SDR SIMA2020042819012Connector · missingCABIN FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE/MISSING CONNECTOR AT FR 38-C/A-COMPLETE:REPAIRED EMERGENCY LIGHT STRIP AT FR 38 IAW EMB 145 SWPM 20-21-00. EASI #6277 AND #6224H.. SEE THIS NRTC FOR ALL WIP AND TASK DETAILSSDR SIMA2020042819011Light · brokenL/H #6 EMERGENCY LIGHT STRIP BROKEN .-C/A-COMPLETE:REMOVED AND REPLACED BROKEN L/H #6 EMERGENGY LIGHT STRIP IAW EMB 145 AMM 33-50-12. SEE BOW341052 FOR RE-INSTALLATION AND OPS CHECK .SDR SIMA2020042819010Light · inoperativeL/H # 1 EMERGENCY LIGHT INOP .-C/A-COMPLETE:REMOVED AND REPLACED L/H # 1 EMERGENCY LIGHT IAW EMB 145 AMM 33-50-12. OPS CHECKED GOOD .SDR SIMA2020042819009Wire · brokenL/H #8 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE .-C/A-COMPLETE:REMOVED AND REPLACED CORRECTART # FOR L/H #8 LIGHT STRIP IAW EMB 145 AMM 33-50-12. OPS CHECKED GOOD .SDR SIMA2020041319008Structure · corrodedLAV BUCKET INSIDE WASTE PANEL HAS CORROSION-C/A-APPLIED SEALANT AND INSTALLED SERVICEABLE LAV BUCKET IAW EMB 145 SRM 51-20-01 AND 51-40-02.SDR HNAA2020040700121Shear Tie · corrodedSSI 53-30-03. FRAME 65 SHEAR CLIP CORRODED. REPAIRED IAW EO1-53-20-0138.SDR HNAA2020040700120Fitting · crackedLEFT HAND ENGINE PYLON FORWARD YOKE LOWER FORWARD FITTING CRACKED. REPAIRED IAW ETD2020-145-009605 AND EO1-54-20-0147.SDR SIMA2020040619007Door Sill · corrodedSSI 53-30-48 CARGO DOOR LOWER SILL IS CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA2020032019002Acm · malfunctionedSUPPLEMENTAL PACK #2 HAS A VERY UNUSUAL NOISE AND WAS FILLING THE CABIN WITH A BURNING TYPE ODOR-C/A-VERIFIED NOISE COMING FROM PACK #2 PERFORMED ENGINE RUN WITH CREW INDICATING PACK #1 NO SMELL NOTED. DEFERRED PACK #2 SYSTEM AUTH 030559D-C REF 21-30. COMPLIEDSDR SIMA2020032019001Battery · dischargedCABIN EMERGENCY LIGHT ON AND OFF INTERMITTENTLY-C/A-RAR BATTERY POWER SUPPLY #4 IAW AMM 33-50-04. REMOVED AND REPLACED BATTERY #4 IAM AMM 33-50-04. REMOVED AND REPLACED INVERTER #6 IAW AMM 33-50-11 SYSTEM OPS CHECK GOOD IAW AMM 33-50-00. OK FOR SERVICE. EMERGESDR SIMA2020061118009Light · damagedEMERGENCY LIGHT NR 8 EXTRUSION DAMAGED. REMOVED AND REPLACED EMERGENCY LIGHT NR 8 EXTRUSION, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR SIMA2020061118010Structure · corrodedCOCKPIT UNDERFLOOR BETWEEN FRAMES 13 AND 14 AND STRINGERS 20R AND 18L HAS SURFACE CORROSION. C/W REPAIR IAW ERS-EM-53MR-3758 PART B. TDMI RESTORED.SDR SIMA2020061118011Light · damagedRT EXTRUSION NR 4 DAMAGED. REMOVED AND REPLACED RT EXTRUSION NR 4, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR SIMA2020061118012Light · damagedRT EXTRUSION NR 7 DAMAGED. REMOVED AND REPLACED RT EXTRUSION NR 7, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR SIMA2020061118013Light · damagedRT EXTRUSION NR 6 DAMAGED. REMOVED AND REPLACED RT EXTRUSION NR 6, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR SIMA2020061118014Light · damagedEMERGENCY LIGHT NR 1 EXTRUSION DAMAGED. REMOVED AND REPLACED EMERGENCY LIGHT NR 1 EXTRUSION, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR SIMA2020061118008Light · damagedEMERGENCY LIGHT NR 5 EXTRUSION DAMAGED. REMOVED AND REPLACED EMERGENCY LIGHT NR 5 EXTRUSION, IAW AMM 33-50-12. REFERENCE BOW342807 FOR INSTALLATION.SDR ASOA2020052783044Drag Angle · crackedDURING C CHECK INSPECTION FOUND VERTICAL STABILIZER DRAG ANGLE CRACKED AT FASTENER ON RT SIDE JUST AFT OF PRESSURE BULKHEAD. MAINTENANCE REPAIRED IAW SRM 53-31-02 AND SRM 51-40-02.SDR SIMA202003198003Flashlight · brokenSUPPLEMENTAL AFT CABIN FLASHLIGHT BROKEN-C/A-FLIGHT CREW PLACARD AFT CABIN FLASHLIGHT AUTH 030546-C REF - 25-53 MOC 864015. REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW EMB 145 AMM 33-50-16 OPS CHECK GOOD . MEL ITEM RESTOREDSDR HNAA2020032000099Unknown · malfunctionedPDIS 658 21-32 2157674 19MAR20 CLT CLOSE
ON CLIMB-OUT CREW FOUND EICAS WAS SHOWING AMBER DASH
LINES ON RATE AND CABIN ALTITUDE.
