Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20210607001Flashlight · inoperativeAFT FA EMERGENCY FLASHLIGHT INOP. R & R AFT FA'S FLASH LIGHT IAW EMB 145 AMM 33-50-16. OPERATIONAL CHECK GOOD.MEL RESTORED.SDR SIMA20210607002A/C Pack · failedDIVR LSE ACCT AC PACK 2 FAIL-PACK 2 VALVE CLOSED ADVISORY-C/A-FLIGHT CREW PLACARDED OUTFLOW VALVES M PROCEDURES C/W REF MEL 21-22 AUTH 060100DM-C MOC 680820SDR HNAA2021062400281Floor Support · corrodedLH OUTBD #3 FLOOR SILL IS PITTED. REMOVED AND REPLACED LH OUTBD #3 FLOOR SILL IAW EMB 145 SRM 51-20-03 & SRM 51-40-02.SDR HNAA2021062400280Seat Track · corrodedRH OUTBD AFT SEAT TRACK RAIL IS CORRODED AT FR. 54 AND FR. 55. REMOVED CORROSION ON RH OUTBOARD AFT SEAT TRACK RAIL AT FR 54 AND FR 55 IAW EMB 145SRM 51-10-03 AND FOUND BLENDED AREAS TO BE WITH-IN ALLOWABLE LIMITS IAW EMB 145 SRM 53-00-11.SDR HNAA2021060700233Acm · failedIN CRUISE FLT AT FL 250 LIGHT GREY SMOKE AND ELECTRICAL SMELL IN COCKPIT AND CABIN. FA REPROTED LOUD SQUEALING NOISE COMING FROM PACK 2. SMOKE AND SMELL ALONG WITH NOISE DISAPPATED WHEN PACK 2 TURNED OFF MX R&R #2 ACM REF AMM 21-51-03SDR SIMA20210605002Light · inoperativeDURING PS-1 CHECK FOUND RH CENTER FAIRING EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR EMERGENCY EXTERIOR LIGHT PER AMM 33-50-10SDR SIMA20210605001Lamp · inoperativeRT OVERWING EMERGENCY LIGHT INOP. R & R RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD. END.SDR HNAA2021060700234Compressor · making metalDURING CLIMB OUT WITH N1 AROUND 91%. LOUD BANG HEARD FROM ENGINE #1 FOLLOWED QUICKLY BY ENGINE SHUTDOWN. PERFORMED GVI OF #1 ENGINE. FOUND METAL FOD IN FIRST STAGE COMPRESSOR SECTION, WITH DAMAGE TO MULTIPLE INLET GUIDE VANES. NO OBVIOUS DAMAGE OR BIRD STRIKSDR SIMA20210604001Acm · seizedSMOKE IN THE CABIN AND ASSOCIATED BURNING SMELL WHEN PACK 2 WAS RESET AFTER T/O FA NOTED ITSEEMED TO COME FROM CENTER OF A/C-SMOKE IN CABIN WORK SCOPE ISSUED BY REPEAT CONTROL REQUIRES CMC DOWNLOAD AND REVIEW. C/W CMC DOWNLOAD IAW MM 45-45-00 AND UPLOADED TO SDR HNAA2021061400256Spar · damagedLH WING SPAR 1 RIB 9 AREA HAS RELEVANT INDICATION AT LOWER FLANGE FWD OF SCREW HOLE ... ACCOMPLISHED REPAIR OF LH SPAR I AT RIB 9 IAW EMB 145 SRM 57-20-05 ITEM 2, FIG 201 SHEET 1 AND PIEDMONT EO1-57-21-0121. PERFORMED LEAK CHECK ON LH WING SPAR 1 RIB 9 IAW EMBSDR HNAA2021061400236Floor Support · corrodedCORROSION ON INBD SIDE LT OMEGA BEAM AT FRAME 20 ... REMOVED, FABRICATED AND INSTALLED REPAIR PARTS ON LH OMEGA BEAM AT FR 20 IAW EMB145 SRM 53-00-10 ITEM #2 FIG. 201 SHEET 1 AND PIEDMONT EO1-53-21-0128SDR SIMA20210603004Frame · damagedFRAME 67 HAS 2EA ELONGATED HOLES AT THE END OF THE FRAME THAT CONNECTS TO CARGO DOOR SILL.-C/A-REPAIRED IAW SRM 53-00-04.SDR SIMA20210603005Roller · lack of lubeMAIN CABIN DOOR HARD TO OPEN.-C/A-LUBED MAIN DOOR ROLLERS AND HANDLE, DOOR OPEN AND CLOSED OK AFTER REF AMM 52-10-01.SDR SIMA20210603001Frame · damagedFRAME 66 HAS 2EA ELONGATED HOLES AT THE END OF THE FRAME THAT CONNECTS TO CARGO DOOR SILL.-C/A-INSTALLED NEW FRAME SECTION AND SPLICE AT FR 66 IAW SRM 53-00-04 FIG 201.SDR SIMA20210603003Radio Altimeter · faultedCLIMBING THROUGH 15,000FT RA MOMENTARILY STUCK AT 20FT AND GOT TO LOW TERRAIN AURAL WARNING.-C/A-DEFERRED PER MEL 34-8 AUTH # 060025 DM-A EXP 6-5-21 ?M? PROCEDURES C/WSDR HNAA2021060200232Warning Message · false activationPDIS 632 27-36 2379001 01JUN21 EVV CLOSE
SPS 1-2 INOP, SPS ADANCE, NO TAKEOFF CONFIG DURING TAKEOFF MESSAGES CLEARED WHEN A/C STOPPING.
FACT 01JUN21 10:52 EVV
PERFORMED SPS OPS CHECK IAW AMM 27-36-00-700-801-A. OPS CHECK GOOD.SDR SIMA20210531002Lamp · inoperativeRH UPPER OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH UPPER OVER WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10. OPC GOOD.SDR HNAA2021060100231Warning Message · false activationPDIS 686 27-41 2396533 31MAY21 CLT CLOSE
ON FINAL PITCH TRIM MAIN INOP MESSAGE APPEARED ON EICAS
FACT 31MAY21 20:17 CLT
PDPU CND C/W TASK 27-40-00-700-802-A AND 27-40-00-700-803-A NO DEFECTS NOTED OPS CHECK GOOD A/C OK FOR SERVSDR SIMA20210530001Roller · lack of lubeFA REPORTS DOOR IS VERY HARD TO OPEN. (MAIN CABIN DOOR)-C/A-PERFORMED SERVICING OF THE MAIN DOOR FRAME - LUBED ROLLERS IAW AMM 53-21-02. OPS CHECK GOOD.SDR SIMA20210530002Power Supply · inoperativeAFT AISLE EMERGENCY SIGN AND SEAT 12A EMERGENCY OVER HEAD LIGHT INOP-C/A-T/S IAW FIM TASK 33-50-00-810-804-A RAR #3 BATTERY POWER SUPPLY AND BATTERY PACK IAW EMB AMM 33-50-04-000-801-A AND 33-50-04-400-801-A AND 33-50-04-000-802-A AND 33-50-04-400-802-A OPS CHSDR SIMA20210529001Inverter · inoperativeSEAT 12C WALL EMERGENCY SIGN INOP-C/A-T/S IAW WM 33-50-50-005 RAR #5 INNVERTER IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A OPS CHECK GOOD NO FURTHER DEFECTS NOTED AT THIS TIMESDR SIMA20210528002Frame · corrodedSERVICE DOOR AFT LOWER SURROUND HAS CORROSION AROUND NUTPLATE HOLE FOR LOWER TRIM. (ON FRAME 22R, BETWEEN LOCATION STR 15R AND STR 16R) (LEVEL 1 CORROSION MAJOR REPAIR)-C/A-REPAIRED SERVICE DOOR AFT LOWER SURROUND FRAME 22, BETWEEN STRINGERS 15R AND 16R IAW SRSDR HNAA2021060100230Warning Message · illuminatedON TAXI, ICE COND, NO ICE -A/ICE ON, ICE COND - A/I INOP, AND ENG REF A/I DISAGREE MESSAGES APPEARED ON EICAS WHILE A/I SET TO AUTO. C/W R&R FIM 73-25-00-810-836 FOUND TAKE OFF DATA A/ICE CONDITION ENTERED WAS NOT THE SAME AS A/ICE SWITCH POSITION. C/W A/ICESDR HNAA2021060100229Unknown · odorELECTRICAL SMELL IN CRUISE AND DESENT IN RAIN WITH W/S HEAT ON. OPS CHECKED W/S HEAT SYSTEM,WINDSHIELD WIPER SYSTEM, AND RAN APU AND PACKS PER AMM 20-42-00 AMM 21-00-00 AND AMM 30-41-00 RESPECTIVELY OPS CHECK OK NO FAULTS NOTED AT THIS TIME.SDR HNAA2021060100228A/C Pack · odorDURING CRUISE FLT AT 25000FT STRONG BURNING PLASTIC SMELL IN COCKPIT FOLLOWED SHORTLY IN CABIN. FOLLOWED QRH AND SMELL MITIGATED BUT REMAINED UNTIL ON GROUND. NO SMOKE NOTED. INSPECTED PACK SYSTEMS FOR BURNING SMELL. MX FOUND BURNING SMELL IS FROSDR SIMA20210528001Power Supply · failedEMERGENCY LIGHT NOT ARMED CAUTION MESSAGE AFTER TAKEOFF. RAN QRH AND DIDN?T FIX PROBLEM. C19 CRCT BRKR POPPED AND EMER LGTS