SDR SIMA2019040104Connector · brokenDURING INSTALLATION OF FLOOR PANEL 261BF FOUND FLOOR PROXIMITY STRIP LIGHT WIRE CONNECTOR BROKEN.-C/A-INSTALLED MISSING SPLICE MALE CONNECTOR IN FLOOR PROXIMITY STRIP LIGHT #8 IAW EMB 145 AMM 20-00-03. OPS CHECK GOOD IAW EMB145 AMM 33-50-12SDR ASOA201903275046Acm · seizedCREW REPORT SMOKE IN CABIN DURING CLIMBOUT. CLEARED AFTER SHUTTING OFF PACK 1. SMELL OF SMOKE BEFORE BEFORE PACK 1 OVERLOADED AND SHUT DOWN. AIR RETURNED. FLT 4304. CONTRACT MX FOUND ACM SHAFT/BEARINGS DAMAGED AND PLACED ON MEL. 03/29/19 XJT EWR MX REMOVED & RSDR HNAA2019032800081Unknown · odorPDIS 637 05-50 2016111 27MAR19 BTV CLOSE ELECTRICAL BURNING FUME DETECTED IN CRUISE FLT. SMELL OCCURRED TWICE THEN DISSIPATED AND DID NOT RETURN. HISTORY: YES FACT 27MAR19 13:23 BTV OPERATED BOTH BLEED SYSTEMS AND PACKS INDEPENDENTLY NO ODORS DETECTESDR SIMA20190327002Unknown · malfunctionedDURING LANDING WHILE BRAKING FROM 100 KIAS-80KIAS BRAKE SURGING AT ONE PER TIRE ROTATION. SIMILAR TO ANTI-SKID ENGAUGING AND DISENGAUGING."TRANSFERRED TO NRWC 931-ORD-03974". C/A-PERFORMED BRAKE ASSEMBLY INSPECTION ON ALL MLG BRAKE ASSEMBLIES IAW AMM 32-49-03SDR SIMA20190327001Roller · lack of lubeDIFFICULTY OPENING MAIN CABIN DOOR. C/A-LUBED MAIN DOOR FRAME ROLLERS IAW MM 53-21-02.SDR ASOA201903263022Rib · crackedDURING "C" CHECK INSPECTION FOUND LEFT WING RIB 21 CRACKED. MAINTENANCE REPAIRED RIB 21 I/A/W SRM 57-20-07.SDR SIMA201903276001A/C Pack · dirtySUPPLEMENTAL PACKS SMELL DIRTY, ENGINE BLEEDS SUPPLYING AIR ON TAXI + APU SUPPLYING AIR AT GATE STILL SMELLED UNDER THOSE CONDITIONS. "TRANSFERRED TO NRWC 689-ORD-03890"-C/A-C/W ETN# ETN-EM-72-034, DEFERRED PACK 1. T/S PACK 1 DIRTY SMELL PER FIM 21-20-00-810-8SDR HNAA2019032800080Unknown · odorPDIS 637 05-50 2016101 26MAR19 CLT CLOSE ELECTRICAL BURN SMELL ON FLT DECK FACT 26MAR19 19:29 CLT INSPECTED AND OPS CK ACFT FOR ELECTRICAL BURN SMELL. NONE FOUNND. C/W ENG BLEED OPS CK, AVIONICS EQUIP OPS CK. OK FOR SERVICE.SDR SIMA20190325001Condenser · failedSUPPLEMENTAL SMOKE IN CABIN CLIMBING THROUGH ~ 19000 FT "TRANSFERRED TO NRWC 613-MIA-02438". PACK 2 OVLD ON LANDING. C/A-REMOVED AND REPLACED NR 2 ACM IAW AMM 21-51-03 REF AML #436403812 & NRWC 613-MIA-02436 FOR WORK PERFORMED. ALSO REMOVED AND REPLACED NR 2 CSDR HNAA2019032800079Connector · dirtyNDIS 642 33-51 0003890 24MAR19 RIC CLOSE EMERGENCY LIGHT AT SEAT 3B WILL NOT ILLLUMINATE FACT 24MAR19 09:39 RIC CLEANED AND RESECURED EMERGENCY LIGHT CONNECTORS FOR EMERGENCY LIGHT AT SEAT 3B IN REF TO AMM 32-50-14-000-701/400-801-A. OPS CHECK GOODSDR HNAA2019032800078Sign · malfunctionedNDIS 628 33-51 0016010 24MAR19 SBY CLOSE EMERGENCY EXIT SIGN ABOVE SERVICE DOOR DOES NOT ILLUMINATE DURING OPS CHECK.
