SDR SIMA201130707Battery · dischargedFOR PS -1 MAINTENANCE CHECK FOUND SEAT ROW 1-6 FLOOR EMERGENCY LIGHTS INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 2 EMERGENCY SUPPLY BATTERY AND HOLDER ASSEMBLY. THE OPERATIONAL CHECK WAS GOOD IAW W/C 33-700-17. THE AIRCRSDR SIMA2011313009Wire Harness · shortedDURING MAINTENANCE INSPECTION WHILE TROUBLESHOOTING FOUND NR 1 ENGINE FIRE DECT HARNESS WIRE W 4070012-20 SHORTED TO SHIELDING. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE ENGINE NR 1 HARNESS FOR FIRE DETECTION SYSTEM IAW EMB 145 AMM 71-SDR C2XA11IA247Solenoid Valve · inoperativeICT - FLIGHT 5931, THE CREW REPORTED A VERY LOUD NOISE FROM TAKEOFF TO LANDING, AND BELIEVED THAT THE NLG DOORS WERE OPEN. THE AIRCRAFT RETURNED TO ICT WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NOSE LANDING GEAR SOLENOID VALVE, OSDR SIMA2011319009Battery · dischargedDURING MAINTENANCE BASE VISIT FOUND THE EMERGENCY EXIT LIGHTS AT THE SERVICE DOOR INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 2 BATTERY POWER SUPPLY AND HOLDER IAW EMB 145 AMM 33-50-04. THE OPERATIONAL CHECK WAS GOOD. THESDR SIMA201131201Floor Support · corrodedDURING MAINTENANCE BASE VISIT FOUND THE LEFT OMEGA BEAM HAS SIDE CORROSION FRETTING AND CORROSION AROUND THE NUTPLATE BETWEEN FRAMES 19-24. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED LEFT OMEGA BEAM IAW SRM 53-21-10. THE AIRCRAFT WAS RETURNED TO SERVICSDR C2XA11RI174Structure · damagedFLT 5864 PWM CREW REPORTED A BIRD STRIKE ON TAKEOFF AND PERFORMED AN AIR RETURN BACK TO PWM WITHOUT INCIDENT. NORTHEAST AVIATION MX PERFORMED BIRD STRIKE INSPECTION IAW EMB145 AMM 05-50-08 WITH DAMAGE NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201130701Sill · corrodedDURING MAINTENANCE INSPECTION FOUND CARGO DOOR SILL WITH SEVERAL SPOTS OF CORROSION. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE CARGO DOOR SILL IAW SRM 51-40-02. AIRCRAFT RETURNED TO SERVICE.SDR CHQA201100422Hydraulic System · lowCREW REPORTED THAT AFTER LANDING GEAR RETRACTION RECEIVED A HYDRAULIC SYSTEM 1 LOW QUANTITY MESSAGE. THE CREW CONTINUED TO MONITOR THE HYDRAULIC SYSTEM DURING THE FLIGHT. THE LEVELS CONTINUED TO DROP. AN EMERGENCY WAS DECLARED BY CHARLESTON APPROACH. THE ASDR SIMA201130708Battery · dischargedFOR PS -1 MAINTENANCE CHECK FOUND THE AFT EMERGENCY LIGHTS INOPERABLE. THE AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 4 BATTERY AND CHARGER ASSEMBLY IAW AMM 33-50-04. THE OPERATIONAL CHECK WAS GOOD IAW W/C 33-70-17. THE AIRCRAFT WAS RETURNESDR SIMA201130706Battery · dischargedFOR FLIGHT 2789 MAINTENANCE FOUND THE COCKPIT FLOOD LIGHT AND 1ST AISLE EMERGENCY LIGHTS INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NUMBER 1 EMERGENCY POWER SUPPLY UNIT CHARGER ASSEMBLY AND BATTERY IAW EM AMM 33-50-0. THE OPSDR SIMA201130501Proximity Sensor · inoperativeON FLIGHT 2780 THE CREW REPORTED AT 34,000 FEET WITH CRUISE THRUST SETTING RECEIVED EICAS MESSAGE "SPOILER FAIL" AND GREEN SPOILER "OPEN" INDICATION. THE CREW COMPLIED WITH AOM PROCEDURES FOR INADVERTENT SPOILER OPENING IN FLIGHT. AFTER PULLING CB`S F13 F14 SDR C2XA11CL239Switch · faultyBNA