Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201912087137Skin · dentedTYS A/C WAS FOUND WITH GROUND DAMAGE TO THE FUSELAGE AT FRAME 68 THRU 70 AND STRINGER 16L AND 17L.MAINTENANCE CUT OUT THE DAMAGE AREA AND SPLICED A INTERNAL DOUBLER AND REPLACED THE NEW SKIN IAW ETD 2019-145-159935.ALL WORK ACCOMPLISHED AND WILL BE RELEASED WHSDR SIMA201912096004Fire Detector · failedNR 1 ENGINE FIRE LOOP FAILED MESSAGE DURING CLIMB. PERFORMED OP CHECK OF E1 FIRELOOP DETECTOR IAW EMB 145 AMM 26-10-00. FOUND WOP E1 FIRE DETECTOR-REMOVED AND REPLACED E1 ENGINE FIRE DETECTOR IAW AMM 26-11-01, OPS CHECKED GOODSDR HNAA2019120900378Handle · out of adjustMAIN CABIN DOOR WOULD NOT OPEN FROM INSIDE THE CABIN. FIX ADJUSTED PAX DOOR INNER HANDLE IAW EMB 145 AMM 52-18-00 OPTS CHECK GOOD AT THIS TIME OK FOR SERVICE.SDR HNAA2019120900377Uplock Switch · failedAFRER TAKEOFF AFTER SELECTING GEAR UP. OBSERVED LOUD BANGING NOISE. RIGHT M.L.G. SHOWED GEAR UP AND IN TRANSIT INTERMITENTLY. AFTER 4200 FEET INDICATIONS AND OPERATIONS WERE NORMAL. MX PERFORMED EXTENSION AND RETACTION SYSTEM OPS CHECK IAW AMM 32-30-00 NO FAULSDR SIMA20191206001Skin · chafedDURING HMBV INSPECTION, QC FOUND THE FUSELAGE SKIN UNDER PYLON PANEL 424DB CHAFED.-C/A-PERFORMED PERMANENT REPAIR ON FUSELAGE SKIN UNDER PYLON PANEL 424DB IAW EMB 145 SRM 53-31-01 ITEM 12 FIGURE 220 SHEET 3.SDR SIMA20191206002Shear Tie · corrodedDURING HMBV INSPECTION, QC FOUND FR 65 SHEAR CLIP AT CARGO DOOR LOWER CUTOUT CORRODED-C/A-PERFORMED PERMANENT REPAIR ON FR 65 SHEAR CLIP AT CARGO DOOR LOWER CUTOUT IAW EMB 145 SRM 53-31-04 FIGURE 212 AND ETN-EM-53-272. REPAIR MATERIALS: P/N 145-25175-001SDR SIMA20191206003Floor Support · corrodedDURING HMBV INSPECTION, QC FOUND THE CARGO DOOR CUTOUT LOWER FLOOR SILL BETWEEN FR 65 AND FR 68 CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL BETWEEN FR 65 AND FR 68 IAW EMB 145 SRM 51-40-02. REPAIR P/N 145-25480-603SDR HNAA2019120900376Landing Gear · malfunctionedAFTER TAKEOFF, AFTER SELECTING GEAR UP, OBSERVED LOUD BANGING NOISE, RH MLG SHOWED GEAR UP AND IN TRANSIT INTERMITENTLY. AFTER 3500 FT, INDICATIONS AND OPERATIONS NORMAL. MX PERFORMED EXENSION AND RETRACTION SYSTEM OPS CHECK IAW AMM 32-30-00-700-801-A. NO FASDR HNAA2019120600375Knob · detachedSTAND-BY ALTIMETER KNOB FELL OFF....FIX: RESECURED KNOB.OK FOR SERVICE.OPS CHECK GOODSDR SIMA201912065001Charger · inoperativeLH FWD EXTERIOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY AND CHARGER, OPC GOOD, IAW EMB AMM 33-50-04. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 77460SDR HNAA2019120900380Engine · shutdown#1 ENG SHUT DOWN ON ITS OWN PASSING THRU FLT LEVEL 330. FOLLOWED QRH ATTEMPTED RESTART FAILED. ENG OUT EICAS MSG DISPLAYED. FIX ENGINE IS REMOVED AND REPLACED.SDR HNAA2019120900379Filter · dirtyREJECTED TAKEOFF DUE TO BLD 2 OVTEMP WARNING. FOLLOWED BY PACK 2 OVERHEAT. MX PERFORMED C/W VISUAL INSPECTION OF PRE COOLER LINE REGION. NO DISCONNECTED OR DAMAGED COMPONENTS. CLEANED FAN VALVE FILTER AND C/W OPS CHECK I/A/W M/M 36-11-03 AND TASK 36-00-00-700-SDR SIMA201912054002Bulb · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT BULB, OPC BAD, IAW EMB AMM 33-50-07SDR SIMA201912054003Charger · inoperativeBOTH EXTERNAL OVERWING AFT EMERGENCY LIGHTS INOP-C/A-T/S IAW EMB WIREING MANUAL 33-50-50, REMOVED AND REPLACED NUMBER 4 BATTERY AND CHARGER IAW W/C 33-700-19. OPC GOOD, NO FUTHER DEFECTS FOUND. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 103797SDR SIMA201912043002Battery Pack · inoperativeLH FWD EXTERNAL EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH EXTERNAL EMERGENCY LIGHT IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A NO FIX T/S WITH WM 33-50-50 FOUND BATTERY #1 AND CHARGER INOPERATIVE REMOVED AND REPLACED BATTERY #1 AND CHARGSDR ASOA201912037136Rib · crackedL/H WING RIB 21 CRACKED. REPAIRED RIB 21 BU CUTTING OUT THE CRACKED FLANGE, FABRICATING, INSTALLING DOUBLER AND SHIM. AIRCRAFT STILL IN C CHECKSDR SIMA201912032003Battery Pack · inoperativeDURING PS-1 CHECK FOUND MULTIPLE EMERGENCY LIGHTS OUT NEAR CENTER FUSELAGE.-C/A-REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY AND CHARGER ASSEMBLY IAW EMB 145 W/C 33-700-19. OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12788SDR SIMA201912021003Unknown · odorAIR CONDITIONING PACK NR 1 PRODUCING AN OILY SMELL & NOT COOLING VERY WELL. PERFORMED A NR 1 PACK OPS CHECK IAW AMM 21-51-00. PERFORMED ETN -EM -72-034-ENG ODOR EVENT TROUBLESHOOTING. NO ODOR WAS DETECTED AND SYS WAS COOLING PROPERLY. OPS CHECKED GOOD. NSDR HNAA2019122700393Nut Plate · corrodedCORRODED NUTPLATE HOLES ON CARGO CUTOUT STRUCTURE LOWER CENTER SILL. R & R THE CARGO DOOR SILL IAW SRM 51-40-02.SDR HNAA20191227001Yoke · crackedLEFT ENGINE FWD LOWER YOKE HAS CRACK ON FWD LOWER CORNER. R & R LH FWD YOKE FITTING AND GUSSET PLATE IAW EO1-71-19-0565.SDR ASOA2019120495116Acm · odorPILOT REPORTED STRONG ELECTRICAL ODOR IN COCKPIT LASTED SEVERAL MINUTES AND CLEARED. FA REPORTED "HAZE" IN CABIN ALSO LASTING SERVERAL MINUTES. ITEM MOVED TO MEL#21-51-00-3. 12/4/19 MX REPLACED #1 PACK ACM WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETSDR SIMA201912029003Lamp · inoperativeDURING PS-1 CHECK, FOUND LH OVERWING EXTERNAL EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED OVERWING EXTERNAL EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPERATIONAL CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.SDR SIMA201912028001Power Supply · inoperativeFOUND OVERWING EMERGENCY LIGHTS INOP.-C/A-REMOVED AND REPLACED #4 EMERGENCY LIGHTING POWER SUPPLY AND BATTERY IAW WORKCARD 33-700-19, OPS CHK GOOD. WORKCARD 33-700-17. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 82530SDR HNAA2019122700395Profile · corrodedCARGO DOOR LOWER I/B PROFILE CORRODED AROUND NUTPLATES....FIX:R&RD CARGO DOOR LWR INBD PROFILE IAW EMB145 SRM 51-40-02SDR HNAA2019122700392Nut Plate · corrodedCARGO DOOR WEB HAS 2 AREAS AROUND NUTPLATES CORRODED. REPAIRED IAW EMB SRM 52-30-01RE AND EO1-52-19-0557SDR HNAA2019120200374Connector · unsecurePDIS 690 21-31 2248721 27NOV19 PHL CLOSE
PACK 2 VALVE CLOSED MSG ON CLIMBOUT WITH PACK 1 VALV
E CLOSED MSG AFTER APPOX 2 MINS. BOTH UNABLE TO CLEA
R WITH QRH. PACK 1 CLEARED BELOW 100K
FACT 27NOV19 10:06 PHL
WHEN SDR HNAA2019120200373Wire · brokenMDIS 608 33-50 2106261 27NOV19 LEX CLOSE
OVERHEAD EMERGENCY EXIT LIGHT AT ROW 12 INOP DUE TO
BROKEN WIRE AND DAMAGED FIXTURE AT CONNECTOR.