FACT 24MAR19 10:35 SBY CYCLED EMERGENCY LIGHTS EMERGENCY EXIT SIGN ABOVE SERVICE DOOR NOW ILLUMINATES. OPS CHECK GOOD.SDR ASOA201903247034Skin · corrodedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND FUSELAGE CORRODED UNDER THE RA ANTENNA BETWEEN FRAMES 69 AND 70 AND STR 21L AND 21R. MAINTENANCE PERFORMED A DOUBLER ON THE FUSELAGE BELOW THE RA ANTENNA AT FRAMES 69 AND 70 IAW SRM 53-00-23. ALL WORK ACCOMPLISHED ASDR ASOA201903247033Structure · gougedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND A SMALL GAUGED ON FACE OF THE FLANGE AT FR. 35 AND STRINGER 16L. MAINTENANCE REPAIRED THE AREA AT FR.35 AND STR. 16L IAW SRM 53-00-04 FIG. 206. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.SDR SIMA20190323006Connector · brokenFOUND LAST:LT FLOOR PROXIMITY EMERGENCY LIGHT (CLOSES TO THE LAV DOOR) HAS A BROKEN CONNECTOR. C/A-COMPLETE:REPLACED FLOOR PROX EMERGENCY LIGHT CONNECTOR IAW SWPM 20-21-00.SDR SIMA20190323003Light · damagedFOUND FLOOR EMERGENCY LIGHT STRIPS SIDEWALL ASSEMBLIES CRACKED, CHIPPED AND BROKEN BROKEN. C/A-COMPLETE:RAR FLOOR EMERGENCY LIGHT STRIPS IAW AMM 33-50-12.SDR SIMA20190323004Light · defectiveLT FLOOR PROXIMITY EMERGENCY LIGHT (IN THE FLOOR) AT FRM54. CONNECTOR WILL NOT CONNECT WITH THE PROX LIGHT CONNECTOR. C/A-COMPLETE: REPLACED LT FLOOR PROX EMERGENCY LIGHT @ FR54 IAW SWPM 20-21-00.SDR SIMA20190323005Wire · brokenLT FLOOR PROXIMITY EMERGENCY LIGHT WIRE BROKEN AT FRM54. C/A-COMPLETE: REPAIRED LT FLOOR PROXIMITY EMERGENCY LIGHT WIRE IAW SWPM 20-21-00.SDR SIMA20190322005Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP. C/A-RAR EXTERNA EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A OPS CHECK GOOD.SDR SIMA20190322004Wire · brokenNR 4 EMERGENCY FLOOR STRIP LIGHT CONNECTION WIRES BROKEN. C/A-REMOVED AND REPLACED NR 4 EMERGENCY FLOOR STRIP LIGHT ASSEMBLY IAW AMM 33-50-12. OPERATIONAL CHECK GOOD.SDR SIMA20190322001Floor Support · corrodedLT OMEGA BEAM CORRODED AT CROSS BEAM FRAME 44. C/A-REPAIRED THE LT OMEGA BEAM CORROSION AT CROSS BEAM FRAME 44 IAW ERS-EM-53MR-3712.SDR RAIA201903210001Switch · out of adjustBAGGAGE DOOR INDICATING OPEN IN