Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20150322005Bracket · crackedLEFT BRACKET WHICH CONNECTS THE OMEGA BEAM TO THE PRESS DECK IS CRACKED AT RT OMEGA BEAM BETWEEN FRAMES 47 - 48. INSTALLED NEW L BRACKET IAW SRM 53-23-02. SHEAR CLIP PN 140-04213-609.SDR SIMA20150322006Stiffener · crackedLOWER STIFFENER IS CRACKED AT LT FLOORBEAM BETWEEN FRAMES 16 - 17. R & R LOWER STIFFENER AT LT FLOORBEAM BETWEEN FRAMES 16 - 17 IAW SRM 51-40-02.SDR SIMA20150322008Attach Angle · crackedLEFT UPPER WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE NR 3 IS CRACKED 3/8" ON THE FWD & AFT ENDS, JUST FWD OF FRAME 48. R & R LT UPPER WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE NR 3, JUST FWD OF FRAME 48, IAW SRM 51-40-02 & ETN-EM-53-142.SDR SIMA20150322003Bracket · brokenREAR FLASHLIGHT CRADLE BROKEN. DEFERRED IAW MEL 25-53. M PROCEDURES COMPLIED WITH. R & R AFT EMER FLASHLIGHT BRACKET IAW AMM 33-50-16. OPERATIONAL CHECK GOOD, MEL RESTORED.SDR SIMA20150322001Wire · damagedTHERE WAS A FLASH & POP WITH BURNING SMELL UNDER CAPTAINS PEDESTAL. CB C 20 POPPED, LOSS OF ALL ASSOCIATED ELEC. PERFORMED WIRE REPAIR ON WIRE W101-3438-24, AT MFD-1 PEDESTAL LIGHTING PANEL, WIRE W101-0837 20, PEDESTAL CONT LT, PEDESTAL LIGHTING PANEL & W101SDR SIMA20150322002Skin · corrodedFUSELAGE SKIN CORRODED UNDER COCKPIT FLOOR BETWEEN FRAMES 13 & 14 BETWEEN STRINGERS 20R & 19R. REPAIRED IAW ERS-EM-53MR-1160 & ERS-EM-53MR-1163.SDR SIMA20150321008Doubler · crackedDURING IMBV INSPECTION, QC FOUND THE COCKPIT UNDERFLOOR ACCESS HATCH 123BL PREVIOUS REPAIR DOUBLER CRACKED UNDER THE HINGE PIN BRACKET. ACFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. PERFORMED A PERMANESDR SIMA20150321009Profile · corrodedDURING IMBV INSPECTION, QC FOUND THE SERVICE DOOR LOWER & REAR PROFILES HAVE NUTPLATE HOLES CORRODED. ACFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. BLENDED OUT AFFECTED AREAS ON SERVICE DOOR LOWER & RESDR SIMA20150321007Battery · dischargedFUSELAGE EMER LIGHT FWD OF RT WING DIM. R & R NR 2 EMER BATTERY ASSEMBLY & CHARGER IAW AMM 33-50-04. BATTERY CHARGER ASSEMBLY PN 11-0049, SN 13314.SDR SIMA20150321006Holder · brokenFMR 612250A09 CREW MEMBER FLASHLIGHTS & HOLDERS. LT COCKPIT FLASHLIGHT HOLDER BROKEN CP 156679. RESTORATION OF MEL ITEMS. REVIEW THE MEL & ENSURE APPROPRIATE MX ACTIONS ARE TAKEN TO RESTORE THE ITEM & SYS. CONDITIONS & LIMITATIONS THAT WERE REQUIRED BY THESDR SIMA20150321005Mechanism · lack of lubeFLIGHT ATTENDANT REPORTS DOOR IS HARD TO CLOSE & OPEN HANDLE IS LOOSE AT MAIN CABIN DOOR. INSPECTED & LUBRICATED ACTUATING & LOCKING MECHANISM IAW AMM 52-11-00. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20150321001Uplock · defectiveUPON RAISING GEAR AFTER TAKEOFF UNUSUAL NOISE, THUNK, THUNK, THUNK ETC & LT GEAR INDICATOR CYCLED BETWEEN UP & IN TRANSIT. TRANSFERRED TO NRWC 609-DFW-02208. R & R LT MLG UPLOCK BOX IAW AMM 32-33-10. OPERATIONS CHECKED GOOD. PROXIMITY SENSOR PN 8-527-01, SSDR SIMA20150321002Connector · defectiveUPON RAISING GEAR AFTER TAKEOFF UNUSUAL NOISE, THUNK, THUNK, THUNK ETC, & LT GEAR INDICATOR CYCLED BETWEEN UP & TRANSIT. R & R LT MLG FWD DOWNLOCK PROXIMITY SWITCH & CONNECTOR IAW AMM 36-61-02 & WM 20-50-00. OPERATIONS CHECKED GOOD AT THIS TIME. IPC PN VERISDR SIMA20150321004Unknown · odorOPERATIONS REPORTED TO MOC, ELEC BURNING SMELL IN THE GALLEY. NOTE, ACFT ONLY ON GND POWER. ACFT CONFIGURED THE SAME AS WHEN OPERATIONS NOTICED SMELL & ODOR. INVESTIGATED GALLEY & SURROUNDING AREA FOR ODOR, NO EVIDENCE OF COMPONENTS EMANATING BURNING SMELLSDR UHLA2015032000236Threshold · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE SERVICE DOOR THRESHOLD. THE THRESHOLD WAS REPAIRED IAW SRM 53-21-02.SDR UHLA2015032000235Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LT OMEGA BEAM BETWEEN FRAME 24 AND 25. THE BEAM WAS REPAIRED IAW SRM 53-00-10.SDR UHLA2015032600234Tee Fitting · corrodedDURING INSPECTION, THE FRAME 65 TEE FITTING WAS FOUND TO BE CORRODED. THE FITTING WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000233Door Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE "L" SHAPE FRAME 65 CARGO DOOR STOP. THE "L" SHAPE FRAME 65 DOOR STOP WAS REPLACED IAW SRM 53-31-04.SDR UHLA2015032000232Support · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE NLG UPLOCK SUPPORT. THE SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000231Threshold · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR THRESHOLD BETWEEN FRAME 65 AND FRAME 68. THE THRESHOLD WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000230Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RT OMEGA BEAM BETWEEN FRAMES 24 AND 25. THE BEAM WAS REPLACED IAW SRM 53-00-10.SDR UHLA2015032000229Support · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE RT INBD BEAM SUPPORT BETWEEN FRAME 47 AND 48. THE BEAM WAS REPLACED IAW SRM 53-23-02.SDR UHLA2015032000228Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 26 AND STRINGERS 15R AND 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000227Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 24 BETWEEN STRINGERS 15L AND 16L. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000226Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CENTER OMEGA BEAM AT FRAME 20. THE BEAM WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000225Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 25 BETWEEN STRINGERS 15R AND 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015032000224Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 24 AND STRINGERS 16R AND 17R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR SIMA20150320002Splice · damagedHAIL DAMAGE EVENT. CFI LT UPPER BUTT SPLICE AT FRAME 16, STRINGER 1L-1R GOUGED. PERFORMED REPAIR IAW ERS-EM-53MR-1174.SDR SIMA20150320001Apu · malfunctionedON TAXI OUT SMOKE IN COCKPIT & CABIN FOLLOWED BY APU FAIL CAUTION ON EICAS. INSPECTED & COMPLIED WITH ETN-EM-72-034. FOUND APU TO BE SOURCE FOR THE SMELL. DEFERRED APU IAW MEL 49-1. R & R APU REF WC 49-800-05. OPERATIONS CHECKED GOOD AT THIS TIME & MEL RESDR RAIA201503200001Proximity Switch · inoperativeUNABLE TO MOVE LANDING GEAR LEVER IN THE UP POSITION AFTER T/O, LANDING GEAR AIR/GROUND FAIL MSG, RETURNED TO BLOCK. MAINTENANCE REPLACED NOSE WOW SWITCH, PERFORMED GEAR SWINGS, OPS CHECK GOOD.SDR SIMA20150319004Door · scratchedPASSENGER DOOR SCRATCHED & GOUGED ON LOWER TE. TRANSFERRED TO AML PAGE 3740390 ITEM 1. SATISFACTORILY ACCOMPLISHED ERS-EM-52MR-308.SDR SIMA20150319002Flashlight · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16.SDR ASOA20150319074VYoke · crackedDURING C-CK. ENGINE NR 1 FWD LOWER YOKE FITTING CRACKED. R & R 31 ENGINE FWD LOWER MOUNT FITTING IAW EC5450-01138. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20150318001Light · inoperativeEXTERIOR EMER LIGHT INOPERATIVE, RT SIDE FWD OF WING. R & R EXTERIOR EMER LIGHT LAMP RT FWD OF WING IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR ASOA20150318073Beam · corrodedDURING C-CK. CARGO DOOR LOWER BEAM CORRODED BETWEEN FRAME 65-68. R & R CARGO DOOR LOWER BEAM IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150318072Stringer · corrodedDURING C-CK, STR 21R CORRODED BETWEEN FR 10-11. R & R STRINGER IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150327010Battery · inoperativeBOTH OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 BATTERY CHASSIS ASSEMBLY TRAY. OPS CHECK GOOD ACFT RELEASED AND RETURNED TO SERVICE.SDR SIMA20150317009Skin · damagedREAR FUSELAGE 1 LOWER SKIN DENT & CREASE. FABRICATED & INSTALLED FILLER & DOUBLER IAW ERS-53MR-1123.SDR SIMA20150317008Fitting · crackedRIGHT AILERON OTBD LUG FITTING CRACKED & BENT. REQUIRES NEW FITTING & HAT BUSHING. REPLACED PCA FITTING IAW EO EM-27MR-112.SDR SIMA20150317007Stringer · corrodedSTRINGER 18R PROFILE AT FRAME 13 IS CORRODED BEYOND LIMITS. R & R STRINGER 18R AT FRAME 13 IAW SRM 51-40-02.SDR SIMA20150317006Thermostat · faultyBLEED 2 OVER TEMP DURING CLIMB THRU 10000 FT IN ICING CONDITIONS, REF FIM 36-11-00-810-804. PERFORMED INSPECTION GVI OF PRE COOLER REGION IAW AMM 36-11-04. CLEANED FAN AIR VLV FILTER AMM 36-11-03. R & R FAN AIR THERMOSTAT IAW AMM 36-11-06. OPERATIONS CHECSDR SIMA20150317005Light · inoperativeSEAT 12A OVERWING EMER LIGHT INOPERATIVE. R & R OVERWING EMER LIGHT LAMP AT SEAT 12A IAW AMM 33-50-07-000-801-A & 33-50-07-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150317003Flashlight · crackedFLIGHT ATTENDANTS FLASHLIGHT HAS CRACKED OUTER RING & CHARGER LIGHT MISSING. R & R IAW AMM 33-50-16.SDR SIMA20150317004Connector · broken5TH FLOOR PROXIMITY LIGHT CONNECTOR BROKEN. REPAIRED CONNECTOR ON 5TH FLOOR PROXIMITY EMER LIGHT IAW SWPM 20-21-00 & AMM 33-50-00. OPERATIONAL CHECKED GOOD.SDR SIMA20150317002Sign · inoperativeCABIN FWD EMER EXIT SIGN INOPERATIVE. R & R CABIN FWD EMER EXIT SIGN IAW AMM 33-50-14. OPERATIONS CHECKED GOOD.SDR SIMA20150316012Structure · corrodedCARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES ARE CORRODED. REMOVED CORROSION FROM CARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES & FOUND TO BE ACCEPTED AS IS IAW ERS-EM-52MR-312. SEE TURNOVER FOR DETAILS.SDR SIMA20150316011Doubler · corrodedRIGHT OMEGA BEAM PREVIOUS REPAIR DOUBLER UNDER LAVATORY GUSSET CORRODED AT NUTPLATE HOLE. REPAIRED RT OMEGA BEAM PREVIOUS REPAIR DOUBLER IAW ERS-EM-53MR-1164.SDR SIMA20150316002Pin · malfunctionedDURING CLIMB, CREW HEARD A SQUEAL & NOTED THE PIN ON THE DV WINDOW MOVE FROM FLUSH TO THE PROTRUDING POSITION. RETURNED WITHOUT INCIDENT. OPS TESTED THE DV WINDOW IAW AMM 56-11-01. TESTED SATISFACTORILY.SDR SIMA20150316006Unknown · odorAFTER NR 1 ENG STARTED WITH APU ON TAXI TO RUNWAY WE SMELLED A STRONG BURNING SMELL. STARTED NR 2, IT WENT AWAY, SLIGHTLY CAME BACK WITH SAME BURNING SMELL. TROUBLE SHOT ODOR TO NR 1 PACK, DEFERRED 31 PACK, ACM MEL 21-27. COMPLIED WITH ETN-EM-72-034. TROUBSDR SIMA20150316004Flashlight · inoperativeFLIGHT OFFICERS EMER FLASHLIGHT INOPERATIVE. R & R FLIGHT OFFICERS EMER FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.
Back to Embraer EMB-145LR