Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UHLA201602260075Stop · damagedAIR START DOES NOT DEPLOY. R & R MAIN DOOR STEP FOLD-OUT BACKSTOP IAW AMM 52-13-02. OPS CHECK GOOD.SDR SIMA20160226001Holder · brokenFORWARD FLIGHT ATTENDANT FLASHLIGHT HOLDER IS BROKEN & DOES NOT HOLD FLASHLIGHT PROPERLY. R & R FLASHLIGHT ASSEMBLY IAW AMM 33-50-16, NO DEFECT NOTED.SDR UHLA201602250076Hand Rail · inoperativeMAIN ENTRY DDOOR HANDRAIL DOES NOT STOW WHEN CLOSED. RETORQUED MAIN CABIN DOOR HAND RAIL IAW AMM 52-10-05. OPS CHECK GOOD.SDR ASOA20160225014Battery Pack · dischargedDURING PREFLIGHT IT WAS REPORTED THAT THE FWD EMERGENCY LIGHT WAS INOPERATIVE. THE EMERGENCY LIGHT BATTERIES WERE CHARGED, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2016022500001Battery Pack · dischargedDURING PREFLIGHT IT WAS REPORTED THAT THE FWD EMERGENCY LIGHT WAS INOPERATIVE. THE EMERGENCY LIGHT BATTERIES WERE CHARGED, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160225002Sensor · malfunctionedANTI-ICE DUE FLAPS FAIL ON EICAS, DECLARED AN EMERGENCY. R & R RT FLAP VELOCITY SENSOR IAW MM 27-51-12. OPERATIONS CHECKED GOOD. IAW NRWC-655-02425 & NRWC-655-0246.SDR SIMA20160224003Flashlight · inoperativeAFT CABIN EMER FLASHLIGHT INOPERATIVE. R & R AFT CABIN FLASHLIGHT IAW AMM 25-60-00. OPERATIONS CHECKED GOOD AT THIS TIME. FLASHLIGHT BATTERY PN P4-01-1003-001.SDR SIMA20160224002Light · inoperativeMAIN DOOR OVERHEAD EMER LIGHT INOPERATIVE. REPLACED MAIN DOOR OVERHEAD EMER LIGHT IAW AMM 33-26-05-000-801-A & 33-26-05-400-801-A.SDR SIMA20160223002Skin · corrodedE492453 INTERNAL SKIN CORRODED, BETWEEN FRAME 13 - 14, STRINGER 21L - 20L. PERFORMED PERMANENT REPAIR OF INTERNAL SKIN CORROSION IAW ERS- EM-53MR-1933.SDR SIMA20160223001Inverter · inoperativeFORWARD EMER FLOOR STRIP INOPERATIVE. R & R EMER LIGHTING INVERTOR NR 2 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR ASOA20160222009VBeam · corrodedDURING C-CHECK, BOLT HOLES FOR CTR 3 PIECE TRIM ON PLANE AREA CORRODED INTERNALLY. R & R CARGO DOOR CUTOUT LOWER BEAM IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR SIMA20160221004Connector · brokenEMERGENCY LIGHT STRIP NR 5 HAS BROKEN CONNECTOR AT FLOOR. REPLACED CONNECTOR ON EMER LIGHT STRIP NR 5 IAW SWPM 20-21-00. SEE WIPS & TASKS FOR DETAILS OF WORK PERFORMED.SDR RAIA201602210001Ground Stud · missingAUTO PRESSURIZATION FAIL REVERTED TO MANUAL AND IT WAS UNRESPONSIVE. FOUND GROUND CONNECTION VALVE TO BE MISSING. INSTALLED GROUND CONNECTION FLAPPER COVER. OPS CHECK GOOD. INSPECTED DUCKING FOR FOD.SDR SIMA20160221003Skin · dentedRIGHT RVSM AREA HAS DAMAGE, DENT, BETWEEN FRAME 12A & 13, JUST BELOW & AFT OF OXYGEN SERVICE PANEL. REPAIRED DAMAGE, BETWEEN FRAME 12A & 13, JUST BELOW & AFT OF OXYGEN SERVICE PANEL IAW SRM 53-00-22.SDR SIMA20160221001Door Seal · damagedLOUD SQUEAL FROM MAIN CABIN DOOR WHEN DIFFERENTIAL PRESS IS BELOW 4.6 PSI. TRANSFERRED TO NRWC 628-ORD-02495. REPAIRED LOWER AFT MAIN DOOR FRAME SEAL IAW AMM 52-21-01. LEAK CHECKED GOOD. TRANSFERRED FROM NWRC 628-ORD-02495.SDR SIMA20160220001Fcu · failedFUEL 1 LO LEVEL EICAS TANK 1 FUEL QTY ZERO, ABORT TAKEOFF. INSPECTED MAIN GEAR FOR A.B.T.O, NO DEFECTS NOTED. INSPECTED LT WING FOR FUEL LEAK, NO DEFECTS NOTED. TROUBLE SHOT IAW FIM 28-41-00-810-840. R & R FCU IAW AMM 28-41-01. OPERATIONS CHECKED GOOD.SDR SIMA20160219002Skin · crackedLEFT REAR FUSELAGE I SKIN CRACKS AT FRAME 75, BETWEEN STRINGERS 1L & 3L. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1951.SDR ASOA20160223009Skin · dentedTHE RT RUDDER 2 SKIN HAS 2 DENTS WITH CREASES. CUT OUT DAMAGED SECTION OF SKIN AND INSTALLED FILLER AND DOUBLER IAW ETD2016-017022. AIRCRAFT RELEASED AND RETURNED TO SERVICE.SDR SIMA20160219001Charger · failedLEFT & RIGHT EXTERIOR OVERWING EMER LIGHTS FAILED TO ILLUMINATE. R & R NR 4 EMER LIGHT CHARGER ASSEMBLY & BATTERY ASSEMBLY IAW AMM 33-50-04. OPERATIONS CHECKED IAW AMM 33-50-0. OPERATIONS CHECKED GOOD. EMER LIGHTING BATTERY PN 2013-1A & SN 125752.SDR RAIA201602190001Bulb · inoperativeRIGHT WING OVERWING EMERGENCY LIGHT INOPERATIVE. R & R RT WING OVERWING EMERGENCY LIGHT BULB. OPS CHECK GOOD.SDR SIMA20160218003Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED AT FRAME 75, THE FIRST FASTENER BELOW STRINGER 2R. REPAIRED RT UPPER FUSELAGE SKIN CRACK IAW ERS-EM-53MR-1930.SDR SIMA20160218004Skin · crackedLEFT UPPER FUSELAGE SKIN CRACKED AFT OF FRAME 75 & ABOVE STRINGER 2L. REPAIRED LT UPPER FUSELAGE SKIN CRACK IAW ERS-EM-53MR-1930.SDR SIMA20160218002Switch · failedIN LEVEL CRUSE AT FL 250, FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN WITH SOME ORDER IN THE COCKPIT. DID NOT LOCATE THE SOURCE, SUBSIDED AFTER A FEW MINUTES, DIVERTED. INSPECTED ACFT & PERFORMED ETN-EM-72-034. FOUND PACK 1 TO BE INOPERATIVE WITH PNEUMATICSDR SIMA20160216002Light · brokenEMERGENCY FLOOR STRIP NR 1 ASSEMBLY IS BROKEN. R & R EMER FLOOR STRIP NR 1 ASSEMBLY IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR ASOA20160216008TUnknown · odorACFT HAD A STRONG BURNING ODOR IN ACFT IN THE FLIGHT DECK AND CABIN. EMERGENCY DECLARED AIR RETURN. ODOR STARTED AFTER TAKEOFF. MAINTENANCE PLACED ON DMI, OPERATE IAW MEL 21-1-00-1, CAT C. PLACARD INSTALLED.SDR RAIA201602150003Smoke Warning · false activationLAVATORY SMOKE WARNING IN FLIGHT WITH SMOKE IN CABIN. UNABLE TO DUPLICATE SMOKE.SDR RAIA201602150001Bulb · inoperativePASSENGER DOOR EMERGENCY FLOOD LIGHT NR 1 INOPERATIVE. R & R PAX DOOR EMERGENCY FLOOD LIGHT BULB. OPS CHECK GOOD.SDR SIMA20160215003Floor Support · corrodedRIGHT OMEGA BEAM, BETWEEN FRAME 18 & 18 IS CORRODED. REPAIRED RT OMEGA BEAM AT FRAME 18 NUTPLATE IAW ERS-EM-53MR-1906.SDR SIMA20160215001Fitting · gougedRIGHT AILERON DAMPENER FITTING IS GOUGED. R & R DAMPENER FITTING ON THE RT AILERON IAW EO EM-27MR-112.SDR SIMA20160215002Door · lack of lubeFLIGHT ATTENDANTS REPORTS THE MAIN CABIN DOOR NOT OPEN OR CLOSE EASILY. CLEANED & LUBRICATED MAIN DOOR IAW AMM 52-18-00. OPERATIONS CHECKED GOOD AT THIS TIME.SDR ASOA20160214009HBattery Pack · dischargedDURING MAINTENANCE INSPECTION THE ALL OF THE EMERGENCY LIGHTS THAT OPERATE OFF OF BATTERY NR 4 WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 4 BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160214001Transducer · malfunctionedE1 ANTI-ICE FAIL CAUTION ON EICAS FOLLOWED BY E1 ANTI-ICE OVER PRESSURE ADVISORY. R & R NR 1 PRESS TRANSDUCER IAW AMM 30-21-06. OPS CHECKED GOOD.SDR SIMA20160213002Light · inoperativeMAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R LAMP IN MAIN CABIN DOOR EMER LIGHT IAW AMM 33-50-06. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20160213004Light · inoperativeRIGHT OVERWING EXTERIOR EMER LIGHT INOPERATIVE. R & R RT OVERWING EXTERIOR EMER LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20160213005Flashlight · inoperativeCAPTAINS EMER FLASHLIGHT INOPERATIVE. R & R CAPTAINS EMER FLASHLIGHT LAMP IAW CMM 25-60-11. OPERATIONS CHECKED GOOD.SDR SIMA20160213001Flap · malfunctionedFLAP FAIL AFTER TAKEOFF AT FLAP 9 DEGREES, OBSERVED FAULT CODE 27M0100. RESET & OPERATIONS CHECKED FLAPS IAW AMM 27-53-00-5. OPERATIONS CHECKED GOOD, NO DEFECTS OR RELATED CMC MSGS NOTED.SDR ASOA20160212013CLight · inoperativeDURING ROUTINE MAINTENANCE THE NR 3 EMERGENCY FLOOR PROXIMITY LIGHT STRIP WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE NR 3 EMERGENCY FLOOR LIGHT STRIP. OPS CHECKS WERE GOOD.SDR UHLA201602120059Hand Rail · malfunctionedPAX DOOR HANDRAILS DON'T STOW WITH DOOR CLOSED. CLEANED HANDRAIL ASSY, REPLACED ASSIST SPRINGS, OPS CHECKED GOOD.SDR SIMA20160212003Inverter · inoperativeEMERGENCY EXIT SIGN ABOVE SERVICE DOOR INOPERATIVE. R & R SERVICE DOOR EMER EXIT SIGN INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20160211001Light · inoperativeAFT EMER FLOOR LIGHTING STRIP INOPERATIVE. R & R AFT EMER FLOOR LIGHTING STRIP. OPERATIONS CHECKED GOOD IAW AMM 33-50-12.SDR SIMA20160211002Light · inoperativeROW 3 AISLE EMER LIGHT INOPERATIVE. REPLACED ROW 3 AISLE EMER OVERHEAD LIGHT BULB IAW AMM 33-50-08-000-801-A & 33-50-08-400-801-A.SDR SIMA20160210005Door Sill · corrodedSERVICE DOOR AFT SILL HAS CORROSION. R & R SERVICE DOOR AFT SILL IAW SRM 51-40-02.SDR SIMA20160210006Crossmember · corrodedCENTER AISLE CROSS MEMBER, BETWEEN FRAME 24 & 25 IS CORRODED. R & R CTR AISLE CROSS MEMBER, BETWEEN FRAME 24 & 25 IAW SRM 53-21-10 & ETN EM-53-139 R4.SDR UHLA201602100043Light · misinstalledEMERGENCY LIGHT OVER LT WING IS INSTALLED UPSIDE DOWN. REPOSITIONED LEFT EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA20160210004Fitting · gougedRIGHT AILERON DAMPENER FITTING IS GOUGED. R & R DAMPENER FITTING ON THE RT AILERON IAW EO EM-27MR-112.SDR SIMA20160210001Mount · brokenAFT CABIN FLASHLIGHT MOUNT BROKEN. R & R AFT FLIGHT ATTENDANT FLASHLIGHT BRACKET ASSEMBLY IAW AMM 33-60-01.SDR SIMA20160210002Light · inoperativeNUMBER 2 OVERHEAD EMER LIGHT INOPERATIVE. R & R NR 2 OVERHEAD EMER LIGHT IAW AMM 33-50-08. OPERATIONS CHECKED GOOD.SDR SIMA20160209007Wire · brokenNUMBER 1 EMER LIGHT STRIPS HAS ONE EACH BROKEN WIRE. R & R NR 1 EMER LIGHT STRIPS IAW AMM 33-50-12, OPERATIONS CHECKED GOOD. SEE TASK & WIPS FOR DETAILS.SDR SIMA20160209008Wire Harness · brokenRIGHT FWD EXTERIOR EMER LIGHT WIRE HARNESS IS BROKEN ABOUT A FOOT FROM CONNECTOR P8560. REPAIRED RT FWD INSPECTION LIGHT WIRE HARNESS IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.SDR RAIA201602090001Light · inoperativeMAIN DOOR FLOOD LIGHT INOPERATIVE. R & R MAIN DOOR FLOOD LIGHT. OPS CHECK GOOD.
Back to Embraer EMB-145LR