Embraer EMB-145EP
Service difficulty reports · 2,197
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145EP' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145EP' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA20140702173Floor Support · corrodedDURING C-CHECK, RAMP ANGLE ON CENTER OMEGA BEAM AT FRAME 20 HAS CORROSION, 100 PERCENT THROUGH. MAINTENANCE R & R RAMP ANGLE AT FRAME 20 CENTER FLOOR SUPPORT IAW IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702172Attach Angle · crackedDURING C-CHECK, SEVERAL CRACKS IN ATTACH FLANGE FOR PANEL ON LT UPPER INBD WING SKIN BETWEEN FRAMES 40-41. MAINTENANCE REMOVED DAMAGED PORTION, FABRICATED NEW ANGLE AND INSTALLED BETWEEN FRAMES 40-40 IAW SRM 51-40-02 AND EC5720-01079. THE ACFT WAS APPROVED FSDR ASOA20140702171Shear Tie · crackedDURING C-CHECK, SHEAR TIE AT FRAME 73 BETWEEN STRINGERS 7 - 8R FOUND CRACKED. MAINTENANCE R & R SHEAR TIE IAW SRM 53-31-04. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702170Skin · crackedDURING C-CHECK, A CRACK WAS FOUND IN UPPER END OF UPPER ACCESS PANEL FLANGE ON LT WING RIB 1 INSIDE WHEELWELL AFT OTBD CORNER. R & R ACCESS PANEL FLANGE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702169Floor Support · corrodedDURING C-CHECK CORROSION FOUND ON FLOOR SUPPORT, FRAMES 29-30. MAINTENANCE R & R LT FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702168Support · crackedDURING C-CHECK, FOUND A CRACK IN LOWER FORWARD CORNER OF LEFT SUPPORT ANGLE FOR NLG UP-LOCK BOX. MAINTENANCE R & R CRACKED SUPPORT ANGLE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702167Seat Track · corrodedDURING C-CHECK, LEFT WALL SEAT TRACK NR 5 CORRODED, AND GOUGED FRAMES 43-48. MAINTENANCE REMOVED CORROSION AND GOUGES AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702166Seat Track · corrodedDURING C-CHECK LT WALL SEAT TRACK NR 2 CORRODED. MAINTENANCE REMOVED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140628163Frame · crackedDURING C-CHECK, FRAME 10R CRACKED UNDER DV WINDOW. R & R FRAME IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626162VStand Off · crackedDURING C-CHECK, RT OMEGA BEAM AT FRAME 42 PIPE STAND OFF CRACKED. MAINTENANCE R & R RT SIDE OMEGA BEAM STAND OFF AT FRAME 42 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626161VRetainer · corrodedDURING C-CHECK, CORROSION, LOCAL LEVEL 2, AROUND RT EMERGENCY LIGHT 191 PANEL. MAINTENANCE R & R RT EMERGENCY LIGHT RETAINING RING IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626160Seat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 4 CORRODED FRAMES 43-48. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626159Seat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 5 CORRODED, FRAMES 53-59. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626158Seat Track · corrodedDURING C-CHECK, LEFT SEAT TRACK NR 3 CORRODED,FRAMES 29-35. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626157VSeat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 3 CORRODED, FRAMES 35-43. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626156Seat Track · corrodedDURING C-CHECK, LT SEAT TRACK NR 1 CORRODED, FRAMES 20-24. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626155Seat Track · corrodedDURING C-CHECK, LT SEAT TRACK NR 2, CORRODED AND GOUGED FRAMES 29-35. MAINTENANCE BLENDED SEAT TRACK AND IS WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626154Seat Track · corrodedDURING C-CHECK, LEFT SEAT TRACK NR 6 CORRODED, AND GOUGED FRAMES 53-59. MAINTENANCE BLENDED SEAT TRACK AND IS WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR OZCA20140623001O-Ring · damagedCREW RECEIVED HYD SYS 1 FAILURE MSG ON THE ICAS DURING DESCEND. AS A PRECAUTIONARY MEASURE, CREW ELECTED TO DECLARE AN EMER, SUBSEQUENT LANDING WAS UNEVENTFUL. FOUND A HYD LEAK AT ENG DRIVEN PUMP HYD PRESS SWITCH. REPLACED ENG DRIVEN HYD PUMP PRESS SWITCH OSDR V0XD2014062192732Seal · deterioratedAFT MAINTENANCE DOOR PANEL 312AR SEAL DETERIORATED. R & R WITH SERVICEABLE SEAL IAW AMM 52-44-02,SDR V0XD2014062192731Tube · damagedTUBE ASSY FORWARD OF RT PACK VALVE MISSING PART IF INSULATION. REPLACED DAMAGED TUBE ASSY WITH INSULATION WITH SERVICEABLE TUBE ASSY WITH INSULATION PN: 145-27547-409, IAW AMM 36-11-09 AND 21-51-01, WO 80232, WC 1265.SDR V0XD2014062192730Gasket · damagedRT UNDERWING FUEL PANEL 631CB HAS DAMAGED MESH GASKET. REPLACED MESH GASKET WITH SERVICEABLE GASKET PN:15-20060 IAW AMM28-11-01, WO 80232, WC 6018.SDR V0XD2014062192729Tank · crackedFUEL PROBE HAS CRACKED HOUSING. R & R TANK UNITSSDR V0XD2014062192733Attach Bracket · wornLOWER RT APU COWLING MOUNTING ATTACH POINT WILL NOT ACCEPT FASTENER. R & R APU COWLING MOUNTING, BRACKET, ATTACH POINTS IAW SRM 51-40-00.SDR V0XD2014062192728Pushrod · corrodedSPRING TAB PUSH ROD CORRODED. R & R PUSH ROD IAW AMM27-31-08.SDR RAIA201406140002Unknown · malfunctionedDURING CRUISE, LANDING GEAR WOULD NOT RETRACT, ACFT RETURNED TO DEPARTURE. REPLACED RT LANDING GEAR FWD WOW PROXIMITY SWITCH AND BOTH DOWNLOCK PROXIMITY SWITCHES, REPLACED NOSE DOWNLOCK SWITCH, LT LANDING GEAR FORWARD WOW SWITCH AND FWD DOWNLOCK SWITCH, OPSSDR V0XD2014061492727Floor Support · corrodedLEFT OMEGA BEAM AT FRAME 54 UNDERNEATH CENTER AISLE CROSSBEAM HAS A CORROSION HOLE. REPAIRED OMEGA BEAM IAW SRM 53-00-10.SDR V0XD2014061492726Floorbeam · crackedFLOORBEAM TEE CRACKED AT RT SIDE JUST AFT OF LAV. R & R FLOORBEAM TEE IAW SRM 51-40-02.SDR V0XD2014061492725Floor Support · corrodedRIGHT FLOOR SUPPORT AT FRAME 24 IS CORRODED. R & R FLOOR SUPPORT IAW SRM 51-40-02.SDR ASOA20140611082Starter Gen · failedTHE CREW REPORTED A STRONG ELECTRICAL BURNING ODOR IN THE COCKPIT AND CABIN WITH VISIBLE SMOKE IN THE COCKPIT WITH EVIDENCE OF AN APU FIRE. MAINTENANCE INSPECTED THE ACFT, FOUND NO EVIDENCE OF APU FIRE OR DAMAGE, FURTHER INSPECTION FOUND THE APU STARTER GENERSDR RAIA201406080001Seal · lack of lubeMAIN CABIN DOOR HARD TO OPEN DURING POST FLIGHT. MAINTENANCE LUBRICATED DOOR SEAL, OPS CHECKED GOOD.SDR