24853 00 CFG
FACT 19MAR20 14:07 CLT
PWR DOWN PSDR HNAA2020032000100Control Unit · malfunctionedPDIS 639 27-41 2161322 18MAR20 PHL CLOSE
MAIN PITCH TRIM INOP ON EICAS DURING FLIGHT
24848 00 MDC
FACT 18MAR20 11:34 PHL
REMOVED AND REPLACED HORIZONTAL STAB CONTROL UNIT IA
SDR HNAA2020032000097Unknown · malfunctionedPDIS 665 27-51 2184402 18MAR20 CLT CLOSE
WHEN SELECTING FLAPS TO 9 DEGREES, THEY REMAINED AT
0 DEGREES. NO ASSOCIATED EICAS MESSAGES.
18544
FACT 18MAR20 18:07 CLT POWERED DOW AND POWERED UPSDR SIMA202003198002Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR HNAA2020040700119Door Frame · chafedCARGO DOOR WEB FRAME HAS 2 CHAFES AND ONE HOLE. REPAIRED IAW EO1-52-20-0141.SDR SIMA202003187001Light · inoperativeLH FUSELAGE AFT EMERGENCY LAMP INOP-C/A-REMOVED AND REPLACED LH FUSELAGE AFT EMERGENCY LAMP, OPC GOOD IAW EMB AMM 33-50-10.SDR HNAA2020041510140Shear Tie · corrodedSSI 53-30-48 SHEAR CLIP AT FRAME 68 BY CARGO DOOR SILL IS CORRODED...REPAIR ACCOMPLISHED IAW EMB 145
SRM 53-31-04 ITEM 4 FIGURE 212 AND PIEDMONT
EO1-53-20-0171.FR 68 SHEAR CLIP PN: 145-25369-003.SDR HNAA2020041500139Shear Tie · corrodedSSI 53-30-48 SHEAR CLIP AT FRAME 65 BY CARGO DOOR SILL IS CORRODED...REMOVED AND INSTALLED NEW SECTION
OF SHEAR CLIP AT FRAME 65 IAW EMB 145 SRM 53--
31-04 EO1-53-20-0160SDR HNAA2020041500138Rib · crackedRH WING RIB 21 IS CRACKED...ACCOMPLISHED WITH REPAIR AT RH WING
RIB 21 IAW EMB 145 SRM 57-20-07.SDR HNAA2020040700124Frame · crackedFRAME 73 IS CRACKED BETWEEN STR 17R-16R. REMOVED AND REPLACED FRAME 73 LOWER SECTION IAW SRM 51-40-02.SDR ASOA2020040363030Profile · gougedDURING C CHECK INSPECTION FOUND LEFT OVERWING EMERGENCY HATCH AFT FRAME PROFILE GOUGED. MAINTENANCE REPLACED LEFT OVERWING EMERGENCY HATCH AFT FRAME PROFILESDR SIMA202003176001Charger · failedSERVICE DOOR EMERGENCY EXIT LIGHT INOP-C/A- T/S FOUND EMERGENCY BATTERY NOT WORKING REMOVED AND REPLACED EMERGENCY BATTERY #2 AND CHARGER IAW ENVOY W/C 33-700-19 OPC GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 104854SDR HNAA2020041500137Web · gougedCARGO DOOR WEBBING IS GOUGED AT PREVIOUS REPAIR...INSTALLED SERVICEABLE REPAIR DOUBLER IAW EMB
145 SRM 52-30-01, ITEM 12, FIG. 213.SDR HNAA2020041500136Rib · crackedLH WING RIB 21 IS CRACKED......ACCOMPLISHED REPAIR ON L/H WING
RIB 21 IAW EMB 145 SRM 57-20-07.SDR HNAA2020040700126Door Sill · corrodedSSI 53-20-11 SERVICE DOOR CENTER SILL IS CORRODED AROUND FORWARD AND CENTER SCREW HOLES. INSTALLED NEW SERVICEABLE SERVICE DOOR CENTER SILL IAW SRM 51-40-02.SDR SIMA2020031615004Light · inoperativeDURING PS-1 CHECK FOUND EXTERNAL LH EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED EXTERNAL LH EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10SDR SIMA2020031615001Light · inoperativeDURING PS-1 FOUND RH SIDE CENTER FAIRING EMER. LIGHT INOP-C/A-REMOVED AND REPLACED RH SIDE CENTER FAIRING EMER. LIGHT IAW EMB 145 AMM 33-50-10. OPS CHECK GOODSDR HNAA2020041500135Skin · crackedRH FR. 75 AREA HAS A SKIN CRACK ABOVE STR., 2R MARKED, SETTINGS: FREQ.
