Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20190516005Attach Angle · crackedLEFT UPPER WING TO FUSELAGE FAIRING, LOWER ATTACH ANGLE ON WING JUST FWD OF SPAR 3 HAS A 3/4' CRACK. C/A-REMOVED AND FABRICATED NEW SECTION OF DAMAGED LT UPPER WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE ON WING JUST FWD OF SPAR III IAW ETN-EM-53-142. 53-142.May 16, 2019 · N670AE · Emb EMB145LR · Wing, Attach FittingsSDR SIMA20190516004Attach Angle · crackedRIGHT UPPER WING TO FUSELAGE FAIRING, LOWER ATTACH ANGLE ON WING JUST FWD OF SPAR 3 HAS 2 CRACKS. (APPROX. 1" AND 2" IN LENGTH). C/A-RAR DAMAGED SECTION RT UPPER WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE ON WING JUST FWD OF SPAR III IAW ETN-EM-53-142.May 16, 2019 · N670AE · Emb EMB145LR · Wing, Attach FittingsSDR SIMA20190516003Spring · defectiveSUPPLEMENTAL GROUND SERVICE PANEL OPENED INFLIGHT. SPRING ON PANEL INOP AND DENT IN FUSELAGE. C/A-DEFFERED EXT POWER CONNECTION ACCESS DOOR AUTH# 050533CDL-D. INSTALLED NEW GROUND SERVICE PANEL IAW SRM 51-40-02. CDL ITEM RESTORED. REPAIRED SKIN GOUGE WITH SMALMay 16, 2019 · N932AE · Emb EMB145LR · Air Conditioning DoorsSDR SIMA20190516002Holder · brokenFA'S FLASHLIGHT HOLDER BROKEN. C/A-REMOVED AND REPLACED FLIGHT ATTENDANTS FLASHLIGHT HOLDER IAW AMM 33-50-16-000-801-A AND 33-50-16-400-801-A NO OTHER DEFECTS NOTED OPC GOOD.May 16, 2019 · N678AE · Emb EMB145LR · Emergency EquipmentSDR HNAA2019051600143Light · inoperative641 33-51 0022950 15MAY19 RIC CLOSE CEILING EMERGENCY LIGHT ABOVE MAIN DOOR DOES NOT ILLUMINATE. 28916 00 NGR FACT 15MAY19 11:29 RIC R/R MAIN DOOR EMERGENCY LIGHT IN REF TO AMM 33-50-06-000/400-801-A. P/N ON LIGHT 1317 P/N OFF LIGHT 1317.May 15, 2019 · N641AE · Emb EMB145LR · Emergency LightingSDR SIMA201906124003Light · cracked#1 AND #4 RH ISLE FLOOR EXTRUSION CRACKED-C/A-COMPLETE:REMOVED AND REPLACED #1 AND #4 RH ISLE FLOOR EXTRUSION IAW EMB 145 AMM 33-50-12May 14, 2019 · N653AE · Emb EMB145LR · Emergency LightingSDR SIMA2019061214002Light · cracked#1 EMERGENCY FLOOR LIGHT EXTRUSION CRACKED-C/A-COMPLETE:REMOVED AND REPLACED #1 EMERGENCY FLOOR LIGHT EXTRUSION IAW EMB 145 AMM 33-50-12May 14, 2019 · N653AE · Emb EMB145LR · Emergency LightingSDR SIMA2019061214004Light · brokenFLIGHT DECK EMERGENCY LIGHT ASSEMBLY BROKEN REQUIRES REPLACEMENT. OLD PART TEMP INSTALLED UNTIL PROCUREMENT OF NEW ASSEMBLY.-C/A-COMPLETE:REMOVED AND REPLACED EMERGENCY LIGHT IN FLIGHT DECK IAW EMB 145 AMM 33-30-01.May 14, 2019 · N653AE · Emb EMB145LR · Emergency LightingSDR HNAA2019051600142Light · inoperative656 33-51 0003170 14MAY19 SBY CLOSE RT LATERAL PANEL EMERGENCY LIGHT INOP. 30100 00 CRH FACT 14MAY19 09:32 SBY R&RED RT LATERAL PANEL EMERGENCY LIGHT LIGHT BULB IAW AMM 33-50-10-000-801-A AND 33-50-01-700-801-A. P/N ON BULB 1317 P/N OFF BULB 1317.May 14, 2019 · N656AE · Emb EMB145LR · Emergency LightingSDR ASOA201905147046Rib · crackedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND RIB 21 INSIDE ACCESS PANEL 551CB CRACKED. MAINTENANCE REMOVED THE DAMAGED AREA AND FAB. A FILLER AND DOUBLER FOR RIB 21 IAW SRM 57-20-07. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.May 14, 2019 · N16987 · Emb EMB145LR · Wing, Rib/BulkheadSDR ASOA201905147045Rib · crackedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND A CRACK AT RIB 21 INSIDE ACCESS PANEL 651CB. MAINTENANCE REMOVED THE DAMAGED AREA OF RIB 21 AND REPLACED WITH FILLER AND DOUBLER IAW SRM 57-20-07. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.May 14, 2019 · N16987 · Emb EMB145LR · Wing, Rib/BulkheadSDR SIMA20190513002Sign · inoperativeDURING PS-1 CHECK, FOUND EXIT SIGN NEAR THE MAIN DOOR TO BE INOP. C/A-REMOVED AND REPLACED EXIT SIGN IAW AMM 33-50-14. OPS CHECK GOOD.May 13, 2019 · N680AE · Emb EMB145LR · Emergency LightingSDR SIMA20190513001Fcu · failedFUEL IMBALANCE CAUTION MESSAGE ON EICAS APPROXIMATELY 300 FEET AGL. TANK 1 TOTAL QTY INDICATING 0 LBS. DID NOT SUSPECT FUEL LEAK. C/A-FUEL PANEL SHOWS FCU 1 FAIL REMOVED AND REPLACED FCU IAW AMM 28-41-01 CHECK GOOD AT THIS TIME.May 13, 2019 · N653AE · Emb EMB145LR · Fuel Quantity IndicatorSDR SIMA20190512003Wire · brokenSERVICE DOOR EXTERNAL EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED SERVICE DOOR EXTERNAL EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. FOUND BROKEN WIRE AND SPLICED WIRE IAW SWPM 20-21-00. OPS CHECK GOOD. NO FURTHER DEFECTS May 12, 2019 · N902BC · Emb EMB145LR · Light System WiringSDR SIMA20190512001Sign · unsecureILLUMINATED EMERGENCY EXIT SIGN FELL ( OVER ROW 12 ). C/A-REMOVED AND REPLACED EXIT LOCATING SIGN IAW AMM 33-50-15. OPS CHECK GOOD.May 12, 2019 · N685AE · Emb EMB145LR · Emergency LightingSDR SIMA20190512002Light · inoperativeFLOOR EMERGENCY LIGHT STRIP AT ROWS 6A/7A INOP. C/A-REMOVED AND REPLACED EMERGENCY LIGHT STRIP IAW AMM 33-50-12 OPS TEST GOOD.May 12, 2019 · N616AE · Emb EMB145LR · Emergency LightingSDR SIMA2019061251006Light · damagedAFT LH AND RH EMERGENCY FLOOR LIGHTING EXTRUSIONS IN LAV AREA DAMAGED-C/A-COMPLETE:AFT LH AND RH EMERGENCY FLOOR LIGHTING EXTRUSIONS ARE INSTALLED IN LAV AREA IAW AMM 33-50-12May 11, 2019 · N670AE · Emb EMB145LR · Emergency LightingSDR SIMA20190511005Brake · failedNR 4 BRAKE FAILS CARBON INSPECTION. C/A-REMOVED AND REPLACED NR 4 MLG BRAKE IAW W/C 32-600-14 OPS CHECK GOOD.May 11, 2019 · N928AE · Emb EMB145LR · BrakeSDR SIMA20190511003Light · inoperativeDURING PS-1 CHECK FOUND EXTERNAL OVERWING EMERGENCY LIGHT NOT WORKING ON LEFT HAND SIDE. C/A-REMOVED AND REPLACED EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECK GOOD.May 11, 2019 · N935AE · Emb EMB145LR · Emergency LightingSDR SIMA20190510002Crease Beam · corrodedCORROSION ON RIGHT HAND CREASE BEAM BETWEEN FRAMES 19-20. C/A-REMOVED AND REPLACED RT CREASE BEAM BETWEEN FRAMES 19-20 IAW SRM 51-40-02.May 10, 2019 · N925AE · Emb EMB145LR · Fuselage Main, StructureSDR RAIA201905090001Door Sill · crackedLT FLOOR SILL AT FR 23 SPLICE IS CRACKED. R&R LT FLOOR SILL AT FR 23 SPLICE.May 9, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2019051300141Shutoff Valve · malfunctioned628 30-10 1853811 09MAY19 PHL CLOSE DURING CLIMB CHECKLIST, ANTI ICE TEST FAILED WING ANTI ICE CAUTION PRESENT. 28568 00 CVS HISTORY: FACT 09MAY19 12:07 PHL R&R'D NR 2 PRSOV IAW IAW AMM 36-11-05. OPS CHECK GOOD. NO EICAS MESSAGES OK FOR SERVIMay 9, 2019 · N628AE · Emb EMB145LR · Pneumatic Distribution SystemSDR HNAA2019051300140Connector · not seatedNDIS 692 33-51 0010370 09MAY19 SBY CLOSE EMERGENCY LIGHT ON BULKHEAD AT ROW 2 INOP 30155 00 SJU FACT 09MAY19 10:29 SBY REMOVED TRIM PANEL OF SAID EMERGENCY LIGHT RESEATED ELECTRICAL CONNECTOR OF SAID EMERGENCY LIGHT AND REINSTALLED TRIM PANEL USMay 9, 2019 · N692AE · Emb EMB145LR · Light System WiringSDR SIMA20190509001Roller · lack of lubeFA REPORTED THAT THE MAIN CABIN DOOR WAS DIFFICULT TO OPEN- LATCHES WERE STICKING. C/A-C/W MAIN CABIN DOOR FRAME ROLLERS LUBE IAW AMM 53-21-02. FOUND SATISFACTORY AT THIS TIME.May 9, 2019 · N693AE · Emb EMB145LR · Passenger/Crew DoorsSDR RAIA201905080020Angle · crackedLT OVER WING ANGLE CRACKED AT FR 46. REMOVED DAMAGED SECTION OF LT OVERWING ANGLE AT FR 46 & REPAIRED. ANGLE NEEDS NUTPLATES. INSTALLED NUTPLATES ON LT OVERWING ANGLE AT FR 46.May 8, 2019 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905090002Angle · crackedRT OVER WING ANGLE CRACKED BETWEEN FR 48 & 49 (48.5). R & R RT OVER WING ANGLE BETWEEN FR 48 & 49.May 8, 2019 · N842HK · Emb EMB145LR · Wing Miscellaneous StructureSDR RAIA201905080019Angle · crackedRT OVER WING ANGLE CRACKED AT FR 49. R & R LT OVER WING ANGLE AT FR 49.May 8, 2019 · N842HK · Emb EMB145LR · Wing Miscellaneous StructureSDR RAIA201905080018Angle · crackedRT OVER WING ANGLE CRACKED AT FR 48. R & R LT OVER WING ANGLE AT FR 48.May 8, 2019 · N842HK · Emb EMB145LR · Wing Miscellaneous StructureSDR RAIA201905080017Angle · crackedLT OVER WING ANGLE CRACKED AT FR 49. R & R LT OVER WING ANGLE AT FR 49.May 8, 2019 · N842HK · Emb EMB145LR · Wing Miscellaneous StructureSDR RAIA201905080016Angle · crackedLT OVER WING ANGLE CRACKED AT FR 48. R&R LT OVER WING ANGLE AT FR 48.May 8, 2019 · N842HK · Emb EMB145LR · Wing Miscellaneous StructureSDR RAIA201905080015Floor Support · corrodedGUSSET AT FR 15 RT OMEGA BEAM CORRODED AT NUTPLATES. REMOVED HARDWARE AND FASTENERS AT FR STA 15 RT OMEGA BEAM. INSTALLED NEW OMEGA BEAM SPLICE ON RT SIDE AT FRAME 15.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080014Door Sill · gougedRT FLOOR SILL FR 66-68 IS GOUGED. REMOVED AND PICKED UP NEW HOLES. INSTALLED RT FLOOR SILL.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080013Shear Tie · crackedLT FR 66 STR 17 SHEAR CLIP IS CRACKED. REMOVED LT FR 66 STR 17 SHEAR CLIP. INSTALLED LT FR 66 STR 17 SHEAR CLIP.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Internal Mounting StructureSDR RAIA201905080012Shear Tie · crackedLT FR 72 STR 16 SHEAR CLIP IS CRACKED. REMOVED AND INSTALLED NEW SHEAR CLIP.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Internal Mounting StructureSDR RAIA201905080011Angle · crackedFR 17 CENTER OMEGA BEAM LT LOWER ANGLE CRACKED. REMOVED & REPLACED ANGLE.