LASTED 20 MIN-C/A-RAR EMERGENCY LIGHT POWER SUPPLIES IAW WC 33-700-19. FOUND SIGNIFICANT EXCEPT AS NOTED IN FOLLOW ON ITEMS, OPS CHECK GSDR SIMA20210527007Skin · crackedR/H FUSELAGE SKIN HAS A CRACK APROX 1/2 INCH LONG AT FR 75 BETWEEN STRS 1R AND 3R-C/A-REPAIRED RH FUSELAGE SKIN AT FR75 BETWEEN STR 1R AND 3R IAW SRM 53-31-01. ENTERED INTO DT # DT-EM-53-1367 AND DTEM-53-1368.SDR SIMA20210527008Floor Support · crackedCARGO DOOR SILL FLOOR SUPPORT ANGLES AT FRAME 66 AND 67 ARE CRACKED. -C/A-RAR CARGO DOOR SILL SUPPORT ANGLES AT FRAME 66 AND 67 IAW SRM 51-40-02.SDR JJBA20210527027Electronic Unit · inoperativeAIR/GRD FAIL MESSAGE IN FLIGHT (WHEN GEAR WAS SELECTED DOWN MESSAGE APPEARED, THEY DID GET # GREEN DOWN AND LOCKED - MESSAGE STAYED ON UNTIL TOUCHDOWN). REMOVED AND REPLACED UPPER AND LOWER WOW SWITCH ON LH GEAR. R&R LGEU. OPS CECK SAT. NO FAULT NOTED. ALSO HOSDR SIMA20210527006Bushing · wornLH AILERON OUTBD PCA BUSHINGS WORN. (MAJOR REPAIR)-C/A-RAR LH AILERON PCA FITTING IAW EO EM-27MR-112.SDR SIMA20210527004Skin · crackedFUSELAGE SKIN IS CRACKED AT FR 77, 5TH RIVET DOWN FROM STR 3R. (1/16"LONG) - FUSELAGE SKIN IS CRACKED AT FR 77, 1ST RIVET DOWN FROM STR 4R. (1/16"LONG-C/A-C/W BUSHING REPAIR IAW SRM 53-32-01. C/W BUSHING REPAIR IAW SRM 53-32-01.SDR SIMA20210527005Skin · crackedFUSELAGE SKIN HAS 6 CRACKS AT FR 77, 1ST RIVET UP FROM STR 4L. (1/32" LONG). FUSELAGE SKIN HAS 6 CRACKS AT FR 77, 1ST RIVET DOWN FROM STR 4L. (1/32" LONG). FUSELAGE SKIN HAS 2 CRACKS AT FR 77, 1ST RIVET UP FROM STR 6L. (1/32" LONG).. FUSELAGE SKIN HAS 1 CRACK SDR SIMA20210527003Attach Bracket · crackedCARGO DOOR LIFTING MECHANISM FORWARD ATTACH BRACKET IS CRACKED. -C/A-RAR BRACKET IAW SRM 51-40-02.SDR SIMA20210527002Torque Link · looseNOSE WHEEL SHYMMY ON BOTH HIGH AND LOW SPEED ROLLOUT.-C/A-FOUND TORQUE LINK TO BE LOOSE. TIGHTEN AND RESECURED TORQUE LINK CASTLATED NUT IAW AMM 32-20-10. TAXI CHECK GOOD.SDR SIMA20210527001Receptacle · crackedSTIFFENER ON AFT SIDE OF FRAME 68 FOR CARGO DOOR HOLD OPEN RECEPTACLE HAS A 1/2" CRACK-C/A-INSTALLED NEW STIFFENER IAW SRM 51-40--02SDR SIMA20210526005Drag Angle · crackedVERTICAL STAB TO FUSELAGE RT SIDE DRAG ANGLE IS CRACKED IN 2 AREAS. (MAJOR REPAIR)-C/A-C/W VERTICAL STAB TO FISELAGE DRAG ANGLE REPAIR IAW ERS-EM-53MR-4355SDR HNAA2021061400254Floor Support · corrodedCARGO COMPARTMENT LH #2 FLOOR SILL CORRODED ... REMOVED CORRODED CARGO COMPARTMENT LH #2 FLOOR SILL AND POSTIONED, DRILLED, AND INSTALLED SERVICEABLE CARGO COMPARTMENT LH #2 FLOOR SILL IAW EMB 145 SRM 51-40-02 AND SRM 51-20-03SDR HNAA2021061400253Floor Support · corrodedCARGO