42300 00 DEW
OVERHEAD EMERGENCY EXIT LIGHT ATSDR HNAA2019122700397Skin · crackedCARGO DOOR SKIN WAS CRACKED AT THE AFT END OF THE HANDLE. INSTALLED A REPAIR DOUBLER AND FILLER IAW EO1-52-19-0555.SDR ASOA2019120265115Sign · inoperativeDURING MX INSPECTION THE EMERGENCY EXIT SIGN AT ROW 3CD WAS INOP. MX REMOVED AND REPLACED THE EXIT SIGN WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201911276002Apu · malfunctionedAPU FAIL & SHUTDOWN DURING STEADY STATE OPERATION AT FL360.-C/A-CHECKED OK FOR DEFERRAL PER MEL 49-1. M PROCEDURES C/W. AUTH # 110898DM-C. EXPIRES 12-6-19. PLACARD INSTALLED. PERF OPERATIONL TEST OF APU WITH BOTH ELECTRICAL AND PNEUMATIC LOADS IAW EMB 145 SDR HNAA2019122700396Skin · gougedLH WING LEADING EDGE NR 1 EXTERIOR HAD ONE GOUGE. FABRICATED AND INSTALLED A REPAIR IAW SRM 51-20-01, AND EO1-57-19-0566.SDR SIMA201911254002Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10. OPC GOODSDR SIMA201911253002Cradle · damagedAFT CABIN FLASHLIGHT CRADEL DAMAGED-C/A-PEFORMED VISUAL INSPECTION OF THE FLASHLIGHT ASSEMBLY IN AFT AND FOUND BRACKET TO BE DAMAGED. REMOVED AND REPLACED BRACKET REF CMM 25-60-14. OPS CHECK GOOD.SDR SIMA201911253001Sensor · out of adjustLG AIR/GND FAIL MSG ON EICAS SHORTLY AFTER TAKE OFF-C/A-FOUND CMC MSG FOR RH & LH MLG WOW SWITCH FAIL, FOUND FWD AND AFT WOW SWITCH GAP OUT OF MAXIMUM LIMIT AT THE LH LG AND ADJUSTED BOTH TO THE MINIMUM GAP IAW EMB145 AMM 32-63-05. PERFORMED OHM AND INSULASDR HNAA2019112700371Spoiler Sys · malfunctionedSPOILER FAIL MESSAGE ON DESCENT WITH STRONG LEFT ROLLING TENDENCY....FIX: INSPECTED AND CLEANED PROX SWITCH FOR SPOILER SYSTEM, NO DEFECTS NOTED.PERFORMED SPOILER OPS CK IAW AMM 27-63-01.TRANSITORY CONDITION OF SCU. T/S IAW FIM 27-63-00-810-802-ASDR SIMA201911252004Battery Pack · inoperativeDURING PS-1 CHECK, FOUND BOTH LH AND RH EXTERIOR OVERWING EMERGENCY LIGHTS INOP-C/A-REMOVED AND REPLACED BATTERY ASSEMBLY AND BATTERY CHARGER ASSEMBLY IAW AMM 33-50-04. OPERATIONAL CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. CHARGEDR ASSY BATTERY P/N BA5-0933-9SDR SIMA20191121001Controller · failedDURING INITIAL CLIMB AIRCRAFT DID NOT PRESSURIZED CABIN ALTITUD EQUALIZED AT 8000 FEET COMPLIED WITH PROCEDURES AND LANDED IN MIA.-C/A-REMOVED AND REPLACED PRESSURIZATION DIGITAL CONTROLLER IAW AMM 21-31-01. PERFORMED OPS CHK IAW AMM 21-23-00. OPS CHK GOOD.SDR HNAA2019112700370Warning Message · false activationSTAB ANTI-ICE FAIL MESSAGE DISPLAYED....FIX:FOLLOWED FIM TASK 30-12-00-810-805-A.CHECKED CMC MESSAGE, HAD A/ICE LOW PRESSURE DISPLAYED.PER FIM OPS CHECKED A/ICE SYS IAW AMM 30-00-00/500 WITH OPS CHECK GOOD. DETERMINED TO BE TRANSITORY.SDR ASOA201911205114Sign · inoperativeDURING MX INSPECTION THE EMERGENCY LIGHTS ON THE FWD AND AFT SECTION OF THE AIRCRAFT WERE FOUND INOP. MX REMOVED AND REPLACED FWD EMERGENCY EXIT MARKING LIGHT AT MAIN DOOR AND RESECURED #2 BATTERY POWER SUPPLY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR SDR ASOA2019112205113Display · odorPILOT REPORTED ELECTRICAL SHORT FUMES IN COCKPIT. MX REMOVED AND REPLACED THE EICAS DISPLAY UNIT WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2019112204064Acm · frozenIAH - FLIGHT 4418 THE CREW REPORTED A STRONG SMELL IN THE COCKPIT. THE AIRCRAFT LANDED AT IOAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE LEFT HAND ACM. OPERATIONALLY TESTED WITH NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERSDR SIMA2019121819006Floor Support · corrodedLH OMEGA BEAM CORRODED FWD OF CROSSBEAM AT FR 29-C/A-REPAIRED LH OMEGA BEAM FWD OF CROSSBEAM AT FR 29 IAW ENVOY ERS-EM-53MR-3977.SDR HNAA2019112700368Window Frame · crackedCAPTS WINDOW PILLAR CRACKED, BTWEEN W/S AND DV WINDOWS....FIX: PERFORMED EDDY CURRENT INSPECION AT CAPT,S PILLAR INNER AND OUTER SURFACE SKIN. NO CRACKS FOUND AT HIS TIME. PILLAR FOUND TO BE SEPARATING AT SEAM. NOTE: A/C FERRIED TO SBY WHERE 7 RIVETS REPLACED SDR SIMA2019112219005Carbon Seal · failedSTRONG BURNING SMELL EACH TIME ANTI-ICEING CAME ON-C/A-REMOVED AND REPLACED RH ENGINE #0 CARBON SEAL IAW RRMM TASK 72-25-25-000-801 & 72-25-25-400-801 AND OPC IAW ETN-EM-72-034 OPC GOOD AT THIS TIME PIREP RESTORED.SDR SIMA2019112019003Light · inoperativeAFT AILE EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED AFT AILE EMERGENCY LIGHT IAW EMB AMM 33-50-08-000-801 AND 33-50-08-400-801 OPS CHECK GOODSDR HNAA2019112700372Trim System · lack of lubeFO YOKE PITCH TRIM INOP IN FLIGHT. ON GROUND PITCH TRIM UP OK, PITCH RIM DOWN INOP.....FIX:LUBED FOS PITCH TRIM ON YOKE IAW AMM 27-40-03-640-801A.OPS CHECK GOOD.GOOD FOR SERVICE.CLEARED MEL.SDR HNAA2019112700369Warning Message · false activationPACK 1 OVRHEAT MESSAGE URING T/O ROLL.#2 PACK ON MEL....FIX: GROUND RAN A/C WITH BOTH ENGINES,OPS CK #1 PACK IAW EMB 145 21-51-00 OPS CK GOOD NO OBVIOUS DEFECTS NOTED,OK FOR SERVICESDR SIMA201911198002Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT ASSEMBLY IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR ASOA2019111984064Light · inoperativeIAH - FLIGHT 4090, DURING MAINTENANCE INSPECTION THE EMERGENCY LIGHT ABOVE THE FWD HANDSET WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED OF RETURN TO SERVICESDR SIMA20191118001Skin · dentedDENT AND SCRATCH LH REAR FUSELAGE II BETWEEN FR 78 AND FR 79 AND STR 5L AND 7L-C/A-PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-3952
Back to Embraer EMB-145LR