Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA201603100001Seal · wornBLEED 2 LEAK. R & R BLEED SEALS. OPS AND LEAK CHECK GOOD.SDR ASOA20160310010RLight · malfunctionedTHE OVERHEAD EMERGENCY EXIT LIGHT AT ROW 18 WAS INOPERATIVE. THE SYSTEM WAS RESET AND OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160310002Battery Pack · dischargedNUMBER 2 & 3 EMER LIGHT FLOOR STRIPS INOPERATIVE. R & R THE NR 2 EMER BATTERY PACK & THE POWER SUPPLY IAW AMM 33-50-04-000-801-A & 33-50-04-400-801-A. COMPLIED WITH OPERATIONAL CHECK IAW AMM 33-50-00-700-801-A. OPERATIONS CHECKED GOOD. END BATTERY CHARGER SDR SIMA20160310003Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. REPLACED SERVICE DOOR EMER LIGHT BULB IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A.SDR SIMA20160310005Control Module · faultyCABIN COVE LIGHTS WILL NOT TURN ON. FLIGHT ATTENDANT SMELLED SOMETHING. R & R WITH SERVICEABLE SIDEWALL LIGHT CONTROL MODULE IAW AMM 33 21 01. OPERATIONS CHECKED OK.SDR SIMA20160310004Duct · leakingBLEED 1 LEAK. REFER TO ITEM 2 OF LOG PAGE 3954291. NO DEFECTS NOTED. FOUND CRACKED BLEED LINE IN FWD LT SIDE OF AVIONICS COMPARTMENT. R & R DUCT IAW AMM 36-11-09. PERFORMED APU OPERATIONS CHECK IAW AMM 49-13-00. OPERATIONS CHECKED GOOD. LEAK CHECKED GOOSDR UHLA201602090107Strut · underservicedNLG DID NOT RETRACT, LT LEVER DISAGREE MESSAGE ON EICAS. RETURNED TO FIELD. VERIFIED NLG STRUT SERVICING AND CYCLED LANDING GEAR SEVERAL TIMES WITH NO DEFECTS NOTED.SDR SIMA20160309002Wire · damagedSERVICE DOOR EMER LIGHT IS INOPERATIVE. SEE IPC 33-50-10 FIGURE 40 FOR LOCATION. REPAIRED WIRE W716-0007 IAW SPWM 20-21-00. OPERATIONS CHECKED GOOD.SDR SIMA20160309003Door Sill · corrodedCORROSION ON FWD LOWER BAGGAGE DOOR CUT OUT. INSTALLED NEW CARGO DOOR CUT OUT SILL IAW SRM 51-40-02.SDR SIMA20160309001Power Supply · inoperativeLEFT & RIGHT OVERWING EMER LIGHTS INOPERATIVE. R & R NR 4 EMER LIGHT BATTERY POWER SUPPLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD. BATTERY CHARGER ASSEMBLY PN 11-0049 & SN 11448.SDR RAIA2016030800001Light · shortedLEFT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERATIVE. FOUND LT OVERWING EMERGENCY LIGHT TO BE SHORTED TO GROUND. R & R LT EXTERNAL OVERWING LIGHT ASSY. OPS CHECK GOOD.SDR SIMA20160308001Pitot Line · contaminatedFIRST OFFICERS AIRSPEED INDICATOR UNRELIABLE, APPEARS TO BE BLOCKED, ACTING LIKE ALTIMETER BECAME UNBLOCKED DESCENDING THRU FL 320. DRAINED PITOT STATIC SYS IAW AMM 34-13-00. OPERATIONS CHECKED ADC IAW 34-15-00. OPERATIONS CHECKED GOOD.SDR SIMA20160307001Smoke Warning · false activationBAGG EXTINGUISHER BUTTON ILLUMINATED. BUTTON PRESSED THEN BAGG SMOKE WARNING & BAGG EXTINGUISHER INOPERATIVE EICAS. PERFORMED GVI OF BAGGAGE AREA FOR POSSIBLE DEFECTS, NO DEFECTS NOTED. REF ITEM 2 OF THIS LOG PAGE FOR DISCREPANCY OF BAGGAGE COMPARTMENT FIRESDR Q6HA20160306001Relay · burnedAT 37,000 FT, FLT PILOTS HAD NR 3 PITOT INOPERATIVE CAUTION WITH SMOKE IN THE COCKPIT. FOUND RELAY BURNED.SDR RAIA201603060001Bulb · inoperativePAX DOOR SWING ARM EMERGENCY LIGHT INOPERATIVE LENS CRACKED. REPLACED THE BULB AND REPLACED LENS ON PAX DOOR SWING ARM EMEGENCY. OPS CHECK GOOD.SDR SIMA20160306003Fitting · corrodedDURING MBV INSPECTION, QA FOUND FRAME 68 SHEAR CLIP CORRODED AT LOWER END, BETWEEN STRINGERS 15L & 16L. ACFT WAS REMOVED FROM SERVICE & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIRED IAW SRM 53-31-04 SECTION 4 F. REPAIR