Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2021062100267Line · crackedDURING FLIGHT WING A/I FAIL MESSAGE APPEARED. FOLLOWED QRH AND MESSAGE REMAINED. HA300 FACTED OUT AS - T/S IN REF TO FIM 30-11-00-810-801-A. INSPECTED ENG BLEED DUCTS ON #2 ENGINE. FOUND CRACK ON Y-PIPE BETWEEN ENGINE A/I VALVE AND HIGH STAGE VALVE. R&R'D ENSDR HNAA2021062100265Engine · odorBURNING OIL SMELL IN COCKPIT ALSO CAUSING EYE IRRITATION. REMOVED AND REPLACE #1 ENGINE. OP CK AND LEAK CHECKS GOOD.SDR SIMA20210618001Lamp · inoperativeAFT OVERWING EMERGENCY LIGHT INOP-C/A-RAR AFT OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A NO FIX. RAR OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-07-000-802-A AND 33-50-07-400-802-A. OPC GOOD. ENDSDR SIMA20210618003A/C Pack · odorDURING CLIMB OUT OF ORD MINOR SMELL OF POSSIBLE OVERHEATED PLASTIC AND OR RUBBER SEEMINGLY COMING FROM OVER #1 PACK. SMELL WENT AWAY RATHER QUICKLY NO ABNORMAL MESSAGES OR INDICATIONS OTHERWISE. ON APPROACH INTO GSP SMELL RETURNED STRONGLY AND PACK STRUGGLED TSDR SIMA20210618002Inverter · inoperativeEMERGENCY INTERIOR LIGHT ADJ TO RH EMERGENCY EXIT INOP-C/A-REF TURNOVER, COMPLETED RAR OF #5 EMERG LIGHTS INVERTER IAW AMM 33-50-11. OPC GOOD.SDR SIMA2021072100005Cradle · brokenFWD FLIGHT ATT EMERGENCY FLASH LIGHT HOLDER BROKEN-C/A-COMPLETE:REMOVED AND REPLACED FLASHLIGHT ASSY IAW AMM 33-50-16 OPS CK GOODSDR SIMA2021072100006Seal · wornLEFT AND RIGHT OVERWING EMERGENCY EXIT SIGN SEAL IS WORN AND TORN..-C/A-COMPLETE:SEAL RAR IAW EMB-145 AMM 52-21-01 AND ETN-EM-52-069. SEE BOW 356061 FOR TEST FOR CABIN LEAKAGE.SDR SIMA20210617004Wire · detachedAFT EMERGENCY FLOOR STRIP LIGHT, OVER FLOOR PANEL 251HF. WIRE SEPARATED FROM PLUG. INSTALLED CONNECTOR ON EMERGENCY STRIP LIGHT IAW E145 SWMP 20-21-00.SDR SIMA20210617001Flashlight · inoperativeFA FORWARD EMERGENCY FLASHLIGHT INOP. R & R FA FORWARD EMERGENCY FLASHLIGHT ASSY IAW EMB 145 - AMM 33 - 50 - 16, OPC IS GOOD.SDR SIMA20210617002Smoke Detector · illuminatedBAGG SMOKE INDICATION IN FLIGHT AT FL210 QRH PROCEDURES COMPLIED WITH EMERGENCY DECLARED "TRANSFERRED TO NRWC 663-ORD-05135"-C/A-RAR CARGO FIRE EXT BOTTLES IAW AMM 26-23-01 PERFORMED OPS CHECK OF CARGO SMOKE DETECTION SYSTEM IAW AMM 26-15-00 NO FAULTS FOUNDSDR SIMA20210617003Warning Message · false activationINBND MIA DECLARED EMEREGNCY FOR SPOILER FAIL. COMPLIED W/QRH, NO CHANGE. THEN AT BASE LEG DROPPED MLG, CONFIGURED FOR LANDING, EICAS MSG -INDICATIONS WENT AWAY. REF. LOG PAGE 4770561-1 - C/W DEACTIVATION OF SPOILERS BY PULLING AND COLLARING CB S F13, F14 ANDSDR SIMA20210616003Link · crackedRH ENGINE YOKE FORWARD LOWER LINK IS CRACKED ON OUTBOARD SIDE NEAR RADIUS. (MAJOR REPAIR)-C/A-COMPLETE:REPAIRED RH ENGINE YOKE FWD LOWERLINK IAW ERS-EM-54MR-698.SDR SIMA20210616002Control Unit · failedSPOILER