Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20151123005Crossbeam · corrodedGALLEY FLOOR CROSSBEAM CORRODED AT FRAME 20. R & R CORRODED CROSSBEAM GALLEY FLOOR AT FRAME 20 IAW SRM 51-40-02 & ETN-EM-53-139.Nov 23, 2015 · N691AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20151123004Duct · detachedBLEED 1 LEAK CLIMBING THROUGH 3000 FEET. LANDED UNDER WT 43000 LBS. TRANSFERRED TO NRWC 695-MIA-02360. DOWNLOADED CMC IAW-AMM-45-45-00 & NO FADEC OVERTEMP FOUND. RE-CONNECTED LT RAM AIR DUCT IAW-AMM-21-25-01. PERFORMED BLEED SYS 1 & 2 OPERATIONAL CHECK ATNov 23, 2015 · N695AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20151123001Pump · failedE1 HYD PUMP FAIL AT 32000 FT, WENT AWAY AT 3000 FT & GEAR EXTENSION. R & R NR 1 HYD PUMP IAW MM 29-10-03. OPERATIONS CHECK LEAK, CHECKED OK.Nov 23, 2015 · N660CL · Emb EMB145LR · Hydraulic Pump (Electric/Engine), MainSDR SIMA20151122002Control Panel · faultyLAVATORY SMOKE PRESENTED ON EICAS. R & R SMOKE DETECTOR PANEL IAW 26-14-02. OPERATIONS CHECKED GOOD.Nov 22, 2015 · N636AE · Emb EMB145LR · Smoke DetectionSDR SIMA20151121010Rib · crackedRIGHT WING RIB 5 CRACKED ON AFT LARGE LIGHTNING HOLE AT 7 O'CLOCK POSITION. ACCOMPLISHED REPAIR OF RT WING RIB 5 IAW ERS-EM-57MR-551.Nov 21, 2015 · N625AE · Emb EMB145LR · Wing, Rib/BulkheadSDR RAIA201511210001Connector · dirtyEMERGENCY EXIT LIGHT ON PASSENGER DOOR IS INOPERATIVE. MAINTENANCE CLEANED CONNECTORS AND RELAMPED, OPS CHECKED GOOD.Nov 21, 2015 · N839HK · Emb EMB145LR · Light System WiringSDR SIMA20151121006Door Frame · corrodedSERVICE DOOR CUT OUT AFT FRAME HAS AREA OF CORR0SION ABOVE THE FLOOR LINE. REPAIRED THE SERVICE DOOR CUT OUT AFT FRAME, ABOVE THE FLOOR LINE IAW SRM 53-00-04, 51-40-02.Nov 21, 2015 · N625AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20151121005Skin Panel · damagedHAIL DAMAGE EVENT. REPLACE CTR FUSELAGE I RT SKIN PANEL. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. R & R CTR FUSELAGE I RT SKIN PANEL IAW SRM 53-21-01 SI, 51-20-01, 51-20-03, 51-40-06, 51-40-02,Nov 21, 2015 · N674RJ · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151121002Inverter · inoperativeFLOOR PROX LIGHTS 6, 7 & 8 INOPERATIVE. R & R NR 6 INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.Nov 21, 2015 · N902BC · Emb EMB145LR · Emergency LightingSDR SIMA20151121001Light · inoperativeFLOOR PROX LIGHT 1 INOPERATIVE. R & R FLOOR PROX LIGHT 1 STRIP IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.Nov 21, 2015 · N902BC · Emb EMB145LR · Emergency LightingSDR SIMA20151121003Light · inoperativeMAIN DOOR EMER LIGHT INOPERATIVE. RELAMPED MAIN DOOR EXTERNAL EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Nov 21, 2015 · N650AE · Emb EMB145LR · Emergency LightingSDR SIMA20151120007Doubler · gougedFRAME 65 REPAIR DOUBLER, BETWEEN STRINGER 12R & 13R IS GOUGED. FOUND DURING OPEN UP. ACCOMPLISHED REPAIR TO FRAME 65 REPAIR DOUBLER IAW ERS-EM-53MR-1789.Nov 20, 2015 · N625AE · Emb EMB145LR · Fuselage Main, FrameSDR UHLA201511200818Door · stuckDURING INSPECTION, THE RT EMERGENCY EXIT WINDOW WAS FOUND TO BE STUCK. MAINTENANCE REPOSITIONED THE SIDEWALL LINER AND RE-INSTALLED THE EMERGENCY EXIT IAW AMM 25-12-09. ALL OPS CHECKS WERE GOOD AND NO FURTHER DEFECTS HAVE BEEN NOTED.Nov 20, 2015 · N569RP · Emb EMB145LR · Emergency