COMPARTMENT LH #3 FLOOR SILL CORRODED ... REMOVED CORRODED CARGO COMPARTMENT LH #3 FLOOR SILL AND POSTIONED, DRILLED, AND INSTALLED SERVICEABLE CARGO COMPARTMENT LH #3 FLOOR SILL IAW EMB 145 SRM 51-40-02 AND SRM 51-20-03SDR HNAA2021061400252Door Sill · corrodedSSI 53-30-48: CARGO DOOR FRAME CUTOUT SILL CORRODED ... COMPLETED REMOVAL AND INSTALLATION OF SERVICEABLE CARGO DOOR CENTER SILL IAW EMB 145 SRM 51-40-02SDR SIMA20210526004Support · crackedSUPPORT FOR CARGO DOOR TORSION BAR AT FR 68 HAS A 1/4" CRACK. ( DURING EVALUATION FOUND 3 CRACKS)-C/A-RAR SUPPORT ASSEMBLY FOR CARGO DOOR TORSION BAR AT FRAME 68 IAW SRM 51-40-02.SDR SIMA20210526001Flashlight · not seatedEMERGENCY FLASHLIGHT ABOVE F/A SEAT WILL NOT CHARGE. (ONLY SHOWS RED LIGHT WHEN TEST BUTTON PRESSED, AFTER RE-SEATING)-C/A-RAR FLASHLIGHT ASSEMBLY ABOVE F/A SEAT IAW EMB145 AMM 33-50-16. OPC GOOD.SDR SIMA20210526003Battery · faultedFA EMERGENCY FLASHLIGHT FLICKERING ON AND OFF-C/A-RAR FA EMERGENCY FLASHLIGHT BATTERY IAW E145 AMM 33-50-16. OPS CKED GOOD. IAW E145 AMM 33-51-01SDR HNAA2021062400291Plate · damagedPILOT'S BULKHEAD ATTACHMENT UPPER BOLT HOLE ELONGATED. REMOVED AND REPLACED PILOTS BULKHEAD PLATE IAW EMB145 SRM 51-40-02.SDR HNAA2021061400259Longeron · corrodedCORROSION ON LH ENGINE UPPER COWLING OTBD LONGERON UNDER AFT HINGE FITTING ... SEE NRTC# E862591 FOR REPLACEMENT OF LH ENGINE UPPER COWLING OUTBD LONGERON.SDR HNAA2021061400258Longeron · corrodedCORROSION ON LH ENGINE UPPER COWLING OTBD LONGERON UNDER CENTER HINGE FITTING ... SEE NRTC # E862591 FOR REMOVAL AND REPLACEMENT OF LH UPPER ENGINE COWLING OUTBOARD LONGERONSDR HNAA2021061400251Shear Tie · corrodedSSI 53-30-48: CARGO DOOR FRAME CUTOUT FR65 SHEAR CLIP CORRODED (MARKED). ... REPAIRED CARGO DOOR FRAME CUTOUT FR65 SHEAR CLIP IAW EMB 145 SRM 53-31-04RE ITEM 4 AND EO1-53-21-0124SDR HNAA2021061400249Floor Support · corrodedCARGO COMPARTMENT RH #4 FLOOR SILL CORRODED ... REMOVED AND REPLACED CORRODED CARGO COMPARTMENT RH #4 FLOOR SILL IAW EMB 145 SRM 51-40-02 AND SRM 51-20-03.SDR HNAA2021061400248Seat Track · corrodedCORROSION ON RH INBD # 5 SEAT TRACK GUSSET ... REMOVED AND INSTALLED SERVICEABLE RH INBD #5 SEAT TRACK GUSSET IAW EMB145 SRM 51-40-02.SDR HNAA2021061400247Floor Support · corrodedCORROSION ON LH OTBD #5 FLOOR SILL ... REMOVED AND INSTALLED NEW LH OTBD #5 FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR SIMA20210525002Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN AT GATE CABIN ALT INDICATING 500-C/A-LUBRICATED MAIN CABIN DOOR ROLLERS AND PERFORMED OPS CHECK IAW AMM 52-10-01 OPS CHECK GOOD
Back to Embraer EMB-145LR