Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR V0XR20110401006Floor Support · corroded(V0XR) CENTER OMEGA BEAM AT Y 0.0 BETWEEN FRAMES 17-24 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED OMEGA BEAM AT Y 0.0 BETWEEN FRAMES 17-24 IAW EMB145 SRM 51-10-02 AND 51-40-02. W/C 1117SDR V0XR20110401005Gusset · corroded(V0XR) RT GUSSET AT FRAME 53-59 CORRODED OUT OF LIMITS. REMOVED AND REPLACED GUSSET AT FRAME 53-59 IAW EMB145 SRM 51-40-02, 51-10-02, AND 51-20-03. W/C 1102SDR V0XR20110401001Gusset · corrodedCENTER GUSSET AT FRAME 19-23 IS CORRODED. REMOVED AND REPLACED CENTER GUSSET AT FRAME 19-23 IAW SRM 51-40-02 AND 51-20-03. W/C 1065SDR RAIA201104010001APrecooler · leakingDURING CLIMB THE FLIGHT CREW GOT A INDUCTION OF A NR 1 ENGINE BLEED AIR LEAK. AIRCRAFT RETURNED TO THE AIRPORT. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE PRECOOLER. SYSTEM OPS CHECKED GOOD.SDR C2XA11CL090Unknown · odorORD - THE CREW REPORTED A STRONG FUEL SMELL ON APU START-UP ON GROUND. MAINTENANCE INSPECTED AND PERFORMED OPERATIONAL TESTS OF APU. NO FUEL SMELL WAS NOTED.SDR C2XA11IA065Acm · inoperativeIAH - FLIGHT 2733 BHM TO IAH, THE CREW REPORTED A LITE HAZY SMOKE IN THE COCKPIT DURING CRUISE THAT DISSIPATED. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE ACM, OPERATIONALLY TESTED WITH NO DEFECTS, AND THSDR CHQA201100126Outflow Valve · inoperativeCREW REPORTED THAT DURING DESCENT FROM FL320 TO FL240 CABIN ALTITUDE STARTED INCREASING. THE CREW DECLARED AN EMERGENCY AND INCREASED THERE DESCENT RATE. THE AIRCRAFT LANDED KCLT WITHOUT INCIDENT. MAINTENANCE FOUND THE MANUAL PRESSURIZATION MODE TO BE OPERASDR SIMA201109409Smoke Detector · faultyON FLIGHT 2793 UPON LANDING THE CREW REPORTED, RECEIVED A BAGGAGE SMOKE WARNING MESSSAGE. THE BAGGAGE EXTINGUISHER BUTTON WAS PRESSED. THE CAPTAIN DECLARED AN EMERGENCY. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FORWARD AND AFT CARGO SDR SIMA201109408Engine · malfunctionedON FLIGHT 3958 DURING TAKEOFF THE CREW REPORTED, RECEVIED A "LAV SMOKE EICAS WARNING". THE FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN AND PASSENGERS SEATED AROUND ROW 11-14 REPORTED THE ODOR AS WELL. THE CAPTAIN ELECTED TO RETURN TO ORD AND LANDED WITHOUT ISDR CA110331019Beam · corroded(CAN) CORROSION LEVEL 3 FOUND ON CABIN FLOOR STRUCTURE, CTR FUSELAGE I MIDDLE BEAM, BETWEEN FRAME 17 & 25.SDR V0XR20110331008Strip · crackedRT UPPER WING-BODY FAIRING STRIP, NR 4 BACK IS CRACKED. REMOVED AND REPLACED RT UPPER WING-BODY FAIRING FAIRING STRIP IAW SRM 51-40-02. LOCATED AND DRILLED IAW SRM 51-20-03. W/C 2057SDR V0XR20110331007Strip · crackedRT UPPER WING-BODY FAIRING STRIP, NR 