Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202001064007Light · inoperativeMAIN DOOR EXTERIOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED MAIN DOOR EXTERIOR LIGHT IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. NO FURTHER DEFECTS NOTED. END.SDR SIMA202001064002Actuator · malfunctionedPTRIM MAIN INOP EICAS MESSAGE AFTER TAKEOFF "TRANSFERRED TO NRWC 622-MIA-03884"-C/A-ACCOMPLISHED REMOVED AND REPLACED HORIZONTAL STAB ACTUATOR IAW EMB145 AMM 27-40-02, AND PERFORMED OPERATIONAL CHECKS. OPS CHECK GOOD.SDR SIMA202001064009Light · inoperativeDURING PS-2 CHECK FOUND COURTESY LIGHT INOP AT GALLEY.-C/A-REMOVED AND REPLACED COURTESY LIGHT IAW EMB 145 AMM 33-26-05 OPS CHECK GOODSDR HNAA2020010600010Brake · overheatedNDIS 656 30-21 758 04JAN20 AVP CLOSE
-FOR MIR PURPOSES ONLY-
FACT 04JAN20 14:22 AVP
FLIGHT 4894 ABORTED TAKE OFF DUE TO ONE BRAKE ASSY
TEMPERATURE GOING UP INTO THE YELLOW. AIRCRAFT TAXIED BACK TO THE GATE ALL SDR HNAA2020010600007Pump · leakingPDIS 658 29-13 2122873 04JAN20 PHL CLOSE
HYDRAULIC FLUID LOSS ON SYSTEM 1 FOLLOWED BY HYDRAULIC SYSTEM 1 FAILURE. ( CAPTAIN SAID HYD LOSS WAS GRADUAL, BY THE TIME IT REACHED NEAR AMBER RANGE THEY DECIDED TO DIVERT TO PHL. BY THE TIME THEY
LANDED THESDR HNAA2020010600006Line · leakingNDIS 658 29-13 0008050 04JAN20 PHL CLOSE
HYDRAULIC FLUID LOSS ON SYSTEM 1 FOLLOWED BY HYDRAULIC SYSTEM 1 FAILURE. (CAPTAIN SAID HYD LOSS WAS GRADUAL, BY THE TIME IT REACHED NEAR AMBER RANGE THEY DECIDED TO DIVERT TO PHL. BY THE TIME THEY LANDED THE SSDR ASOA2020010733001Unknown · odorTHE CREW REPORTED BURNT SMELL AT SEAT 9A. MAINTENANCE INSPECTED AND RELEASED AIRCRAFT I/A/W MEL 33-20-00-1. SUPPLEMENT TO FOLLOWSDR SIMA202001063001Tube · chafedOIL LEAK ON #2 ENGINE-C/A-FOUND THE FCDC BYPASS PRESSURE OIL TUBE TO THE ACOC CHAFED. REMOVED AND REPLACED THE ACOC TO THE FCDC PRESSURE LINE IAW RR MM 79-00-00-400-801. LEAK CHECK AND OPS CHECK GOOD.SDR SIMA202001063004Light · damagedFWD, RH PROXIMITY FLOOR STRIP IS DAMAGED.-C/A-REMOVED AND REPLACED RH PROXIMITY STRIP IAW AMM 33-50-12.SDR SIMA202001063003Connector · brokenMOST AFT PROXIMITY FLOOR LIGHT STRIP ELECTRICAL CONNECTOR BROKE OFF WIRING ON A/C SIDE.-C/A-INSTALLED NEW CONNECTOR IAW SWPM 20-50-01, COMPLIED WITH OPS CHECK IAW AMM 33-50-12 OPS CHECK GOOD.SDR HNAA2020010600012Pressure Switch · failedPDIS 691 32-49 2249601 03JAN20 CLT CLOSE
TAKEOFF CONFIG, BRAKES ARE STICKING. ATTEMPTED 6
TIMES.
FACT 03JAN20 18:02 CLT
REMOVED AND REPLACED EMERGENCY PARKING BRAKE PRESSUR
E SWITCH IAW AMM 32-44-07-400-801-SDR HNAA2020010600011Bleed Valve · failedPDIS 626 36-11 2132151 03JAN20 ORF CLOSE
BLEED 2 VLV FAIL EICAS MSG, WING A/ICE FAIL, AND ICE
COND A/ICE INOP. ALL MSGS CLEARED OUT OF ICING. BLE
ED 2 CLOSED REMAINED ON EICAS.
