Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CHQA201100437Battery · dischargedDURING INSPECTION, THE LEFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NUMBER 3 EMERGENCY LIGHT BATTERY, OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA2011315002Power Supply · inoperativeDURING MAINTENANCE INSPECTION FOUND THE EMERGENCY POWER SUPPLY NR 4 AND THE EMERGENCY CHARGER ASSEMBLY NR 4 INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED NR 4 EMERGENCY POWER SUPPLY AND THE REMOVED AND REPLACED NR 4 EMERGENCY BATTESDR C2XA11CL246Control Unit · faultyCLE - FLT 4281 THE CREW REPORTED AFTER LANDING INITIAL BRAKING WAS GOOD THEN A LOSS OF BRAKING, RECEIVED A BRAKE DEGRADE MESSAGE THEN WENT AWAY. BRAKE TEMP WAS HIGH ON THE INBOARD BRAKES. MAINTENANCE INSPECTED AND REPLACED THE BRAKE CONTROL UNIT. OPERATIONASDR SIMA2011356001Connector · damagedDURING MAINTENANCE BASE VISIT FOUND THE EMERGENCY LIGHT STRIP REMOVABLE SPLICE CONNECTORS (A/C SIDE) AT POSTIONS 3 AND 6 DAMAGED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED EMERGENCY LIGHT STRIP REMOVABLE SPLICE CONNECTORS (A/C SIDE) AT POSTIONS 3 AND 6SDR C2XA11RI178Flashlight · meltedFLT 4154 EWR - CREW REPORTED A ELECTRICAL SMELL NEAR MAIN CABIN DOOR WITH OBSERVATION OF F/A FLASHLIGHT MELTED. EWR MX REMOVED AND REPLACED THE FWD F/A FLASHLIGHT AND CRADLE ASSY IAW EMB 145 AMM 33-50-16 WITH OPERATIONAL CHECK SUCCESSFUL. ACFT WAS APPROVED FSDR SIMA2011315001Rod End · corrodedFOR FLIGHT 4366 THE DURING UNSCHEDULED MAINTENANCE CHECK FOUND THE AFT RUDDER II LOWER CONTROL SPHERICAL ROD END CORRODED AND SEIZED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE RUDDER II PUSH ROD END IAW EMB 145 AMM 27-21-08. PART NUMBESDR SIMA2011314004Battery · dischargedDURING MAINTENANCE INSPECTION FOUND THE EMERGENCY BATTERY NR 1 INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE EMERGENCY BATTERY NR 1 IAW EMB 145 AMM 33-50-04. THE OPERATIONAL CHECK WAS GOOD, THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA2011314003Light · inoperativeDURING MAINTENANCE INSPECTION FOUND THE LEFT FORWARD OUTSIDE EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. RELAMPED THE LEFT FORWARD EMERGENCY LIGHT. THE OPERATIONAL CHECK WAS GOOD PER EMB AMM 33-50-10. THE AIRCRAFT WAS RETURNED TO SERSDR SIMA2011313007Unknown · smokeON FLIGHT 3325 THE TOWER REPORTED SMOKE COMING OFF GEAR DURING LANDING ROLLOUT. REPORTED SMOKE STOPPED BEFORE EXITING RUNWAY. COULD NOT DETERMINE WHICH SIDE. THE AIRCRAFT WAS DE-ICED EARLIER. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED MAIN LANDING GSDR SIMA201131304Skin · crackedDURING MAINTENANCE BASE VISIT FOUND FORWARD FUSELAGE II SKIN CRACKED AT LEFT WINDSHIELD SIDE POST UPPER END. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED IAW EO EM-53MR-1890. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA11IA255Smoke Detector · malfunctionedMCI - THE LAV SMOKE DETECTOR WAS REPORTED AS MALFUNCTIONING. MAINTENANCE REMOVED AND REPLACED THE SMOKE DETECTOR, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA201111080002Switch · malfunctionedDURING CLIMB THE FLIGHT CREW GOT A BLEED LEAK MESSAGE ON EICAS. AIRCRAFT RETURNED TO ORD. MAINTENANCE INSPECTED AND DEFERRED PACK NR 2 PER MEL 21-51-00-1. CLEARED NR 1 PACK MEL 21-51-00-1. SWAPPED NR 1 & NR 2 PACK OVERPRESSURE SWITCHES. SYSTEM OPS CHECKEDSDR RAIA201111080001O-Ring · leakingDURING CLIMB THE FLIGHT CREW GOT A BLEED NR 2 LEAK MESSAGE. AIRCRAFT RETURNED TO ORD. MAINTENANCE INSPECTED AND REMOVED AND REPLACED BLEED LINE O-RINGS AT COUPLING NR 29 NEAR VERTICLE STAB ANTI-ICE VALVE. SYSTEM OPS CHECKED GOOD.SDR SIMA2011313004Light · malfunctionedON FLIGHT 3305 THE CREW REPORTED THE SIDE LIGHTING IN CABIN, RIGHT SIDE FROM 5TH ROW THRU 12 ROW AND 15 ROW THRU 18, AND LEFT SIDE FROM ROW 9 THRU 11 AND 15 THRU 18 STOPPED WORKING; ACRID SMELL ACCOMPANIED. THE AIRCRAFT WAS REMOVED FROM SERVICE. INSPECTED SISDR SIMA2011313003Connector · disconnectedDURING MAINTENANCE INSPECTION FOUND THE RIGHT OVERWING EXIT AFT EXTERNAL EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND CONNECTOR ON RIGHT AFT EXTERNAL OVERWING EMERGENCY LIGHT NOT CONNECTED. CONNECTED CONNECTOR IAW EMB-145 AMM 33-SDR C2XA11CL243Proximity Switch · faultyCLE FLT 5815 THE CREW REPORTED A LANDING GEAR AIR GROUND FAIL MESSAGE AND WAS UNABLE TO RAISE GEAR ON DEPARTURE. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE RIGHT GEAR WOW PROXIMITY SWITCHES. OPERATIONAL SDR SIMA201131301Connector · looseDURING MAINTENANCE BASE VISIT FOUND THE RIGHT OVERWING EXIT AFT EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. RE-SECURED CONNECTOR ON LIGHT ASSEMBLY. NO PARTS REMOVED OR REPLACED. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURSDR CHQA201100436Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 53. MAINTENANCE REPAIRED THE FLOOR SILL AT FRAME 53 IN ACCORDANCE WITH ETD 2011-145-107752 WITH NO FURTHER DEFECTS NOTED.SDR CHQA201100435Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 49. MAINTENANCE REMOVED THE CORROSION AT FLOOR SILL FRAME 49 RIGHT SIDE. THE REMAINING THICKNESS WAS 0.045 INCHES, WITH CORROSION LESS THEN 30 PERCENT OF ORIGINAL MATERIAL THICKNESS. NOSDR CHQA201100434Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 44. MAINTENANCE REMOVED THE CORROSION AT FRAME 44 RIGHT FLOOR SILL. THE REMAINING THICKNESS WAS 0.044 INCHES, WITH LESS THAN 30 PERCENT OF THE THICKNESS REMOVED. NO CRACK INDICATIONS WESDR CHQA201100433Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LEFT FLOOR SILL AT FRAME 39. MAINTENANCE BLENDED THE CORROSION ON THE LEFT FLOOR SILL AT FRAME 39. CORROSION WAS FOUND TO BE LESS THAN 30 PERCENT, REMAINING MATERIAL THICKNESS WAS 0.038 INCHES. NO CRACK INDICATISDR CHQA201100432Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LEFT FLOOR SILL FROM FRAME 43 TO FRAME 44. MAINTENANCE REPLACED THE LEFT FLOOR SILL AT FRAME 43 TO FRAME 44 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100431Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LEFT FLOOR SILL AT FRAME 35. MAINTENANCE REPLACED THE LEFT FLOOR SILL AT FRAME 35 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100430Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LEFT FLOOR SILL AT FRAME 31. MAINTENANCE REPLACED THE LEFT FLOOR SILL AT FRAME 31 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100429Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 39. MAINTENANCE REPLACED THE FLOOR SILL AT FRAME 39 