ExitsSDR SIMA20151120006Frame · corrodedL SHAPE AT FRAME 65, BETWEEN STRINGER 16L - 17L CORRODED. INSTALLED SERVICEABLE REPAIR SECTION IAW SRM 51-40-02 & 53-31-04.Nov 20, 2015 · N625AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20151120003Battery · dischargedEMERGENCY LIGHTS ON CABIN CEILING PANELS 253CLC & 263ALC ARE INOPERATIVE. R & R NR 4 EMER BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED OK. BATTERY CHARGER ASSEMBLY PN 11-0049.Nov 20, 2015 · N694AE · Emb EMB145LR · Emergency LightingSDR SIMA20151120004Wire · damagedLEFT NR 2 EMER LIGHT STRIP WIRES PULLED OFF. R & R LT NR 2 FLOOR EMER LIGHT STRIP IAW AMM 33-50-12.Nov 20, 2015 · N694AE · Emb EMB145LR · Light System WiringSDR SIMA20151120001Skin · crackedRIGHT REAR FUSELAGE I SKIN CRACKS AT FRAME 75 ABOVE STRINGER 2R. PERFORMED PERMANENT REPAIR OF RT REAR FUSELAGE I SKIN AT FRAME 75 ABOVE STRINGER 2R IAW ERS-EM-53MR-1791.Nov 20, 2015 · N694AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151120005Skin · crackedLEFT REAR FUSELAGE I SKIN CRACKS AT FRAME 75 ABOVE STRINGER 2L. PERFORMED PERMANENT REPAIR OF LT REAR FUSELAGE I SKIN AT FRAME 75 ABOVE STRINGER 2L IAW ERS-EM-53MR-1790.Nov 20, 2015 · N694AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151120002Skin · crackedRUDDER II LOWER RT SIDE, SKIN CRACKED. PERFORMED DOUBLER REPAIR ON RT RUDDER II IAW ERS-EM-55MR-380.Nov 20, 2015 · N694AE · Emb EMB145LR · Rudder, Plate/SkinSDR RAIA201511200001Bulb · inoperativeENTRANCE EMERGENCY CEILING FLOOD LIGHT NR 13 INOPERATIVE. R & R BULB IN ENTRANCE EMERGENCY FLOOD LIGHT NR 13. OPS CHECK GOOD.Nov 20, 2015 · N619AE · Emb EMB145LR · Emergency LightingSDR ASOA20151120194Bracket · corrodedDURING C-CHECK, FOUND CARGO DOOR LOWER ANGLE BRACKET IS CORRODED AROUND NUTPLATE HOLES. INSTALLED NEW CARGO DOOR LOWER ANGLE BRACKET IAW SRM 51-40-02. APPROVED FOR RETURN TO SERVICE.Nov 20, 2015 · N15555 · Emb EMB145LR · Fuselage Main, Attach FittingsSDR SIMA20151119005Skin · damagedHAIL DAMAGE EVENT. R & R RT CTR FUSELAGE I UPPER SKIN IAW SRM 51-40-02, 53-21-01-SI, 51-20-01, 51-20-03, 51-40-06, ETN-EM-51-118 & ETN-EM-53-262.Nov 19, 2015 · N648AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151119004Brake · overheatedAFTER LANDING & PARKED AT THE RAMP, WE HAD AN INDICATION OF BRAKE OVERHEAT ON THE EICAS. ALSO THE MFD INDICATION OF THE LT OTBD & INBD WENT TO THE TOP OF THE YELLOW ARC. THE RAMP PERSONNEL REPORTED SMOKE COMING FROM THE LT MAIN GEAR. AFTER THE POST FLIGHT SNov 19, 2015 · N642AE · Emb EMB145LR · BrakeSDR SIMA20151119003Sensor · faultyFLAP FAIL ON APPROACH, FLAPS AT ZERO DEGREES. TRANSFERRED TO NRWC 647-ORD-02283. R & R FLAP VELOCITY SENSOR IAW AMM 27-51-12. REFER TO NRWC 647-ORD-02283. R & R FLAP TRANSMISSION BRAKE IAW AMM 27-51-01. ACCOMPLISHED OPERATIONS CHECK IAW AMM 27-51-00. OPENov 19, 2015 · N647AE · Emb EMB145LR · Trailing Flap Position Indicating SystemSDR SIMA20151119002Skin · damagedHAIL DAMAGE EVENT. REPLACE LT CTR FUSELAGE 1 SKIN. R & R LT CTR FUSELAGE I UPPER SKIN IAW SRM 51-40-02, 53-21-01-SI, 51-20-01, 51-20-03, 51-40-06, ETN-EM-51-118, ETN-EM-53-262 & ERS EM-5300-1759.Nov 19, 2015 · N632AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151119001Skin · damagedHAIL DAMAGE EVENT. REPLACE LT ELEVATOR UPPER CTR SKIN. R & R SKIN IAW