FACT 03JAN20 19:47 ORF
R+R #2 ENGINSDR HNAA2020010600004Unknown · smokeCHO RAMP CONTROL WAS ADVISED BY THE CREW THAT THEY HAD SMOKE IN THE FLIGHT DECK DURING TAXI AND THEY CALLED CFR. ADVISED MOCC OF THE POTENTIAL SITUATION, AND THEY ADVISED THAT THEY WERE O THE PHONE WITH THE CA AND IT WAS MERELY A BAGGAGE COMPARTMENT FIRE TEST SDR HNAA2020010600003Uplock · crackedNDIS 640 33-20 0030560 03JAN20 MDT CLOSE
FRONT BEAM OF NLG UPLOCK BOX CRACKED
FACT 03JAN20 08:50 MDT
REMOVED FRONT BEAM OF NLG UPLOCK BOX. FABRICATED HOLES IN NEW BEAM AND INSTALLED HI-LOKS AND TOP ROW OF
RIVETS IRT STANDARD PRACTICES ANDSDR HNAA2020010600002Warning Message · false activationPDIS 659 32-41 2242582 02JAN20 CLT CLOSE
MULTIPLE BRAKE DEGRADED MSG DURING TAXI
DFRL 04JAN20 00:13 MDT
TRANSCRIBED TO HA300 SEQ 5 ON WORK PACKAGE DATED
01/03/2020.///CHECKED WIRES @ P3718 CANNON PLUG PIN 23 TO 24,78 TO SDR HNAA2020010300001Warning Message · false activationE1 REV DISAGREE MSG ON TAKE OFF....FIX: PERFORMED OPS CHECK OF T/R IN REF TO AMM 78-31-01-700-801A. CND FAILURE.OK FOR SERVICE, NO HISTORY 90 DAYSSDR SIMA2020021131010Light · damaged8EA FLOOR PROXIMITY LIGHT PANELS DAMAGED-C/A-COMPLETE:REMOVED AND REPLACED ALL FLOOR PROXIMITY LIGHT PANELS IAW EMB 145 AMM 33-50-12.SDR SIMA2020021131006Light · damaged#2, #4, #6, #7, AND #8 FLOOR PROXIMITY LIGHT STRIPS DAMAGED-C/A-COMPLETE:REMOVED AND REPLACED #2, #4 , #6, #7, AND #8 FLOOR PROX LIGHT STRIPS IAW EMB-145 AMM 33-50-12.SDR SIMA2020021123107Light · brokenRH CABIN FLOOR EMERGENCY LIGHT STRIPS BROKEN (5 EA)-C/A-COMPLETE:REMOVED AND REPLACED 5 RH FLOOR EMERGNCY LIGHT STRIPS AS REQUIRED.SDR SIMA2020021131008Light · inoperativeEMERGENCY LIGHT UNDER PANEL 233BLC AND COCKPIT STEP UP PANEL INOP-C/A-COMPLETE:REMOVED AND REPLACED WARDROBE EMERGENCY LIGHTS DC/AC INVERTER IAW EMB 145 AMM 33-50-11. OPC GOOD.SDR SIMA2020021123009Light · brokenLH ANGLE EMERGENCY LIGHT STRIP FOR PANEL 231FF IS BROKEN-C/A-COMPLETE:REMOVED AND REPLACED LH ANGLE EMERGECNY LIGHT STRIP FOR PANEL 231FF IAW EMB 145 AMM 33-50-12.SDR SIMA202001031005Door Sill · corrodedDURING HMBV INSPECTION, QC FOUND THE CARGO DOOR LOWER SILL CORRODED.-C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW EMB 145 SRM 51-40-02.SDR SIMA2020010231003Lamp · inoperativeLH AFT OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH AFT OVERWING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.SDR SIMA2020010231002Light · inoperative12B/C OVERHEAD EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED 12B/C OVERHEAD EMERGENCY LIGHT IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD.SDR SIMA2020010230003Skin · crackedDURING HMBV INSPECTION, QC FOUND RH AFT FUSELAGE SKIN CRACKED IN 2 AREAS ON FR 75 STGR 3R-C/A-REPAIRED CRACKS ON RH AFT FUSELAGE SKIN AT FR 75 AND STGR 3R IAW EMB 145 SRM 53-31-01-RE REPAIR #11. (REPAIR MATERIALS: DOUBLER 2024-T3, 0.080?, FILLER: 2024-T3, 0.0SDR SIMA2020010230001Skin · crackedDURING HMBV INSPECTION, QC FOUND AFT AVIONICS DOOR 272DR CRACKED UNDER EYELET.