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100428Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 35. MAINTENANCE REPLACED THE FLOOR SILL AT FRAME 35 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100427Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 31. MAINTENANCE REPLACED THE FLOOR SILL AT FRAME 31 IN ACCORDANCE WITH SRM 51-40-02.SDR CHQA201100426Sill · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RIGHT FLOOR SILL AT FRAME 28. MAINTENANCE INSPECTED AND REMOVED THE CORROSION FROM THE FLOOR SILL AT FRAME 28 RIGHT. CORROSION WAS LESS THEN 30 PERCENT OF MATERIAL THICKNESS, THE REMAINING THICKNESS IS 0.041 INCHSDR C2XA11TY168Controller · malfunctionedFLIGHT CREW SMELLED SMOKE. REMOVED AND REPLACED WINDSHIELD HEATER CONTROLLER IAW EMB 145 30-42-01. OPS CHECK GOOD.SDR SIMA2011312006Light · malfunctionedDURING MAINTENANCE BASE VISIT FOUND THE FLOOR EMERGENCY ILLUMINATION STRIP AT ROWS 4-5 INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED AN OPERATIONAL CHECK OF THE EMERGENCY LIGHTS IAW EMB-145 AMM 33-50-00. NO DEFECTS NOTED AT THIS TIME. THE AISDR RAIA201111060004Beam · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE CARGO DOOR LOWER BEAM HAS CORROSION. MAINTENANCE REMOVED AND REPLACED THE CARGO DOOR LOWER BEAM.SDR RAIA201111060003Floor Support · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE LT OMEGA BEAM HAS CORROSION AT PREVIOUS REPAIR AT FRAME 20. MAINTENANCE REMOVED, FABRICATED REPLACEMENT PART AND REPLACED THE REPAIR ON THE LT OMEGA BEAM AT FRAME 20.SDR RAIA201111060002Gusset · corrodedDURING HEAVY CHECK INSPECTION MAINTENANCE FOUND THE GUSSETT ON RT OMEGA BEAM HAS CORROSION BETWEEN FRAMES 59 AND 61. MAINTENANCE REMOVED AND REPLACED THE GUSSETT ON RT OMEGA BEAM BETWEEN FRAMES 59 AND 61.SDR C2XA11RI176Light · malfunctionedDURING SCHEDULED MAINTENANCE INSPECTION, ROW 12 CEILING EMERGENCY LIGHT WOULD NOT ILLUMINATE. MX RESET SYSTEM AND OPERATIONALLY CHECKED THE LIGHT SUCCESSFULLY IAW EMB145 AMM 33-50-00-700-801A. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA201111060001Glowstrip · defectiveDURING POST-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY PHOTOLUMINESCENT LIGHT STRIP BY THE GALLEY WAS MISSING RED MARKS. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE PHOTOLUMINESCENT FLOOR LIGHT STRIP BY THE GALLEY. SYSTEM OPS CHECKED GOOSDR SIMA2011311002Control Lever · faultyFOR FLIGHT 2869 THE CREW REPORTED THAT ON TAKEOFF FROM DFW 18L, ON GEAR RETRACTION THE EICAS INDICATION WENT FROM 3 GREEN TO 3 DN AMBER, THEN TURN RED, EICAS WARNING LANDING GEAR LEVER DISAGREE INDICATION. CYCLE THE GEAR LEVER AS AOM 1 PROCEDURE, GOT 3 GREEN SDR SIMA2011312005Battery · dischargedDURING MAINTENANCE BASE VISIT FOUND THE NR 2 EMERGENCY LIGHTING SYSTEM FAILED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE EMERGENCY LIGHTING SYSTEM BATTERY NR 2 IAW WC 33-700-19. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNESDR SIMA201131105Wire Harness · defectiveON FLIGHT 3913 THE FLIGHT ATTENDANT NOTICED A "BURNING SMELL" BY MAIN CABIN DOOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND LIGHT SOCKET ON PASSENGER SIDEWALL LIGHT ASSEMBLY DS8411 BURNED. REPLACED WIRE HARNESS FROM BALLAST RT8500-231 TO LIGHT ASSYMBLY SDR SIMA201131103Flashlight · inoperativeFOR FLIGHT 3541 THE CREW REPORTED THE AFT CABIN FLASHLIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE AFT CABIN FLASHLIGHT AND CHARGER ASSY IAW EMB AMM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SDR SIMA2011312001Printed Ckt Board · malfunctionedON FLIGHT 3900 THE CREW REPORTED THE FLIGHT ATTENDANT CALL BUTTON LIGHTS FOR ROWS 7, 8, 9, 10 CAME ON UNCOMMANDED FOLLOWED BY REPORTS OF FUMES AND POSSIBLE LIGHT SMOKE. THE LIGHTS REMAINED ON UNTIL AIRCRAFT POWERED DOWN. THE AIRCRAFT LANDED WITHOUT INCIDENT.SDR C2XA11CL241Control Panel · faultyTHE CREW REPORTED A LAV SMOKE WARNING MESSAGE IN FLIGHT. MAINTENANCE INSPECTED AND REPLACED THE SMOKE DETECTOR CONTROL PANEL. OPERATIONAL CHECKS WERE GOOD.SDR SIMA201131101Ballast · inoperativeFOR FLIGHT 9301 THE CREW REPORTED THAT AS THEY PARKED AT GATE THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN GALLEY. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED LIGHT BALLAST RT8426 IAW AMM CH 33-21-03. THE OPERATIONAL CHECK WAS GOOD. SDR C2XA11CL240Control Unit · faultyCLE - FLT 4294 THE CREW REPORTED AN AUTO TRIM FAIL MESSAGE WHEN AUTOPILOT WAS ENGAGED. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE HORIZONTAL STAB CONTROL UNIT (HSCU). OPERATIONAL CHECKS WERE GOOD.SDR CHQA201100438Skin · damagedCREW REPORTED THAT THE AIRCRAFT WAS DAMAGED BY THE RAMP CREW BAGGAGE BELT LOADER, BELOW THE BAGGAGE PIT DOOR NEAR FRAME 67 AND STRINGER 19L. THE AIRCRAFT WAS FERRIED TO KCMH. CMH MAINTENANCE REPLACED THE SKIN (PN:145-35010-003 AND 145-23056-007) AND RE-CONTOUSDR C2XA11CL244Control Valve · faultyDTW FLT 5984 THE CREW REPORTED AN INBORAD BRAKES INOP MESSAGE ON TAKEOFF. THE CREW ABORTED TAKEOFF AND TAXIED BACK TO GATE. MAINTENANCE INSPECTED AND REPLACED THE INBOARD BRAKE CONTROL VALVE. OPERATIONAL CHECKS WERE GOOD.SDR C2XA11RI175Light · inoperativeDURING SCHEDULED MX INSPECTION RIC MX FOUND AISLE 12BC OVERHEAD EMERGENCY LIGHT INOPERATIVE. MX REMOVED AND REPLACED 12BC EMERGENCY LIGHT BULB IAW EMB145 AMM 33-50-08 WITH OPERATIONAL CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11IA248Contactor · inoperativeIAH - FLIGHT 4457 THE CREW REPORTED A BACKUP BATTERY OFF BUSS INDICATION IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE BACKUP BATTERY PUSHBUTTON SWITCH, AND CONTACTOR K0305, OPERATIONALLY TESTED SDR SIMA201130806Proximity Sensor · false indicationFLIGHT 2915, CREW REPORTED THAT AT 20,000 WITH CRUISE THRUST SETTING, RECIVED EICAS SPOILER FAIL, EICAS INDICATED SPOILER OPEN. COMPLIED WITH AOM 1 PROCEDURE FOR INADVENTENT SPOILER OPENING IN FLT. AFTER PULLING C/B F13, F14, &F21, CONTINUED TO GET AN INTERSDR SIMA201130809Printed Ckt Board · burnedON FLIGHT 3900 THE CREW REPORTED THE FLIGHT ATTENDANT CALL BUTTON LIGHTS FOR ROWS 7, 8, 9, 10 CAME ON UNCOMMANDED FOLLOWED BY REPORTS OF FUMES AND POSSIBLE LIGHT SMOKE. LIGHTS REMAINED ON UNTIL AIRCRAFT POWERED DOWN. THE AIRCRAFT WAS REMOVED FROM SERVICE. FSDR SIMA201130804Battery · dischargedFOR FLIGHT 3565 THE CREW FOUND ALL EMERGENCY LIGHTS TO BE INOPERATIVE. FOUND AC 610 WITH EMERGENCY LIGHTS IN ARMED POSITION. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE EMERGENCY LIGHTING SYSTEM POWER SUPPLIES (CHARGER NR 1, NR 3, NR 4 A
Back to Embraer EMB-145LR