SDR SIMA202002241002Door · out of adjustCANNOT OPEN MAIN CABIN DOOR FROM OUTSIDE-C/A-INSPECTED MAIN CABIN DOOR FOUND TOP BRACKET HITTING WHEN DOOR IS CLOSING DESC REMAINS OPEN. ADJUSTED PASSENGER DOOR IAW AMM 52-18-00, RECORDED A OUT OFF DOCK VALE OF 30 LBS TO OPEN THE DOOR WHICH IS WITH IN LIMITSSDR SIMA2020030420005Frame · crackedFR25 IS CRACKED BETWEEN STR 16R-15R-C/A-INSTALLED SPLICE REPAIR ON FR25 BETWEEN STR16R-15R IAW EMB 145 SRM 53-00-04SDR SIMA202002210003Light · inoperativeCENTER ISLE EXIT LIGHT INOP-C/A-REPLACED CENTER ISLE EXIT LIGHT IAW AMM 33-50-15-04 OPS CHECK GOODSDR SIMA2020029007Yoke · crackedRIGHT FWD PYLON LOWER YOKE WAS CRACKED. REMOVED AND INSTALLED SERVICABLE YOKE IAW ERS-EM-54MR-698.SDR SIMA2020030519011Door Sill · corrodedCENTER SERVICE DOOR SILL IS CORRODED-C/A-COMPLETED INSTALLATION OF SERVICE DOOR SILL IAW SRM 51-40-02, RESTORED SURFACE PROTECTION IAW CPM 51-21-06.SDR SIMA2020030519012Support Bracket · crackedBAGGAGE DOOR LIFTING/LOWERING MECH AFT LOWER SUPPORT BRACKET IS CRACKED.( APPROX 1" LONG) -C/A-REPLACED BAGGAGE DOOR LIFTING/LOWERING MECH AFT LOWER SUPPORT BRACKET IAW SRM 51-40-02.SDR SIMA202003029006Door Sill · corrodedCARGO DOOR CUTOUT SILL IS CORRODED.-C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW SRM 51-40-02. RESTORED SURFACE PROTECTION IAW CPM 51-21-06.SDR SIMA202003029007Yoke · crackedRH FWD PYLON LWR YOKE CRACKED-C/A-REMOVED AND INSTALLED SERVICABLE YOKE IAW ERS-EM-54MR-698SDR SIMA202002918004Fitting · crackedLH ENGINE FWD YOKE LWR FWD FITTING CRACKED. REMOVED AND INSTALLED A SERVICABLE LT FWD YOKE LWR FWD FITTING IAW EO ERS-EM-54MR-698.SDR ASOA2020022085008Unknown · odorPILOT REPORTED CONTACTORS TICKING BY THE FO'S SIDEWALL. SLIGHT SMELL ASSOCIATED. MX PERFORMED INSPECTION ON RIGHT SIDE RELAY SUPPORT NO SIGN OF BURN OR BURN SMELL. ALL RELAYS LOOK NORMAL AND CLEAN. A/C APPROVED FOR RETURN TO SERVICE.SDR SIMA202002198002Lamp · inoperativeOVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED OVRWING EMERGENCY LIGHT LAMP I.A.W. 33-50-10. OPS GOOD. NO FUTHER DEFECTD NOTED.SDR SIMA20200218001Fitting · crackedDURING HMBV INSPECTION, QC FOUND LH PYLON FWD LOWER YOKE FITTING CRACKED.-C/A-REMOVED AND REPLACED YOKE FITTING IAW ERS-EM-54MR-698.SDR HNAA2020021800076Floor Support · crackedAFTER REMOVAL OF RH OTBD FLOOR SILL #1 FOUND FR 25 CRACKED
AT ATTACHMENT POINT
COMPLETE: REPAIRED FR 25 CRACK AT ATTACHMENT
POINT IAW PIEDMONT EO1-53-20-0070.
SEE TASK AND WIP ENTRIES FOR DETAILS.SDR HNAA2020021800075Floor Support · corrodedLAVATORY RH OMEGA BEAM HAS CORROSION
COMPLETE: REPAIRED LAVATORY RH OMEGA
BEAM CORROSION IAW PIEDMONT EO1-53-20--
0080. SEE TASK AND WIP ENTRIES FOR DETAILS.SDR HNAA2020021800074Frame · corrodedSSI 53-20-43 CORROSION ON FRAME 22 BETWEEN STRINGERS 15R -16R PREVIOUS
REPAIR AT BLUE PAINT
COMPLETE: REPAIRED CORROSION ON FRAME 22 BETWEEN
STRINGERS 15R -16R IAW PIEDMONT EO1-53-20-0081.
