What was found
ON TAKEOFF, RECEIVED A LANDING GEAR DISAGREE MESSAGE AND HYD SYS 1 FAIL AND HYDRAULIC SYS 1 LOW QTY. INSPECTED AND FOUND LT MLG ACTUATOR HYDRAULIC LINE FAILED. R & R HYD LINE PERFORMED OPS CHECK OF GEAR. OPS AND LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON TAKEOFF, RECEIVED A LANDING GEAR DISAGREE MESSAGE AND HYD SYS 1 FAIL AND HYDRAULIC SYS 1 LOW QTY. INSPECTED AND FOUND LT MLG ACTUATOR HYDRAULIC LINE FAILED. R & R HYD LINE PERFORMED OPS CHECK OF GEAR. OPS AND LEAK CHECK GOOD.