SDR SIMA20141002007Unknown · failedTAKEOFF ABORTED AT 70 - 80 KNOTS DUE TO MASTER WARNING & MASTER CAUTION & SPS ADVANCED GPWS INOPERATIVE SPS 1 & 2. STALL PROTECTION SYS OPERATIONS GOOD IAW AMM 145 27-36-00. SEE THIS LOG PAGE ITEMS 2 & 3. EGPWS WIND SHEAR WARNING & FLIGHT GUIDANCE SYS, WIOct 2, 2014 · N671AE · Emb EMB145LR · Dependent Position Determining SystemSDR RAIA201410020002Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN DURING POST FLIGHT. MAINTENANCE INSPECTED AND LUBED, ADJUSTED DOOR, OPS CHECKED GOOD.Oct 2, 2014 · N832HK · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20141002004Ballast · odorSTRONG ELEC SMOKE SMELL IN COCKPIT. FLIGHT ATTENDANT STATED STRONG ELEC SMOKE SMELL COMING FROM GALLEY AREA. DECLARED EMER WITH ATC, EMER EVAC ON RUNWAY. PERFORMED FIM TASKS 72--00-00. OPERATIONS CHECKED GOOD SEE NRWC 687-DFW-01907 FOR R & R OF GALLEY LIGHOct 2, 2014 · N687JS · Emb EMB145LR · Passenger Compartment LightingSDR SIMA20141002002Connector · not seatedEMERGENCY LIGHT LOWER INVERTER BEHIND GALLEY CEILING PANEL CONNECTOR NOT LOCKED INTO RECEPTACLE. LOCKED EMER LIGHT LOWER INVERTER BEHIND GALLEY CEILING PANEL CONNECTOR INTO RECEPTACLE IAW 145 AMM 33-50-11. OPERATIONS CHECKED GOOD.Oct 2, 2014 · N687JS · Emb EMB145LR · Light System WiringSDR SIMA20141002003Ballast · odorBALLAST IN GALLEY HAVE STRONG ELEC BURNING SMELL. R & R BOTH BALLASTS IN GALLEY IAW MM 33-29-05. OPERATIONS CHECKED GOOD.Oct 2, 2014 · N687JS · Emb EMB145LR · Passenger Compartment LightingSDR ASOA20141002290Stringer · crackedDURING A C-CHECK. STRINGER 6R FOUND CRACKED AT FRAME 13. R & R THE STRINGERIAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 2, 2014 · N13955 · Emb EMB145LR · Fuselage Main, Longeron/StringerSDR SIMA20141001008Support · crackedLEFT OVERWING PANEL SUPPORT FLANGE IS CRACKED AT FRAME 48. REPAIRED LT OVERWING PANEL SUPPORT FLANGE AT FRAME 48 IAW SRM 53-23-12.Oct 1, 2014 · N600BP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20141001007Bracket · crackedRIGHT OVERWING PANEL SUPPORT FLANGE HAS A CRACKED BRACKET AT FRAME 48. R & R RT OVERWING SUPPORT FLANGE BRACKET IAW SRM CH 51-40-02.Oct 1, 2014 · N600BP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20141001006Support Angle · crackedSUPPORT ANGLE CRACKED, AFT OF THE RT MLG WELL FOR THE AFT BELLY FAIRING. R & R BRACKET IAW SRM CH 51-40-02.Oct 1, 2014 · N600BP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20141001005Printer · failedPRINTER STARTED SMOKING & STOPPED PRINTING. R & R ACARS PRINTER IAW AMM 23-22-02. OPS CHECKED GOOD IAW AMM 23-22-02-700-801-A.Oct 1, 2014 · N693AE · Emb EMB145LR · Data Transmission Auto CallSDR SIMA20141001003Inverter · inoperativeCOCKPIT STEP & FIRST OVERHEAD CEILING LONG EMER LIGHTS INOPERATIVE. R & R IAW AMM 33-50-11. PERFORMED OPERATIONS CHECK IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.Oct 1, 2014 · N905JH · Emb EMB145LR · Emergency LightingSDR SIMA20141001002Flashlight · brokenFLIGHT ATTENDANT`S EMER FLASHLIGHT HAS A BROKEN ON & OFF BUTTON. R & R IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.Oct 1, 2014 · N619AE · Emb EMB145LR · Emergency EquipmentSDR ASOA20140930121Smoke Warning · false activationCREW REPORTED A LAVATORY SMOKE MESSAGE ON EICAS AFTER TAKE OFF. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT, LAV WIRING WITH NO DEFECTS NOTED, R & R FOUR FLUORESCENT LIGHT BULBS AS A PRECAUTION AND THE ACFT WAS APPROVED FOR RETURN TOSep 30, 2014 · N12996 · Emb EMB145LR · Smoke DetectionSDR RAIA201409300001Acm · seizedCREW REPORTED SMOKE IN CABIN AND COCKPIT DURING CLIMB, RETURNED TO DEPARTURE. MAINTENANCE INSPECTED AND REPLACED NR 1 ACM, OPS CHECKED GOOD.Sep 30, 2014 · N838HK · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20140930003Structure · damagedDURING 5A INSPECTION RT ELEVATOR TIP, TWO EACH AFT SCREW NUTPLATE ATTACHMENT HOLES DAMAGED BY LIGHTNING STRIKE. SATISFACTORILY ACCOMPLISHED ERS-EM-55MR-170.Sep 30, 2014 · N688AE · Emb EMB145LR · Elevator Miscellaneous StructureSDR SIMA20140930002Skin · crackedLEFT AFT FUSELAGE FRAME 75 STRINGER 2L UPPER AREA, SKIN CRACKED AT FASTENER. ACCOMPLISHED REPAIR IAW ERS-EM-53MR-755.Sep 30, 2014 · N658AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20140929004Valve · brokenLEVER ON DRAIN PORT OF EXTERNAL LAVATORY SERVICE DUMP VALVE IS BROKEN. REMOVED AND REPLACED LAVATORY TANK IAW 38-32-01, OPS CHECKED GOOD.Sep 29, 2014 · N656AE · Emb EMB145LR · Waste Disposal SystemSDR RAIA201409290001Door · openLOUD VIBRATION FROM NOSE AREA AFTER TAKEOFF AND DURING CLIMB, RETURN TO DEPARTURE. MAINTENANCE INSPECTED AND FOUND FWD GPU DOOR OPEN WITH DAMAGED. MAINTENANCE FOUND NO OTHER HIDDEN DAMAGE AND REMOVED DOOR IAW CDL.Sep 29, 2014 · N834HK · Emb EMB145LR · Accessory Compartment DoorsSDR SIMA20140929003Inverter · inoperativeEMERGENCY FLOOR LIGHT STRIP INOPERATIVE IN CTR OF CABIN. R & R EMER LIGHT DC & AC INVERTER NR 5 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.Sep 29, 2014 · N695AE · Emb EMB145LR · Emergency LightingSDR SIMA20140929001Strut · lowEICAS MSGS, ENG 1 - 2 REV DISAGREE, LG AIR GND FAIL. FOUND NOSE STRUT FLAT. SERVICED NOSE STRUT IAW AMM 32-20-01 WITH NITROGEN & OIL. OPERATIONS CHECKED GOOD.Sep 29, 2014 · N643AE · Emb EMB145LR · Nose/Tail Landing Gear Strut/AxleSDR SIMA20140929002Door Seal · obstructedMAIN CABIN DOOR DIFFICULT TO OPEN WITH HANDLE IN FULL OPEN & UNLATCH POSITION. WIPED OFF DUST FROM EXPOSED SURFACES OF DOOR FRAME SEAL & REMOVED REMNANTS OF EXPIRED SECURITY STICKERS FROM SAME. COULD NOT DUPLICATE DISCREPANCY. MAIN CABIN DOOR OPERATES NORMSep 29, 2014 · N617AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20140928006Light · crackedLEFT EMER LIGHT NR 3 EXTRUSION IS CRACKED. R & R LT EMER LIGHT NR 3 EXTRUSION IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20140928007Light · crackedRIGHT NR 4 EMER LIGHT EXTRUSION IS CRACKED. R & R RT NR 4 EMER LIGHT EXTRUSION IAW AMM 33-50-12.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20140928005Light · crackedLEFT EMER LIGHT NR 5 EXTRUSION IS CRACKED & LIGHT HAS A BROKEN WIRE. R & R LT EMER LIGHT NR 5 EXTRUSION LIGHT STRIP IAW AMM 33-50-12, IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20140928004Wire · brokenLEFT EMER LIGHT NR 4 HAS A BROKEN WIRE. R & R LT EMER LIGHT NR 4 IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Light System WiringSDR SIMA20140928003Light · crackedLEFT EMER LIGHT NR 7 EXTRUSION IS CRACKED. R & R LT EMER LIGHT NR 7 EXTRUSION IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20140928002Light · crackedLEFT EMER LIGHT NR 8 EXTRUSION IS CRACKED. R & R LT EMER LIGHT NR 8 EXTRUSION IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20140928008Light · crackedLEFT EMER LIGHT NR 2 EXTRUSION IS CRACKED. R & R LT EMER LIGHT NR 2 EXTRUSION IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.Sep 28, 2014 · N600BP · Emb EMB145LR · Emergency LightingSDR RAIA201409280001Bulb · inoperativeLEFT OVERWING EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.Sep 28, 2014 · N841HK · Emb EMB145LR · Emergency LightingSDR CHQA20140928282Light · inoperativeDURING INSPECTION AN AFT FLOOR PROXIMITY EMER LIGHT STRIP WAS FOUND TO BE INOPERATIVE. REPLACED THE FLOOR PROXIMITY EMER LIGHT STRIP. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.Sep 28, 2014 · N577RP · Emb EMB145LR · Emergency LightingSDR CHQA20140927287Fitting · crackedDURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81& STRINGER 8R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW SRM 51-40-02.Sep 27, 2014 · N567RP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR CHQA20140927286Fitting · crackedDURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81 & STRINGER 9R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW SRM 51-40-02.Sep 27, 2014 · N567RP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR CHQA20140925283Angle · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE RAMP ANGLE AT FRAME 20. THE RAM ANGLE WAS REPLACED IAW SRM 51-40-02.Sep 27, 2014 · N272SK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR CHQA20140927281Wire Harness · damagedTHE CREW REPORTED THAT THERE WAS AN ELEC SMELL IN THE FWD CABIN. REPLACED THE CEILING LIGHT HARNESS ASSEMBLY AT ROW 8. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.Sep 27, 2014 · N273SK · Emb EMB145LR · Light System WiringSDR SIMA20140927005Cradle · brokenFLIGHT ATTENDANT REPORTS THAT AFT CABIN FLASHLIGHT CRADLE IS BROKEN & WILL NOT CHARGE UNLESS HELD IN PLACE. R & R IAW AMM-33-51-01. OPERATIONS CHECKED GOOD.Sep 27, 2014 · N905JH · Emb EMB145LR · Emergency EquipmentSDR SIMA20140927004Handle · malfunctionedPARKING BRAKE VERY DIFFICULT TO OPERATE. COMPLIED WITH PARKING BRAKE HANDLE SERVICING IAW AMM 32-44-01. OPERATIONS CHECKED GOOD.Sep 27, 2014 · N677AE · Emb EMB145LR · Landing Gear Brake SystemSDR SIMA20140927003Connector · unsecureEMERGENCY LIGHTING STRIPS FROM 3A TO 7A INOPERATIVE. SECURED CONNECTOR FOR EMER LIGHTS IAW AMM 33-50-08.Sep 27, 2014 · N696AE · Emb EMB145LR · Light System WiringSDR SIMA20140927002Thermal Switch · faultyBLEED 2 LEAK ON EICAS. PERFORMED FIM TASK 36-20-00-810-802A. REPAIRED THERMAL SWITCH ON NR 2 BLEED SYS IAW WM 36-21-50. OPERATIONS CHECKED GOOD, NO MSG NOTED.Sep 27, 2014 · N637AE · Emb EMB145LR · Pneumatic Indicating SystemSDR RAIA201409260001Bulb · inoperativePASSENGER DOOR EMERGENCY LIGHT INOPERATIVE, MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.Sep 26, 2014 · N811HK · Emb EMB145LR · Emergency LightingSDR SIMA20140926005Warning System · false activationDURING HIGH SPEED TAXI & ABORT 80 - 90 KNOTS, WE GOT A TAKEOFF CONFIG ON EICAS & MASTER WARNING. SPOILERS INDICATED OPEN ON EICAS. COMPLIED WITH OPERATIONS CHECK FOR SPOILER SYS IAW ETM-27-165. COMPLIED WITH CONFIG WITH WARNING. OPERATIONS CHECKED GOOD IAWSep 26, 2014 · N657AE · Emb EMB145LR · Drag Control SystemSDR SIMA20140926003Inverter · inoperativeRIGHT OVERWING EMER EXIT IDENTIFIER PANEL INOPERATIVE. R & R EMER LIGHT DC AC INVERTER IAW AMM 33-50-11. ALL OPERATIONS CHECKED GOOD.Sep 26, 2014 · N659AE · Emb EMB145LR · Emergency LightingSDR SIMA20140926001Signal Cond Unit · inoperativeAFTER TAKEOFF LOST ALL FUEL INDICATION. MFD & EICAS INOPERATIVE REMAINDER OF FLIGHT. R & R FUEL CONDITION SIGNAL UNIT IAW MM 28-41-01 & PERFORMED OPERATIONS CHECK IAW MM 28-41-00, NO DASHES SHOWN.Sep 26, 2014 · N653AE · Emb EMB145LR · Fuel Indicating SystemSDR CHQA20140925285Support · corrodedDURING INSPECTION THE RT RAMP SUPPORT WAS FOUND TO BE CORRODED. THE RT RAMP ANGLE WAS REPLACED IAW SRM 51-40-02 & ETD 2014-145-08-1412.Sep 25, 2014 · N272SK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR CHQA20140925284Profile · corrodedDURING INSPECTION THE PROFILE FWD OF THE RAMP ANGLE AT FRAME 20 WAS FOUND TO BE CORRODED. THE PROFILE WAS REPAIRED IAW SRM 53-21-10.Sep 25, 2014 · N272SK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20140925010Fitting · corrodedFRAME 68 SHEAR CLIP AT CARGO DOOR CUT OUT CORRODED. REPAIRED IAW EM-53MR-1129 PART B.Sep 25, 2014 · N649PP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20140925009Fitting · corrodedFRAME 65 SHEAR CLIP AT CARGO DOOR CUT OUT CORRODED. SATISFACTORILY ACCOMPLISHED EM-53MR-1129.Sep 25, 2014 · N649PP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20140925004Light · inoperativeSEAT 12A EMER EXIT LIGHT INOPERATIVE. R & R EMER EXIT LIGHT AT 12 A IAW AMM 35-50-13. OPERATIONS CHECKED GOOD.Sep 25, 2014 · N636AE · Emb EMB145LR · Emergency LightingSDR SIMA20140925007Battery · dischargedAFT EMER LIGHTS WILL NOT ILLUMINATE. R & R NR 4 EMER LIGHT BATTERY & CHARGER ASSEMBLY. OPERATIONS CHECKED GOOD IAW WORK CARD 33-700-19. BATTERY CHARGER ASSEMBLY PN 11-0049 SN 14895.Sep 25, 2014 · N620AE · Emb EMB145LR · Emergency LightingSDR SIMA20140925008Light · inoperativeEMERGENCY FLOOR LIGHTING STRIP AT ROW 12 - 13 INOPERATIVE. R & R EMER FLOOR LIGHTING STRIP AT ROW 12 - 13 IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.Sep 25, 2014 · N606AE · Emb EMB145LR · Emergency LightingSDR SIMA20140925005Charger · inoperativeEMERGENCY FLOOR STRIP ON SEAT 10A & 11A INOPERATIVE. R & R BATTERY CHARGER ASSEMBLY & HOLDER ASSEMBLY BATTERY IAW AMM 33-50-04. OPERATIONS CHECK WAS GOOD AT THIS TIME. EMER LIGHTING BATTERY PN 2013-1A SN 108497.Sep 25, 2014 · N605KS · Emb EMB145LR · Emergency Lighting
Back to Embraer EMB-145LR