SEE TASK AND WIP ENTRIES FOR DETAILS.SDR HNAA2020021800073Frame · crackedFR 66 CRACKED BTW STR 16R-17R.
COMPLETE: REMOVED AND REPLACED FR 66 (LOWER FRAME)
IAW EMB145 SRM 51-40-02 AND SRM 51-20--
01. SEE TASK AND WIP ENTRIES FOR DETAILS.SDR HNAA2020021800072Shear Tie · corrodedSHEAR CLIP AT FR 65 STR 15L-18L CORRODED.
COMPLETED INSTALL OF THE NEW SHEAR CLIP AT FR
65 STR 15L-18L IAW EMB 145 SRM 53-31-04SDR HNAA2020021800071Web · chafedBAGGAGE DOOR LOWER INNER WEB CHAFED BTW VB1-2 AT HB3.
COMPLETE: REPAIRED BAGGAGE DOOR LOWER INNER WEB
CHAFED BTW VB1-2 AT HB3 IAW PIEDMONT EO1-52--
20-0067. SEE TASK AND WIP ENTRIES FOR DETAILS.SDR HNAA2020021800070Web · chafedBAGGAGE DOOR LOWER INNER WEB CHAFED BTW FWD LATERAL FRAME AND VB1 AT HB4.
COMPLETE: REPAIRED BAGGAGE DOOR LOWER INNER WEB
CHAFED BTW FWD LATERAL FRAME AND VB1 AT HB4 IAW
PIEDMONT EO1-52-20-0066. SEE TASK AND WIP ENTRIES
FOR DETAILS.SDR SIMA2020040617005Crossbeam · corrodedCABIN CROSSBEAM BETWEEN FRAMES 24-25 HAS CORROSION.-C/A-COMPLETE:REMOVED AND REPLACED CABIN CROSSBEAM BETWEEN FRAMES 24-25 IAW ETN-EM-53-139SDR SIMA2020040617009Light · damagedLH FLOOR EMERGENCY LIGHT STRIP EXTRUSIONS #3,AND #8 ARE DAMAGED-C/A-COMPLETE:REPLACED LH FLOOR EMERGENCY LIGHT STRIP EXTRUSIONS #3,AND #8 IAW AMM 33-50-12SDR SIMA2020040617007Light · inoperativeLH FLOOR EMERGENCY LIGHT STRIP #8 EXTRUSION ARE DAMAGED-C/A-COMPLETE:REPLACED #8 LH FLOOR EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12.SDR SIMA2020040617004Splice · inoperativeRH LATERAL WING-TO-FUSELAGE 194BR ACCESS PANEL EXTERNAL EMERGENCY LIGHT WILL NOT ILLUMINATE.-C/A-COMPLETE:REPLACED SPLICE 8930, OVERWING EMERGENCY LIGHT TEST GOOD IAW AMM 33-50-00SDR SIMA2020040617006Light · damagedEMERGENCY FLOOR LIGHTING LH EXTRUSION FOR RAMP PANEL IS DAMAGED.-C/A-COMPLETE:REMOVED AND REPLACED EMERGENCY FLOOR LIGHTING LH EXTRUSION FOR RAMP PANEL IAW AMM 33-50-12.SDR SIMA2020040617008Light · corrodedFORWARD BELLY FAIRING, LH EXTERIOR EMERGENCY LIGHT CORRODED.-C/A-COMPLETE:RRMOVED AND REPLACED RETAINER RING IAW SRM 51-40-02SDR SIMA202003027003Skin · gougedCARGO DOOR INNER LWR SKIN SECTION HAS MULTIPLE GOUGES AND CORRODED FASTENER HOLE-C/A-REPAIRED BAGGAGE DOOR INNER LWR SKIN SECTION INSTALLED DOUBLER IAW EMB 145 SRM 52-30-01SDR SIMA202002187001Wire · brokenFOUND WIRE BROKEN ON #3 FLOOR EMERGENCY LIGHT STRIP-C/A-REMOVED AND REPLACED #3 FLOOR EMERGENCY LIGHT STRIP IAW AMM 33-50-12. OPC GOODSDR HNAA2020021800069Skin · dentedDMT 40 - ACCOMPLISH PERMANENT REPAIR OF DENT IN LH FORWARD FUSELAGE NEAR ACCESS DOOR 123BL BETWEEN FR 8 AND 9,SL18L-19L COMPLETE: ACCOMPLISHED PERMANENT REPAIR OF DENT IN LH FORWARD FUSELAGE NEAR ACCESS DOOR 123BL BETWEEN FR 8 AND 9, SL18L-19L IAW PIEDMONT ESDR HNAA2020021800068Unknown · unknownPDIS 631 27-11 2232271 17FEB20 MDT CLOSE