FLIGHT. DEFERED BAGGAGE DOOR INDICATION. INSPECTED AND FOUND AFT MICRO SWITCH OUT OF LIMITS. ADJUSTED SWITCH. OPS CHECK GOOD.SDR SIMA20190321002Light · inoperativeEXT OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED NR 4 BATTERY CHARGER ASSEMBLY. OPS CHECK FAILED. DEFERRED AFT EXTERNAL EMERGENCY LIGHTS AS PER MEL 33-29 AUTH# 030740D-C. REMOVED AND REPLACED BATTERY CHARGER NR 4 DID NOT FIX. REMOVED AND REPLACED RSDR SIMA20190321003Light · inoperativeROW 12 OVERHEAD EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED ROW 12 AISLE EMERGENCY LIGHT LAMP IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD NO DEFECTS NOTED. END.SDR SIMA20190321001Wire · damagedEMERGENCY LIGHT STRIP AT ROW 1-3 INOP. C/A-REPAIRED EMERGENCY LIGHT STRIP WIRING IAW SWPM 20-21-00. OPS CHECK GOOD NO FURTHER DEFECTS FOUND.SDR SIMA20190320007Switch · failedPACK 1 OVERLOAD WITH PACK 2 PREVEUSLY MEL. C/A-DEFERRED PER MEL 21-29 AUTH 030669DM-C. "M" PROCEDURES C/W. LT PACK OPS CK GOOD IAW AMM 21-51-00. MEL RESTORED. REMOVED AND REPLACED RT PACK OVER TEMP SWITCH IAW AMM 21-51-08 OPS AND LEAK CHECK SATISFACTORY. MEL RSDR SIMA20190320005Flashlight · inoperativeSUPPLEMENTAL AFT FA FLASHLIGHT INOP. C/A-FLIGHT CREW PLACARDED AFT FLIGHT ATTENDENT FLASHLIGHT // TEMP INSTALLED AUTH 030706-C REF 25-53 MOC 630997. REMOVED AND REPLACED AFT FA FLASHLIGHT IAW AMM 33-50-16. OPS CHECK GOOD MEL RESTORED.SDR SIMA20190320006Light · inoperativeMAIN-DOOR EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED MAIN-DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-06-000-801-A AND AMM 33-50-06-400-801-A. OPS CHECK GOOD. NO MORE DEFECTS NOTED AT THIS TIME. END.SDR SIMA20190320004Connector · brokenLT NR 8 FLOOR PROXIMITY LIGHT CONNECTORS MISSING ON AIRCRAFT SIDE. C/A-INSTALLED NEW CONNECTORS ON WIRES W192-8832-22 AND W192-8833-22 IAW SWPM 20-21-00.SDR SIMA20190320003Wire · brokenNR 1 EMERGENCY LIGHT STRIP HAS ONE BROKEN WIRE ON AIRCRAFT SIDE. C/A-REPAIRED WIRE W192-8630-22 AT NR 1 LIGHT STRIP IAW SWPM 20-21-00.SDR HNAA2019032100077Track · dirtyPDIS 683 52-10 1854172 20MAR19 PWM CLOSE MAIN PAX DOOR, UNABLE TO OPEN. HISTORY: NO FACT 20MAR19 21:26 PHL CLEANED AND LUBED PASSENGER DOOR TRACKS AND LATCHES AS REQUIRED. OPS CHECK GOOD. OKAY FOR SERVICE.SDR HNAA2019032100076Anti-Ice System · malfunctioned614 21-01 2099092 20MAR19 PHL ASSGN DURING CRUISE CREW SMELLED ODOR IN COCKPIT, SELECTED W/S HEAT OFF, ODOR DISAPPEARED. UPON TURNING W/S HEAT BACK ON, NOTICED HIGHER THAN NORMAL ELECTRICAL DRAW ON W/S HEAT 2. MAINTENANCE R&R GLARESHIELD AND NUMBER 2 WSDR HNAA2019032100075Warning System · false activationPDIS 652 52-40 1931872 18MAR19 PHL CLOSE ON TAKEOFF ROLL SERVICE DOOR OPEN EICAS MSG DISPLAYED. HISTORY:
FACT 18MAR19 22:17 PHL INSP SERVICE DOOR FOR DEFECTS W NONE NOTED. SERVICE DOOR OPERATES NORMALLY AT THIS TIME OKAY FOR SERVICE.SDR SIMA20190317002Light · inoperativeOVERHEAD EMERGENCY LIGHT NR 3 FROM FWD IN CEILING PANEL INOP. C/A-REMOVED AND REPLACED OVERHEAD EMERGENCY LIGHT NR 3 FROM FWD BULB IAW AMM 33-50-08 OPS CHECK GOOD.SDR SIMA20190317001Connector · dirtyWHILE PERFORMING W/C 33-700-17 EMERGENCY LIGHTING SYS OPS CHECK FOUND RT OVER WING EXIT LIGHT INOP. C/A-CLEANED ELECTRICAL CONNECTORS AT NR 3 EMERGENCY LIGHTING POWER SUPPLY AND NR 4 AND NR 5 EMERGENCY LIGHTING AC/DC INVERTERS IAW AMM 33-50-04 AND 33-50-11. OPSDR SIMA20190316001Control Unit · failedPUT GEAR DOWN ON FINAL INTO SHV BRAKE DEGRADED EICAS MSG. C/A-INTEREGRATED CMC, NO MSG FOUND. REMOVED AND REPLACED BCU IAW AMM, 32-41-02.OPS GOOD. PERFORMED HIGH SPEED TAXI WITH CREW, OBSERVED ALL BRAKE TEMP IN NORMAL. AIRCRAFT OK FOR SERVICE.SDR SIMA20190315002Strut · lowLG AIR/GND ON TAKE OFF COULDNT RETRACT LANDING GEAR. C/A-FOUND NOSE LG STRUT TO BE BELOW LIMITS. SERVICED NOSE LG STRUT IAW WC 32-600-06. PERFORMED OPS CHECK OF LG IAW AMM 32-34-00 OPS CHECK GOOD. T/S IAW FIM 32-63-00. PERFORMED OPC GOOD OF LANDING GEAR IAW AMSDR SIMA20190315001Tube · defectiveBLD 1 LEAK INFLIGHT. "TRANSFERRED TO NRWC 606-ORD-02422" MM 841029. C/A- REMOVE AND REPLACED LT TUBE ASSY FWD OF PACK NR 1 VALVE PER AMM 36-11-09. PERFORMED OPC OF AIR BLEED SYS PER AMM 36-00-00. OPS CHECK AND LEAK CHECK GOOD.SDR ASOA201903157032Skin · dentedTYS A/C IS IN C-CHECK WHEN A FUR 5700-01510,DEFECT BO27891 RT L/E 1 WAS DENTED AND REQUIRED A PERMANENT REPAIR. MAINTENANCE CUT OUT THE DAMAGE AREA ,FABRICATED A FILLER(.071) AND A DOUBLER OF SAME MATERIAL AND INSTALLED IAW SRM 57-40-00. ALL WORK ACCOMPLISHED SDR SIMA20190314004Door Sill · corrodedSERVICE DOOR SILL IS CORRODED. C/A-COMPLETED INSTALLATION OF SERVICE DOOR SILL IAW SRM 51-40-02.SDR SIMA20190314002Panel · damagedEMERGENCY LIGHT PANEL ON MAIN DOOR DAMAGED. C/A-REMOVED AND REPLACED EMERGENCY LIGHT PANEL ON MAIN DOOR, OPC GOOD, IAW AMM 25-23-04.SDR SIMA20190314003Power Supply · inoperativeDURING PS-1 CHECK FOUND BOTH AFT OVER THE WING EMERGENCY LIGHTS NOT WORKING. C/A-REMOVED AND REPLACED NR 4 EMERGENCY BATTERY PACK AND POWER SUPPLY IAW AMM 33-50-04, OPS CHECK IAW AMM 33-50-00-700-801-A. OPS CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1ASMISDR HNAA2019031600073Unknown · malfunctionedPDIS 645 21-30 1907392 14MAR19 ROA CLOSE AT FLT LEVEL 250 CABIN GOT WARM IN BACK, CAPT LOWERED TEMP AND WENT INTO MANUAL MODE AT WHICH POINT PACK 1 CLOSED. CABIN ALTITUDE SHOT FROM 4000 TO 7000 FT IN SECONDS. STARTED DECENDING PACK 1 CAME ON AND DIVERTED TO ROSDR SIMA20190313004Bracket · excess playAFTER TAKEOFF LG AIR/GND FAIL ON EICAS, MESSAGE DID NOT GO AWAY, UPON LANDING EVERYTHING WORKED AS NORMAL "TRANSFERRED TO NRWC 902-MIA-03838". C/A-REMOVED AND REPLACED LT MLG DOOR SUPPORT/PROX SWITCH BRACKET IAW CMM 32-10-01. INSTALLED LT MLG DOOR FITTING ASSYSDR HNAA2019031600074Light · looseNDIS 690 33-40 0008520 13MAR19 SBY CLOSE RT OVER WING EMERGENCY LIGHT IS INOP. 35719 00 SMC FACT 13MAR19 09:25 SBY R&R LIGHT BULB FOR RT EMERGENCY OVER WING LIGHT, NO FIX. INSPECTED ASSEMBLY AND FOUND LIGHT BULB TO BE LOOSE IN CONNECTOR. R&R OVER WING EMSDR SIMA20190312001Support Bracket · crackedRT. O/B OMEGA BEAM SUPPORT BRACKET HAS A 1/4" CRACK BETWEEN FRAMES 48-49. -C/A-REMOVED AND REPLACED RT OUTBD OMEGA BEAM SUPPORT BRACKET IAW SRM 51-40-02.SDR SIMA20190311002Battery · dischargedEMERGENCY EXIT SIGN LEFT SIDE INOP (UPPER SIGN). C/A-REMOVED AND REPLACED #3 EMERGENCY LIGHTING BATTERY AND POWER SUPPLY IAW AMM 33-50-04 OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 15185SDR SIMA20190311001Cradle · defectiveAFT CABIN FLASHLIGHT WON'T STAY SECURE IN CRADLE. C/A-REMOVED AND REPLACED AFT FLASHLIGHT CRADLE ASSY IAW AMM 33-50-16.OPS CHK GOOD.SDR SIMA20190310004Skin · crackedRT FUSELAGE SKIN CRACKED AT FR 12A STR 6R. C/A-PERFORMED PERMANENT REPAIR RT FUSELAGE SKIN CRACKED AT FR 12A STR 6R IAW ERS-EM-53MR-3701.SDR SIMA20190310003Skin · crackedRT WINDSHIELD LATERAL POST UPPER SKIN CRACKED BETWEEN WINDSHIELD AND DV WINDOW OPENING. C/A-PERFORMED PERMANENT REPAIR ON RT WINDSHIELD LATERAL POST UPPER SKIN CRACKED BETWEEN WINDSHIELD AND DV WINDOW OPENING IAW ERS-EM-53MR-3701.SDR HNAA2019031100072Light · inoperativeNDIS 647 33-51 0006820 06MAR19 ROA CLOSE LT, FWD EMERGENCY LIGHT IS INOP FACT 06MAR19 10:47 ROA R&R THE LAMP/BULB ON THE LT, FWD EMERG LIGHT OPS CHECK GOOD OKAY FOR SERVICE AT THIS TIME PART INSTALLED/REMOVED LAMP/BULB - 8330012 SN N/A.