SDR SIMA20210315002Support · corrodedSSI 53-200-29 TOILET WASTE VALVE SUPPORT IS CORRODED ON EXTERNAL SKIN. CORROSION LEVEL 2-C/A-REMOVED AND REPLACED WASTE VALVE SUPPORT IAW EMB 145 SRM 51-40-02SDR SIMA20210315001Flashlight · inoperativeFWD FA EMERGENCY FLASHLIGHT INOP-C/A-FLIGHT CREW PLACARDED FWD FA EMERGENCY FLASHLIGHT. M PROCEDURES C/W. MELAUTH# 030204M-CREF# 25-32MOC# 628765SDR HNAA2021031500097Warning Buzzer · false activationCREW CALLED AND STATED ON TAKEOFF ROLL TRIM AURAL SOUNDED AND MASTER CAUTION LIGHT TRIGGERED. THEY ABORTED THE TAKEOFF. NO EICAS MESSAGES DISPLAYED HAD CREW CHECK CMC NO MESSAGES ON CMC. ADVISED CREW TO RECHECK ALL T/O SETTINGS. HISTORY: NO HISTORY IN 30 DSDR HNAA2021031500096Unknown · odorPDIS 602 21-01 2179641 13MAR21 ORD CLOSE
FUMES SMELLED IN FLIGHT DECK DURING TAXI TO GATE
FACT 13MAR21 20:49 ORD
INSPECTED BOTH PACK SYSTEMS FOR ANY OBVIOUS DEFECTS. NO DEFECTS FOUND. PERFORMED OPS CHECK OF BOTH SYSTEMS WITH CRSDR HNAA2021033000108Angle · corrodedCARGO DOOR LOWER INNER ANGLE HAS CORROSION AROUND NUT PLATE HOLES...REMOVED AND INSTALLED SERVICEABLE CARGO
DOOR LOWER INNER ANGLE IAW EMB 145 SRM 51-40-02.SDR HNAA2021033000107Angle · corrodedCARGO DOOR LOWER INNER ANGLE HAS CORROSION AROUND NUT PLATE HOLES...REMOVED AND INSTALLED SERVICEABLE CARGO
DOOR LOWER INNER ANGLE IAW EMB 145 SRM 51-40-02.SDR HNAA2021031600099Button · faultedMAIN PITCH TRIM INOPERATIVE EICAS MESSAGE DURING CRUISE FLIGHT WITH OUT SELECTING A CHANGE OF TRIM AND A/P ON FO'S SIDE. T/S IN REF TO FIM TASK 27 43 00 STEPS 1-4/10-11. FOUND CONTINUITY DEFECT ON PUSH BUTTON MAIN CUTOUT. R & R THE PUSH BUTTON IAW AMM 20 13 0SDR HNAA2021031600098Control Unit · failedMAIN PITCH TRIM INOP EICAS MESSAGE IN CRUISE FLIGHT WITHOUT SELECTING A CHANGE OF TRIM AND A/P ON FO'S. T/S FOUND HOR STAB CTL UNIT FAILURE TWICE ON MFD, R&R STAB CTL UNIT IAW EMB 145 AMM 27-40-01 NO FIX. REMOVED PANEL 324EL CLEANED CP'S ON STAB ACTUATOR AS RSDR SIMA20210314001Lamp · inoperativeRH EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR RH EXTERIOR EMERGENCY LAMP IAW AMM 33-50-10 OPC GOODSDR HNAA2021033000123Seat Track · corrodedRH#2 LOWER SEAT TRACK HAS CORROSION AND IS GOUGED...RAR RH #2 LOWER SEAT TRACK IAW EMB 145 AMM 53-01-06.SDR HNAA2021033000122Seat Track · corrodedLH #3 LOWER SEAT TRACK HAS CORROSION....RAR LH #3 LOWER SEAT TRACK IAW EMB 145 AMM 53-01-06.SDR HNAA2021033000120Crossbeam · corrodedCENTER AISLE CROSSBEAM AT FRAME 25 HAS SPOT OF CORROSION....RAR FR 25 CENTER AISLE CROSSBEAM IAW EMB-145 SRM 51-40-02 AND PIEDMONT BULLETIN SRM 53-3 R1.SDR HNAA2021033000115Crossbeam · corrodedLH CROSSBEAM AT FR 18 IS CORRODED...REMOVED AND REPLACED THE LH CROSSBEAM AT FR18 IAW EMB 142 SRM 51-40-02 