2 BACK IS CRACKED. REMOVED AND REPLACED RT UPPER WING-BODY STRIP NR 2 IAW SRM 51-40-02. LOCATED AND DRILLED IAW SRM 51-20-03. W/C 2056SDR V0XR20110331006Partition · corrodedRIGHT PARTITION AT FRAME 61 IS CORRODED OUT OF LIMITS. REPLACED CORRODED RT PARTITION AT FRAME 61 WITH NEW PART IAW SRM 51-10-02 AND 51-40-02. W/C 1084SDR V0XR20110331005Beam · corrodedBEAM AT FRAME 20 IS CORRODED OUT OF LIMITS. REMOVED OLD REPAIR, FABRICATED NEW REPAIR AND REPLACED IAW SRM 53-00-10, 51-20-03, 51-40-02, 51-30-01, 51-20-01, AND CPM 51-21-04, 51-20-05. W/C 1076SDR V0XR20110331004Profile · corrodedLEFT PROFILE AT FRAME 22 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED L/H PROFILE AT FRAME 22 IAW SRM 51-40-02 AND 51-10-02. W/C 1075SDR V0XR20110331003Doubler · corroded(V0XR) DOUBLERS AT FRAMES 20 AND 22 ON THE RT BEAM ARE CORRODED. REMOVED AND REPLACED DOUBLERS AT FRAMES 20 AND 22 IAW EMB145 SRM 51-40-02 AND 51-10-02. W/C 1067SDR V0XR20110331002Beam · corroded(V0XR) RT BEAM AT FRAME 18-24 IS CORRODED. RT BEAM AT FRAME 18-24 REMOVED AND REPLACED PER EMB145 SRM 51-10-02, 51-20-03, 51-40-02, 51-21-04, AND 51-20-01. W/C 1066SDR V0XR20110331001Profile · corroded(V0XR) FLOORBOARD ANGLES ON IB LT BEAM AT FRAME 18-19 ARE CORRODED. REMOVED AND REPLACED PROFILES (P/N'S 145-21718-005 AND 145-21718-007) ON IB LT BEAM AT FRAME 18-19 IAW EMB145 SRM 51-20-03, 51-10-02, 51-40-02, AND 51-20-01. W/C 1061SDR SIMA201109401Floor Support · corrodedDURING MAINTENANCE BASE INSPECTION FOUND THE LEFT OMEGA BEAM CORRODED AT FRAME 20 CROSS MEMBER. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED OMEGA BEAM IAW SRM 53-00-10 FIGURE 201. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA11IA064Hydraulic Line · leakingIAH - FLIGHT 2042, THE CREW REPORTED THAT THE NUMBER ONE ENGINE DRIVEN HYD PUMP HAD FAILED, AND THAT THE SYSTEM 1 FLUID WAS LOW. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE UNLOCK ACTUATOR HYDRAULIC LINSDR C2XA11CL086Smoke Detector · intermittentROC FLT 2141 THE CREW REPORTED A LAV SMOKE INDICATION ON THE EICAS. MAINTENANCE INSPECTED AND REPLACED THE LAV SMOKE DETECTOR. OPERATIONAL CHECKS WERE GOOD.SDR RAIA201103310001Packing · failedLANDING GEAR AIR/GND FAIL MESSAGE ON EICAS. MAINTENANCE TROUBLESHOT, DISCOVERED NLG STRUT NOT CENTERING. REPACKED NLG STRUT, OPS CHECK GOOD IAW EMB 145 AIRCRAFT MAINTENANCE MANUAL PROCEDURE.SDR SIMA201109103Washer · wornFOR FLIGHT 3242 THE CREW REPORTED THE FLIGHT ATTENDANT COULD NOT OPEN THE MAIN DOOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED WASHERS BETWEEN ARM LOWER FITTING NR 1 AND FITTING NR 2 IAW ETN EM 52-013R1. THE DOOR OPERATIONAL CHECK WAS GOODSDR