ABOVE 250KNOTS A/C HAD SIGNIFICANT RIGHT ROLLING TENDENCY ALONG WITH MINIMAL ARTIFCIAL AILERON FEEDBACK. SLIGHT BANK INPUTS LED TO LARGE AIILERON BANK OUTPUT
FACT 18FEB20 05:06 MDT
PERFOSDR SIMA202002176003Bulb · inoperativeUPPER LH EMERGENCY LIGHT ON THE EXTERIOR OF A/C FOUND INOP-C/A-REMOVED AND REPLACED OF LIGHT BULB IN UPPER LH EXTERIOR OF A/C IAW EMB145 AMM 33-50-11. OPS CHECK GOOD EMERGENCY LIGHT OPERATIVESDR SIMA20200216001Warning Message · false activationIN CLIMB BLD 1 LEAK EICAS WARNING MESSAGE IN ICING CONDITIONS-C/A-RETORQUED VBAND CLAMPS ON #1 ENG. PRECOOLER IAW AMM 20-10-10 AND AMM 36-11-04. PERFORMED AIR BLEED SYS. OPS CHECK IAW AMM 36-00-00. OPS CHECK GOOD. PERFORMED ICE/RAIN PROT. OPS CHECK IAW AMM 30-SDR HNAA2020021700067Warning Message · illuminatedPDIS 626 78-33 2287121 16FEB20 PHL ASSGN
E1 REVERSE DISAGREE EICAS MESSAGE
SYSTEM IS CURRENTLY ON THE MELSDR SIMA202002175002Charger · failedLEFT FWD EXT EMERGENCY LIGHT INOP-C/A-REPLACED THE LEFT FWD EXTERIOR EMERGENCY LIGHT ASSY IAW AMM 33-50-07. NO FIX. REMOVED AND REPLACED #1 EPSU AND BATTERY IAW AMM 33-50-04 OPC GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 80809SDR HNAA2020021700066Trim System · malfunctionedPDIS 600 27-41 2110041 15FEB20 PHL CLOSE
PITCH TRIM MAIN INOP ON EICAS DURING CLIMB WITH AUTO
PILOT ENGAGED
FACT 15FEB20 14:27 PHL
RESET PITCH TRIM 1/ PITCH TRIM 2 CB PER FIM 27-43-00-810-801-A BLOCK 1. PERFORMED HORIZONSDR SIMA2020033014004Crossbeam · corrodedCROSSBEAM AT FR 20 IS CORRODED.-C/A-COMPLETE:REMOVED AND REPLACED CROSSBEAM AT FR 20 IAW EMB145 SRM 51-40-02, ETN-EM-53-139SDR SIMA2020032714003Crossbeam · corrodedCROSSBEAM BETWEEN FR 24-25 IS CORRODED.-C/A-COMPLETE:REMOVED AND REPLACED CROSSBEAM BETWEEN FR 24-25 WITH SERVICEABLE PART IAW EMB 145 SRM 51-40-02SDR SIMA2020032714002Wire · brokenL/H EMERGENCY LIGHT STRIP #4 HAS A BROKEN WIRE.-C/A-COMPLETE:REPAIRED BROKEN WIRE ON #4 EMERGENCY LIGHT STRIP IAW EMB 145 SWPN 20-21-00. SEE E770710 FOR OPC OF EMERGENCY LIGHTINGSDR SIMA202002184001Window Frame · crackedSUPPLEMENTAL FOUND CRACK ON AFT UPPER SIDE OF RH DV WINDOW FRAME. THIS HAS BEEN UPGRADED TO A MAJOR REPAIR.-C/A-REPAIRED CRACK ON AFT UPPER SIDE OF RH DV WINDOW FRAME IAW ERS-EM-53MR-4037 PART A. ( THERE WAS NO DECLARED EMERGENCY)SDR HNAA2020021700065Computer · malfunctionedPDIS 645 31-50 2130021 14FEB20 CLT CLOSE
AFTER TAKEOFF, TAKEOFF CONFIG TRIM AURAL WARNING, WA
RNING STOPPED BY ITSELF. NO EICAS MESSAGES. TRIM IND
ICATIONS WITHIN RANGE.
