SDR UHLA201606010290Gate · out of adjustMAIN CABIN DOOR HAS LARGE GAP AT TOP SEAL. RED ALIGN MARKS SLIGHTLY OFF. ADJUSTED MAIN CABIN DOOR FOLDING FLAP IAW AMM 52-10-01.SDR SIMA20160601001Inverter · inoperativeRIGHT INSIDE SIDEWALL WING EMERGENCY EXIT LIGHT INOPERATIVE. R & R NR 5 EMERGENCY LIGHT INVERTER. OPS CHECKED GOOD IAW AMM 33-50-11.SDR RAIA201605310001Proximity Switch · inoperativeLANDING GEAR AIR TO GROUND ON EICAS AND E1-2 DISAGREE. REPLACED NOSE PROXIMITY SWITCH AND SERVICED NOSE STRUT, OPS CHECK GOOD.SDR SIMA20160531006Sign · inoperativeFOUND FWD FACING EMER EXIT CEILING LIGHT INOPERATIVE. R & R FWD FACING EMER EXIT CEILING LIGHT IAW AMM 33-50-15.SDR SIMA20160531001Unknown · malfunctionedEMERGENCY LIGHTS ON AFTER BATTERIES OFF WITH EMER LIGHTS SWITCH IN OFF POSITION. SHUT OFF GPU & REBOOTED ACFT APU, EMER LIGHTS WENT OFF AFTER SHUTTING OFF ALL ACFT POWER. OPERATIONS CHECKED GOOD.SDR SIMA20160531003Stop Fitting · corrodedBAGGAGE DOOR FWD DOOR STOP HAS CORROSION AROUND 3 NUTPLATES. PERFORMED REPAIR OF BAGGAGE DOOR FWD DOOR STOP CORROSION IAW ERS-EM-52MR-554.SDR SIMA20160531005Wire · brokenLEFT NR 6 EMER LIGHT STRIP WIRE BROKEN. R & R LT NR 6 EMER LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160531004Connector · missingNUMBER 6 EMER LIGHT STRIP ACFT SIDE MISSING CONNECTOR. INSTALLED SERVICEABLE CONNECTOR ON NR 6 EMER LIGHT STRIP ACFT SIDE IAW SWPM 20-21-00.SDR SIMA20160530001Door Seal · dirtyFLIGHT ATTENDANT ADVISES MAIN CABIN DOOR IS DIFFICULT TO OPEN. CLEANED MAIN DOOR SEAL IAW 52-10-04. NO DEFECTS NOTED.SDR ASOA20160528052Acm · damagedTHE CREW REPORTED SMOKE COMING FROM THE F/O'S SIDE VENT. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE ACFT AND FOUND THE NR 1 ACM TO BE DAMAGED. THE ACFT WAS SUBSEQUENTLY FERRIED TO WHERE MAINTENANCE R & R THE NRSDR SIMA20160527004Sign · inoperativeEMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT INOPERATIVE. R & R EMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT IAW AMM 33-50-13, OPS CK GOOD.SDR SIMA20160527005Wire · brokenLEFT NR 4 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE. R & R LT NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12. OPS CK GOOD IAW AMM 33-50-00.SDR SIMA20160527003Cradle · crackedFLIGHT ATTENDANT FLASHLIGHT CRADLE CRACKED. R & R FLIGHT ATTENDANT FLASHLIGHT CRADLE IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR ASOA20160527030Fitting · crackedDURING C-CHECK, THE RT LOWER FWD ENGINE YOKE FITTING WAS FOUND TO BE CRACKED AND VERIFIED WITH EDDY CURRENT. MAINTENANCE R & R THE FITTING IAW EC5450-01206. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160526005Light · damagedEMERGENCY LIGHT STRIP NR 5 DAMAGED. R & R EMERGENCY LIGHT STRIP NR 5 ON EXTRUSION IAW AMM 33-50-12, NRTC BOW219649 FOR EXTRUSION INSTALL AND OPS CHECK.SDR SIMA20160526004Skin · crackedLEFT REAR FUSELAGE SKIN, NEW CRACK LOCATIONS AT FRAME 77 - 79. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-2107.SDR SIMA20160526002Inverter · inoperativeLAST THREE FLOOR PROXIMITY STRIPS INOPERATIVE. R & R NR 6 ELS INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20160526003Air Duct · defectiveIN CLIMB WING ANTI-ICE FAIL ON EICAS, NO OPEN INSCRIPTION, RAN CHECKLIST CYCLED SWITCH, NO EFFECT. FLIGHT ATTENDANT REPORTED ICE ON ENGS WITH NO INDICATION OF ICE CONDITIONS AFTER CLEARING INITIAL ICE CONDITIONS. R & R NR 2 HEAT EXCHANGER DUCT ASSEMBLY & GRASDR SIMA20160526001Roller · defectiveFLIGHT ATTENDANT REPORT MAIN DOOR IS EXTREMELY DIFFICULT TO OPEN. PERFORMED MAIN DOOR FRAME ROLLER SERVICING IAW MM 53-21-02. OPERATIONS CHECKED GOOD.SDR ASOA20160525033Control Panel · faultyTHE CREW REPORTED THE EMERGENCY LIGHT ARMING ON AND OFF. OVERHEAD CABIN LIGHTS ALSO FLICKERING. MAINTENANCE INSPECTED AND REPLACED THE F/A CONTROL PANEL. OPS CHECKS WERE GOOD.SDR ASOA2016F00133Battery Pack · inoperativeDURING EMERGENCY LIGHT SYSTEM CHECK, THE FORWARD MAIN ENTRY EMERGENCY LIGHTS FAILED TO ILLUMINATE. MAINTENANCE R & R NR 1 EMERGENCY LIGHT BATTERY PACK. OPS CHECKS WERE GOOD.SDR UHLA201605250264Spring · damagedF/A ADVISES STAIRS SLAM FLAT WHEN RAISING MCD. R & R SPRINGS ON TOP OF MCD IAW AMM 52-10-07. OPS CHECK GOOD.SDR SIMA20160525001Flashlight · inoperativeAFT FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. DEFERRED FLASHLIGHT IAW MEL 25-53, M PROCEDURES COMPLIED WITH. INSTALLED FLASHLIGHT ASSY ON AFT CABIN OPS CHECK GOOD IAW EMB 145 MM 33-50-16. MEL RESTOREDSDR SIMA20160524003Skin · crackedLEFT REAR FUSELAGE I SKIN CRACKS AT FRAME 75, BETWEEN STRINGERS 1L & 2L. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-2103.SDR SIMA20160524004Skin · crackedRIGHT REAR FUSELAGE I SKIN CRACKS AT FRAME 75, BETWEEN STRINGERS 1R & 2R. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-2104.SDR RAIA201605240001Line · failedON TAKEOFF, RECEIVED A LANDING GEAR DISAGREE MESSAGE AND HYD SYS 1 FAIL AND HYDRAULIC SYS 1 LOW QTY. INSPECTED AND FOUND LT MLG ACTUATOR HYDRAULIC LINE FAILED. R & R HYD LINE PERFORMED OPS CHECK OF GEAR. OPS AND LEAK CHECK GOOD.SDR SIMA20160523001Roller · lack of lubeMAIN CABIN DOOR HARD TO OPERATE. LUBED MAIN CABIN DOOR ROLLERS IAW AMM 53-21-02. OPERATIONS CHECKED GOOD.SDR SIMA20160523003Wire · brokenEMERGENCY LIGHT INOPERATIVE ON SERVICE DOOR. REPAIRED BROKEN WIRES ON SERVICE DOOR EMERGENCY LIGHT ASSEMBLY IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20160523006Light · inoperativeRIGHT OVERWING EMER LIGHT INOPERATIVE. R & R RT OVERWING EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20160523002Controller · failedSTRANGE ODOR ALMOST LIKE A BURNING PLASTIC ODOR CAME & THEN WENT AWAY. TROUBLE SHOT SMELL IAW FIM 21-20-00-810-801-A FOUND NR 1 WINDSHIELD TEMP CONTROLLER TO BE BAD. REF ITEM 1 OF THIS LOG PAGE FOR R & R. R & R WINDSHIELD TEMPERATURE CONTROLLER FOR THE NR 1SDR SIMA20160523005Connector · disconnectedCENTER AISLE EMER EXIT REAR OF SIGN INOPERATIVE. FOUND CONNECTOR UNPLUGGED, SECURED CONNECTOR IAW AMM 33-50-15-400-801. OPERATIONS CHECKED GOOD.SDR SIMA20160522005Indication Sys · malfunctionedDESCENT LOSS OF AIRSPEED INDICATIONS ON FIRST OFFICERS PFD. PERFORMED OPERATIONAL CHECK OF AIR DATA COMPUTER SYS IAW AMM 34-15-00. OPERATIONS CHECKED GOOD.SDR SIMA20160522004Hydraulic System · lowNUMBER 1 HYD QTY LOW INFLIGHT. SERVICED NR 1 HYD SYS IAW AMM 12-13-01. ACFT OK FOR SERVICE.SDR SIMA20160522002Contactor · malfunctionedABOUT 5 SECONDS AFTER SELECTING ENG 1 TO STOP WHILE PULLING INTO GATE SAW & HEARD ELEC ARCHING THOUGH SCREEN PANEL DIRECTLY BEHIND FIRST OFFICERS SEAT. ELEC BURNING SMELL FOLLOWED, NO ABNORMAL MSGS OR INDICATIONS ON EICAS OR ELEC PAGE ON MFD. R & R CONTACTORSDR SIMA20160522001Pump · leakingHYDRAULIC SYS 1 LO QTY AT CRUISE FL 350. FLIGHT CREW DECLARED EMER. RETURN TO FIELD. UPON PERFORMING