RAIA201104010001Guide · out of adjustMAIN DOOR RELEASE LEVER DIFFICULT TO MOVE. FLIGHT ATTENDANT UNABLE TO OPEN DOOR. MAINTENANCE LUBED DOOR SEAL, FRAME SEAL AND ADJUSTED DOOR FRAME GUIDES IAW AMM PROCEDURE, OPS CHECKED GOOD.SDR V0XR201103300004Profile · corrodedRT PROFILE AT FR 61 IS CORRODED BEYOND LIMITS. R & R PROFILE.SDR V0XR201103300003Gusset · corrodedLT GUSSET AT FR 59-61 IS CORRODED BEYOND LIMITS. R & R GUSSET.SDR V0XR201103300002Sill · corrodedRT SILL AT FR 60-65 IS CORRODED BEYOND LIMITS. R & R SILL.SDR V0XR201103300001Sill · corrodedRT SILL AT FR 23-29 IS CORRODED BEYOND LIMITS. R & R SILL.SDR V0XR20110329008Gusset · corrodedLEFT GUSSET FROM FRAMES 36-40 REQUIRES REPLACEMENT DUE TO CORROSION. REPLACED LT GUSSET FROM FRAMES 36-40PER EMB145 SRM 51-10-02, 51-40-02, 51-40-01, 51-40-09. W/C 2122SDR V0XR20110329007AAngle · corrodedSCALLOPED ANGLE AT FRAME 23 IS CORRODED OUT OF LIMITS. REPLACED CORRODED SCALLOPED ANGLE AT FRAME 23 WITH NEW PART IAW EMB145 SRM 51-10-02 AND 51-40-02. W/C 1105SDR V0XR20110329007Sill · corrodedLT SILL AT FRAME 59-60 IS CORRODED OUT OF LIMITS. R & R LT SILL AT FRAME 59-60 IAW SRM 51-10-02, 51-40-02, AND 51-20-03.SDR V0XR20110329006Gusset · corroded(V0XR) RT GUSSET AT FRAME 59-61 CORRODED OUT OF LIMITS. REMOVED AND REPLACED R/H GUSSET AT FR 59-61 AS REQUIRED IAW EMB145 SRM 51-10-02, 51-21-04, 51-21-05 AND 51-20-01. W/C 1097SDR V0XR20110329005Gusset · corrodedLEFT GUSSET AT FRAME 23-29 CORRODED OUT OF LIMITS. REPLACED CORRODED LT GUSSET AT FRAME 23-29 WITH NEW PART IAW SRM 51-10-02 AND 51-40-02. W/C 1094SDR V0XR20110329004Angle · corrodedANGLE ON RT RY 780.0 AT FRAME 23 IS CORRODED OUT OF LIMITS. REPLACED CORRODED ANGLE ON RT RY 780.0 AND FRAME 23 WITH NEW PART IAW SRM 51-10-02 AND 51-40-02. W/C 1093SDR V0XR20110329003Angle · corroded(V0XR) U-SHAPE ANGLES AT PASSENGER DOOR REQUIRE REPLACEMENT DUE TO CORROSION. U-SHAPE ANGLES PN'S 145-24131-009 AND 145-24131-011 AT PASSENGER DOOR REPLACED PER EMB145 SRM 51-20-03, 51-40-02, AND CPM 51-21-04.SDR V0XR20110329002Floor Support · corroded(V0XR) FORWARD DIGITAL PLATE AT FRAME 14-16 HAS CORROSION. REPLACED CORRODED FORWARD DIGITAL AT FRAME 14-16 WITH NEW PART IAW EMB145 SRM 51-10-02 AND 51-40-02. W/C 1064.SDR V0XR20110329001Structure · corroded(V0XR) HORSESHOE DIGITAL PLATE AT FRAME 16-18 HAS CORROSION. REMOVED AND REPLACED HORSESHOE AT FRAME 16-18 IAW EMB145 SRM 51-20-03, AND 51-40-02. W/C 1063SDR RAIA201103280002Light · inoperativePAX DOOR EXTERNAL EMERGENCY LIGHT NR 13 WILL NOT ILLUMINATE. MAINTENANCE REPLACED DEFECTIVE BULB IAW EMB 145 AIRCRAFT MAINTENANCE MANUAL, OPS CHECK GOOD.SDR C2XA11CL085Fitting · looseCLE - MAINTENANCE