AND EMB 145 SRM 53-21-10 AND PIEDMONT BULLETIN NUMBER 53-3 R1.SDR HNAA2021033000113Door Sill · corrodedSERVICE DOOR FWD SILL IS CORRODED AT AFT SCREW HOLE....REMOVED SERVICE DOOR FWD SILL, REMOVED SERVICE DOOR FWD SILL FR-20 T BRACKET TO FOM. INSTALLED SERVICEABLE SERVICE DOOR FWD SILL AND INSTALLED SERVICE DOOR FWD SILL FR-20 T BRACKER AFTER MTX IAW EMB 145 SRSDR SIMA20210313001Light · inoperativeCOCKPIT OVERHEAD EMERGENCY LIGHT INOP-C/A-RAR COCKPIT OVERHEAD EMERGENCY LIGHT IAW EMB AMM TASK 33-50-05-000-801-A AND TASK 33-50-05-400-801-A. OPC GOODSDR SIMA20210312002Light · detachedLH EMERGENCY FLOOR PATH LIGHT STRIP HAS BROKEN OFF WIRES AT BASE-C/A-COMPLETE:RAR #8 LH EMERGENCY FLOOR PATH LIGHT STRIP IAW AMM 33-50-12. OPS CK GOODSDR HNAA2021033000121Gusset · corrodedLH OMEGA BEAM GUSSET HAS CORROSION BETWEEN FRAMES 33-35....REMOVED CORRODED AND INSTALLED NEW L/H OMEGA BEAM GUSSET BETWEEN FRAMES 29-36 IAW EMB 145 SRM 51-40-02.SDR HNAA2021033000119Floor Support · corrodedRH #1 OUTBD FLOOR SILL IS CORRODED....BLENDED OUT RH #1 OUBD FLOOR SILL, SILL FOUND TO BE OUTSIDE OF EMB 145 SRM 53-22-10 LIMITS. REMOVED, DRILLED, INSTALLED AND PAINTED NEW RH #1 OUTBD SILL IAW EMB 145 SRM'S 51-40-02, 51-20-03, EMB 145 CPM 51-21-06 AND PIEDMOSDR HNAA2021033000118Floor Support · corrodedRH #2 OUTBD FLOOR SILL CORRODED....REMOVED AND REPLACED RH #2 OUTBD FLOOR SILL IAW EMB 145 SRM 51-40-02. SEE WIPS AND TASKS FOR DETAILSSDR HNAA2021033000112Gusset · corrodedLH OMEGA BEAM GUSSET IS CORRODED AROUND 2 SCREW HOLES BETWEEN FR 60-61.... REMOVED AND REPLACED LH OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02SDR HNAA2021033000111Gusset · corrodedRH OMEGA BEAM GUSSET IS CORRODED AROUND AFT SCREW HOLE AND UNDER POTABLE WATER NIPPLES....R&R RH OMEGA BEAM GUSSET IN LAV AT FR 60.SDR HNAA2021033000110Floor Support · corrodedRH OUTBD FLOOR SILL IS CORRODED UNDER CARBON CROSSBEAM BETWEEN FR 60-61....RAR RH FWD OUTBD CARGO FLOOR SILL IAW EMB-145 SRM 51-40-02. SEE TURNOVER FOR DETAILS.SDR SIMA20210312001Sleeve · damagedBLEED 2 LEAK IN FLIGHT DECLARED EMERGENCY EQUIPMENT SWAP FLT CONT. -C/A-RAR Y-DUCT, SLEEVES AND CLAMPS AT RH PACK.IAW REF ETN-EM-21-056. PERFORMED OPC IAW AMM EMB 145 21-51-00. OPC GOOD. NO DEFECT NOTED. IN REF WITH 21-60-01.SDR SIMA20210311001Angle · damagedAFT BAGGAGE DOOR FORWARD (ANGLE-EXTRUSION) CONTINUOUS STOP IS DAMAGED ON LOWER END.-C/A-REPAIRED BAGGAGE DOOR FWD CONTINUOUS STOP ANGLE IAW SRM 52-30-02.SDR HNAA2021033000109Floor Support · corrodedREMOVED CORRODED RH #4 OUTBD FLOOR SILL POSITIONED DRILLED AND INSTALLED SERVICEABLE FLOOR SILL IAW EMB 145 SRM 51-20-03, 51-40-02. (SEE WIPS AND TASKS FOR DETAILS.)SDR HNAA2021033000106Support · corrodedTOILET WASTE VALVE SUPPORT IS CORRODED AT EXTERNAL SIDE...RAR WASTE VALVE SUPPORT IAW EMB 145 SRM 51-40-02 & EMB 145 SRM 51-40-09.SDR SIMA20210310002Cradle · brokenFWD CABIN EMERGENCY FLASH LIGHT HOLDER BROKEN. DEFERRED PER MEL 25-32 FWD CABIN EMERGENCY FLASHLIGHT HOLDER M PROCEDURE COMPLIED WITH-C/A-THIS IS A SUPPLEMENTAL-RAR FWD CABIN FLASHLIGHT ASSY IAW AMM 33-50-16.OPS CHECK GOOD.MEL RESTORED.SDR SIMA20210310003Inverter · inoperativeBOTH FLOOR EMERGENCY EXIT LIGHTS INOP-C/A-RAR #5 EMERGENCY LIGHT INVERTER OPS CHECK GOOD IAW EMB AMM 33-50-11SDR SIMA20210310001Cradle · brokenFA EMETRGENCY FLASHLIGHT HOLDER BROKEN-C/A- RAR FWD FA EMERGENCY FLASHLIGHT ASSY IAW ETN-EM-33-059SDR SIMA20210309001Light · damagedR/H #1 AND #8 EMERGENCY LIGHT EXTRUSION DAMAGED.-C/A-COMPLETE:INSTALLED NEW R/H #1 AND #8 EMERGENCY LIGHT EXTRUSION IAW EMB 145 AMM 33-50-12.SDR HNAA202103100009Clamp · looseFOUND MULTIPLE V BAND CLAMPS IN LH PYLON AROUND PRECOOLER AND MULTIPLE CLAMPS IN LH PACK AREA TO BE LOOSE. RE TORQUED CLAMPS IRW E145 AMM 20-10-01. OPS CHECK IRW E145 AMM 36-00-00. NO LEAKS OR MESSAGES. OPS CHECK GOOD.SDR HNAA2021031000095Warning Message · illuminatedBLEED 1 LEAK EICAS MSG DISPLAYED C/W RMM 36-11-05. LEFT ENG BLEED INOP WITH APU BLEED AIR CURRENTLY ON THE MEL. OPENSDR HNAA2021033000125Trunnion · corrodedNLG LEG LH TRUNNION FITTING HAS A DEEP GROVE WITH PITING ON BEARING HOUSING...BLENDED PITTING WITH DEEP GROVE ON BEARING HOUSING ON NLG LEG L/H TRUNNION FITTING IAW EMB 145 SRM 51-10-03 AND FOUND TO ACCEPTED FOR CONTINUED SERVICE FOR 5000 F/C'S IAW ETD2021-145SDR SIMA20210308001Light · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EXTERNAL EMERGENCY LIGHT IAW EMB AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECK GOOD. NO DEFECTS NOTED. END.SDR HNAA2021030800094Unknown · odorPDIS 683 21-01 2532571 08MAR21 FLO ASSGN
PACK 2 OVERHEAT WITH BURNING SMELL IN COCKPIT AND TR
OUBLE COOLING A/C. BURNING SMELL ALSO NOTICED WITH O
NLY PACK 1 RUNNING (NOTE: CREW STATED IT TAKES RUN
NING 3 MINS BEFORE SMESDR HNAA2021030800093Unknown · odorPDIS 643 21-51 2409671 07MAR21 CLT CLOSE
FOUL SMELL FROM BLEED SYSTEM
FACT 07MAR21 12:35 CLT
TROUBLE SHOT SMELL IN BLEEDS IN REF TO FIM 21-20-00-810-801-A FOUND NO DEFECTS AT THIS TIME OK FOR SERVICE.SDR SIMA20210305001Shear Tie · corrodedCARGO DOOR CUTOUT SHEAR CLIP CORRODED IN PREVIOUS BLENDED (BLUE PAINT) AREA AT FR 68 JUST ABOVE CARGO DOOR SILL.CORROSION LEVEL 1-C/A-PERFORMED PERMANENT REPAIR TO FR 68 SHEAR CLIP JUST ABOVE CARGO DOOR SILL IAW EMB 145 SRM 53-21-04-RE ITEM 4.SDR HNAA2021030800092Pedal · looseON TAKEOFF ROLL AIRCRAFT VEERED HARD TO THE RIGHT LEFT HAND RUDDER PEDAL IS ACTUATING THE LEFT BRAKES. CREW REPORTED ABORTED AT 10 KNOTS. PERFORMED OPS CHECK FOR MAIN BRAKE SYS IAW AMM 32-41-00 AND RUDDER SYS CHECK IAW AMM 27-25-00. BOTH CHECKS ARE SATISFACTOSDR HNAA2021030800091Warning Message · illuminatedON TAKEOFF CLIMB AMBER BAG DOOR OPEN CAUTION MESSAGE CREW HEARD WHISTLING NOISE. BAG DOOR WARNING SYSTEM. SUPPLEMENTAL INFORMATION WILL FOLLOW, CURRENTLY ON THE MELSDR HNAA2021030800090Dau · faultedENG 1 REV DISAGREE DISPLAYED ON EICAS. T/S ENG 1 REV DISAGREE MESSAGE IAW FIM 78-34-00-810-803-A. FOUND ENG1 T/R ICU VLV FAIL MESSAGE ON CMC. T/S IAW FIM 78-30-00-810-814-A STEPS 1-3. R&R'D DAU2 IAW AMM 31-41-01-04. UNINHIBITED T/R AND ICU 1. OPS CK GOOD. OKSDR HNAA2021030700089Relay · malfunctionedNR 1 ENGINE THRUST REVERSER DISAGREE MESSAGE ON TAKE OFF ROLL (C/W TASK 78-31-01-980-801-A). REACTIVATED ICU AND REMOVED LOCK PINS. T/S E1 REV DISAGREE MSG IAW FIM 78-34-00-810-803A. R&R'D RELAYS KO641,K0397,AND K0323 IAW SWPM 20-13-02. OPS CK OF TR GOOD.SDR HNAA2021030700088Warning Message · false activationSPS 1 INOP ON TAKEOFF ROLL. CMC MSG OF SPC FAIL. CMC MSG SPC FAIL FOLLOWED FIM 27-36-00-810-807-A BLOCK 1 OPS CHECK AMM 27-36-00-700-801-A SPS OPS CHECK GOOD FOUND TO BE TRANSITORY CONDITION. OK FOR SERVICE.SDR SIMA20210303003Fuse · inoperativeBOTH L/H AND R/H AFT EXTERIOR EMERGENCY LIGHTS INOP-C/A-REMOVED AND REPLACED FUSE ON #4 EMERGENCY LIGHT POWER SUPPLY IAW EMB 145 CMM 25-60-03. OPS CHECKED GOOD.SDR SIMA20210303004Light · inoperativeCOCKPIT STEP EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED COCKPIT STEP EXIT IDENTIFIER IAW EMB 145 AMM 33-50-13. OPERATIONAL CHECK GOOD.SDR JJBA20210302050None · noneCENTER FUSELAGE II - EXISTING CIRCLE REPAIR AT FRAME 32-33 AND STRINGERS 6L-7L. REMOVED EXISTING REPAIR AND INSTALLED NEW REPAIR AT CENTER FUSELAGE II FRAME 32-33 AND STRINGERS 6L-7L.SDR SIMA20210302001Unknown · odorFLIGHT ATTENDENT REPORTED BURNING SMELL NEAR ROW 12 SMELL WENT AWAY IN 5 MINUTES-C/A-COMPLIED WITH FIM TASK 21-20-00-810-801-A UP TO STEP 12SDR SIMA20210301004Fitting · gougedR/H AILERON DAMPER FITTING IS GOUGED ON THE AILERON.-C/A-COMPLETE RAR R/H AILERON DAMPER FITTING IAW ENVOY EO EM-27MR-112.SDR SIMA20210301002Wire · damagedSEVENTH EMERGENCY LIGHT STRIP ON LH SIDE FLOOR WIRES DAMAGED, LIGHT INOP-C/A-RAR FLOOR STRIP EMERGENCY LIGHT IAW EMB145 AMM 33-50-12. OPS CHECK GOOD.SDR SIMA20210301001Battery · missingAFT FA FLASHLIGHT NO BATTERY.-C/A-REPLACED AFT EMERGENCY FLASHLIGHT BATTERY IAW AMM CH 33-51-01.SDR HNAA2021030200067Warning System · malfunctionedPDIS 652 31-50 2379262 01MAR21 CLT CLOSE. DURING T/O ROLL AT ABOUT 40 KTS, GPWS, TCAS, TERRAIN INOP EICAS MESSAGES WITH TAKEOFF CONFIG WARNING WITH NO RELATED AURAL WARNING. FACT 02MAR21 09:27 CLT R&R AURAL WARNING UNIT IAW AMM 31-51-400-801-A OP