MATERIALS, SHEAR CLIP 145SDR SIMA20160306002Bulb · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE. R & R CAPTAIN`S FLASHLIGHT BULB. OPS CHECKED GOOD IAW AMM 33-51-01.SDR ASOA20160306008RCharger · inoperativeDURING MAINTENANCE INSPECTION, THE AFT OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE R & R THE NR 4 BATTERY CHARGER ASSY WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160306001Roller · lack of lubeMAIN CABIN DOOR IS DIFFICULT TO OPEN & CLOSE. SERVICED MAIN DOOR FRAME ROLLERS IAW 53-21-02.SDR ASOA20160305007Inverter · inoperativeDURING MAINTENANCE INSPECTION, THE LT EMERGENCY EXIT DOOR AFT EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE R & R NR 4 INVERTER WITH OPERATIONAL CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR UHLA201603050099Step · bindingMAIN CABIN DOOR HANDLE DIFFICULT TO CLOSE. TOP STEP APPEARS TO BE BINDING ON THE RAILING. ADJUSTED, LUBRICATED TOP STEP. ADJUSTED DUST PLATE LT SIDE, PERFORMED OPS CHECK OF MAIN DOOR AMM 52-10-01.SDR SIMA20160305001Flashlight · inoperativeFIRST OFFICERS FLASHLIGHT SWITCH INOPERATIVE. R & R FIRST OFFICERS FLASHLIGHT AS REQUIRED.SDR SIMA20160304005Wire · brokenNUMBER 1 EMER LIGHT STRIP HAS ONE EACH BROKEN WIRE. R & R NR 1 EMER LIGHT STRIP IAW AMM 33-50-12.SDR ASOA20160304017Light · inoperativeDURING MAINTENANCE INSPECTION THE NR 2 EMERGENCY LIGHT FLOOR STRIP WAS FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE AFFECTED LIGHT STRIP, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20160304004Ecu · failedFLAPS FAILED AT 9* DURING RETRACTION. FLAP FAIL MSG ON EICAS & FLAPS REMAINED AT 9*. PERFORMED CMC DOWNLOAD IAW AMM-45-45-00 & COMPLIED WITH FIM TASK-27-51-00-810-817-A, FLAP RT TRANSMISSION FAIL. R & R FECU IAW-AMM-27-53-02, OPERATIONS CHECKED GOOD.SDR SIMA20160304001Flashlight · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE, WILL NOT HOLD A CHARGE. R & R FLASHLIGHT & ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD. EMER FLASHLIGHT PN P2-07-0011-500.SDR SIMA20160303005Skin · dentedDURING MBV INSPECTION, A DENT WAS FOUND BETWEEN FRAME 7 & 8, BETWEEN STRINGER 13R & 15R. ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIRED DENT IAW ERS-EM-53MR-1954. REPAIR MATERIALS DOUBLER 2024T3SDR SIMA20160303004Frame · gougedDURING MBV INSPECTION, QA FOUND FRAME 70 RT SIDE GOUGED AT PREVIOUS REPAIR. ACFT WAS REMOVED FROM SERVICE & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIRED IAW ERS EM-53MR-1941. REPAIR MATERIALS, EA9394 RESIN, SS301 SHEET 0.016" THICK.SDR SIMA20160303003Skin · dentedDURING MBV INSPECTION, A DENT WAS FOUND, BETWEEN FRAME 7 & 8, BETWEEN STRINGERS 13R & 15R. ACFT WAS REMOVED FROM SERVICE & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIRED DENT IAW ERS-EM-53MR-1954. REPAIR MATERIALS, DOUBLER 2024T3 0.040", & FILLESDR SIMA20160303002Light · inoperativeRIGHT AFT OVERWING EMER LIGHT INOPERATIVE. R & R THE RT AFT OVERWING EMER LIGHT LAMP IAW AMM 33-50-07-000-801-A & 33-50-07-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20160303001Light · inoperativeMAIN DOOR EXTERIOR EMER LIGHT INOPERATIVE. R & R MAIN DOOR EMER LIGHT LAMP IAW AMM 33-50-06-000-801-A & 33-50-06-400-801-A. OPERATIONS CHECKED GOOD.SDR RAIA201603020001Unknown · odorLAV SMOKE INDICATION PILOT INSPECTED SAID THERE WAS A HAZE IN THE LAV WITH A SWEET ODOR. PERFORMED ENGINE GROUND RUNS. NO DEFECTS NOTED. PERFORMED INSPECTION OF LAV LIGHTS AND TOILET SYSTEMS, NO