REPORTED NR 1 ENGINE FUEL LEAK. INSPECTED AND RE-SECURED LOOSE FUEL FITTING ON THE NR 1 FPMU. OPERATIONAL CHECKS AND LEAK CHECKS WERE GOOD.SDR C2XA11SH080Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION BETWEEN FR 23-29. REPAIRED OMEGA BEAM IAW EMB 145 SRM 51-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH079Floor Support · corrodedSHV - DURING C-CHECK CENTER OMEGA BEAM HAS CORROSION BETWEEN FR 23-29. REPAIRED OMEGA BEAM IAW EMB 145 SRM 51-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH078Frame · crackedSHV - DURING C-CHECK FR 10 IS CRACKED JUST BELOW LT DV WINDOW. REPLACED SECTION OF FRAME IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH077Frame · crackedSHV - DURING C-CHECK RT FRAME 10 IS CRACKED. REPLACED SECTION OF FRAME IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA201103280006Connector · malfunctionedDURING CLIMB THE EICAS HAD A AIR GROUND MESSAGE. AIRCRAFT RETURNED FROM FLIGHT. AIRCRAFT DID A FERRY FLIGHT TO STL. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE NLG WOW PROX SWITCH CONNECTOR. SYSTEM OPS CHECKED GOOD.SDR RAIA201103280005Sensor · malfunctionedDURING CLIMB THE FLIGHT CREW GOT AN EICAS LANDING GEAR AIR FAIL MESSAGE. AIRCRAFT RETURNED FROM FLIGHT. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE LT MLG WOW SENSOR. SYSTEM OPS CHECKED GOOD.SDR SIMA201108901Unknown · odorON FLIGHT 3616 DESCENDING THROUGH FLIGHT LEVEL 240 THE CREW REPORTED A STRONG ELECTRIC ODOR IN THE COCKPIT AND CABIN. THE ODOR STARTED TO GO AWAY AROUND 13000 FEET. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. C/W ETN NO: EMSDR SIMA201108803Fire Detector · faultyON FLIGHT 3640 ON LANDING THE CREW REPORTED THAT THE BAGGAGE SMOKE INDICATION ON ECIAS CAME ON. THE CREW PRESSED THE FIRE EXTINGUISHER BUTTON. THE CAPTAIN DECLARED AN EMERGENCY. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. SDR SIMA201108801Unknown · odorON FLIGHT 4278 THE CREW REPORTED THAT DURING THE CLIMBOUT WHILE DOING AN ANTI-ICE TEST, HAD A BURNING ODOR IN THE COCKPIT AND CABIN. THE CREW CONTINUED ON TO ORD AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. GROUND RAN ENGINES IAW ETN SDR C2XA11CL084Bleed Valve · faultyORD FLT 5876 - THE CREW REPORTED A STRONG FUEL ODOR DURING APU START. MAINTENANCE INSPECTED AND REPLACED THE APU BLEED VALVE. OPERATIONAL CHECKS WERE GOOD.SDR C2XA11CL083Unknown · smokeORD FLT 6051 - THE CREW REPORTED WHILE SITTING ON GROUND, PACK 2 WAS SET TO MANUAL MODE TO EXPEDITE COOLING THE CABIN AND COCKPIT FILLED WITH SMOKE. THE APU BLEED WAS OPEN. MAINTENANCE INSPECTED AND PERFORMED OPERATIONAL CHECKS OF THE APU AND PACK SYSTEMS.
Back to Embraer EMB-145LR