-C/A-REPAIRED AFT AVIONICS DOOR 272DR IAW EMB 145 SRM 52-44-02-RE ITEM 2 AND ERS-EM-5200-1043. (REPAIR MATERIALS: DOUBLER, 2024T3 0.050, FILLER, 2024T3 05050)SDR SIMA2020010230002Shear Tie · corrodedDURING HMBV INSPECTION, QC FOUND THE CARGO DOOR CUTOUT LOWER SHEAR CLIP AT FR 65 CORRODED-C/A-PERFORMED PERMANENT REPAIR ON CARGO DOOR CUTOUT LOWER SHEAR CLIP IAW EMB 145 SRM 53-31-04-RE ITEM 4. (REPAIR MATERIAL: SHEAR CLIP P/N 145-25175-001)SDR SIMA2020010230004Lamp · inoperative12C OVERHEAD EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED 12C OVERHEAD EMERGENCY LIGHT LAMP IAW EMB AM AND 33-50-08-400-801-A. OPC GOOD.SDR SIMA2020010229007Warning Message · false activationICE CONDITION-A/I INOP WG A/ICE FAIL.DECLARED EMERGENCY.-C/A-PERFORMED OPERATIONAL TEST OF THE ANTI-ICEING SYSTEM IAW EMB 145 AMM 30-00-00-700-802-A. SYSTEM OPERERATES NORMALLY. AIRCRAFT OKAY FOR SERVICE.SDR SIMA2020010229001Light · inoperativeRH EXT UPPER (OVER WING) EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED EXT UPPER (OVER WING) EMERGENCY LIGHT ASSY IAW AMM 33-50-07. OPC GOOD.SDR SIMA2020010229004Lamp · inoperativeAFT EMERG. CEILING LIGHT IS INOP-C/A-REMOVED AND REPLACED AFT EMERG. CEILING LIGHT LAMP, OPC GOOD, IAW AMM 33-50-08SDR HNAA2019123000399Engine · smokeAFTER TAKEOFF ATTEMPT, WHEN THRUST LEVERS WERE SET TO TAKEOFF THRUST, HEAVY SMOKE APPEARED IN THE COCKPIT. ONCE THRUST LEVERS WERE MOVED BACK TO IDLE, SMOKE CLEARED. MX TROUBLESHOT ISSUES AND DETERMINED TO BE THE NR 1 ENGINE BLEED SYSTEM, WHEN THRUST LEVERSDR SIMA2020010227005Skin · crackedDURING HMBV INSPECTION, QC FOUND LH AFT FUSELAGE SKIN CRACKED AT FR 75 ABOVE STGR 2L.-C/A-PERFORMED PERMANENT REPAIR TO CRACK ON LH REAR FUSELAGE I SKIN AT FR 75 ABOVE STGR 2L IAW EMB 145 SRM 53-31-01-RE REPAIR #11. (REPAIR MATERIALS: DOUBLER 2024-T3, 0.080?, SDR SIMA2020010227006Drag Angle · crackedDURING HMBV INSPECTION, QC FOUND THE LH VERTICAL STABILIZER TO FUSELAGE DRAG ANGLE CRACKED.-C/A-REMOVED AND REPLACED LH VERTICAL STABILIZER TO FUSELAGE DRAG ANGLE IAW EMB 145 SRM 51-40-02SDR SIMA2020010227007Web · crackedDURING HMBV INSPECTION, QA FOUND THE LH WING RIB 21 CRACKED INSIDE 551CB-C/A-PERFORMED PERMANENT REPAIR ON LH WING RIB 21 IAW EMB 145 SRM 57-20-07-RE ITEM 4.