DEFECTS NOTED.SDR RAIA201603010005Windshield · odorSTRONG ELECTRICAL BURNING ODOR IN COCKPIT. R & R F/O'S WINDSHEILD. OPS AND LEAK CHECK GOOD.SDR RAIA201603010004Controller · failedSMOKE IN COCKPIT COMING FROM BELOW FO WINDOW TURNED OFF WINDOW HEAT AND SMOKE WENT AWAY. R & R WINDSHEILED TEMP CONTROLLER. OPS CHECK GOOD. NO DEFECTS NOTED.SDR RAIA201603010002Thermostat · failedBLEED 2 OVERTEMP IN ICING ON CLIMBOUT. RETURNED TO DEPARTING AIRPORT. REPLACED FAN AIR VALVE CONTROL THERMOSTAT. OPS CHECK GOOD.SDR SIMA20160301005Skin · crackedFRAME 75, STRINGER 1R - 3R, UPPER AREA FASTENER HAS CRACKS. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1959.SDR SIMA20160301006Skin · crackedFRAME 75, STRINGER 1L - 3L, UPPER AREA SKIN HAS CRACKS. PERFORMED PERMANENT REPAIR OF UPPER SKIN AT FRAME 75, STRINGER 1L - 3L, IAW ERS-EM-53MR-195.SDR SIMA20160301002Contactor · defectiveAT GATE PRIOR TO DEPARTURE, PUNGENT ACRID ODOR, SUGGESTIVE OF ELEC FIRE FILLED FLIGHT DECK. APU RUNNING, NO GND POWER, INSPECTED ACFT THERMALLY, NO SIGNIFICANT HOT SPOTS DETECTED INTERNAL OR EXTERNAL. SEE PRIOR WRITE UP FOR SMOKE PG 3998956 1. REF AML PAGE SDR SIMA20160301001Reinforcement · crackedREINFORCEMENT FRAME ABOVE LT WINDSHIELD LATERAL POST CRACKED, PERMANENT REPAIR. R & R REINFORCEMENT ABOVE LATERAL POST IAW ERS-EM-53MR-203.SDR RAIA201602290003Coupling · wornBLEED 2 LEAK EICAS MESSAGE IN FLIGHT. FOUND NR 2 ENGINE BLEED VALVE OUTLET COUPLING BAD, R & R BLEED COUPLING. OPS CHECK GOOD. INSPECTED BLEED DUCTS NO LEAKS NOTED.SDR RAIA201602290002Feeder Cable · odorBURNING ODOR NOTICED IN FLIGHT DECK DURING FLIGHT, NO VISIBLE SMOKE ONLY ODOR. R & R F/O'S WINDSHIELD HEAT POSITIVE CABLE IAW AMM 20-00-03 AND PERFORMED OPS CHECK OF F/O'S WINDSHIELD HEAT IAW AMM 30-42-00. OPS NORMAL AT THIS TIME.SDR HNAA2016022900066Warning Message · false activationCLOSE EICAS MESSAGE DISPLAYED E2 NO DISPLAY. INSPECTED ACFT FOR CODES ON IAW AMM 45-45-00. NO CODES FOUND. POWERED ACFT DOWN & UP. EICAS MESSAGE CLEARED. ACFT OK. FOR SERVICE.SDR UHLA201602260085Mechanism · contaminatedMAIN CABIN DOOR WOULD NOT OPEN FROM INSIDE OR OUTSIDE THE ACFT. INSPECTED AND FOUND DEBRIS ON ACTUATING AND LOCKING MECHANISM. REMOVED DEBRIS, OPS CHECKS GOOD. PERFORMED 52-11-00 AND 25-23-04.SDR UHLA201602260084Stop · damagedAIR STAIRS DO NOT DEPLOY. R & R MAIN DOOR STEP FOLD-OUT BACKSTOP IAW AMM 52-13-02. OPS CHECKED GOOD.SDR SIMA20160226009Switch · malfunctionedDURING CLIMB OUT, BLD 1 VLV CLSD ADVISORY MSG ON EICAS. UNABLE TO OPEN BLD VLV OUT TO ORD UPON REDUCING THRUST LEVERS, MSG EXTINGUISHED. R & R NR 1 BLEED PUSH BUTTON SWITCH IAW MM 20-13-04. OPERATIONS CHECKED GOOD.SDR SIMA20160226005Skin · corrodedSKIN CORROSION FRAME 65 - 66, BETWEEN STRINGER 21L - 21R. ACCOMPLISHED PERMANENT REPAIR IAW ERS-EM-53MR-1944.SDR SIMA20160226006Wire · damagedLEFT NR 1 EMER LIGHT STRIP WIRES PULLED OFF. R & R LT NR 1 FLOOR EMER LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226007Wire · brokenLEFT 66 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE AT BASE OF LIGHT. R & R NR 6 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226008Wire · brokenLEFT NR 5 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE AT BASE OF LIGHT. R & R NR 5 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226004Skin · corrodedCORROSION ON SKIN, FRAME 67, BETWEEN STRINGER 21L - 21R. ACCOMPLISHED PERMANENT REPAIR IAW ERS-EM-53MR-1945.
Back to Embraer EMB-145LR