FAIL EICAS MESSAGE AT CRUISE WITH SPLRS INDICATION SHOWING OPN BUT SPOILERS VERIFIED CLOSED BY FA DECLARED EMERGENCY. QRH PROCEDURE C/W MESSAGES CLEARED AFTER PULLING CBS INSTRUCTED IN QRH-C/A-T/S PER FIM RAR SPOILER CONTROL UNIT IAW AMM 27-63-02 OPS CSDR SIMA20210616001Transducer · faultedENG 1 LOSS OF OIL PRESS IND DURING TAKEOFF ROLL (LOW SPEED REJECT ABOUT 40 KTS). THERE WAS NO EICAS "E1 OIL LOW PRESS" MESSAGE. OIL PSI WENT TO MOSTLY 6 PSI.-C/A-RAR OIL TEMPERATURE/PRESSURE SENSOR TRANSDUCER IAW AMM 79-31-01. PERFORMED OPERATIONAL CHECK. DID SDR HNAA2021061600264Wire · brokenCOCKPIT THRESHOLD STEP, EMERGENCY LIGHT SIGN IS INOP. REMOVED COCKPIT THRESHOLD PANEL, FOUND WIRE BROKEN AT QUICK DISCONNECT CONNECTOR, INSTALLED NEW CONTACT PIN AND MALE CONNECTOR ONTO WIRE, CONNECTED QUICK DISCONNECT CONNECTORS, OPS CHECKED LIGHTS, OPS CHECKSDR HNAA2021070100309Floor Support · corrodedL/H FLOOR SILL #3 IS CORRODED AT A PREVIOUS BLEND BETWEEN FRAMES 29-30. REMOVED AND INSTALLED SERVICEABLE LH #3 FLOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2021070100303Shear Tie · corrodedFR 65 SHEAR CLIP CORRODED AT CARGO DOOR LOWER SILL. CUT, POSITIONED, DRILLED AND INSTALLED SPLICE REPAIR ON FR 65 SHEAR CLIP AT CARGO DOOR LOWER SILL IAW ETD2021--145-019276 REV A AND EO1-53-21-0147.SDR SIMA20210614003Proximity Sensor · faultedSPOILER FAIL, EMERGENCY DECLARED.- R/H & L/H OUTBOARD SPOILER PROXIMITY SWITCH CONNECTOR IS CORRODED.-C/A-RAR L/H OB SPOILER PROX. SWITCH IAW EMB-145 MM 27-63-04. OPS CK GOOD. REF NRWC 653-ORD-05471 FOR SUPPORTING ACTIONSDR HNAA2021061600263Indicator · faultedDURING TAXI FUEL QTY LOW MASTER WARNING APPEARED WITH FUEL INDICATION GOING TO DASHES ON EICAS. (HAPPENED AS A/C RECEIVED PERMISSION TO ENTER RWY). PERFORMED OPS CHECK IAW AMM 28-41-00. OPS CHECK GOOD. OK FOR SERVICE. ALL FUEL QUANTITY INDICATIONS NORMAL ASDR SIMA20210614001Light · inoperativeFLOOR EMERGENCY LIGHTS, 2 AND 3 INOP. R & R 2 AND 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIPS IAW EMB145 AMM 33-50-12. OPS CHECK GOODSDR SIMA20210614002Brake Sys · unknownMECH / BRAKE DEGRADE , EMERGENCY DECLARED- BRAKE DEGRADED ON GEAR EXTENSION. C/W FIM TASK 32-41-00 FOUND TO BE A TRANSATORY CONDITION ON BRAKE SYSTEM , NO CMC FAULT FOUND A/C OK FOR SERVICESDR SIMA20210614004Unknown · odorODD ODOR COMING FROM APU BLEED WHEN APU BLEED WAS SELECTED.-C/A-PERFORMED FIM 21-20-00-810-801A AND ETN-EM-72-034 R10 COULD NOT DUPLICATE DISCREPANCY. NO ODORS FOUNDSDR HNAA2021070100308Gusset · corrodedRH OMEGA BEAM GUSSET #3 CORRODED. REMOVED AND REPLACED RH OMEGA BEAM GUSSET #3 IAW EMB145 SRM 51-40-02.SDR HNAA2021070100302Floor Support · corrodedCARGO DOOR CUTOUT LOWER FLOOR SILL CORRODED. REMOVED AND PERFORMED INSTALLATION OF SERVICEABLE CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021061400261Solenoid