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080010Support · crackedFWD TORSION BAR SUPPORT IS CRACKED. R&R FWD TORSION BAR SUPPORT.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080009Support · crackedAFT UPPER AND LOWER TORSION BAR SUPPORT IS CRACKED. R&R AFT UPPER AND LOWER SUPPORT TORSION BAR SUPPORT.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080008Support · crackedLT LOWER OMEGA BEAM SUPPORT IS CRACKED AT FR 48. R&R LT OMEGA BEAM SUPPORT AT FR 48.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080007Door Sill · corrodedLT FLOOR SILL FROM FR 36-41 IS CORRODED. R&R LT FLOOR SILL FROM FR 36-41.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080006Door Sill · corrodedLT FLOOR SILL FROM FR 29-35 IS CORRODED. R&R LT FLOOR SILL FROM FR 29-35.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080005Gusset · corrodedCENTER LAV OMEGA BEAM GUSSET CORRODED. R&R CENTER LAV OMEGA BEAM GUSSET.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080004Gusset · corrodedRT LAV OMEGA BEAM GUSSET CORRODED. R&R RT LAV OMEGA BEAM GUSSET.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190508005Relay · failedDURING APU/BAGGAGE FIRE AND SMOKE TEST CARGO LIGHT FAILED TO ILLUMINATE. C/A-REFER WORK PERFORMED ON TURNOVER THIS NRWC. RAR RELAY K0438 IAW SWPM 20-13-03. DID NOT FIX. RAR RELAY K0625 IAW SWPM 20-13-03. DID NOT FIX. RAR RELAY K0630 IAW SWPM 20-13-03. OPS CHECMay 8, 2019 · N685AE · Emb EMB145LR · Smoke DetectionSDR RAIA201905080003Door Sill · corrodedRT FLOOR SILL FROM FR 24-29 IS CORRODED. R&R RT FLOOR SILL FROM FR 24-29.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080002Door Sill · corrodedRT FLOOR SILL FROM FR 24-29 IS CORRODED. R&R RT FLOOR SILL FROM FR 24-29.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201905080001Door Sill · corrodedLT FLOOR SILL FROM FR 23-29 IS CORRODED. REMOVE & REPLACED FL SILL.May 8, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190508004Not Reported · damagedRT SIDE RVSM CRITICAL AREA, 1" CREASE LEFT OF CENTER. "TRANSFERRED TO NRWC 615-ORD-02843". C/A- C/W ERS-EM-5300-3770. AC IS GOOD FOR RETURN TO SERVICE.May 8, 2019 · N615AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190508002Warning System · false activationBLEED 2 LEAK IN CLIMBOUT. C/A-PERFORMED LEAK CHECK OF NR 2 BLEED SYSTEM IAW MM 36-00-00 AND ETNEM-36-063. OPS CK AND LEAK CHECK GOOD,May 8, 2019 · N605KS · Emb EMB145LR · Pneumatic Indicating SystemSDR HNAA2019050900138Unknown · odorPDIS 658 21-01 1880552 08MAY19 PHL CLOSE BURNING SMELL IN GALLEY 28786 00 AR FACT 08MAY19 04:04 PHL REMOVED ACCESS PANELS 223ELW, 223UZ, 224MZ TO FOM. INSPECTED COMPARTMENTS NO FEFECTS NOTED AT THIS TIME AND REINSTALLED PANELS 223ELW, 223UZ 224MMay 8, 2019 · N658AE · Emb EMB145LR · Air Distribution SystemSDR ASOA201905073032Skin · crackedDURING C CHECK INSPECTION A CRACK WAS FOUND ON CARGO DOOR SKIN AT HANDLE HOUSING CUT-OUT. MAINTENANCE REPAIRED CRACK IAW 52-30-01.May 7, 2019 · N14562 · Emb EMB145LR · Cargo/Baggage Doors
Back to Embraer EMB-145LR