LEAK INSPECTION FOUND NR 2 EDP LEAKING. SERVICED SYS 1 HYD IAW AMM 12-13-01. NO LEAKS FOUND. R & R NR 2 EDP IAW AMM 29-10-03. OPERATIONS CHECKED GOOD LESDR SIMA20160522003Flashlight · dimREAR CABIN FLIGHT ATTENDANT FLASHLIGHT VERY DIM. BATTERY NEEDS REPLACEMENT. R & R REAR CABIN FLIGHT ATTENDANT FLASHLIGHT AS REQUIRED. NO FURTHER DEFECTS NOTED.SDR ASOA20160522050Inverter · inoperativeFLIGHT CREW REPORTED THAT THE EMERGENCY LIGHT ON THE BULKHEAD AT SEAT 3D WAS INOPERATIVE. THE ACFT WAS FERRIED WHERE MAINTENANCE R & R THE NR 3 EMERGENCY LIGHT INVERTER, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVISDR ASOA20160521024Wire · unsecureCREW SMOKE REPORTED COMING FROM SIDEWALL LIGHT LAST ROW. MAINTENANCE SECURED THE WIRE AND OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR HNAA2016052400148Unknown · odorUPON LEVELING OUT FROM DESCENT WHEN THRUST LEVER ADVANCED, SMOKE ODOR COMING FROM VENTS. POSSIBLE ELECTRICAL SMOKE ODOR FOR 1-2 MINUTES. INSPECTED ACFT. GROUND POWER RAN ACFT IN TAKEOFF AND CRUISE CONDITIONS FOR SEVERAL MINUTES. OPS CK GOOD NO DEFECTS NOTEDSDR SIMA20160520007Angle · corrodedBAGGAGE DOOR LOWER ANGLE HAS CORROSION AROUND 4 NUTPLATES. PERFORMED REPAIR OF BAGGAGE DOOR LOWER ANGLE CORROSION IAW ERS-EM-52MR-555.SDR SIMA20160520002Shroud · defectiveMAIN PAX DOOR EMER EXIT LIGHT INOPERATIVE. R & R PAX DOOR HINGE EMER LIGHT SHROUD IAW AMM 25-23-04 STEPS 3 I 1 F-I. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20160520005Inverter · inoperativeAFT EXIT LOCATING SIGN INOPERATIVE. R & R NR 4 EMER LIGHT AC & DC INVERTER IAW 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20160520004Light · inoperativeMAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R MAIN CABIN DOOR EMER LIGHT IAW AMM 33-50-06-000-801-A & 33-50-06-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20160520003Power Supply · inoperativeLEFT & RIGHT OVERWING EMER LIGHTING INOPERATIVE. TROUBLE SHOT LT & RT OVERWING EMER LIGHTING & ISOLATED PROBLEM TO EMER BATTERY POWER SUPPLY. R & R EMER BATTERY POWER SUPPLY IAW AMM-33-50-04.SDR RAIA201605200002Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 7, LIGHT NR 16B, IS INOPERATIVE. R & R BULB IN CEILING EMERGENCY EXIT LIGHT AT ROW 7, LIGHT NR 16B. OPS CHECKED GOOD.SDR RAIA201605200001Bulb · inoperativeEXTERIOR EMERGENCY EXIT LIGHT IN FRONT OF RT WING, LIGHT NR 4, IS INOPERATIVE. R & R BULB IN EXTERIOR EMERGENCY EXIT LIGHT IN FRONT OF RT WING, LIGHT NR 4. OPS CHECK GOOD.SDR SIMA20160520001Connector · missingNUMBER 3 EMER LIGHT STRIP CONNECTOR ON ACFT SIDE MISSING. FOUND DURING CLOSE UP. INSTALLED SERVICEABLE SPLICE SP9036 ON NR 3 EMER LIGHT STRIP CONNECTOR ON ACFT SIDE IAW SWPM 20-21-00.SDR SIMA20160519003Control Unit · faultyWHEN TAXING OUT NOTICED RT BRAKE WAS NOT WORKING, THEN GOT BRAKE DEGRADED MSG. REPLACED BRAKE CONTROL UNIT IAW 32-41-02 AMM. OPERATIONS CHECKED GOOD.SDR SIMA20160519001Roller · lack of lubeFLIGHT ATTENDANT HAS DIFFICULT TIME CLOSING THE MAIN DOOR. THE TOP PART OF THE DOOR STAYS OPEN. LUBED AIRFRAME DOOR ROLLERS. PERFORMED OPERATIONS CHECK OF MAIN PAX DOOR IAW AMM 52-18-00. OPERATIONS CHECKED GOOD.SDR UHLA201605180244Seal · damagedLARGE GAP IN UPPER LT CORNER OF MAIN CABIN DOOR SEAL, WHEN CLOSED. FOUND MISSING SEALANT ON DOOR SEAL. APPLIED SEALANT TO UPPER LT CORNER OF MAIN CABIN DOOR IAW AMM 52-10-04. OPS CHECK GOOD.
Back to Embraer EMB-145LR