Valve · faultedLOUD AIR NOISE AND VIBERATION FROM NLG AREA AFTER RETRATION OF GEAR. R&R NLG DOOR SOLENOID VALVE REF 32-33-02. LEAKS AND OP CKS GOOD OK FOR SERVICE.SDR HNAA2021061400260Warning Message · false indicationDURING LANDING WHEN SELECTING FLAPS TO 45 MAIN PITCH TRIM AND BACK UP PITCH TRIM INOP BOTH APPEARED ON EICAS. PER FIM TASK 27-43-00-810-820-A FIM PROCEDURES BLOCK DIAGRAM BLOCKS 3&8 HORIZONTAL STAB ELECTRNIC OPERATIONAL TEST AMM TASK 27-40-00-802-A/500 TRANSISDR SIMA20210613004Lamp · inoperativeROW 12 EMERGENCY LIGHT INOP-C/A-RAR ROW 12 EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.SDR SIMA20210613002Flashlight · inoperativeFA FORWARD EMERGENCY FLASHLIGHT INOP-C/A-FLIGHT CREW PLACARDED FORWARD FA EMERGENCY FLASHLIGHT-M PROCEDURES C/W AUTH# 060188-D REF# 25-32 MOC# 206396SDR SIMA20210613003Light · inoperativeAFTMOST CABIN EMERGENCY LIGHT STRIP INOP-C/A-RAR AFTMOST CABIN EMERGENCY LIGHT STRIP IAW EMB 145 AMM 33-50-12 OPS CHECK GOODSDR ..SIMA20210613005Wire Harness · damagedMECHANICAL / LANDING GEAR GND FAIL MSG AFTER TAKEOFF EMERGENCY DECLARED- BRAKE OVERHEAT CAUTION MESSAGE. ERRATIC RT INBOARD - PEGGED AT MAX TEMP -MEL 3203 AUTH 060159DM-C AML 4764592 ITEM 1.-C/A-TROUBLESHOT RH MLG BRAKE TEMP INDICATION HARNESS IAW SWPM 20-20-0SDR SIMA20210613001Brace · corrodedLT FWD MLG SIDEBRACE BORE (IN GEAR WELL) HAS PITTING CORROSION (LEVEL 1 CORROSION) MAJOR REPAIR-C/A-REPLACED FITTING IAW ERS-EM-57MR-1310SDR HNAA2021070100307Floor Support · corrodedRH #2 FLOORBOARD SILL CORRODED. REMOVED AND REPLACED RH #2 FLOORBOARD SILL IAW EMB 145 SRM 51-20-03.SDR HNAA2021070100306Floor Support · corrodedRH #3 FLOORBOARD SILL CORRODED. REMOVED AND REPLACED #3 FLOORBOARD SILL IAW EMB145 SRM 51-40-02.SDR HNAA2021070100305Gusset · corrodedCENTER LAV OMEGA BEAM GUSSET CORRODED AT AFT END. REMOVED AND REPLACED CENTER LAV OMEGA BEAM GUSSET EMB 145 SRM 51-10-02.SDR HNAA2021070100304Panel · corrodedRH LAV BANANA PANEL CORRODED AT LOWER END. REMOVED UNSERVICEABLE AND INSTALLED SERVICEABLE R/H LAV BANANA PANEL IAW EMB 145SRM 51-40-02.SDR HNAA2021070100301Gusset · corrodedRH OMEGA BEAM GUSSET #2 CORRODED. REMOVED AND REPLACED R/H OMEGA BEAM GUSSET #2 IAW EMB 145 SRM 51-40-02.SDR HNAA2021070100300Floor Support · corrodedLH #7 FLOORBOARD SILL CORRODED. REMOVED AND INSTALLED NEW LH #7 FLOORBOARD SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021070100299Gusset · corrodedRH LAV OMEGA BEAM GUSSET CORRODED AROUND NIPPLES. REMOVED UNSERVICEABLE RH LAV OMEGA BEAM GUSSET & INSTALLED SERVICEABLE R/H LAV OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2021070100298Floor Support · corrodedCARGO RH OUT BOARD FLOOR SILL CORRODED BETWEEN FRAMES63-65. REMOVED CORRODED CARGO RH OUT BOARD FWD FLOOR SILL, POSITIONED DRILLED AND INSTALLED SERVICEABLE FLOOR SILL