FLT 5955 THE CREW REPORTED THE NR 1 BLEED VALVE WOULD NOT OPEN DURING FLIGHT. CLOSED INDICATION ON THE EICAS. THE AIRCRAFT RETURNED TO BNA AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 1 BLEED VALVE PUSHBUTTON SWITCH. OSDR C2XA20111029172Control Panel · smokeFLT 6161,ON GROUND, CREW REPORTED NR 2 HYDRAULIC PUMP SWITCH FAILED ASSOCIATED WITH SMOKE IN THE COCKPIT. MX REMOVED AND REPLACED HYDRAULIC CONTROL PANEL IAW AMM 20-10-10, OPS CHECKED SUCCESSFUL. ACFT RETURNED TO SERVICE.SDR CHQA201100421Control Unit · inoperativeCREW REPORTED THAT DURING DESCENT RECEIVED AN AUTOPILOT FAIL MESSAGE. WHILE REFERENCING THE QUICK REFERENCE HANDBOOK, CREW THEN RECEIVED PITCH TRIM MAIN AND PITCH TRIM BACK-UP INOP MESSAGES ON THE EICAS. THE CREW REGAINED USE OF THE AUTOPILOT SYSTEM. THE CSDR RAIA201110290001Pressure Switch · malfunctionedDURING CLIMB THE FLIGHT CREW GOT A STAB ANTI-ICE FAIL INDICATION AND AIRCRAFT WAS IN ICING CONDITIONS. AIRCRAFT RETURNED TO CVG. MAINTENANCE INSPECTED AND REMOVED AND REPLACED PRESSURE SWITCHES. SYSTEM OPS CHECKED GOOD.SDR SIMA201130404Shutoff Valve · leakingON FLIGHT 3314 THE CREW REPORTED A FUEL SEAP ON THE LEFT WING INFLIGHT. THE CREW ELECTED TO DIVERT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT SHUTOFF VALVE IAW EMB AMM 28-23-02. THE LEAK CHESDR SIMA201130403Ecu · inoperativeON FLIGHT 4142 ON APPROACH THE CREW REPORTED THEY RECEIVED A CAPTAINS PITCH TRIM FAIL MESSAGE AND FLAP FAIL MESSAGE. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CAPTAIN’S CONTROSDR C2XA11TY166Relay · brokenTYS FOR BNA A/C ON CLIMBOUT HAD A EICIAS WITH A MESSAGE THAT THE NR 1 BLEED VALVE WAS CLOSED IN FLIGHT. THE CREW RETURNED TO BNA AND SWAPPED A/C. MAINTENANCE REMOVED AND REPLACED THE PUSHBUTTON IAW EMB 145 AMM 20-13-04. OPS CHECK GOOD. OPS CHECKED THE NR SDR RAIA201110280001Strip · looseDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY LIGHT STRIP BY GALLEY WAS LOOSE. MAINTENANCE INSPECTED AND RE-SECURED THE LIGHT STRIP. SYSTEM OPS CHECKED GOOD.SDR SIMA201130402Drive Unit · failedON FLIGHT 4190 THE CREW REPORTED THAT ON APPROACH THEY HAD A FLAP FAIL. THE CREW DECLARED AND EMERGENCY. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED FLAP DRIVE UNIT IAW EMB AMM 27-53-04. THE OPERATIONASDR SIMA201130101Light · inoperativeFOR FLIGHT 3541 THE CREW REPORTED THE LEFT OVERWING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LAMP IAW 33-50-10. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR RAIA201110270001Channel · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE CARGO DOOR Z-CHANNEL HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED THE CARGO DOOR Z-CHANNEL.SDR SIMA201130802Rib · crackedDURING MAINTENANCE VISIT FOUND THE RIGHT WING 5 CRACKED. THE AIRCRAFT WAS REMOVED FROM SERIVCE. COMPLIED WITH AEA EO EM-57MR-587. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA201130801Rib · crackedDURING MAINTENANCE VISIT FOUND THE LEFT WING 5 CRACKED. THE AIRCRAFT WAS REMOVED FROM SERIVCE. COMPLIED WITH AEA EO EM-57MR-588. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA11IA243Power Supply · inoperativeIAH - DURING MAINTENANCE INSPECTION THE LEFT EXTERIOR EMERGENCY LIGHT, FWD WING LIGHT, NR 1 CABIN AISLE PATH LIGHT, AND COCKPIT FLOOD LIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE EMERGENCY LIGHT POWER SUPPLY, OPERATIONALSDR C2XA11CL238Switch · faultyORD FLT 6092 THE CREW REPORTED A BLEED 1 VALVE CLOSED MESSAGE AFTER TAKEOFF. MESSAGE DID NOT CLEAR. THE AIRCRAFT RETURNED TO ORD AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 1 BLEED VALVE PUSHBUTTON SWITCH. OPERATIONAL CHECKS WERESDR RAIA201110260004Sill · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE LT FWD SILL FROM FRAMES 19-23 HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED LT FWD SILL.SDR RAIA201110260003Doubler · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE DOUBLERS AT FRAMES 20 AND 22 ON RT BEAM HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED THE DOUBLERS FRAMES 20 AND 22 ON RT BEAM.SDR RAIA201110260002Gusset · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE A GUSSET BETWEEN FRAMES 16-18 FWD OF RAMP HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACE GUSSET BETWEEN FRAMES 16-18.SDR RAIA201110260001Seat Track · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE VERY MOST FWD LT SEAT TRACK HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACE FWD LT SEAT TRACK.SDR C2XA20111026242Probe · malfunctionedFLIGHT 4433, NR 2 FUEL QTY INDICATOR FLUCTUATING. ACFT DIVERTED & LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NR 2 TANK UNIT, OPERATIONALLY CHECKED WITH NO DEFECTS, AND ACFT RETURNED TO SERVICE.SDR CHQA201100420Pressure Switch · brokenCREW REPORTED, RECEIVED A BLEED 2 OVERTEMP MESSAGE DURING CLIMB. THE CREW DIVERTED TO KCMH AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE RIGHT ENGINE HIGH STAGE PRESSURE SWITCH TO BE BROKEN INTO TWO PIECES. THE RIGHT ENGINE HIGH STAGE PRESSURE SWITCH WSDR CHQA201100419Light · inoperativeDURING INSPECTION, THE NUMBER 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIP WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NUMBER 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIP. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA2011301004Flashlight · inoperativeFORWARD PASSENGER CABIN EMERGENCY FLASH LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FORWARD PASSENGER CABIN EMERGENCY FLASHLIGHT ASSEMBLY IAW EMB145 AMM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNSDR RAIA201110250008Gusset · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE GUSSETT ON CENTER BEAM BETWEEN FRAMES 19-23 HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACE GUSSETT ON CENTER BEAM BETWEEN FRAMES 19-23.SDR RAIA201110250007Sill · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE AFT SERVICE DOOR SILL HAS LEVEL 2 CORROSION. MAINTENANCE INSTALLED FWD AND AFT DOUBLER ON THE AFT SERVICE DOOR SILL.SDR RAIA201110250006Sill · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE CENTER SERVICE DOOR SILL HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACE CENTER SERVICE DOOR SILL.SDR RAIA201110250005Sill · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE FWD SERVICE DOOR SILL HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED FWD SERVICE DOOR SILL.SDR RAIA201110250004Structure · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE PASSENGER DOOR U-SHAPES HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED THE PASSENGER DOOR U-SHAPES.SDR RAIA201110250003Beam · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE PREVIOUSLY REPAIRED LEFT BEAM AT FRAME 20 HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED REPAIR LEFT BEAM AT FRAME 20.SDR RAIA201110250002Support Angle · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE RAMP SUPPORT ANGLE ON LEFT BEAM BETWEEN FRAMES 19-20 HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACE RAMP SUPPORT ANGLE ON LEFT BEAM.SDR RAIA201110250001Support Angle · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE RAMP SUPPORT ANGLE ON CENTER BEAM BETWEEN FRAMES 19-20 HAS LEVEL 2 CORROSION. MAINTENANCE REMOVED AND REPLACED THE RAMP SUPPORT ANGLE.SDR CHQA201100418Wire Harness · faultyCREW REPORTED, RECEIVED A LANDING GEAR AIR/GROUND FAIL MESSAGE IN FLIGHT. RETURNED TO KCAE AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS FERRIED TO KCMH WITH THE LANDING GEAR DOWN AND THE LOCKING PINS INSTALLED. CMH MAINTENANCE ADJUSTED THE RIGHT FORWARD PRSDR CHQA201100416Relief Valve · inoperativeCREW REPORTED THAT UPON GEAR RETRACTION THERE WAS A LOUD RUSHING WIND NOISE BELOW THE FLIGHT DECK. GEAR INDICATIONS SHOWED THE LANDING GEAR TO BE UP AND LOCKED. THE CREW RETURNED TO KSAV AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS FERRIED TO KCMH WITH THSDR SIMA2011300006Life Vest · unserviceableDURING MAINTENANCE INSPECTION FOUND THE OBSERVER SEAT LIFE VEST BAG TORN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE OBSERVER SEAT LIFE VEST IAW EMB 145 EEL. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA2011300005Potentiometer · brokenFOR FLIGHT 4176 THE CREW REPORTED THE NOSE WHEELS PRESENTED ERRATIC BEHAVIOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND RUDDER PEDAL POTENTIOMETER STUD BROKEN. REMOVED AND REPLACED POTENTIOMETER IAW EMB 145 AMM 32-50-02. THE OPERATIONAL CHECK WAS GOOD. SDR SIMA201129901Light · inoperativeDURING MAINTENANCE BASE VISIT FOUND THE LEFT WING AFT OVERWING EMERGENCY EXIT LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT WING AFT OVERWING EMERGENCY EXIT LIGHT IAW EMB 145 AMM 33-50-10 SUBTASK 33-50-10-020-003-A00 SDR C2XA11SH162Door Frame · corrodedSHV - DURING C-CHECK PAX DOOR FRAME LOWER SECTION HAS CORRODED NUT PLATE HOLES (NEAR DOOR SEAL). MAINTENANCE PERFORMED REPAIR AT PAX DOOR LOWER NUT PLATE AREAS IAW EC5210-01154. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH161Skin · gougedSHV - DURING C-CHECK BAGGAGE DOOR INNER FRAME SKIN GOUGED AT LOWER, FWD AND CENTER AREAS. MAINTENANCE PERFORMED REPAIR ON BAGGAGE DOOR INNER SKIN IAW EC5230-01208. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH160Frame · corrodedSHV - DURING C-CHECK CORROSION PRESENT IN AREA WHERE THE SHUNT CONNECTION BAR COMES IN CONTACT WITH STRUCTURE. MAINTENANCE PERFORMED REPAIR AT APU SHUNT FRAME 80 IAW EC5310-01544 REV C, BONDING CHECK GOOD. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
Back to Embraer EMB-145LR