Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20190527002Acm · failedPACK 2 OVHTIN FLIGHT RESOLVED WITH QRH UPON LANDINGPACK 1&2TEMP CONTROL UNRESPNSIVE WITH EITHER BLEED CONFIG AND RUBBER SMELL. C/A-C/W EO EM-2100-048, REMOVED AND REPLACED #1 ACM AND CONDENSER/MIXER IAW AMM 21-51-03 AND 21-51-04, PERFORMED ODOR EVENT TROUBLESHMay 27, 2019 · N694AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2019052900153Fuse · blown649 30-41 1912642 27MAY19 RIC CLOSE REF LP 1912643 WS HT 2 PLACED ON MEL AS PRECAUTION.PULLED AND COLLARED CB J20 PER MEL MX PROCEDURE MEL 27MAY19 15:45 RIC C14722 30-15 WINDSHIELD HEATING SYSTEMS FACT 28MAY19 05:36 PHL R&R FUSE F0002 IAW May 27, 2019 · N649PP · Emb EMB145LR · Windshield/Door Rain/Ice RemovalSDR HNAA2019052900152Warning System · false activation649 30-41 1912633 27MAY19 RIC CLOSE W/S HT 2 EICAS ASSOCIATED W/ BURN SMELL, SELECTED W/S HT 2 OFF, WAITED, SELECTED ON AND ODOR INTENSIFIED FACT 27MAY19 18:32 RIC INSPECT FLT DECK FOR DEFECTS IAW FIM 21-20-00-810-801-A. NO DEFECTS NOTED. PERF W/SMay 27, 2019 · N649PP · Emb EMB145LR · Windshield/Door Rain/Ice RemovalSDR ASOA201905274021Charger · inoperativeIAH - THE FLIGHT ATTENDANT REPORTED THAT THE EXIT SIGN ABOVE THE EXIT ROW WAS NOT ILLUMINATING, AND THE AISLE PATH LIGHTING FROM ROWS 19-24 WERE FOUND INOPERATIVE AS WELL DURING MX INSPECTION. THE #4 EMERGENCY LIGHT BATTERY PACK AND CHARGER WERE REMOVED AND REMay 27, 2019 · N14907 · Emb EMB145LR · Emergency LightingSDR ASOA201905274020Battery · dischargedIAH - THE FLIGHT ATTENDANT REPORTED THAT THE EXIT SIGN ABOVE THE EXIT ROW WAS NOT ILLUMINATING, AND THE AISLE PATH LIGHTING FROM ROWS 19-24 WERE FOUND INOPERATIVE AS WELL DURING MX INSPECTION. THE #4 EMERGENCY LIGHT BATTERY PACK AND CHARGER WERE REMOVED AND REMay 27, 2019 · N14907 · Emb EMB145LR · Emergency LightingSDR SIMA20190526005Door Sill · corrodedCARGO DOOR SILL CORRODED AT NUT PLATE HOLE. C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW SRM 51-40-02 AND SRM 51-20-03.May 26, 2019 · N653AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190526004Door Sill · corrodedSERVICE DOOR CENTER SILL CORRODED AROUND SERVAL NUTPLATES. C/A-REMOVED AND REPLACE SERVICEABLE SERVICE DOOR CENTER SILL IAW SRM 51-40-02.May 26, 2019 · N653AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2019052900156Wire · brokenNDIS 683 33-51 0011610 26MAY19 RIC CLOSE SERVICE DOOR EMERGENCY LIGHT ON HONGE INOP FACT 26MAY19 11:23 RIC FOUND #2 BATT SUPPLY FAULTY AND GROUND WIRE BROKEN AFTER SPLICE SP7377. R/R #2 BATT SUPPLY IAW AMM TASK 33-50-04-000/400-801-A. REPAIRED WIREMay 26, 2019 · N683AE · Emb EMB145LR · Light System WiringSDR SIMA20190526003Charger · inoperativeGALLEY EMER LIGHTS AND FLOOR STRIPS 1-3 INOP. C/A-REMOVED AND REPLACED #2 EMERGENCY BATTERY AND CHARGER IAW W/C 33-700-19. PERFORMED OPS CHECK IAW W/C 33-700-17. OPC GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 113277May 26, 2019 · N677AE · Emb EMB145LR · Emergency LightingSDR ASOA201905264023Rail · faultyICT - FLIGHT 4378, THE FLIGHT ATTENDANT REPORTED A METAL BURNING SMELL IN GALLEY THAT STARTED GOING AWAY WHEN FLIGHT ATTENDANT TURNED OFF THE COFFEE POTS. THE COFFEE POTS WERE PLACED ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 05/28/19 IAH May 26, 2019 · N14904 · Emb EMB145LR · Buffet/GalleysSDR ASOA201905264022Rail · faultyICT - FLIGHT 4378, THE FLIGHT ATTENDANT REPORTED A METAL BURNING SMELL IN GALLEY THAT STARTED GOING AWAY WHEN FLIGHT ATTENDANT TURNED OFF THE COFFEE POTS. THE COFFEE POTS WERE PLACED ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 05/28/19 IAHMay 26, 2019 · N14904 · Emb EMB145LR · Buffet/GalleysSDR SIMA20190525004Light · damagedLT FLOOR PROXIMITY STRIP LIGHTS #8 STRIP LIGHTING ASSY IS DAMAGED. C/A-COMPLETE: REPLACED LIGHT STRIP IAW AMM 33-50-12.May 25, 2019 · N662EH · Emb EMB145LR · Emergency LightingSDR SIMA20190525003Light · damagedRT FLOOR PROXIMITY STRIP HAS DAMAGED RT FWD PROFILE. C/A-COMPLETE: INSTALLED NEW RT FLOOR PROXIMITY SIDEWALL ASSY. IAW AMM 33-50-12.May 25, 2019 · N662EH · Emb EMB145LR · Emergency LightingSDR SIMA201906125002Skin · damagedTDMI-662T5574 FOUND HOLE MID/AFT RUDDER II-ERS-EM-55DF-756 PTC-C/A-ERS-EM-55DF-756 HAS BEEN SUPERCEEDED BY ERS-EM-55MR-764 RUDDER II REPAIRED IAW ERS-EM-55MR-764 REF AML PG 4430639 ITEM 1, TDMI RESTOREDMay 25, 2019 · N662EH · Emb EMB145LR · Rudder, Plate/SkinSDR SIMA201906125001Skin · chafedRUDDER II R/H SKIN IS CHAFFED ON THE INTERIOR AROUND RIB 1419.0 (3RD FROM BOTTOM) TRAILING EDGE-C/A-REPAIRED RUDDER II R/H SKIN IAW ERS-EM-55MR-763May 25, 2019 · N662EH · Emb EMB145LR · Rudder, Plate/SkinSDR HNAA2019052900155Light · inoperativeNDIS 639 33-51 0011920 25MAY19 RIC CLOSE EMER FLOOR STRIP @ SEAT 14 & 15A INOP 32622 00 BRA ACT 25MAY19 11:39 RIC R/R THE EMERGENCY FLOOR PROXIMITY STRIP AT SEAT 14 &15A IN REF TO AMM 33-50-12-000/400-801-A OPS CHECK GOOD OK FOR SERVICE P/N LIGHMay 25, 2019 · N639AE · Emb EMB145LR · Emergency LightingSDR HNAA2019052900151Switch · faulty645 05-50 1881141 25MAY19 CLT CLOSE ELECTRICAL SMELL IN FLT DECK DURING TAXI OUT. 29593 00 VAG FACT 25MAY19 15:50 CLT R\R #2 PACK OVERTEMP SWITCH RAN A/C WITH BOTH PACK OPS CHECK GOOD OK FOR SERVICE.May 25, 2019 · N645AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2019052900154Sign · inoperative628 33-51 0017630 24MAY19 RIC CLOSE EXIT SIGN ABOVE SERVICE DOOR DOES NOT ILLUMINATE 28916 00 BAD FACT 24MAY19 12:51 RIC R/R EXIT MARKING SIGN IN REF TO AMM 33-50-14-000/400-801-A. OPS CHECK GOOD. OK FOR SERVICE. P/N ON EXIT MARKER 1013834 P/NMay 24, 2019 · N628AE · Emb EMB145LR · Emergency LightingSDR SIMA20190524002Valve · failedPAC 1 VALVE FAIL IN FLIGHT; PAC 1 & 2 OVLD IN FLIGHT; BURNING SMELL IN COCKPIT. SMELLED LIKE BURNT PLASTIC. NO COMPLAINTS OF BURNING SMELL IN CABIN. NO SMOKE OBSERVED IN COCKPIT. C/A-REMOVED AND REPLACED #1 PACK VALVE IAW AMM 21-51-01. PERFORMED OPERATIONAL TEMay 24, 2019 · N616AE · Emb EMB145LR · Cabin Cooling SystemSDR SIMA2019060423004Support · crackedBAGGAGE DOOR AFT TORSION BAR MECHANISM CENTER SUPPORT BRACKET IS CRACKED. -C/A-REMOVED AND REPLACED BAGGAGE DOOR AFT TORSION BAR MECHANISM CENTER SUPPORT BRAKET IAW SRM 51-40-02.May 23, 2019 · N670AE · Emb EMB145LR · Cargo/Baggage DoorsSDR RAIA201905230001Seal · damagedRETURN FROM FLIGHT DUE TO BANGING ON OUTSIDE OF AIRCRAFT. POSSIBLE CAPT WINDSHIELD SEAL TORN. INSPECTED AND FOUND BANGING TO BE COMING FROM CAPT'S HUMPSEAL. DEFERED HUMPSEAL. MORE INFORMATION PROVIDED WHEN AVAILIBLE. SUPPLIMENTAL INFORMATION FROM FIRST ENTRY. May 23, 2019 · N844HK · Emb EMB145LR · Flight Compartment WindowsSDR ASOA201905235071Control Module · odorPILOT REORTED BURNING ELECTRIC SMELL COMIING FROM OVERHEAD LIGHTS IN THE GALLEY. MX REMOVED AND REPLACED THE GALLEY CONTROL MODULE IAW AMM 33-29-01 OPS CHECK GOOD PERFORMED OPERATIONAL CHECK ON BOTH COFFEE MAKERS IAW VCMM 25-30-39 OPS CHECK GOOD NO SMELL NOTEDMay 23, 2019 · N14904 · Emb EMB145LR · Passenger Compartment LightingSDR HNAA2019052700150Switch · malfunctioned658 36-12 1880731 23MAY19 ROA CLOSE ON T/O ROLL AT APROX 50KNOTS BLEED 1 VALVE FAIL MESSAGE DISPLAYED AND DURING ABORT NO TAKEOFF CONFIG WARNING SOUNDED MOMENTARILY AND CANCELED WITHOUT CREW INPUT. 24930 00 SMK HISTORY: FACT 23MAY19 10:52 ROA R May 23, 2019 · N658AE · Emb EMB145LR · Pneumatic Distribution SystemSDR HNAA2019052700149Unknown · odor624 21-01 2045341 23MAY19 PHL CLOSE ELECTRIC BURNING SMELL IN COCKPIT AT 23K FT. ICING SYSTEM BRIEFLY CAME ON. ODOR DISSIPATED AT 20K FT DESCENDING. 27371 00 JJC FACT 23MAY19 16:01 PHL INSPECTED AND SMELL CHECKED BOTH RELAY PANELS L/R, NOSE AVIONMay 23, 2019 · N624AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20190523001Brake · leaking3767 DFW-SGF N909 SMOKING BRAKES WHILE LANDING NUMBER 2 BRAKE LEAKING FLUID HE DID NOT DECLARE EMERGENCY BUT CFR FOLLOWED HIM INTO GATE. C/A-RAR #2 BRAKE IAW W/C 32-600-14 OPC AND LEAK CHECK GOOD.May 23, 2019 · N909AE · Emb EMB145LR · BrakeSDR SIMA20190523003Skin · gouged4238 ORF-ORD N902 AIRCRAFT DAMAGE ON RT FUSELAGE 2 SCRATCHES ON LOWERCASE "A" ON RIGHT SIDE OF AIRCRAFT. C/A-INSPECTED TWO GOUGES ON LOWERCASE "A" OF AMERICAN LOGO ON RT FUSELAGE, IAW SRM 53-22-01. SEE ITEM#2 AT THIS AML PAGE FOR CORRECTIVE ACTION.May 23, 2019 · N902BC · Emb EMB145LR · Fuselage Main, Plate/SkinSDR ASOA201905237050Frame · chafedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND CHAFFING FROM A SCREW AT FRAME 70 BETWEEN STRINGER 12R AND 13R. MAINTENANCE REPAIRED THE CHAFE AREA FROM STR.12R TO 13R IAW ETD 2019-145-066859. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.May 23, 2019 · N16987 · Emb EMB145LR · Fuselage Main, FrameSDR ASOA201905237049Trunnion · crackedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND THE LT MLG AFT TRUNION CRACKED. MAINTENANCE REMOVED AND REPLACED THE LT TRUNION ON THE LT MLG AFT SIDE IAW ECTC ETD 2019-145-068830. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE C-CHECK.May 23, 2019 · N16987 · Emb EMB145LR · Fuselage, Landing Gear Attach FittingsSDR SIMA20190522003Light · not reportedEXTERNAL EMERGENCY LIGHTS OF THE RT SIDE FORWARD LOWER FAIRING - REMOVAL/ INSTALLATION. C/A-RAR EXTERNAL EMERGENY LIGHT IAW AMM TASK 33-50-10-04.May 22, 2019 · N677AE · Emb EMB145LR · Emergency LightingSDR SIMA20190522004Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOP. C/A-RAR MAIN DOOR EMERGENCY LT LAMP IAW AMM 33-50-06-000-801-A AND AMM 33-50-06-400-801-A. OPC GOOD. NO MORE DEFECTS NOTED AT THIS TIME. END.May 22, 2019 · N611AE · Emb EMB145LR · Emergency LightingSDR RAIA201905220001Angle · crackedLT ANGLE CRACKED AT FR 19 RAMP FLOOR. REMOVED & REPLACED ANGLE.May 22, 2019 · N842HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA2019060421005Support · crackedPAX DOOR INNER HANDLE LOCK BOX SUPPORT IS CRACKED. -C/A-REMOVED AND REPLACED PAX DOOR INNER HANDLE LOCK BOX SUPPORT BRACKET IAW SRM 51-42-02.May 21, 2019 · N670AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA2019060421007Beam · crackedCARGO DOOR CUTOUT SILL IS CORRODED. -C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW SRM 51-40-02.May 21, 2019 · N670AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA2019060421006Crossbeam · crackedCROSSMEMBER ON THE AFT SIDE OF NLG UPLOCK BOX HAS A 1 1/2" CRACK.-C/A-REPLACED CROSSMEMBER ON AFT SIDE OF NLG UPLOCK BOX IAW SRM 51-40-02.May 21, 2019 · N670AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20190521003Skin · damagedTRANSFERRED FROM AML PAGE 4391436 ITEM 2" SEE ITEM 1 LOGPAGE 4391435FOUND DAMAGE BETWEEN FRAME 61-64 AND STRINGER 19L AND 20L. MULTIPLE DENTS AND SCRATCHES NOTED. INSPECTED AND FOUND INTERNAL STRUCTURE TO BE A SERVICEABLE CONDITION . MAJOR REPAIR-C/A-REPAIRED May 21, 2019 · N673AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20190521004Light · malfunctionedEMERGENCY LIGHT STRIPS 4 & 5 AND BOTH EMERGENCY EXIT SURROUND PANEL LIGHTS COME ON AND GO OUT. C/A-C/W EMERGENCY LIGHTING ADUJSTMENT/TEST IAW AMM 33-50-00. NO DEFECTS NOTED AT THIS TIME.May 21, 2019 · N673AE · Emb EMB145LR · Emergency LightingSDR SIMA20190521001Light · inoperativeLT OVERWING EMERGENCY LIGHT INOP. C/A-RAR LT OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED.May 21, 2019 · N933JN · Emb EMB145LR · Emergency LightingSDR SIMA2019060420003Support · crackedBAGGAGE DOOR AFT TORSION BAR SUPPORT BRACKET APPEARS TO BE CRACKED.-C/A-REMOVED AND REPLACED BAGGAGE DOOR AFT TORSION BAR SUPPORT BRACKET IAW SRM 51-40-02May 20, 2019 · N670AE · Emb EMB145LR · Cargo/Baggage DoorsSDR ASOA201905205070Controller · faultyWINDSHIELD HEAT 2 FAIL ON T/O LOUD CLICKING FROM RELAY FOLLOWED BY STRONG BURNT SMELL. REMOVED AND REPLACED WINDSHIELD NR 2 TEMP CONTROLLER IAW AMM 30-42-01. OPS CHECK IS GOOD A/C WAS APPROVED FOR RETURN TO SERVICE.May 20, 2019 · N11539 · Emb EMB145LR · Windshield/Door Rain/Ice RemovalSDR HNAA2019052200148Acm · malfunctionedPDIS 630 21-01 2097683 20MAY19 GSO CLOSE IN CRUISE FLIGHT AT 25K BOTH FLIGHT DECK AND CABIN EXPERIENCED LIGHT SMOKE. C/W QRH PROCEDURE AND SMOKE DISSIPATED 24934 00 EK HISTORY: FACT 21MAY19 12:02 GSO R&R NR 1 AIR CYCLE MACHIINE IAW 21-51-03. OPMay 20, 2019 · N630AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2019052200146Flow Sensor · defective647 73-30 2007141 19MAY19 CHS CLOSE NR 1 ENG FUEL FLOW WENT TO ZERO ON EICAS AND RMU DURING T/O ROLL. HISTORY: NONE MEL 19MAY19 10:55 CHS C13909 73-6 FUEL FLOW INDICATORS FACT 21MAY19 04:59 PHL R&R RUEL FLOW SENSOR IAW MM 73-35-10. OPSMay 19, 2019 · N647AE · Emb EMB145LR · Fuel Flow IndicatingSDR SIMA20190519002Light · inoperativeWING TO FUSELAGE EMERG LIGHT LT AFT INOP. C/A-WING TO FUSELAGE LT AFT EMERG LIGHT RELAMPED IAW AMM 33-50-10 OPC GOOD.May 19, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190519004Light · inoperativeAFT AISLE EMERGENCY LIGHT INOP. C/A-AFT AISLE EMERGENCY LIGHT BULB REPLACED IAW AMM 33-50-08. LIGHTING TEST GOOD.May 19, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190519003Inverter · inoperativeAFT 3 EMERGENCY FLOOR STRIPS INOP. C/A-REMOVED AND REPLACED NR 6 INVERTER IAW AMM 33-50-11 OPS CHECK GOOD.May 19, 2019 · N612AE · Emb EMB145LR · Emergency LightingSDR RAIA201905180001Acm · seizedLACK OF CABIN PRESSURIZATION @FL250 DESCEND TO FL110 DUE TO RAPID DECOMPRESSION---FOUND PACK 2 ACM SEIZED. R&R'D PACK 2 ACM. OPS CHECK GOOD. PRESSURIZATION OPS CHECK GOOD.May 18, 2019 · N843HK · Emb EMB145LR · Cabin Cooling SystemSDR RAIA201905170001Clamp · brokenON CLIMBOUT AND ACFT CONFIGURED FOR FULL THRUST, BLEED 1 LOW TEMP IN ICING CONDITIONS. FOUND BROKEN CLAMP ON NR 1 FAN AIR VALVE, R&R CLAMP AND SWAPPED NR 1 AND NR 2 FAN AIR VALVES OPS TEST GOOD. JUMPED RELAYS I21/I22 FOR BLEED OPS CHECK, AFTER SWAPPING FAN AIRMay 17, 2019 · N832HK · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20190517002Cradle · brokenAFT CABIN FLASHLIGHT CRADLE BROKEN. C/A-REMOVED AND REPLACED AFT FLASHLIGHT CRADLE IAW AMM TASK 33-50-16-000-801-A AND 33-50-16-400-801-A.May 17, 2019 · N616AE · Emb EMB145LR · Emergency EquipmentSDR SIMA2019060416006Bracket · crackedFWD TORSION BAR BRACKET AT FRAME 61 FOR CARGO DOOR HAS A 1/8" CRACK. -C/A-REMOVED AND REPLACED FWD TORSION BAR BRACKET AT FRAME 61 IAW SRM 51-40-02.May 16, 2019 · N670AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA2019060416007Channel · crackedR/H HAT BEAM SUPPORT IS CRACKED BETWEEN FRS 47 AND 48. -C/A-INSTALLED NEW R/H SUPPORT IAW SRM 51-40-02.May 16, 2019 · N670AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2019052200147Hydraulic Line · brokenPDIS 637 29-13 1734641 16MAY19 MDT CLOSE NR 1 HYD QTY IN AMBER AND DROPPING TO ZERO INFLIGHT HYD QTY DROPPED TO ZERO AND FLIGHT REMIANED FOR APPROX 20 MINS. CREW C/W QRH. FACT 16MAY19 12:38 MDT REMOVED AND REPLACED BROKEN HYDRAULIC LINE ON #1 HYDRAMay 16, 2019 · N637AE · Emb EMB145LR · Hydraulic System, Main
Back to Embraer EMB-145LR