-00-810-801-A- FOUND FWD FA HAND MIC TO HAVE AN ELECTRICAL BURNT SMELL.CHECKED GENERAL CONDITION OF PLUG NO DEFECTS NOTED REMOVED AND REPLACED FWD FA HAND MIC IAW AMM 23-31-03. OPS CHECK GOOD.