(REPAIR MATERIALS: FILLER-2024T3, 0.040, DOUBLER; 7475 T761, 0.050, SHIM; 2024T3, 0.032)SDR SIMA2019010227003Wire · brokenEMERGENCY LIGHTING SYSTEM (FLOOR PROXIMITY STRIP) AT SEAT 3A WIRE BROKEN INOP-C/A-EMER FLOOR STRIP LIGHTING AT SEAT 3A DEFERRED. REPAIRED BROKEN WIRE AT FLOOR STRIP 3A IAW SWPM 20-21-00. OPS CHECK GOOD. MEL RESTORED.SDR HNAA2019123000398Valve · failedNR 2 ENGINE BLLED OVERTEMP EICAS MSG WITH MASTER WARNING AND FULL RED INDICATION ON THE EICASW BLEED 2 TEMP INDICATOR . REMOVED AND REPLACED FAN AIR VALVE IAW AMM 36-11-03-000-801-A, AND 36-11-03-400-801-A. LEAK AND OPS CHECKED GOOD. OK FOR SERVICE.SDR SIMA20191227002Controller · malfunctionedCLIMBING THROUGH FL280 CABIN PRESSURE JUMPED RAPIDLY INTO THE AMBER ON THE EICAS BY THE TIME WE ESTABLISHED A DESCENT IT WAS IN THE RED AND RISING. FOUND KNOB ON MANUAL CONTROLLER STICKING. REMOVED AND REPLACED MANUAL CONTROLLER IAW AMM 21-31-02. OPS CHECKEDSDR SIMA20191227001Light · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. ADJUSTED THE LEFT OVERWING EMERGENCY LIGHT IAW AMM 33-50-10.SDR SIMA201912276002Web · crackedDURING HMBV INSPECTION, FOUND THE RT WING RIB 21 CRACKED INSIDE 551CB. PERFORMED A PERMANENT REPAIR ON THE RT WING RIB IAW SRM 57-20-07-RE ITEM 4.SDR SIMA201912276001Stringer · crackedDURING HMBV INSPECTION, QC FOUND STR 6R CRACKED BETWEEN FR 12-13.-C/A-REMOVED AND REPLACED STR 6R BETWEEN FR 12-13 IAW EMB 145 SRM 51-40-02.SDR RAIA2019122760001Bulb · inoperativeSERVICE DOOR FLOOD LIGHT WAS INOPERATIVE. R&R LIGHT BULB. OPS CHECKED GOOD.SDR SIMA201912275001Inverter · inoperativeDURING PS-1 CHECK, FOUND RH OVERWING EXTERNAL EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED #6 EMERGENCY LIGHT DC/AC INVERTER IAW AMM 33-50-11. OPC GOODSDR SIMA201912275002Battery Pack · inoperativeDURING PS-1 CHECK, FOUND EMERGENCY LIGHT INOPERATIVE BETWEEN 12A AND 9A. REMOVED AND REPLACED THE NR 3 BATTERY POWER SUPPLY AND BATTERY IAW AMM 33-50-04, OPS-CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR ASOA2020010224467Charger · no testIAH - FLIGHT 4309 MX REPORTED THAT THE EMERGENCY LIGHT CEILING PANEL AISLE LIGHT #2 ND R/H FWD EXTERIOR LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO BATTERY CHARGER, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE AIRCSDR ASOA2019123045119Unknown · odorPILOT REPORTED SMOKE ODOR IN FLIGHT DECK AFTER STARTING APU. MX PERFORMED A FEW APU STARTS NO SMOKE OR ODOR DETECTED IN FLIGHT DECK. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201912274004Profile · corrodedDURING HMBV INSPECTION, FOUND THE CARGO LOWER FRAME PROFILE CORRODED. REMOVED AND REPLACED CARGO DOOR LOWER FRAME PROFILE IAW SRM 51-40-02.SDR SIMA201912274006Channel · corrodedDURING HMBV INSPECTION, QC FOUND SERVICE DOOR CENTER SILL CORRODED.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA201912274005Web · corrodedDURING HMBV INSPECTION, FOUND CARGO DOOR INNER WEB CORRODED AROUND 1 SCREW HOLE. REPAIRED THE CARGO DOOR INNER WEB IAW SRM 52-30-01-RE ITEM 12 AND ETN-EM-52-043.SDR SIMA201912274007Shear Tie · corrodedDURING HMBV INSPECTION, FOUND FRAME 68 SHEAR TIE CORRODED AT CARGO DOOR LOWER SILL. REPAIRED THE SHEAR TIE IAW SRM 53-21-04-RE ITEM 4.
Back to Embraer EMB-145LR