V0XD2014061092724Floor Support · corrodedLT OMEGA BEAM AT FRAME 20 UNDERNEATH CENTER AISLE CROSSBEAM HAS HEAVY CORROSION. REPAIRED OMEGA BEAM IAW SRM 53-00-10 & CPM 51-21-04.SDR V0XD2014061092723Floor Support · corrodedRT FLOOR SUPPORT CORRODED OUT OF LIMIT AT FRAMES 35 TO 38. R & R FLOOR SUPPORT IAW SRM 51-40-02.SDR RAIA201406020001Duct · failedLOSS OF PRESSURIZATION IN MANUAL AND AUTOMODE DURING DESCENT THROUGH 10,000 FT. MAINTENANCE INSPECTED AND FOUND NR 2 PACK HAD A BLOWN DUCT, RESECURED AND OPS AND LEAK CHECK GOOD. MAINTENANCE ALSO FOUND THE SERVICE DOOR FRAME SEAL LEAKING, MAINTENANCE REPAIRESDR RAIA201405300001Flapper Valve · failedACFT WOULD NOT PRESSURIZE IN AUTO OR MANUAL DURING CLIMB OUT, RETURNED TO DEPARTURE. MAINTENANCE INSPECTED AND FOUND GROUND SERVICE FLAPPER OPEN, SECURED CLOSED AND OPS CHECKED PRESSURIZATION SYS, OPS CHECKED GOOD.SDR RAIA201405280001Control Valve · leakingWING ANTI-ICE FAILED DURING CLIMB OUT, RETURNED TO DEPARTURE. MAINTENANCE INSPECTED AND FOUND A LEAK AT PACK. REPLACED DUAL TEMP CONTROL VALVE, OPS CHECKED WING ANTI-ICE AND PACK SYS, OPS CHECKED GOOD.SDR ASOA20140528095Valve · failedHIGH STAGE VALVE FAIL MESSAGE ON EICAS. R & R NR 2 HIGH STAGE VALVE IAW AMM 36-11-02. OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA201405240002Frame · corrodedFRAME 14 BETWEEN STRINGERS 21L AND 21R HAS CORROSION. MAINTENANCE REPAIRED FRAME. MAJOR REPAIR.SDR RAIA201405240001Light · crackedEMERGENCY LIGHT CRACKED AT 1A. REPLACED EMERGENCY LIGHT. OPS CHECKED GOOD.SDR RAIA201405210001Door · lack of lubeTHE MAIN PASSENGER DOOR DIFFICULT TO OPEN DURING POST FLIGHT. MAINTENANCE INSPECTED AND LUBED DOOR, OPS CHECK GOOD.SDR RAIA201405200001Shear Tie · corrodedSHEAR TIE AT FRAME 13 BETWEEN STRINGERS 18 - 21R IS CORRODED. MAINTENANCE REPLACED SHEAR TIE.SDR RAIA201405190005Stringer · corrodedSTRINGER 21R FORWARD OF FRAME 14 IS CORRODED. MAINTENANCE REPLACED STRINGER.SDR RAIA201405190004Shear Tie · corrodedSHEAR TIE, FRAME 61 BETWEEN STRINGERS 20 - 21R IS CORRODED. MAINTENANCE REPLACED SHEAR TIE.SDR RAIA201405190003Stringer · corrodedSTRINGER 21R BETWEEN FRAME 60 AND 61 IS CORRODED. MAINTENANCE REPLACED STRINGER.SDR RAIA201405190002Support · corrodedSUPPORT ON STRINGER 21L BETWEEN FRAME 60 - 61 IS CORRODED. MAINTENANCE REPLACED SUPPORT.SDR RAIA201405190001Battery Pack · inoperativeEMERGENCY LIGHT BATTERIES DISCHARGED DURING PREFLIGHT. MAINTENANCE REPLACED ALL BATTERIES AND OPS CHECKED GOOD.SDR RAIA201405170004Strap · corrodedSKIN STRAP BETWEEN FRAMES 13 AND 14 HAS CORROSION. MAINTENANCE REPLACED SKIN STRAP.SDR RAIA201405170003Profile · corrodedPROFILE AT STRINGER 21R BETWEEN FRAMES 13 AND 14 HAS LEVEL 2 CORROSION. MAINTENANCE REPLACED PROFILE.SDR RAIA201405170002Profile · corrodedLEFT PROFILE AT STRINGER 18R BETWEEN FRAMES 13 AND 14 HAS CORROSION. MAINTENANCE REPLACED THE PROFILE.SDR RAIA201405170001Stringer · corrodedSTRINGER 18R BETWEEN FRAMES 13 AND 14 HAS CORROSION. MAINTENANCE REPLACED STRINGER.
Back to Embraer EMB-145EP