IAW EMB 145 SRM 51-40--02, 51-20-03, APPLIED PAINT TOP COAT IAW EMB 145CPM 51-21-06 PIEDMONSDR HNAA2021061400262Acm · fumesON DESCENT AT 24K FT FUMES NOTICED IN COCKPIT. FOLLOWED QRH, TURNED OFF GASPER, RECIRC, AND WINDSHIELD HEAT. SMELL SEEMED TO DISSIPATE. ON GROUND RESIDUAL SMELL REMAINED. FIRE CREW NOTED C/B E28 BAGGAGE RECIRC HOT. PERFORMED OPS CHECK OF BAG BAY VENTILATIONSDR SIMA20210611002Unknown · multiple failON APPROACH PHASE APROX @ 17000 FT WITH AUTOPILOT ON WE STARTED GETTING MECHANICAL MULTIPLE ALERTS GPWS WARNING " LANDING GEAR, BANK ANGLE, TOO LOW TERR, TERRAIN, TERRAIN," AURAL WARNING'S WITH NO EICAS MESSAGES. DECLARED EMERGENCY.-C/A-PERFORMED OPT OF EGPWS/SDR HNAA2021062400286Skin · damagedSMALL PROTRUSION ON EXTERNAL SKIN JUST FWD OF FRAME 24 BETWEEN STR 17R-18R. REPAIRED SMALL PROTRUSION ON EXTERNAL SKIN JUST FWD OF FRAME 24 BETWEEN STR 17R-18R IAW PIEDMONT EO1-05--21-0146, AND EMB145 SRM 53-22-01.SDR SIMA20210610001Light · inoperativeRH OVERWING EMERGENCY LIGHT IS INOP.-C/A-RAR RH OVERWING EMERGENCY LIGHT IAW EMB145 AMM 33-50-10. OPC GOOD.SDR SIMA20210609004Compressor · damagedENG 1 FAILURE ON CLIMBOUT, AFTER T/O CHECK COMPLETE, PASSING 5,500 FT LOUD BANG ENG 1 FAIL MESSAGE ON EICAS E1 FAILURE / DECLARED EMERGENCY / EQP SWAP FLT CONT. ENG #1 INSP REVIELED HEAVY DAMAGE TO COMPRESSOR, PERFORMED ENGINE REPLACEMENT OF #1 ENGINE AS PER SDR SIMA20210609001Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IN REFERENCE WITH EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20210609003Proximity Switch · failedINBOUND DFW LG AIR GRND FAIL CAUTION / DECLARED EMERGENCY- "TRANSFERRED FROM AML PAGE 4764587 ITEM 2-LG AIR/GND FAIL EICAS CAUTION PCESENT AT - FL 180 -> GROUND-C/A-RAR LH AFT WOW PROXIMITY SWITCH IAW AMM 32-63-01.PERFORMED AIR/GROUND OPERATIONAL CHK IAW AMM 3SDR ASOA202107010182Skin · distortedDISCREPANCY - LEFT HAND SIDE FUSELAGE JUST AFT OF ENTRY DOOR AND FORWARD OF REPAIR HAS "OIL CANNING" AND DISTORTION THAT IS APPROXIMATELY 2 INCH'S SQUARE. CORRECTIVE ACTION - REPAIRED LEFT HAND SIDE FUSELAGE JUST AFT OF ENTRY DOOR IN ACCORDANCE WITH EMB 145 SRSDR HNAA2021060900235Actuator · faultedPITCH TRIM BACK UP INOP. R&R HORIZONTAL STABILIZE ACTUATOR IAW EMB 145 AMM 27-40-02-000/A00-801A REQUIRES ZERO RIG CHECK AMM TASK 27-40-02-700-801-A/500. PERFORMED ELECTRICAL ZERO POSITION OF HORIZONTAL STABILIZER IAW AMM 27-40-02-801-A/500 OPS CHECK GOOD P/N SDR SIMA20210608002Support · undertorquedMAIN CABIN DOOR DIFFICULT TO OPEN AND CLOSE-C/A-C/W ETN-EM-52-052 RE-TORQUED HANDLE SUPPORT ASSEMBLY. REFERENCE AML PAGE # 4406449 ITEM #1 FOR TDMI FOR REPAIR.OPS CHECK GOOD.SDR SIMA20210608001Charger · inoperativeBOTH OVERWING EMERGENCY LIGHTS INOP-C/A-RAR #4 BATTERY AND CHARGER ASSEMBLY IAW EMB 145 AMM 33-50-04. OPS CHECK GOOD.
Back to Embraer EMB-145LR