FACT 14FEB20 16:39 CLT
R&R AURAL WARNING COSDR SIMA202002143002Light · inoperativeDURING PS-1 CHECK FOUND EXTERNAL LH EMERGENCY LIGHT INOP.-C/A-REMOVED AND REPLACED EXTERNAL LH EMERGENCY LIGHT ASSY IAW EMB 145 AMM 33-50-10. OPS CHECK GOODSDR HNAA2020021400062Clamp · looseMDIS 604 36-21 2292503 13FEB20 ALB CLOSE
WHILE RUNNING ENGINES FOR BLEED OVERTEMP DISCREPANCY
BLEED 1 LEAK MSG ON EICAS
FACT 13FEB20 18:33 ALB
TIGHTEN CLAMPS ON ENGINE BLEED VALVE IAW EMB 145 AMM
36-11-01.SDR HNAA2020021400061Thermostat · failedPDIS 604 36-21 2292501 13FEB20 ALB CLOSE
BLD 1 OVTEMP AT ALTITUDE, IN ICING.
FACT 13FEB20 18:32 ALB
R&R FAN AIR VALVE THERMOSTAT IAW EMB 145 AMM 36-11-0
6 OPS CHECK GOOD OK FOR SERVICESDR HNAA2020021400060Wire · detachedEMERGENCY LIGHT ON MAIN DOOR INOP.... RE-ATTACHED WIRES TO THE ELECTRIC CONNECTORS FOR THE EMERGENCY LIGHT. OPS CHECK GOOD.SDR SIMA20200213001Cable · lack of lubeEMERGENCY PARKING BRAKE DIFFICULT TO SET.-C/A-CLEANED AND LUBED PARKING BRAKE HANDLE / CABLE REF STD MTX PRACTICES.SDR SIMA2020040612007Wire · brokenEMERGENCY LIGHT STRIPS #2 AND #3 HAVE BROKEN WIRES.-C/A-REMOVED AND REPLACED THE EMERGENCY LIGHT STRIPS #2 AND #3. IAW AMM 33-50-12.SDR SIMA2020040612008Wire · brokenEMERGENCY FLOOR LIGHT STRIP #4 HAS A BROKEN WIRE.-C/A-REMOVED AND REPLACED #4 PROX LIGHT STRIP IAW AMM 33-50-12. OPS CK GOODSDR SIMA2020040612006Charger · malfunctionedEMERGENCY LIGHTS FOR BATTERY PACK #3 CAME ON UN COMMANDED.-C/A-COMPLETE:REMOVED AND REPLACED BATTERY CHARGER ASSEMBLY #3 IAW EMB AMM 33-50-04, OPS CHECK GOOD I.A.W. EMB145 A.M.M. 33-50-00-700-801-A.SDR ASOA2020021425007Connector · out of adjustCREW REPORTED EMERGENCY LIGHTS INOP OVER ROW 18. MX ADJUSTED EMERGENCY LIGHT CONNECTOR WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA202002132004Anti-Ice Valve · failedE1 A/ICE FAIL MESSAGE DURING CLIMB. RAN CHECHLIST, BUT MESSAGE REMAINED AND VALVE WOULD NOT OPEN WITH OVERRIDE NOB IN ALL. ALSO GOT AN ENG A/I OVERPRESS ADVISORY MESSAGE.-C/A-DEFFERED PER MEL 30-11 "M" PROCEDURES COMPLIED WITH. REMOVED AND REPLACED E1 ENG PRESDR HNAA2020021400059Light · inoperativeNDIS 649 23-31 0010750 12FEB20 SBY CLOSE
FWD F/A HANDSET/CRADLE EMERGENCY LIGHT INOP.
11412 00 BAD
FACT 12FEB20 11:21 SBY
R&R COCKPIT BULKHEAD ATTN HEADSET IAW AMM 23-31-03.