400KHZ, ANGLE: 291.1 DEG., H-61.3DB., V-77.6DB., FILTER: LO-PASS 500HZ.,
PROBE: 100-500KHZ....ACCOMPLISHED REPAIR OF FUSELAGE SKIN AT FR 75
STGR 2R IAW EMB 145 SRM 53-31-01 AND EO1-53-20SDR ASOA2020040343029Rib · crackedDURING C CHECK INSPECTION FOUND LEFT WING RIB 21 CRACKED. MAINTENANCE REPAIRED LEFT WING RIB 21 I/A/W SRM 57-20-07.SDR SIMA2020031614001Actuator · faultyLG AIR/GROUND FAIL DURING GEAR EXTENSION ON FINAL, WENT AROUND AND IT DISAPPEARED AT 2500 MSL. 2ND ATTEMPT , EXTENDED GEAR AND INDICATION RETURNED SO WE DECLARED AN EMERGENCY AND LANDED. IT ONCE AGAIN WENT AWAY AT 700 FT AGL THIS TIME.-C/A-REMOVED AND REPLACEDSDR SIMA2020031614003Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD. END.SDR SIMA2020031613002Flashlight · inoperativeSUPPLEMENTAL AFT FLIGHT ATTENDEANT FLASHLIGHT INOP.-C/A-DEFERRED PER MEL 25-53. AUTH #030415-C. REMOVED AND REPLACED AFT FA FLASHLIGHT IAW AMM 33-50-16 AND ETN- EM-33-059. OPS CHECK GOOD. MEL ITEM RESTOREDSDR ASOA202003147028Wire Harness · faultyENG 1 NO DISPATCH ON TAKEOFF ROLL APPROX 30 KNOTS. NO TAKEOFF CONFIGURATION WARNING PRESENTED MOMENTARILY ON THE ABORT AFTER THRUST LEVERS PULLED BACK. REMOVED AND REPLACED EXTERNAL FADEC HARNESS A&B. OPS CHECKED GOOD. AIRCRAFT RELEASED AND RETURNED TO SERVICESDR HNAA2020040700116Housing · corrodedSPHERICAL BEARING HOUSING ON LH AND RH SIDES HAS CORROSION. REPAIRED SPHERICAL BEARING HOUSING CORROSION ON LH AND RH SIDES IAW PIEDMONT EO1-55-20-0131.SDR SIMA2020031312002Inverter · failedFLOOR EMERGENCY LIGHT STRIP INOP #1-C/A-REMOVED AND REPLACED INVERTER OVER SERVICE DOOR IAW 33-50-11 OPS CHECK GOODSDR SIMA2020031312003Light · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED MAIN DOOR EXTERNAL EMERGENCY LIGHT IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA2020042111004Wire · broken1EA PROX LIGHT WITH ARROWS HAS BROKEN WIRES-C/A-COMPLETE:REMOVED AND REPLACED 1EA PROX LIGHT WITH ARROWS IAW EMB 145 AMM 33-50-12 SEE NRTC BOW340840 FOR FINAL INSTALL AND OPS CHECKSSDR SIMA2020042111005Connector · disconnectedLH OVERWING EXIT DOOR SMALL "EXIT" LIGHT IS INOP-C/A-COMPLETE:CONNECTED LH OVERWING EXIT DOOR SMALL EMERGENCY LIGHT CANNON PLUG/CONNECTOR IAW EMB 145 SWPM 20-50-00 AND AMM 33-50-00. OPS CHECK GOOD.SDR SIMA2020042111007Floor Support · crackedRH FLOOR SUPPORT AT FR 68 IS CRACKED-C/A-COMPLETE:REMOVED AND REPLACED RH FLOOR SUPPORT AT FR 68 IAW EMB 145 SRM 51-40-02.SDR SIMA2020042111006Connector · not seatedR/H OVERWING EMERGENCY LIGHT IS INOP.-C/A-COMPLETE:RE-SEATED CANNON PLUG TO R/H OVERWING EXTERIOR EMERGENCY LIGHT IAW EMB 145 SWPM 20-50-00 AND AMM 33-50-00. OPS CHECK GOOD.SDR ASOA2020031614005Bar · looseSDF - FLIGHT 4448 THE REW REPORTED THAT WHEN APU STARTED WITH THE ENGINES RUNNING HEARD A LOUD CRACKLING AND SMELL OF BURNT ELECTRICAL, ALSO HAPPENED DURING ENGINE SHUT DOWN. THE AIRCRAFT LANDED AT SDF WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT