Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201904075050Engine · leakingODOR OF RUBBER GETTING HOT WHILE THRUST LEVERS IN THE DETENT. MX R & R THE NR 1 ENGINE, OPS AND LEAK CHECKED GOOD. OCF SUCCESSFUL. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2019041075050Unknown · odorPILOT REPORTED "ODOR OF RUBBER GETTING HOT WHILE THRUST LEVERS WERE IN THE DETENT. NO SMOKE OR FIRE, BUT ODOR PRESENT". AIR RETURN.SDR ASOA2019041073024Floor Support · corrodedDURING C CHECK INSPECTION FOUND CORROSION ON FLOORBOARD SUPPORT FRAME 71 STRINGER 17R. MAINTENANCE REPLACED LEFT AFT FLOOR SILL.SDR HNAA2019040900092Fire Warning · false activationPDIS 630 26-15 2055741 07APR19 PHL CLOSE
ON TAXI OUT MASTER WARNING TRIPLE CHIME EICAS MESSAGE BAG SMOKE. FIRE EXTINGUSHER BAG BUTTON ILLUMINATED
.CREW PERFORMED MEMORY ITEMS (RELEASED EXTIG AGENT)RAN QRH FA PERFORMED VISUAL INSPECTION.FSDR SIMA201904087002Inverter · inoperativeRIGHT OVERWING EXIT MARKER INOP. REMOVED & REPLACED #5 INVERTER, RIGHT OVERWING EXIT MARKER OPERATES OK IAW EMB AMM 33-50-11.SDR ASOA2019041063023Gusset · corrodedDURING C CHECK INSPECTION FOUND CENTER FLOOR BEAM GUSSET CORRODED AROUND NUTPLATE HOLES FROM FRAME 58-61. MAINTENANCE REPLACED CENTER FLOOR BEAM GUSSET.SDR HNAA2019041300099Skin · corrodedDURING HVY CHK MAINTENANCE FOUND CORROSION ON FUSELAGE INTERNAL SKIN UNDER FR 61 TEAR STRAP BETWEEN STGR 17L-18L. REPAIRED IAW SRM 53-31-01SDR SIMA201904084007Fitting · chafedLH AILERON DAMPNER FITTING HAS CHAFING MARKS ON THE INSIDES OF TH FITTING. LH AILERON FITTING TO PCA HAS (2EA) INBD MIGRATED HAT BUSHINGS. -C/A-REMOVED AND REPLACED LH AILERON DAMPNER FITTING IAW EO-EM-27MR-112. RAR'D PCA ATTACH FITTING (INCLUDES HAT BUSHINSDR HNAA2019040700090Sleeve · torn604 36-21 2049321 04APR19 CLT CLOSE
AT 8000 FT BLD 1 LEAK WARNING MSG ON EICAS, FOLLOWED QRH, SHUT OFF CROSSFEED AND PUSH OUT AFFECTED BLD SWITCH, MSG EXTINGUISHED AFTER 4 MINUTES. NO ICING.
25056 00SDR SIMA201904054002Oxygen Mask · brokenFO OXYGEN MASK BROKE IN FLIGHT DURING USEING TO RELIEVE CA FOR THE LAV.-C/A-REMOVED AND REPLACED FO'S O2 MASK OPS CHECK GOOD LEAK CHECK GOOD IAW AMM CH 35-10-10.SDR SIMA201904054004Unknown · odorCREW OF FLT #3658 ALSO REPORT OF SMELL OF PLASTIC BURNING IN THE CABIN SEE LOG PAGE 4459778 ITEM 1 AND 2 FOR CREW INF.-C/A-C/W ETN EM-72-034 NO SMELL OF PLASTIC BURNING OR ABNORMAL SMELL NOTEDSDR SIMA20190404001Bushing · migratedRH AILERON DAMPER FITTING HAD MIGRATED HAT BUSHING. RAR RH AILERON DAMPER FITTING IAW EO- EM-27MR-112.SDR SIMA201904083002Frame · corrodedFRAME 22 RT CORRODED AT FLOOR LEVEL. C/W REPAIR OF FR 22R IAW SRM 53-00-04RE AND 51-40-02.SDR SIMA201904053001Firewall · canningAPU FIREWALL AT RH UPPER CORNER IS OIL CANNING-C/A-REPAIRED APU FIREWALL IAW ERS-EM-49MR-141SDR HNAA2019040400089Bulb · inoperativeDIS 604 33-51 0024070 03APR19 SBY CLOSE
R/H OVER WING EMERGENCY EXIT LIGHT IS INOP.
27617 00 SPE
FACT 03APR19 10:09 SBY
R & R R/H OVERWING EMERGENCY EXIT LIGHT BULB IAW
SDR HNAA2019041100098Rod End · damagedR/H AILERON ACTUATOR ROD END FITTING O/B HAT BUSHING HOLE OVERSIZED FOUND IN HVY CHK. INSTALLED BUSHING PER SRM 51-20-09SDR HNAA2019040400087Lever · malfunctionedPDIS 649 32-30 2050593 02APR19 PHL CLOSE
ON CLIMBOUT, LG/LEVER DISAGREE WARNING EICAS MESSAGE C/W QRH, OPS NORMAL.
31575 00 LLS
FACT 02APR19 05:10 PHL
T/S I.A.W EMB 145 FIM 32=32-00SDR HNAA2019040700091Door Sill · corrodedDURING HVY CHK MAINTENANCE FOUND CORROSION AROUND SERVICE DOOR FWD SILL NUT PLATE HOLES. R&R.SDR HNAA2019040400088Contactor · faulted656 30-41 1919182 01APR19 PHL CLOSE
WINDSHIELD HEAT 1 INOP EICAS MSG
27626 00 RNR
HISTORY: 31MAR (3X)
FACT 01APR19 06:46 ALB
TROUBLESHOT WS HEAT 1 INOP MSG PER EMB145 FIM TASKSDR SIMA201904021006Cradle · brokenFWD CABIN FLASHLIGHT CRADLE BROKEN-C/A-REMOVED AND REPLACED FWD CABIN FLASHLIGHT ASSY, OPC GOOD IAW EMB AMM 33-50-16SDR SIMA201904010101Light · inoperativeSERVICE DOOR EMERGENCY LIGHT IN CEILING PANEL INOP-C/A-REMOVED AND REPLACED EMERGENCY LIGHT IAW AMM 33-50-13SDR RAIA2019040833101Firewall · crackedAPU FIREWALL AFT FACE IS CRACKED AT A FRAME LOWER R/H MOUNT. REMOVED AND REPLACED APU FIREWALLSDR ASOA201904051548Unknown · odorCREW REPORTED A BURNING SMELL AT SEAT 11D SIDEWALL. MX RAN ENGINES WITH CREW AND COULD NOT DUPLICATE FAULT. REMOVED AND REPLACED CABIN RECIRCULATION FAN AND MUFFLER WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2019040435048Unknown · odorFLT 4147 CREW REPORTED BURNING SMELL AT SEAT 11D SIDEWALL AND AIR RETURNED BACK TO DEPARTURE. OPENSDR SIMA2019040122001Warning Message · false indicationCABIN ALT DISPLAYED AMBER DASHES ON DEPARTURE, INDICATION RETURNED DURING DESCENT.-C/A-AT THIS TIME C/W OPS CK ON MANUAL PRESS. SYST PER AMM 21-31-00, FOUND SYST WORKING PROPERLY.SDR HNAA2019040100086A/C Pack · odorPDIS 669 21-01 1929651 31MAR19 TYS ASSGN
ABNORMAL ODOR PRESSENT ON FLT DECK WITH PACK 1 ON, N
O ODOR IN CABIN
24934 00 EK
HISTORY: YES
MEL 31MAR19 15:45 TYS C09011 21-13-2SDR HNAA2019040100085Unknown · odorMDIS 669 21-01 1929643 31MAR19 TYS CLOSE
TROUBLESHOT ELECTRICAL ODOR REF. LOG PAGE 192964 SEQ 2
FACT 31MAR19 01:24 TYS
VISUALLY INSPECTED FLIGHT COMPARTMENT RELAYS AS WELL
AS POWER DISTRIBUTION RELAYS NO OBVIOUS DEFECTS OR BURN ODORS SDR SIMA2019040130001Windshield · failedFO SIDE WINDOW SHATTERED. REMOVED AND REPLACED FO WINDSHIELD IAW AMM 56-10-01. LEAK CHECK GOOD. OPS CHECK OF W/S HEATING SYSTEM GOOD IAW EMB 145 AMM 30-42-00. OPS CHECK OF W/S WIPER SYS GOOD IAW AMM 30-41-00.SDR HNAA2019040100084Unknown · odorPDIS 669 21-01 1929642 30MAR19 TYS CLOSE
DURING CLIMBOUT AT 22000 FT, NOTICED ELECTRICAL ODOR IN FLIGHT COMPARTMENT, SMELL DISSAPATED AFTER REACH
ING PAGE S-8 ON QRH.
FACT 31MAR19 12:01 TYS
INSP.'D LEFT AND RIGHT RELAY PSDR ASOA2019043093029Shear Tie · crackedDURING C CHECK INSPECTION, FOUND CRACKED SHEAR CLIP AT FRAME 75 JUST LEFT OF STRINGER 2L. MAINTENANCE REPLACED SHEAR CLIP AT FRAME 75 JUST LEFT OF STRINGER 2L.SDR ASOA201903293028Shear Tie · crackedDURING C CHECK INSPECTION FOUND SHEAR CLIP AT FRAME 80 BETWEEN STRINGER 5R AND 7R CRACKED. MAINTENANCE REPLACED SHEAR CLIP AT FRAME 80 BETWEEN STRINGER 5R AND 7R.SDR HNAA2019041300100Skin · dentedDISCREPANCY: DURING HVY CHK MAINTENANCE FOUND CARGO DOOR EXTERNAL SKIN HAS A DENT WITH A GOUGE ON THE FWD LOWER CORNER. CORRECTIVE ACTION: REPAIRED IAW ETD2019-145-044683SDR ASOA2019041239325Channel · corrodedDURING C CHECK INSPECTION FOUND LONGITUDINAL "Z" CHANNEL ON TOLIET WASTE VALVE SUPPORT CORRODED. MAINTENANCE REPLACED Z CHANNEL ON TOLIET WASTE VALVE SUPPORTSDR HNAA2019041100097Housing · crackedDURING HVY CHECK CARGO DOOR EXTERNAL HANDLE CUTOUT IS CRACKED AT THE END. REPAIRED IAW SRM 52-30-01RE.SDR SIMA2019040432909Door Sill · corrodedNUMEROUS SPOTS OF CORROSION ON CARGO SILL BETWEEN FRAMES 65 TO 68. -C/A-C/W RAR OF CARGO DOOR SILL IAW SRM 51-40-02.SDR ASOA2019040329547Fan · failedPILOT REPORTED "SMOKE SMELL IN THE CABIN AND COCKPIT GOT BETTER ONCE PACK #1 TURNED OFF. MX INSPECTED AND FOUND #1 RECIRCULATION FAN MUFFLER BLOWN AND DAMAGED AND PARTIALLY DAMGAED MUFFLER ON RECIRCULATION FAN #2. REMOVED AND REPLACED BOTH MUFFLERS SYSTME OPS SDR SIMA20190401903Light · inoperativeAISLE EMERGENCY LIGHT AT 3A INOP.-C/A-REMOVED AND REPLACED AISLE EMERGENCY LIGHT AT 3A, OPC GOOD IAW AMM 33-50-08SDR SIMA201904011005Cradle · damagedFA FLASHLIGHT HOLDER NOT HOLDING FLASHLIGHT PROPERLY.-C/A-REMOVED AND REPLACED FWD CABIN FLASHLIGHT HOLDER ASSY IAW EMB145 AMM 33-50-16. OPS CHECK GOOD.SDR SIMA20190401104Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-LH FWD OVERWING EMERGENCY LIGHT RELAMPED IAW EMB 145 AMM 33-50-10, OPS CHK. GOODSDR SIMA20190401101Warning Light · false indicationPACK 1 OVERLOAD DURING T/O ROLL. T/S PACK 1 OVERLOAD PER FIM TASK EMB145 FIM 21-51-00-810-801A STEPS 1-3 FOUND TO BE A TRANSITORY CONDITION OF THE A/C SYSTEM. PERFORMED OP CK OF THE A/C SYSTEM IAW EMB 145AMM 21-51-00 NO DEFECTS NOTEDSDR HNAA2019040100083Control Valve · malfunctionedPDIS 636 21-60 1938091 29MAR19 PWM CLOSE
PACK 2 AUTO TEMP CONTROL UNRESPONSIVE TO PILOT CONTR
OLS. MANUAL DOES NOT PROPERLY CONTROL TEMP. MANUAL O
NLY EFFECTIVE AT 9 OCLOCK OR LESS POSITION.
FACT 30MAR19 11:19 PHL
SDR ASOA201904017035Frame · crackedCRACKED FRAME RT SIDE ABOVE RT WINDSHIELD LATERAL POST. REMOVED CRACKED SECTION OF LATERAL BRACKET, INSTALLED NEW SECTION OF LATERAL BRACKET AND DOUBLER. AIRCRAFT STILL IN C CHECK.SDR SIMA2019040832807Support · crackedBAGGAGE DOOR MECHANISM FORWARD SUPPORT IS CRACKED. INSTALLED NEW SUPPORT IAW SRM 51-10-02.SDR SIMA2019040432806Shear Tie · crackedFRAME 68 SHEAR CLIP BETWEEN STR 7L AND 8L HAS 1 CRACK. ( 1,5 INCH TOTAL CRACK LENGTH) -C/A-INSTALLED FR68 SHEAR CLIP IAW SRM 51-40-02SDR SIMA2019040432805Shear Tie · crackedFRAME 73 SHEAR CLIP AT STRINGER 10L HAS 2 CRACKS. (1.5 INCH TOTAL CRACK LENGTH)-C/A-REPLACED SHEAR CLIP IAW SRM 51-40-02SDR SIMA2019040432804Support · crackedCARGO DOOR HOLD OPEN SUPPORT REINFORCEMENT AT FRAME 68 STRINGER 15L HAS 2 CRACKS. (1 INCH IN LENGTH TOTAL)-C/A-REPLACED SUPPORT REINFORCEMENT IAW SRM 51-40-02SDR SIMA201904013Intercostal · crackedNLG FORWARD INTERCOSTAL CRACKED-C/A-REPLACED INTERCOSTAL IAW SRM 51-40-02.SDR SIMA201904012Wire · broken#8 EMERGENCY LIGHT STRIP WIRE BROKEN-C/A-REMOVED AND REPLACED # 8 EMERGENCY LIGHT STRIP IAW EMB 145 AMM 33-50-12.SDR HNAA2019033000082Light · inoperativeNDIS 637 33-51 0022940 28MAR19 SBY CLOSE FWD EMERGENCY LIGHT ON RT SIDE INOP. FACT 28MAR19 10:24 SBY R & R FWD EMERGENCY LIGHT ON RT SIDE IAW AMM 33-50-10 P/N ON/OFF 8330012 LAMP.SDR SIMA2019040100003Fitting · migratedL/H AILERON DAMPNER FITTING BUSHING IS MIGRATING. -C/A-REMOVED AND REPLACED LH AILERON PER AMM 27-10-00.
Back to Embraer EMB-145LR