SRM 51-20-01, 51-40-02, 51-20-03, 51-40-06, 55-20-01, ETN-EM-55-073R2 & ETN-EM-55-076.Nov 19, 2015 · N632AE · Emb EMB145LR · Elevator, Plate/SkinSDR SIMA20151118006Structure · corrodedTHE LAVATORY BUCKET IS CORRODED. INSTALLED REPAIR DOUBLER & NUTPLATES IAW SRM 51-40-02 & SRM 51-40-09. SEE WIPS & TASKS FOR DETAILS.Nov 18, 2015 · N625AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR ASOA20151118067Battery · inoperativeDURING ROUTINE MAINTENANCE, THE EMERGENCY EXIT ROW EMERGENCY LIGHTS AT OVERWING DOORS WOULD NOT ILLUMINATE. MAINTENANCE REPLACED THE NR 3 EMERGENCY LIGHT BATTERY. OPS CHECKS WERE GOOD.Nov 18, 2015 · N14517 · Emb EMB145LR · Emergency LightingSDR SIMA20151118003Flashlight · unsecureCAPTAINS FLASHLIGHT DOES NOT STAY SECURED IN HOLDER. CAPTAIN FLASHLIGHT DEFERRED, M PROCEDURES COMPLIED WITH. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD MEL ITEM RESTORED.Nov 18, 2015 · N653AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151118002Inverter · inoperativeDURING PS1 CHECK, FOUND FWD OVERWING EMER EXIT SIGN LIGHT INOPERATIVE. R & R EMER LIGHT DC & AC INVERTER NR 6 IAW AMM 33-50-11.Nov 18, 2015 · N608LM · Emb EMB145LR · Emergency LightingSDR SIMA20151117003Door · dentedMAIN PAX DOOR HAS A DENT, LOCATED 16" AFT OF DOOR FWD EDGE & 13.5" UP FROM LOWER EDGE. DENT IS 1" L X 1.75" W X .012" D. ACCOMPLISHED PERMANENT REPAIR TO MAIN PAX DOOR DENT IAW ERS-EM-5200-468. DENT ENTERED INTO ADL 6960035.Nov 17, 2015 · N696AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20151117001Tape · meltedDURING CRUISE & DESCENT A BURNING SMELL WAS NOTICED & THEN WENT AWAY. POST FLIGHT INSPECTION REVEALED SPEED TAPE MELTED AWAY FROM ACM AREA. TRANSFERRED TO NRWC 617-DFW-02434. COMPLIED WITH ETN-EM-72-034 IAW NRWC 617-DFW-02437, NO ODOR NOTED. REPLACED LIGHTNov 17, 2015 · N617AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20151116003Wire · brokenAFT EXIT SIGN AT 252CRW HAS BROKEN WIRE, ACFT SIDE. INSTALLED CONNECTOR ON WIRE W192-8743-22, ACFT SIDE, AT SP9104 IAW SWPM 20-50-00.Nov 16, 2015 · N694AE · Emb EMB145LR · Light System WiringSDR SIMA20151116004Skin Panel · damagedHAIL DAMAGE EVENT. REPLACE FWD FUSELAGE II RT SKIN PANEL. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. R & R FWD FUSELAGE II RT SKIN PANEL IAW SRM 53-12-01 SI, 51-20-01, 51-20-03, 51-40-06, 51-40-0Nov 16, 2015 · N674RJ · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151115001Engine · shutdownNR 1 ENGINE SHUTDOWN DURING CLIMB OUT BELOW 2000 FT. R & R LT ENGINE IAW WC 71-000-00. GROUND RAN ACFT. OPS CHECKED GOOD, NO DEFECTS NOTED.Nov 15, 2015 · N652RS · Emb EMB145LR · Engine (Turbine/Turboprop)SDR SIMA20151115003Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EMER LIGHT LAMP IAW AMM 33-50-09. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.Nov 15, 2015 · N697AB · Emb EMB145LR · Emergency LightingSDR SIMA20151115004Flashlight · inoperativeREAR CABIN FLASHLIGHT INOPERATIVE. R & R REAR CABIN FLASHLIGHT IAW AMM SMP. OPERATIONS CHECKED GOOD.Nov 15, 2015 · N656AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151115002Skin · damagedPASSENGER DOOR SKIN 3" SCRATCH & TWO SMALL GOUGES. REQUIRE REINSPECT IAW ERS-EM-52DF-463 PT B. ACCOMPLISHED PERMANENT REPAIR TO PAX DOOR SKIN IAW ERS-EM-52DF-463 PT D.Nov 15, 2015 · N642AE · Emb EMB145LR · Passenger/Crew DoorsSDR ASOA20151115193Beam · corrodedDURING C-CHECK, THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE BEAM IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Nov 15, 2015 · N22909 · Emb EMB145LR · Fuselage Main, StructureSDR ASOA20151115192VSkin · crackedDURING C-CHECK, THE LT AFT SKIN WAS FOUND TO BE CRACKED AROUND A RIVET AT FRAME 76, STRINGER 6L. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW EC5330-03071. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Nov 15, 2015 · N22909 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151114006Skin Panel · damagedHAIL DAMAGE EVENT. REPLACE REAR FUSELAGE I TOP SKIN PANEL. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. R & R REAR FUSELAGE I TOP SKIN PANEL IAW SRM 53-22-01 SI, 51-20-01, 51-20-03, 51-40-06, 51-40Nov 14, 2015 · N674RJ · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151114001Sensor · failedBRAKE OVERHEAT ON EICAS AFTER TAKEOFF, RT INBD INDICATOR IN AMBER, COMPLIED WITH AOM VOL 1. PROCEDURES RETURNED, NOT AN OVERWEIGHT LANDING SINK RATE 300FT PER MIN. DEFERRED RT INBD BRAKE INDICATION. R & R BRAKE TEMP SENSOR IAW AMM 32-47-01. OPERATIONS CHECNov 14, 2015 · N925AE · Emb EMB145LR · Landing Gear Brake SystemSDR SIMA20151114004Cradle · crackedFOWARD CABIN FLASHLIGHT CRADLE IS CRACKED. R & R FWD FLIGHT ATTENDANT FLASHLIGHT HOLDER. OPERATIONS CHECKED GOOD IAW 33-50-06 AMM.Nov 14, 2015 · N923AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151114003Flashlight · inoperativeAFT FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. PERFORMED AFT FLIGHT ATTENDANT FLASHLIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-50-00, COULD NOT DUPLICATE FAULT.Nov 14, 2015 · N688AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151114005Mount Bracket · brokenREAR CABIN FLASHLIGHT MOUNTING BRACKET BROKEN. R & R REAR CABIN FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.Nov 14, 2015 · N641AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151113007Door · dentedLOG PAGE 3952767 ITEM 1 TDMI 935T5229, MAIN PAX DOOR HAS A DENT & GOUGE AT LOWER RT CORNER REPAIR IAW ERS-EM-52DF-456. COMPLIED WITH PERMANENT REPAIR IAW ERS-EM-52DF-456 PART C. TDMI RESTORED.Nov 13, 2015 · N935AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20151113005Cradle · brokenFIRST OFFICERS FLASHLIGHT CHARGING CRADLE IS BROKEN, WILL NOT HOLD FLASHLIGHT IN PLACE. REPLACED FLASHLIGHT ASSEMBLY IAW 33-50-16.Nov 13, 2015 · N686AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151113008Light · inoperativeLEFT OVERWING EMER LIGHT INOPERATIVE. R & R LT OVERWING EMER LIGHT BULB, OPERATIONS CHECKED GOOD IAW AMM 33-50-10.Nov 13, 2015 · N658AE · Emb EMB145LR · Emergency LightingSDR SIMA20151113006Actuator · failedFLAPS FAIL ON APPROACH, FAILED AT 0. RESET FLAP SYS & OPERATIONS CHECK IAW AMM 27-51-00. OPERATIONS CHECKED GOOD, NO MSGS NOTED. WHILE TROUBLESHOOTING FLAP RT TRANSMISSION FAIL CMC MSG. FOUND RT NR 3 FLAP ACTUATOR, RT OTBD FLAP LT SIDE, LEAKING & RESERVOIRNov 13, 2015 · N647AE · Emb EMB145LR · Trailing Flap Position Indicating SystemSDR SIMA20151113004Skin · dentedLEFT LE NR 1, 511 IS DENTED 54" FROM THE INBD EDGE. COMPLETED REPAIR IAW ERS-EM-57MR-547.Nov 13, 2015 · N695AE · Emb EMB145LR · Wing, Plate/Skin
Back to Embraer EMB-145LR